Plan Review Details - Permit 16030202
Plan Review Stops For Permit 16030202 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-04-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-04-19 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-04-19 |
Time |
07:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-03-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-03-31 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-03-31 |
Time |
10:47 |
Sent To |
|
|
Notes |
2016-03-31 15:20:17 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE INFORMATION THAT YOU SUBMITTED FOR THE SIMPSON | | A33 CONNECTORS SPECIFY THE ALLOWABLE LATERAL LOADS (F1 | | AND F2). NO ALLOWABLE UPLIFT LOADS ARE LISTED. THE | | FASTENERS THAT WERE SPECIFIED ON THE PLANS ARE NOT THE | | SAME AS THE ONES LISTED IN THE SIMPSON CATALOG PAGE | | THAT YOU SUBMITTED. REVISE THE DRAWINGS AND SUBMIT | | PRODUCT APPROVALS FOR CONNECTORS WITH ALLOWABLE UPLIFT | | LOADS. DCA RULE 9N-3, R301.1 & R802.2 | | | | 2) FBC R301.1 INDICATE WHICH ONE OF THE THREE EMBED | | DEPTHS LISTED FOR TECTUM DECKS IN THE TRUFAST CHART ON | | THE FASTENER SHEET THAT WAS SUBMITTED IS TO BE USED. | | BASED ON THE DRAWINGS THERE IS ONE FASTENER FOR EVERY | | FOUR SQUARE FEET OF ROOF AREA. FOR EXAMPLE THE FASTENER | | WITH THE 2.5" EMBEDMENT IS 595 LBS. DIVIDED BY 4 SQUARE | | FEET = 148.45 POUNDS PER SQUARE FOOT. THE PLANS STATE | | THAT THE WORST CASE IS -111 PSF. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-03-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-03-07 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-03-07 |
Time |
07:24 |
Sent To |
|
|
Notes |
2016-03-07 09:05:07 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THIS PROJECT IS THE CONSTRUCTION OF A NEW ROOF | | SYSTEM BUILT OVER AN EXISTING ROOF. THE ROOF FRAMING | | AND SHEATHING PORTION OF THIS PROPOSED WORK WILL | | REQUIRE A FLORIDA LICENSED GENERAL, BUILDING OR | | RESIDENTIAL CONTRACTOR. FS489 | | | | 2) SUBMIT PRODUCT APPROVALS FOR THE SIMPSON A33 | | CONNECTORS THAT INDICATE THE ALLOWABLE UPLIFT LOADS. | | THESE ANGLE CLIPS DO NOT APPEAR TO BE SUITABLE FOR | | UPLIFT APPLICATIONS. DCA RULE 9N-3, R301.1 & R802.2 | | | | 3) PROVIDE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS | | FOR THE TRUFAST TECTUM FASTENERS THAT WILL BE USED TO | | ATTACH THE 2" X 4" P.T. SLEEPERS TO THE EXISTING TECTUM | | DECK. FBC R301.1 | | | | 4) SPECIFY THE REQUIRED EMBED DEPTH AND THE PULL OUT | | VALUE FOR THE TRUFAST TECTUM FASTENERS. FBC R301.1 | | | | 5) SPECIFY THE REQUIRED UPLIFT OF THE NEW ROOF FRAMING | | SYSTEM AND PROVIDE CALCULATIONS TO SHOW THAT THE | | PROPOSED CONNECTORS ARE ADEQUATE TO PROVIDE A COMPLETE | | LOAD PATH. FBCR 301.1 & FBC 107.2.1.3 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-04-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-04-19 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-04-14 |
Time |
14:40 |
Sent To |
|
|
Notes |
2016-04-14 14:40:28 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-03-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-03-31 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-03-29 |
Time |
14:52 |
Sent To |
|
|
Notes |
2016-03-30 14:52:27 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-03-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-03-07 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-03-04 |
Time |
13:18 |
Sent To |
|
|
Notes |
2016-03-04 13:19:05 | RMCDOUGAL |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |