Plan Review Stops For Permit 16030347 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-01-10 |
Time |
19:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-01-10 |
Time |
19:58 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-01-03 |
Time |
19:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-01-03 |
Time |
18:09 |
Sent To |
|
|
Notes |
2017-01-03 18:21:16 | REVIEWED ENERGY CALCULATIONS THAT WERE E-MAILED BY | | SASHA BUBANJA FROM FASTRACK MCI. WAITING FOR | | CALCULATIONS AND SECOND SET OF PLANS TO BE RE-SUBMITTED | | TO COMPLETE BUILDING REVIEW. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-11-28 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-11-28 |
Time |
14:28 |
Sent To |
|
|
Notes |
2016-11-28 14:45:28 | RESIDENTIAL (R3) ADDITION/ALTERATION SIXTH BUILDING | | REVIEW CHECKLIST. | | CODE: FBC-5TH EDITION (2014). | | | | NOTE: | | THE PERMIT CAN NOT BE ISSUED WITHOUT THE ENERGY | | CALCULATIONS. | | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION | | | | | | | | 1- REVISE ENERGY CALCULATIONS SUBMITTED: | | A)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | FORM, INCLUDING CORRECT OWNER'S NAME, BUILDER NAME, | | PERMIT OFFICE AND JURISDICTION NUMBER. SEC. | | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | RESPONSE: | | REPEAT COMMENT. NEEDS BUILDER NAME, PERMIT OFFICE AND | | JURISDICTION NUMBER. | | | | B) SEC. R806.2 OF FBC-RESIDENTIAL, 5TH EDITION (2014) | | REQUIRES 1/150 ATTIC VENTILATION RATIO. ATTIC | | INFORMATION ON PAGE 2 OF 4 SPECIFIES 1/300 ATTIC | | VENTILATION RATIO. PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW THIS HOUSE COMPLIES WITH THE | | EXCEPTION OF SEC. R806.2 FOR 1/300 ATTIC VENTILATION | | RATIO. OTHERWISE REVISE AS REQUIRED. | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AT ALL. SEE ARCHITECTURAL | | PLANS. THEY CALL FOR 1/150 RATIO NOT 1/300. REVISE AS | | REQUIRED. | | | | C) COMPLETE THE INSPECTION CHECKLIST AS REQUIRED BY | | SEC. R405.4.2 FBC-ENERGY CONSERVATION. | | RESPONSE: | | INSPECTION CHECKLIST NEED TO BE COMPLETED. CHECKLIST | | NEED TO BE CHECKED WITH THE ITEMS THAT APPLY. | | | | D) PROVIDE THE NAME OF THE INDIVIDUAL COMPLETING THE | | ENERGY CALCULATIONS AS REQUIRED BY SEC. R405.4.2 | | FBC-ENERGY CONSERVATION. | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AT ALL. THE NAME OF THE | | PERSON COMPLETING THE ENERGY CALCULATIONS WAS NOT | | PROVIDED. ONLY A COPY OF A SIGNATURE WAS PROVIDED. | | PROVIDE THE COMPLETE NAME OF THE PERSON COMPLETING THE | | CALCULATIONS. | | | | NOTE: LABEL FOR WINDOWS AND DOORS U-FACTOR AND SHGC | | FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL BE | | REQUIRED FOR VERIFICATION. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2016-11-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-11-21 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-11-21 |
Time |
13:50 |
Sent To |
M |
|
Notes |
2016-11-21 14:18:40 | RESIDENTIAL (R3) ADDITION/ALTERATION FIFTH BUILDING | | REVIEW CHECKLIST. | | CODE: FBC-5TH EDITION (2014). | | | | NOTE: | | THE PERMIT CAN NOT BE ISSUED WITHOUT THE ENERGY | | CALCULATIONS. | | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION | | | | | | | | 1- REVISE ENERGY CALCULATIONS SUBMITTED: | | | | A) ORIGINAL COMMENT: | | PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | FORM, INCLUDING CORRECT OWNER'S NAME ("HOMEOWNER" IS | | NOT AN OWNER), BUILDER NAME, PERMIT OFFICE AND | | JURISDICTION NUMBER. SEC. R101.5.1.1.2 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | RESPONSE: | | THE NAME OF THE OWNER DOESN'T MATCH THE NAME OF THE | | OWNER SHOWN ON THE PERMIT APPLICATION. DANIEL PEREIRA | | IS NOT THE NAME LISTED IN THE PERMIT APPLICATION. | | REVISE AS REQUIRED. | | | | B) ORIGINAL COMMENT: | | SEC. R806.2 OF FBC-RESIDENTIAL, 5TH EDITION (2014) | | REQUIRES 1/150 ATTIC VENTILATION RATIO. ATTIC | | INFORMATION ON PAGE 2 OF 4 SPECIFIES 1/300 ATTIC | | VENTILATION RATIO. PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW THIS HOUSE COMPLIES WITH THE | | EXCEPTION OF SEC. R806.2 FOR 1/300 ATTIC VENTILATION | | RATIO. OTHERWISE REVISE AS REQUIRED. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AT ALL. SEE ARCHITECTURAL | | PLANS. THEY CALL FOR 1/150 RATIO NOT 1/300. REVISE AS | | REQUIRED. | | | | C) ORIGINAL COMMENT: | | REVISE THE WINDOWS OVERHANG DEPTH AND SEPARATION TO | | MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, | | 5TH EDITION (2014). | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | D) ORIGINAL COMMENT: | | MISSING THE INSPECTION CHECKLIST AS REQUIRED BY SEC. | | R405.4.2 FBC-ENERGY CONSERVATION. | | | | RESPONSE: | | INSPECTION CHECKLIST NEED TO BE COMPLETED. CHECKLIST | | NEED TO BE CHECKED WITH THE ITEMS THAT APPLY. | | | | E) ORIGINAL COMMENT: | | PROVIDE THE NAME OF THE INDIVIDUAL COMPLETING THE | | ENERGY CALCULATIONS AS REQUIRED BY SEC. R405.4.2 | | FBC-ENERGY CONSERVATION. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AT ALL. THE NAME OF THE | | PERSON COMPLETING THE ENERGY CALCULATIONS WAS NOT | | PROVIDED. ONLY A COPY OF A SIGNATURE WAS PROVIDED. | | PROVIDE THE COMPLETE NAME OF THE PERSON COMPLETING THE | | CALCULATIONS. | | | | NOTE: LABEL FOR WINDOWS AND DOORS U-FACTOR AND SHGC | | FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL BE | | REQUIRED FOR VERIFICATION. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2016-10-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-10-26 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-10-26 |
Time |
10:53 |
Sent To |
|
|
Notes |
2016-10-26 10:55:37 | 10/26/16 TALKED TO RICHARD BARNES (ARCH.) TO GO OVER | | COMMENTS (# OF PEOPLE , A/C SIZING, A/C SEER). | | | | 10/26/16 TALKED TO TONY PIEDRA (CONTRACTOR) TO GO OVER | | COMMENTS AND PROVISO. HE SAID HE'LL RESUBMIT ALONG WITH | | LANDSCAPE REQUEST. | | | | | | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW | | CHECKLIST. | | CODE: FBC-5TH EDITION (2014). | | | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS THAT CONTRACTOR MAY SUBMIT REQUESTED INFORMATION | | AFTER THE PERMIT IS ISSUED AND BEFORE INSPECTIONS TO | | AVOID CONFLICTS/DELAYS. REVISION FEES MAY APPLY. | | CONTRACTOR TO ADVICE IF RESUBMITTING INFORMATION NOW OR | | IF PROVISO OPTION IS PREFERRED AT THIS TIME. | | | | 1- REVISE ENERGY CALCULATIONS SUBMITTED: | | A) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | FORM, INCLUDING CORRECT OWNER'S NAME ("HOMEOWNER" IS | | NOT AN OWNER), BUILDER NAME, PERMIT OFFICE AND | | JURISDICTION NUMBER. SEC. R101.5.1.1.2 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | B) REVISE NUMBER OF OCCUPANTS SHOWN UNDER "SPACES" ON | | PAGE 2 OF 4. THIS IS A THREE BEDROOM HOUSE. CLARIFY WHY | | CONSIDERING ONLY ONE OCCUPANT. THE NUMBER OF OCCUPANTS | | MAY AFFECT THE A/C SIZING LOAD CALCULATIONS. A HIGH | | NUMBER OF OCCUPANTS MAY RESULT TO OVERSIZE THE A/C | | EQUIPMENT. ON THE OTHER HAND, A LOW NUMBER OF OCCUPANTS | | MAY RESULT TO UNDERSIZE THE A/C EQUIPMENT. PROVIDE THE | | COMPLETE A/C LOAD CALCULATIONS (NOT JUST THE SUMMARY) | | TO VERIFY EQUIPMENT SIZING. EQUIPMENT CAN NOT BE | | OVERSIZED OR UNDERSIZED. SEE SEC. R403.6.1 AND SEC. | | R403.6.1.1 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | TYPICALLY A THREE BEDROOM HOUSE IS OCCUPIED BY MORE | | THAN ONE PERSON. THE PURPOSE OF THE ENERGY CALCULATIONS | | AND EQUIPMENT SIZING IS TO CONTRIBUTE TO THE ENERGY | | CONSERVATION BY PROPERLY DESIGNING THE STRUCTURE AND | | THE EQUIPMENT TO BE USED. IF ONLY USING ONE PERSON FOR | | THE DESIGN PARAMETERS, THEN PROVIDE COMPLETE | | DOCUMENTATION SUPPORTING THIS DESIGN APPROACH. | | DOCUMENTATION WILL BE FORWARDED TO THE BUILDING | | OFFICIAL FOR REVIEW AND APPROVAL. | | | | C) SEC. R806.2 OF FBC-RESIDENTIAL, 5TH EDITION (2014) | | REQUIRES 1/150 ATTIC VENTILATION RATIO. ATTIC | | INFORMATION ON PAGE 2 OF 4 SPECIFIES 1/300 ATTIC | | VENTILATION RATIO. PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW THIS HOUSE COMPLIES WITH THE | | EXCEPTION OF SEC. R806.2 FOR 1/300 ATTIC VENTILATION | | RATIO. OTHERWISE REVISE AS REQUIRED. | | | | D) REVISE THE WINDOWS OVERHANG DEPTH AND SEPARATION TO | | MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, | | 5TH EDITION (2014). | | | | E) MISSING THE INSPECTION CHECKLIST AS REQUIRED BY SEC. | | R405.4.2 FBC-ENERGY CONSERVATION. | | | | F) PROVIDE THE NAME OF THE INDIVIDUAL COMPLETING THE | | ENERGY CALCULATIONS AS REQUIRED BY SEC. R405.4.2 | | FBC-ENERGY CONSERVATION. | | | | G) BUILDER TO COMPLETE AND PROVIDE THE EPL DISPLAY | | CARD. SEC. R405.4.2 FBC-ENERGY CONSERVATION. | | | | NEW COMMENT: | | H) ITEM #12 SPECIFIES 18 SEER FOR THE COOLING | | EQUIPMENT. FLOOR PLAN M-1 SPECIFIES 15 SEER. REVISE AS | | REQUIRED TO MATCH. SEC. R103.2 FBC-ENERGY CONSERVATION. | | | | NOTE: LABEL FOR WINDOWS AND DOORS U-FACTOR AND SHGC | | FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL BE | | REQUIRED FOR VERIFICATION. | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWINGS. SUBMIT OLD DRAWINGS FOR REFERENCE. DON'T | | STAPLE OLD DRAWINGS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] | | | | 10/26/16 TALKED TO RICHARD BARNES (ARCH.) TO GO OVER | | COMMENTS (# OF PEOPLE , A/C SIZING, A/C SEER). | | | | 10/26/16 TALKED TO TONY PIEDRA (CONTRACTOR) TO GO OVER | | COMMENTS AND PROVISO. HE SAID HE'LL RESUBMIT ALONG WITH | | LANDSCAPE REQUEST. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-10-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-10-03 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-10-03 |
Time |
11:47 |
Sent To |
|
|
Notes |
2016-10-03 11:52:23 | RESIDENTIAL (R3) ADDITION/ALTERATION THIRD BUILDING | | REVIEW CHECKLIST. | | CODE: FBC-5TH EDITION (2014). | | | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS THAT CONTRACTOR MAY SUBMIT REQUESTED INFORMATION | | AFTER THE PERMIT IS ISSUED AND BEFORE INSPECTIONS TO | | AVOID CONFLICTS/DELAYS. REVISION FEES MAY APPLY. | | CONTRACTOR TO ADVICE IF RESUBMITTING INFORMATION NOW OR | | IF PROVISO OPTION IS PREFERRED AT THIS TIME. | | | | | | | | ORIGINAL COMMENT: | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | | | RESPONSE: | | ENERGY CALCULATIONS SUBMITTED: | | A) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | FORM, INCLUDING CORRECT OWNER'S NAME ("HOMEOWNER" IS | | NOT AN OWNER), BUILDER NAME, PERMIT OFFICE AND | | JURISDICTION NUMBER. SEC. R101.5.1.1.2 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | B) REVISE NUMBER OF OCCUPANTS SHOWN UNDER "SPACES" ON | | PAGE 2 OF 4. THIS IS A THREE BEDROOM HOUSE. PROVIDE | | PROOF OF WHY CONSIDERING ONLY ONE OCCUPANT. (THE NUMBER | | OF OCCUPANTS MAY AFFECT THE A/C SIZING LOAD | | CALCULATIONS). SEC. R101.5.1.1.2 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | C) SEC. R806.2 OF FBC-RESIDENTIAL, 5TH EDITION (2014) | | REQUIRES 1/150 ATTIC VENTILATION RATIO. ATTIC | | INFORMATION ON PAGE 2 OF 4 SPECIFIES 1/300 ATTIC | | VENTILATION RATIO. PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW THIS HOUSE COMPLIES WITH THE | | EXCEPTION OF SEC. R806.2 FOR 1/300 ATTIC VENTILATION | | RATIO. OTHERWISE REVISE AS REQUIRED. | | | | D) REVISE THE WINDOWS OVERHANG DEPTH AND SEPARATION TO | | MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, | | 5TH EDITION (2014). | | | | E) MISSING THE INSPECTION CHECKLIST AS REQUIRED BY SEC. | | R405.4.2 FBC-ENERGY CONSERVATION. | | | | F) PROVIDE THE NAME OF THE INDIVIDUAL COMPLETING THE | | ENERGY CALCULATIONS AS REQUIRED BY SEC. R405.4.2 | | FBC-ENERGY CONSERVATION. | | | | G) BUILDER TO COMPLETE AND PROVIDE THE EPL DISPLAY | | CARD. SEC. R405.4.2 FBC-ENERGY CONSERVATION. | | | | NOTE: LABEL FOR WINDOWS AND DOORS U-FACTOR AND SHGC | | FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL BE | | REQUIRED FOR VERIFICATION. | | | | ORIGINAL COMMENT: | | 2- SITE PLAN FOOTPRINT SUBMITTED DOESN'T MATCH PROPOSED | | FLOOR PLAN ON SHEET A-5. REVISE AS REQUIRED TO MATCH. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | RESPONSE: | | REVISE SITE PLAN: THE DRAWING IS NOT CLEAR. THE | | ADDITION WAS BLOCKED BY A DARK BACKGROUND. DRAWING IS | | NOT LEGIBLE. SEC. 107.2.1 CITY AMENDMENTS. | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWINGS. SUBMIT OLD DRAWINGS FOR REFERENCE. DON'T | | STAPLE OLD DRAWINGS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-08-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-08-09 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-08-09 |
Time |
17:35 |
Sent To |
|
|
Notes |
2016-08-09 17:47:44 | | | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING | | REVIEW CHECKLIST. | | CODE: FBC-5TH EDITION (2014). | | | | ORIGINAL COMMENT: | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. PERMIT CAN NOT BE ISSUED | | WITHOUT THE ENERGY CALCULATIONS. SEC. R103.1.1.2 | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | ORIGINAL COMMENT: | | 2- DOORS AND WINDOWS DESIGN PRESSURES SHOWN ON SHEET | | A-7 DON'T MATCH DESIGN PRESSURES SPECIFIED ON SHEET | | A-2. REVISE AS REQUIRED. SEC. R301 OF FBC-RESIDENTIAL, | | 5TH EDITION (2014). | | RESPONSE: | | THE DESIGN PRESSURES WERE DELETED FROM SHEET A-2. THOSE | | DESIGN PRESSURES WERE CORRECT. THEY CORRESPONDED TO | | EXPOSURE "C". THE DESIGN PRESSURES SHOWN ON SHEET A-7 | | DON'T CORRESPOND TO EXPOSURE "C". ALSO, THE DESIGN | | PRESSURES ON THE SMALL OPENINGS CAN NOT BE LOWER THAN | | THE BIGGER OPENINGS. THE SMALLER THE TRIBUTARY AREA, | | THE HIGHER THE DESIGN PRESSURES. REVISE ALL THE DESIGN | | PRESSURES SHOWN ON SHEET A-7. NOTE: MAKE SURE DESIGN | | PRESSURES ARE GIVEN BASED ON THE OPENING SIZE AND | | DISTANCE FROM THE EDGE OF BUILDING. FIGURE R301.2(7) | | REQUIRES 4'-0" MINIMUM AS THE EDGE DISTANCE FOR ALL | | CASES. | | | | ORIGINAL COMMENT: | | 3- PROVIDE COMPLETE WALL SECTION THRU GABLE END SHOWING | | COMPLIANCE WITH SEC. R609.4 OF FBC-RESIDENTIAL, 5TH | | EDITION (2014). | | RESPONSE: | | RESPONSE LETTER STATED THAT "MASONRY WALL IS EXISTING". | | THIS IS NOT CORRECT. THE WEST GABLE END WALL BY THE | | KITCHEN AREA IS NEW. THE "PERSPECTIVE OF GABLE END | | TRUSS" DETAIL SHOWN ON SHEET A-6 DOESN'T MATCH TRUSS | | PLAN SHOWN ON SAME SHEET. THERE IS NO GABLE END TRUSS. | | THERE ARE NOT CONNECTORS SPECIFIED FOR THE 2X4 | | OUTRIGGERS. THERE ARE NOT GABLE END VERTICAL WEBS | | LARGER THAN 4'-0". THEREFORE THE VERTICAL REINFORCEMENT | | WOULDN'T APPLY. SEC. R609.4 OF FBC-RESIDENTIAL REQUIRES | | CONCRETE BLOCK WALL TO BE CONTINUOUS TO THE ROOF LINE. | | OTHERWISE, WOOD FRAME CONSTRUCTION REQUIRES CONFORMANCE | | WITH TABLES R609.4A AND R609.4B AND FIGURE R609.4. SEE | | EXCEPTION FOR SEC. R609.4. PROVIDE A COMPLETE | | SECTION/DETAIL SHOWING HOW PROVIDING A CONTINUOUS LOAD | | PATH FROM THE ROOF TO THE CONCRETE BLOCK WALL. SPECIFY | | ALL CONNECTORS AS REQUIRED BY SEC. R801.2 | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) FIXED WINDOWS AS SHOWN ON PLANS. NONE SUBMITTED AT | | THIS TIME. | | | | ORIGINAL COMMENT: | | B) INSWING ENTRY DOOR AS SHOWN ON PLANS. | | | | RESPONSE: | | THERE ARE TWO DIFFERENT PRODUCT APPROVALS SUBMITTED. | | NONE OF THEM MATCH SINGLE INSWING DOOR TYPE AS SHOWN ON | | PLANS. BOTH PRODUCT APPROVALS ARE FOR DOUBLE DOORS OR | | SINGLE DOOR WITH SIDELITE. NOT SINGLE DOORS ONLY. | | PROVIDE PRODUCT APPROVAL THAT MATCHES PLANS AND DOOR | | SCHEDULE. | | | | NOTE: DOOR SCHEDULE ON SHEET A-8 DOESN'T MATCH | | INFORMATION SHOWN ON PLANS. REVISE AS REQUIRED TO | | MATCH. | | | | ORIGINAL COMMENT: | | C) SHUTTERS IF DOORS AND WINDOWS DON'T HAVE IMPACT | | GLASS. AND PROVIDE COMPLETE INSTALLATION SCHEDULE. | | | | RESPONSE: | | FRENCH DOORS FLORIDA PRODUCT APPROVAL FL16904-R3 | | SUBMITTED IS FOR NON-IMPACT DOORS. NEED TO PROVIDE | | SHUTTERS PRODUCT APPROVAL AND COMPLETE INSTALLATION | | SCHEDULE. | | | | 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | NEW COMMENT: | | 6- SITE PLAN FOOTPRINT SUBMITTED DOESN'T MATCH PROPOSED | | FLOOR PLAN ON SHEET A-5. REVISE AS REQUIRED TO MATCH. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWINGS. SUBMIT OLD DRAWINGS FOR REFERENCE. DON'T | | STAPLE OLD DRAWINGS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-11 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-11 |
Time |
12:17 |
Sent To |
|
|
Notes |
2016-04-11 13:23:48 | 07/27/16: | | TALKED TO MICHELLE (PBC IMPACT FEES) TOTAL NEW A/C AREA | | 754 S.F. AND TOTAL NEW PORCH AREA 247S.F. (AREA | | CALCULATIONS DONE ON PENCIL ON DRAWING A-5). ACCORDING | | TO PAPA AND CITY RECORDS THE BASE AREA WAS 854 S.F. THE | | REST WAS ENCLOSED PORCH, FINISHED PORCH, UNFINISHED | | STORAGE AND FINISHED STORAGE. TOTAL WAS 1360 S.F. SEE | | PAPA). JG. | | | | | | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW | | COMMENTS. | | CODE: FBC-5TH EDITION (2014). | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. | | | | 2- GENERAL NOTES ON SHEET A-1 REFERENCE 2010 FBC. THE | | CURRENT CODE IS THE FBC-RESIDENTIAL, 5TH EDITION | | (2014). REVISE AS REQUIRED. CHAPTER 553 FLORIDA | | STATUTES. | | | | 3- SHEET A-2: | | A) STRUCTURAL DESIGN CRITERIA AND CODES REFERENCE 2010 | | FBC. THE CURRENT CODE IS THE FBC-RESIDENTIAL, 5TH | | EDITION (2014). REVISE AS REQUIRED. CHAPTER 553 FLORIDA | | STATUTES. | | | | B) UPDATE YEAR FOR ALL THE REFERENCE STANDARDS SHOWN ON | | SHEET A-2. SEE CHAPTER 46 FBC-RESIDENTIAL, 5TH EDITION | | (2014) FOR CURRENT YEAR AND REVISE AS REQUIRED. FOR | | EXAMPLE THE CURRENT ACI EDITION IS THE ACI-11 NOT | | ACI-95. | | | | C) FLOOR AND ROOF LIVE LOADS SHOWN ON THE STRUCTURAL | | DESIGN CRITERIA & CODES DOESN'T MATCH LOADS SHOWN ON | | THE PRE-ENGINEERED WOOD TRUSSES NOTES ON SAME SHEET. | | SEE FOOTNOTES "B" AND "G" OF TABLE R301.5 OF | | FBC-RESIDENTIAL, 5TH EDITION (2014) AND REVISE AS | | REQUIRED TO MATCH. | | | | D) THE CURRENT ASCE 7 IS THE ASCE 7-10 NOT ASCE 7-98 | | REVISE THE PRE-ENGINEERED WOOD TRUSSES NOTES. CHAPTER | | 553 F.S. | | | | E) REVISE NAIL SIZE AND TYPE SPECIFIED FOR THE PLYWOOD | | SHEATHING. SEC. R803.2.3.1 REQUIRES 8 D RING SHANK | | NAILS. OR PROVIDE ENGINEER ANALYSIS SHOWING THAT THE | | 10D NAILS ARE EQUIVALENT TO THE 8D RING SHANK NAILS. | | | | 4- SHEET A-4: | | A) UPDATE CODE. THE CURRENT CODE IS THE | | FBC-RESIDENTIAL, 5TH EDITION (2014). REVISE AS | | REQUIRED. CHAPTER 553 FLORIDA STATUTES. ALSO, UPDATE | | THE LOADING NOTES AT THE BOTTOM OF THIS SHEET. | | | | B) CLARIFY THE SOIL BEARING CAPACITY 2500 PSI OR 2500 | | PSF. SEC. 107.2.1 CITY AMENDMENTS. | | | | 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. VALUATION WAS UPDATED TO $90,000. THE | | PERMIT FEE BALANCE IS $2148.70. | | | | 6- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | | | 7- SPECIFY ATTIC ACCESS SIZE AND LOCATION AT NEW | | ADDITION TO COMPLY WITH SEC. R807 OF FBC-RESIDENTIAL, | | 5TH EDITION (2014). | | | | 8- SHEET A-6. SPECIFY BEAMS AT THE NEW COVERED PORCH. | | AND, SPECIFY CONNECTORS AT THE ENDS OF EACH BEAM. SEC. | | R801.2 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 9- DOORS AND WINDOWS DESIGN PRESSURES SHOWN ON SHEET | | A-7 DON'T MATCH DESIGN PRESSURES SPECIFIED ON SHEET | | A-2. REVISE AS REQUIRED. SEC. R301 OF FBC-RESIDENTIAL, | | 5TH EDITION (2014). | | | | 10- PROVIDE COMPLETE WALL SECTION THRU GABLE END | | SHOWING COMPLIANCE WITH SEC. R609.4 OF FBC-RESIDENTIAL, | | 5TH EDITION (2014). | | | | 11- SHEET A-6: SEC. R4409.13.3.2.5 SPECIFIED FOR | | UNVENTED ATTIC APPLIES TO THE HIGH VELOCITY AREAS ONLY. | | IF DESIGNING AN UNVENTED ATTIC, THEN SEE SEC. R806.5 OF | | FBC-RESIDENTIAL, 5TH EDITION (2014) AND REVISE AS | | REQUIRED. | | | | 12- TYPICAL WALL SECTION ON SHEET A-7: | | A) CLEARLY SPECIFY TYPE AND LOCATION OF INSULATION. | | NOTE: COORDINATE WITH UNVENTED ATTIC AND ITEM #11 | | ABOVE. SEC. R806.5 OF FBC-RESIDENTIAL, 5TH EDITION | | (2014). | | | | B) PROVIDE COMPLETE SPECIFICATIONS FOR THE TIE BEAM. | | SEC. R801.2 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 13- PROVIDE ICC EVALUATION REPORT FOR THE TYPE OF | | INSULATION SPECIFIED ON ITEM #12(A) ABOVE. SEC. R316 OF | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 14- ROOF FRAMING NOTES ON SHEET A-7 REFERENCE 2010 FBC. | | THE CURRENT CODE IS THE FBC-RESIDENTIAL, 5TH EDITION | | (2014). REVISE AS REQUIRED. CHAPTER 553 FLORIDA | | STATUTES. | | | | 15- CLEARLY SPECIFY TYPE AND SIZE OF EXISTING BEDROOM | | WINDOWS TO BE REPLACED AND TYPE AND SIZE OF PROPOSED | | WINDOWS TO VERIFY EGRESS REQUIREMENTS OF SEC. 704 OF | | FBC-EXISTING BUILDING, 5TH EDITION (2014). | | | | 16- SPECIFY CARBON MONOXIDE ALARM BY THE NEW MASTER | | BEDROOM AS REQUIRED BY SEC. R315 OF FBC-RESIDENTIAL, | | 5TH EDITION (2014). | | | | 17- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) METAL ROOF AS SPECIFIED ON PLANS. | | | | B) ALL WINDOW TYPES AS SPECIFIED ON PLANS. | | | | C) INSWING ENTRY DOOR AS SHOWN ON PLANS. | | | | D) OUTSWING FRENCH DOORS AS SHOWN ON PLANS. | | | | E) ALL STRUCTURAL CONNECTORS SPECIFIED ON PLANS. | | PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER PAGE | | AND PAGE SHOWING THE CONNECTOR OR LIST THE FLORIDA | | PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED | | CONNECTOR. | | | | F) PRECAST LINTELS (IF SPECIFIED ON PLANS) | | | | G) SHUTTERS IF DOORS AND WINDOWS DON'T HAVE IMPACT | | GLASS. AND PROVIDE COMPLETE INSTALLATION SCHEDULE. | | | | 18- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 | | CITY AMENDMENTS. | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWINGS. SUBMIT OLD DRAWINGS FOR REFERENCE. DON'T | | STAPLE OLD DRAWINGS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-10-11 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-10-11 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-10-11 |
Time |
10:59 |
Sent To |
|
|
Notes |
2016-10-11 11:01:18 | PROVISO- SHOW ON PLANS THE AIC RATING OF SERVICE AND | | PANEL EQUIPMENT |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-08-09 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-08-09 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-08-09 |
Time |
08:02 |
Sent To |
|
|
Notes |
2016-08-09 08:07:27 | 2ND ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA RESIDENTIAL BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | PENDING COMMENTS AND NEW PER SCOPE NOW SHOWN REGARDING | | INSTA HOT 18KV: | | | | 2. PROVIDE AIC CALCULATIONS FOR NEW SERVICE PER FBC RES | | E3606 | | 1. SHOW AIC RATING ON PANEL SCHEDULE. FBC RES E3606 | | 2. CORRECT INSTA HOT 18KV ON CALCULATION SUBMITTED, ON | | PANEL SCHEDULE AND LOADS. PANEL SCHEDULE SHOWS 4500W. | | CALCULATIONS SHOW 5000, CORRECT A SUBMIT REFLECTING | | 18,000W. VERIFY 200AMP SERVICE IS SUFFICIENT. | | 6. FEEL FREE TO CONTACT ME AT THE NUMBER BELOW SHOULD | | YOU HAVE ANY QUESTIONS OR CONCERNS. | | | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-03-12 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-03-12 |
Time |
05:06 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-03-12 |
Time |
05:06 |
Sent To |
|
|
Notes |
2016-03-12 05:17:23 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA RESIDENTIAL BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | COMMENTS: | | | | 1. UPDATE ALL APPLICABLE CODES ON GENERAL NOTES TO | | REFLECT NEW FBC 2014 5TH EDITION SET AND NFPA 70 NEC | | 2011. | | 2. PROVIDE AIC CALCULATIONS FOR NEW SERVICE PER FBC RES | | E3606 | | 3. PROVIDE A NOTE TO INDICATE THE REQUIREMENTS OF FBC | | RES 404.1- 75% OF LAMPS TO BE HIGH EFFICACY LAMPS. | | 4. SHOW ON PANEL SCHEDULE THE CONDUCTOR SIZE FOR THE | | WATER HEATER. NEC 310.15B16 | | 5. PER FBC RES E3706, SHOW AND LABEL BRANCH CIRCUITS ON | | PANEL BOARDS SPECIFIC AREA AS TO WHAT IT SERVES. | | GENERAL LIGHTING DESIGNATION WILL NOT SUFFICE. MUST BE | | CLEAR AND EVIDENT AS TO WHAT IT ENERGIZES. | | 6. FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL | | FREE TO CONTACT ME AT THE NUMBER BELOW SHOULD YOU HAVE | | ANY QUESTIONS OR CONCERNS. | | | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2017-01-13 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-01-13 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-01-05 |
Time |
11:00 |
Sent To |
|
|
Notes |
2017-01-06 11:00:59 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-11-22 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-11-22 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-11-10 |
Time |
10:01 |
Sent To |
|
|
Notes |
2016-11-15 19:39:07 | ROUTED TO JULIO GOMEZ 11/15/2016 - JORGE V. | 2016-11-14 10:02:04 | RESUB ROUTED TO JVALIDO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-10-25 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-10-25 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-09-27 |
Time |
13:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-08-24 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-08-24 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-07-29 |
Time |
11:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-11 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-03-08 |
Time |
13:39 |
Sent To |
|
|
Notes |
2016-03-12 05:17:54 | 3/12 TO R09 | 2016-03-08 13:39:48 | R09 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2016-08-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-08-09 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-08-09 |
Time |
18:25 |
Sent To |
|
|
Notes |
2016-08-09 18:26:16 | $180.65 PAID. MU-2016-19095. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-11 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-11 |
Time |
13:23 |
Sent To |
|
|
Notes |
2016-04-11 13:24:14 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
P |
Date |
2016-11-18 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-11-18 |
Time |
16:31 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2016-11-18 |
Time |
16:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
F |
Date |
2016-10-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-10-05 |
Time |
09:14 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2016-10-05 |
Time |
09:14 |
Sent To |
|
|
Notes |
2016-10-05 09:17:26 | FAILED | | | | THE VALUE OF THE CONSTRUCTION ($90,000) EXCEEDS 50% OF | | THE STRUCTURE'S VALUE ($88,662**) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2017-01-12 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2017-01-12 |
Time |
18:02 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2017-01-12 |
Time |
17:49 |
Sent To |
|
|
Notes |
2017-01-11 11:07:14 | REVISED LOAD CALCULATIONS SUBMITTED. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2016-11-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-11-21 |
Time |
17:47 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-11-21 |
Time |
17:10 |
Sent To |
|
|
Notes |
2016-11-21 14:38:39 | REVISED DRAWING SUBMITTED. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2016-11-15 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-11-15 |
Time |
19:37 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-11-15 |
Time |
19:37 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2016-10-24 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-10-24 |
Time |
17:57 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-10-24 |
Time |
17:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-08-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-08-31 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-08-31 |
Time |
15:47 |
Sent To |
|
|
Notes |
2016-08-31 16:26:28 | | | FLORIDA ENERGY CODE FBC 2014 | | | | (1) PROVIDE ENERGY CALCULATIONS AND HEAT LOAD | | CALCULATIONS AS PER FBC ENERGY CODE 2014. | | | | JORGE VALIDO | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | [email protected] | | 561-805-6716 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-04-04 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-04-04 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-04-04 |
Time |
14:58 |
Sent To |
|
|
Notes |
2016-04-04 15:13:38 | CITY OF WEST PALM BEACH | | LOCAL AMENDMENTS TO THE | | FLORIDA BUILDING CODE (FBC) 2010 | | CHAPTER 1 ADMINISTRATION | | | | 107.2.1 | | | | (1)PROVIDE EXHAUST IN BATHROOMS AS PER FBC 2014 SHOW | | DUCT ROUTE WITH SIZES OF DUCT AND TERMINATION | | LACATION.. | | (2)PROVIDE SPECIFIC INFORMATION FOR THE NEW AHU AND | | CONDENSER ( MANUFACTURER, MODEL #, TOTAL BTU, SENSIBLE | | BTU, ETC...). | | (3)PROVIDE DIMENSIONS OF SUPPLY AND RETURN GRILLS. | | (4)PROVIDE LOCATION OF RETURN GRILL WITH DIMENSIONS IN | | COMMON AREA FOR RETURN TO AHU. | | (5)PROVIDE CONDENSER TIE DOWN DETAIL. | | (6)PROVIDE AHRI SHEET. | | (7)SHOW LOCATION OF FANTECH UNIT IN GARAGE. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-10-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-10-24 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-10-24 |
Time |
09:26 |
Sent To |
|
|
Notes |
2016-10-03 14:23:38 | NEW DRAWING SUBMITTED. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-07-30 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-07-30 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-07-30 |
Time |
10:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-03-17 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-03-17 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-03-17 |
Time |
16:38 |
Sent To |
|
|
Notes |
2016-03-17 16:43:11 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. PLUMBING NOTES REFERENCE FBC 2010 IT SHALL BE FBC | | 2014 5TH EDITION. | | 2. SHOW LOCATION TYPE MAKE MODEL OF WATER HEATER. | | PER WPB AMEND TO FBC SEC 107.2.1 | | 3. ADD PLUMBING WORK TO APPLICATION. | | PER WPB AMEND TO FBC SEC 107.2.1 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2016-08-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-08-10 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-08-10 |
Time |
13:10 |
Sent To |
|
|
Notes |
2016-08-10 13:11:32 | METAL ROOF NOA 12-0227.07. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2016-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-11 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-11 |
Time |
17:39 |
Sent To |
|
|
Notes |
2016-04-11 17:40:04 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) METAL ROOF AS SPECIFIED ON PLANS. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2016-10-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-10-05 |
Time |
08:50 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2016-10-05 |
Time |
08:50 |
Sent To |
|
|
Notes |
2016-10-03 14:24:33 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-08-16 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-08-16 |
Time |
10:16 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2016-08-16 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-03-18 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-03-18 |
Time |
17:29 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2016-03-18 |
Time |
17:29 |
Sent To |
|
|
Notes |
2016-03-18 17:33:25 | FAILED | | | | 1) PROVIDE A SITE PLAN THAT SHOWS THE SETBACK | | DIMENSIONS OF THE NEW ADDITION TO THE NORTH, WEST AND | | SOUTH PROPERTY LINES AND THE AC UNIT TO THE WEST | | PROPERTY LINE. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|