Plan Review Stops For Permit 16030369 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-11-28 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-11-28 |
Time |
08:58 |
Sent To |
|
|
Notes |
2016-11-28 08:59:58 | INTERIOR DEMO AND NEW STAIR FOUNDATIONS. FIRE WATCH | | REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-22 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-22 |
Time |
10:56 |
Sent To |
|
|
Notes |
2016-08-22 12:24:56 | SCOPE OF WORK LIMITED TO DEMO, FOUNDATIONS AND | | STRUCTURAL STEEL SUPPORTS FOR NEW STAIRS. OWNER TO MAKE | | APPLICATION FOR THE INSTALLATION OF NEW STAIRS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-07-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-28 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-28 |
Time |
10:03 |
Sent To |
|
|
Notes |
2016-07-28 10:04:46 | DEMO PHASE ONLY. SEE REVISED WORK DESCRIPTION. | | RE-SUBMITTAL REQUIRED. APPLICANT TO COMPLY WITH | | PREVIOUS REVIEW COMMENTS. CST |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-06-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-15 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-06-15 |
Time |
11:07 |
Sent To |
|
|
Notes |
2016-06-15 14:02:48 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | DATE: 6/15/16 | | ACTION: FAIL | | | | THE PLANS RE-SUBMITTED FOR REVIEW CONSIST OF A | | RE-DESIGN FROM THE 1ST REVIEW. THE ARCHITECTURAL AND | | LIFE SAFETY PLANS SUBMITTED ARE LIMITED IN SCOPE AND | | GENERAL IN NATURE. A THOROUGH REVIEW CANNOT BE | | PERFORMED AT THIS TIME. THE ATTACHED LIST OF ITEMS IS | | FOR GUIDANCE ONLY AND IS NOT TO BE CONSTRUED AS A FINAL | | LIST OF COMMENTS TO BE ADDRESSED BY THE DESIGN TEAM. | | ADDITIONAL COMMENTS MAY BE GENERATED UPON RE-SUBMITTAL | | OF PLANS. | | | | 1. PROVIDE DETAIL OF NEW ISOLATED SPREAD FOOTINGS. | | 2. PROVIDE DETAIL & SHOP DRAWINGS OF NEW STRUCTURAL | | STEEL SKELETON STRUCTURE. | | 3. PROVIDE SHOP DRAWINGS OF NEW STAIRS (BY OTHERS). | | 4. PROVIDE SHORING PLAN FOR REMOVAL OF STRUCTURAL | | SLABS. | | 5. PROVIDE DETAIL OF EXISTING WALLS TO BE USED AS PART | | OF RATED SHAFT. WALLS SHALL COMPLY WITH FBC 706 (WALLS) | | AND 713 (SHAFTS). | | 6. PROVIDE DETAIL OF NEW WALLS TO BE USED AS PART OF | | RATED SHAFT. WALLS SHALL COMPLY WITH UL 404 PER PLANS. | | 7. PROVIDE DETAIL OF RATED DOOR ASSEMBLY. DOORS SHALL | | BE RATED PER FBC TABLE 716.5 AND INSTALLED PER NFPA 80. | | 8. PROVIDE EXIT DOOR HARDWARE SPECS. | | 9. PROVIDE STAIRWAY ILLUMINATION PER FBC 1011.3. | | 10. LABEL STAIRS ACCORDING TO THE JEZERINAC GROUP'S | | REPORT. STAIR # 1 AND STAIR #2. LOBBY STAIRS ARE | | EXISTING AND ARE OUTSIDE THE SCOPE OF THIS SUBMITTAL. | | 11. PROVIDE LIFE SAFETY PLAN INDICATING PATH OF TRAVEL | | AND EXIT DISCHARGE TO A PUBLIC WAY, DISTANCE TO EXIT'S, | | EMERGENCY ILLUMINATION AND RATED WALLS. | | 12. VALUE OF PROJECT APPEARS LOW. | | 13. MECHANICAL, ELECTRICAL & PLUMBING PERMITS REQUIRED. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | FAILURE TO PROVIDE DOCUMENTATION OF ESTIMATED COSTS MAY | | DELAY THE APPLICATION PROCESS. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-03-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-03-18 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-03-18 |
Time |
15:39 |
Sent To |
FIRE |
|
Notes |
2016-03-18 16:09:28 | 1ST REVIEW: FBC 2014 5TH ED | | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | 1. PROVIDE DETAIL FOR WINDOW OPENINGS TO B ENCLOSED. | | 2. PROVIDE FLOOR PLAN WITH THE FOLLOWING: EXIT ACCESS | | PER FBC 1014.1, EXIT PASSAGEWAY WIDTH PER FBC 1023, | | EXIT SIGNS PER FBC 1011, EXIT PATH OF TRAVEL PER TABLE | | 1016.2, EXIT DOORS COMPLYING WITH FBC 1008.1.1 AND EXIT | | ILLUMINATION PER FBC 1011.3. | | MULTIPLE DEMENSIONS MISSING ON STAIR DETAILS: LANDING | | WIDTH AT EXIT DOOR - FBC 1008.1.6, STAIRWAY LANDING PER | | FBC 1009.8, EXIT DOORS PER FBC 1008.1.1, HANDRAIL | | DETAIL PER FBC 1012.3 AND HANDRAIL EXTENSIONS PER FBC | | 1012.6. | | 3. DETAIL A, PG A-1.01 SHOWS A FENCE IN THE PATH OF | | TRAVEL AT STAIR LANDING. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-07-27 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-07-27 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-07-25 |
Time |
16:56 |
Sent To |
P |
|
Notes |
2016-07-27 08:47:35 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | PASSED AS A DEMOLITION PERMIT ONLY ALL TEMPORARY | | ELECTRIC SHALL BE GFCI PROTECTED IN ACCORDANCE WITH NEC | | 590.6 | | | | NEW PLANS TO INCLUDE THE FOLLOWING AS A MINIMUM : | | | | 1) FBC 1006.1 ILLUMINATION REQUIRED.THE MEANS OF | | EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE | | ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY | | THE MEANS OF EGRESS IS OCCUPIED. | | - PLEASE SHOW EMERGENCY LIGHTING BY THE HALLWAYS TO | | VERIFY MINIMUM ILLUMINATION LEVELS OF 1 FOOT CANDLE AT | | THE WALKING SURFACE. FBC 1006.2 | | | | 2) FBC 1011.1 EXITS AND EXIT ACCESS DOORS SHALL BE | | MARKED BY AN APPROVED EXIT SIGN READILY VISIBLE FROM | | ANY DIRECTION OF EGRESS TRAVEL. THE PATH OF EGRESS | | TRAVEL TO EXITS AND WITHIN EXITS SHALL BE MARKED BY | | READILY VISIBLE EXIT SIGNS TO CLEARLY INDICATE THE | | DIRECTION OF EGRESS TRAVEL IN CASES WHERE THE EXIT OR | | THE PATH OF EGRESS TRAVEL IS NOT IMMEDIATELY VISIBLE TO | | THE OCCUPANTS. | | INTERVENING MEANS OF EGRESS DOORS WITHIN EXITS SHALL BE | | MARKED BY EXIT SIGNS. EXIT SIGN PLACEMENT SHALL BE SUCH | | THAT NO POINT IN AN EXIT ACCESS CORRIDOR OR EXIT | | PASSAGEWAY IS MORE THAN 100 FEET (30 480 MM) OR THE | | LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS | | LESS, FROM THE NEAREST VISIBLE EXIT SIGN. | | - SHOW EXIT SIGNS LOCATION IN THE HALLWAYS TO COMPLY. | | | | 3) ILLUMINATION SHALL BE PROVIDED FOR ALL WORKING | | SPACES ABOUT SERVICE EQUIPMENT, SWITCHBOARDS, | | PANELBOARDS. NEC 110.26(D) SHOW LIGHTING BY THE | | ELECTRICAL PANELS IN THE HALLWAYS TO COMPLY WITH THIS | | REQUIREMENT. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-06-15 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-06-15 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-06-15 |
Time |
15:12 |
Sent To |
|
|
Notes |
2016-06-15 15:30:48 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | -THE FOLLOWING ARE THE ELECTRICAL REQUIREMENTS THAT | | APPLY TO THE INTERIOR STAIRWAY MEANS OF EGRESS | | | | - 1006.1 ILLUMINATION REQUIRED. 1006.2 ILLUMINATION | | LEVEL. | | THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, | | SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE | | SERVED BY THE MEANS OF EGRESS IS OCCUPIED. | | THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE | | LESS THAN 1 FOOTCANDLE (11 LUX) AT THE WALKING SURFACE. | | | | - FBC-B 1011. EXIT SIGNAGE REQUIRED.THE FACE OF AN EXIT | | SIGN ILLUMINATED FROM AN EXTERNAL SOURCE SHALL HAVE AN | | INTENSITY OF NOT LESS THAN 5 FOOTCANDLES | | | | - NEC 700.12 (F) (4) ? EMERGENCY/EXIT LIGHTING SHALL BE | | FED BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR | | MORE LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY | | BE ON OWN CIRCUIT. | | | | - 1022.5 PENETRATIONS. | | PENETRATIONS INTO AND OPENINGS THROUGH INTERIOR EXIT | | STAIRWAYS AND RAMPSARE PROHIBITED EXCEPT FOR REQUIRED | | EXIT DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR | | INDEPENDENT VENTILATION OR PRESSURIZATION, SPRINKLER | | PIPING, STANDPIPES, ELECTRICAL RACEWAY FOR FIRE | | DEPARTMENT COMMUNICATION SYSTEMS AND ELECTRICAL RACEWAY | | SERVING THE INTERIOR EXIT STAIRWAY AND RAMP AND | | TERMINATING AT A STEEL BOX NOT EXCEEDING 16 SQUARE | | INCHES (0.010 M2). SUCH PENETRATIONS SHALL BE PROTECTED | | IN ACCORDANCE WITH SECTION 714. THERE SHALL BE NO | | PENETRATIONS OR COMMUNICATING OPENINGS, WHETHER | | PROTECTED OR NOT, BETWEEN ADJACENT INTERIOR EXIT | | STAIRWAYS AND RAMPS. OPEN PENETRATIONS SHALL BE | | PROTECTED IN ACCORDANCE WITH SECTION 714.3.2. | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2016-08-16 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-08-16 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-08-16 |
Time |
15:23 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2016-07-20 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-07-20 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-07-20 |
Time |
11:20 |
Sent To |
|
|
Notes |
2016-07-20 12:14:25 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PROGRESS IS BEING MADE AND ALL EFFORTS ARE APPRECIATED; | | HOWEVER, LIFE SAFETY CONCERNS REMAIN UNCLEAR. | | | | | | | | | | 1) A LIFE SAFETY PLAN, DURING CONSTURCTION IS NEEDED TO | | ASSIST MY REVIEW OF HOW/WHERE WILL THE RESIDENTS EXIT | | DURING CONSTRUCTION. | | | | IT APPEARS THAT THE HALLWAYS LEADING TO THE SECONDARY | | EXIT EGRESS, THE FIRE ESCAPE STAIRS, APPEARS TO BE/WILL | | BE BLOCKED BY CONSTURCTION. | | | | PLEASE PROVIDE DETAIL OF HOW EACH FLOOR WIL HAVE SAFE | | TRAVEL TO TWO REMOTE EXITS DURING CONSTUCTION. | | | | | | 2) DUE TO THE NATURE OF THE DEMOLITION AND AGE OF THE | | BUILDING I AM CONCERNED REGARDING THE SAFETY OF THE | | OCCUPANTS DURING CONSTRUCTION, ESPECIALLY DURING THE | | DEMOLITION, POTENTIALLY UNSTABLE STRUCTURE, PERIOD. | | | | THERE IS NO NOTE/NARRATIVE/STATEMENT/RECOMMENDATION OF | | ANYONE WITH THE EXPERTISE AS TO THE CONTINUED OCCUPANCY | | OF RESIDENTS OF THE BUILDING DURING THE | | DEMOLITION/CONSTRUCTION PERIODS. | | | | PLEASE PROVIDE SOME SORT OF OFFICIAL SIGNED AND SEALED | | DOCUMENTATION FROM A QUALIFIED LICENSED AUTHORITY TO | | CONFIRMED/VERIFY THE RESIDENTS SAFETY OCCUPYING THE | | BUILDING DURING DEMOLITION/CONSTRUCTION. | | | | | | 3) THERE DOES NOT APPEAR TO BE A NOTE OR NARRATIVE | | REAGARDING ALL WORK ON THE FIRE LARM OR FIRE SPRINKLER | | SHALL BE DONE BY CERITIFED LIFE SAFETY CONTRACTORS | | UNDER SEPARATE SHOP DRAWINGS. | | | | PLEASE PROVIDE. | | | | | | 4) THE VALUE OF THIS PROJECT $150,000 APPEARS TO BE TOO | | LOW, PLEASE PROVIDE VERIFICATION/JUSTIFICATION AND/OR | | INCREASE ACCORDINGLY. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-06-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-06-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-06-09 |
Time |
11:25 |
Sent To |
B |
|
Notes |
2016-06-09 11:59:12 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | THIS PROVISO IS WRITTEN TO EXPEDITE THIS PROJECT. CLOSE | | COMMUNICATION WITH THE PREVENTION BUREAU SHALL BE | | MAINTAINED TO ENSURE THE SAFE AND EFFECTIVE EGRESS OF | | RESIDENTS DURING THE CONSTRUCTIOIN PERIOD. THIS MAY BE | | ACCOMPLISHED THROUGH PHONE, EMAIL AND WITH REGULAR SITE | | VISITS. | | | | 1) SHEET LS1.01 - A FIRE WATCH SHALL BE PUT IN PLACE | | THROUGHOUT THE CONSTRUCTION PERIOD. IT SHALL BE | | REVIEWED AND APPROVED BY THE FIRE MARSHAL. | | | | 2) SHEET A1.01 & 1.02 - THE STAIR CONSTRUCTION | | INCLUDING THE TREADS AND RISERS SHALL COMPLY WITH NFPA | | 101, CHAPTER 7 AND WITH THE STAIR DETAIL SUBMITTED | | UNDER SEPARATE SHOP DRAWINGS. | | | | 3) SHEET A0.10 - THE EXTERIOR STAIR SHALL BE CONFIMED | | TO BE OPERATIONAL AND REMAIN IN PLACE UNTIL THE | | INTERIOR STAIRS ARE COMPLETE. THE FIRE WATCH PERSONNEL | | SHALL BE INSTRUCTED AND DEMONSTRATE THAT THEY CAN USE | | THE STAIRS. | | | | 4) NO SHHEET - NO EMERGENCY LIGHTING IS PROVIDED. | | EMERGENCY LIGHTING SHALL BE PROVIDED. | | | | 5) NO SHEET - NO DOOR DETAIL IS PROVIDED, INCLUDING | | EXIT HARDWARE. PLEASE PROVIDE THE APPLICABLE DOOR | | DETAIL IN THE FORM OF REVISION AS SOON AS PRACTICAL. | | | | 6) THE VALUE INDICATED IS $ 150,000 AND IS TOO LOW. | | PLEASE PROVIDE A COPY OF THE CONTRACT AND/OR ADJUST THE | | VALUE ACCURATELY. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2016-03-24 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-03-24 |
Time |
|
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-03-24 |
Time |
10:23 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-11-28 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-11-23 |
Time |
16:49 |
Sent To |
|
|
Notes |
2016-11-23 16:49:42 | CTHROOP'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-22 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-12 |
Time |
10:53 |
Sent To |
|
|
Notes |
2016-08-15 10:53:48 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-07-28 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-07-28 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-07-18 |
Time |
09:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-06-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-06-15 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-05-25 |
Time |
10:32 |
Sent To |
|
|
Notes |
2016-06-06 12:00:39 | TO MISC 2 BOX. | 2016-05-26 10:33:04 | RESUB ROUTED TO AAPONTE VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-03-24 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-03-24 |
Time |
|
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-03-08 |
Time |
08:30 |
Sent To |
Z |
|
Notes |
2016-03-16 15:23:43 | TO MISC 2 BOX. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2016-07-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-07-25 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-07-25 |
Time |
07:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-07-27 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-07-27 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-07-27 |
Time |
12:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-06-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-06-15 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-06-15 |
Time |
16:32 |
Sent To |
|
|
Notes |
2016-06-15 16:59:50 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. PLANS ARE UNCLEAR ON THE SCOPE OF PLUMBING WORK | | BEING DONE SHOW ON PLANS WHAT FIXTURE ARE BEING REMOVED | | AND LINES CAPPED. PER WPB TO FBC SEC. 107.2.1 | | | | 2. ARE PLUMBING LINES BEING CAPPED OFF IN THE WALL OF | | STUBBED OUT FOR REUSE SHT A-0.10 NOTE#2 INDICATES LINES | | BEING CAPPED AND STUBBED OUT PLEASE CLARIFY.. PER WPB | | TO FBC SEC. 107.2.1 | | | | 3. ARE YOU ELIMINATING BATHROOMS ALONG WITH DWELLING | | UNITS THEY SERVE. . PER WPB TO FBC SEC. 107.2.1 | | | | 4. ARE ANY OF THE BATHROOMS THAT ARE BEING ELIMINATED | | USED FOR EMPLOYEE OR PUBLIC USE IF SO THEY WILL BE | | REQUIRED TO BE RELOCATED. PER FBC PL SEC. 403 |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
4 |
Status |
P |
Date |
2016-12-09 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2016-12-09 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2016-12-09 |
Time |
09:46 |
Sent To |
I |
|
Notes |
2016-12-09 09:49:10 | RECEIVED SPECIAL INSPECTOR AGREEMENT AND SI RESUME | | SIGNED BY MONZER I. FARAMAWI. PE, S.I. |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
3 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-11-28 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-11-28 |
Time |
09:12 |
Sent To |
|
|
Notes |
2016-11-28 09:14:25 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | | | 1. RESIDENT INSPECTOR REQUIRED. | | 2. COMPLETE RESIDENT INSPECTOR AGREEMENT AND RETURN IN | | TRIPLICATE. |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
2 |
Status |
N |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-22 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-22 |
Time |
10:56 |
Sent To |
|
|
Notes |
2016-08-22 12:26:56 | ENGINEER OF RECORD AND GENERAL CONTRACTOR TO SUBMIT | | RESIDENT INSPECTOR AGREEMENT PRIOR TO COMMENCEMENT. |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
1 |
Status |
N |
Date |
2016-07-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-28 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-28 |
Time |
09:58 |
Sent To |
|
|
Notes |
2016-07-28 10:03:22 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | ACTION: N/A | | DATE: 7/28/16 | | | | 1. RESIDENT INSPECTOR WILL BE REQUIRED FOR THIS | | PROJECT. | | 2. INCLUDE 3 COPIES OF COMPLETED RESIDENT INSPECTOR | | AGREEMENT WITH RE-SUBMITTAL. | | 3. INCLUDE RESUME OF ENGINEER OF RECORD AND ANY ON-SITE | | 468 LICENSED INSPECTORS. | | 4. PROVIDE WORK HISTORY OF SIMILAR PROJECTS FROM | | CONTRACTOR. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2016-07-28 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-07-28 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-07-28 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-06-06 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-06-06 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-06-06 |
Time |
11:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-03-16 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-03-24 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-03-16 |
Time |
14:46 |
Sent To |
|
|
Notes |
2016-03-16 15:23:14 | PROPOSED STAIR IS BLOCKING THE EXISTING 14' ALLEY ON | | THE SOUTH SIDE OF THE BUILDING. EXISITNG ALLEY CANNOT | | BE BLOCKED AS IT IS USED BY SURROUNDING PROPERTIES. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|