Plan Review Details - Permit 16021035
Plan Review Stops For Permit 16021035
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2016-05-19 Cont ID  
Sent By tmoore Date 2016-05-19 Time 16:07 Rev Time 0.00
Received By tmoore Date 2016-05-19 Time 16:03 Sent To  
Notes
2016-05-19 16:07:32THE F.P.L. SERVICE DROP HAS FINALLY BEEN CUT. WE CAN
 NOW SAFELY DEMOLISH AND I CAN ISSUE PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2016-05-05 Cont ID  
Sent By tmoore Date 2016-05-05 Time 16:11 Rev Time 0.00
Received By tmoore Date 2016-05-05 Time 15:54 Sent To  
Notes
2016-05-05 16:11:53HAVE ALL UTILITY RELEASES, ASBESTOS ABATEMENT SURVEY,
 REVIEWS AND CAPPINGS. BUT F.P.L. HAS NOT CUT THE
 ELECTRICAL SERVICE ENTRANCE CABLE DROP. IT IS STILL
 CONNECTED TO THE TRANSFORMER ON THE POLE.
 AS SOON AS FPL MAKES THE CUT, THE PERMIT CAN BE ISSUED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-04-30 Cont ID  
Sent By tmoore Date 2016-04-30 Time 09:46 Rev Time 0.00
Received By tmoore Date 2016-04-30 Time 09:39 Sent To  
Notes
2016-04-30 09:44:23NO RESPONSE TO REQUEST FOR PHONE CALL BACK. NUMBER ON
 APPLICATION IS #561-719-4886, TRIED #561-697-4490 THIS
 TIME. WE STILL HAVE A LIVE FPL DROP CONNECTED TO THE
 REAR OF THE THEATER. I STILL HAVE NOT RECEIVED AN
 ASBESTOS ABATEMENT SURVEY, REQUIRED FOR COMMERCIAL
 DEMOS, FROM CONTRACTOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-04-16 Cont ID  
Sent By tmoore Date 2016-04-16 Time 09:36 Rev Time 0.00
Received By tmoore Date 2016-04-16 Time 09:24 Sent To  
Notes
2016-04-16 09:36:07APPLICATION IS MISSING;
  
 1) WATER METER PULL CONFIRMATION FROM UTILITIES, PLEASE
 REQUEST THAT DIRECTLY FROM THEM. 1ST FLOOR CITY HALL.
  
 2) SEWER LATERAL PERMIT PULLED, LATERAL CAPPED, AND
 FINAL INSPECTION PASSED.
  
 3) COPY OF ASBESTOS ABATEMENT SURVEY. REQUIRED BY
 HEALTH DEPARTMENT AND OUR DEMO SPECS FOR COMMERCIAL
 BUILDINGS.
  
 4) HYDRANT BACKFLOW, OR SMALLER BACKFLOW WITH HOSE BIB,
 OR CONTRACTOR'S METHOD OF KEEPING DEMO WET.
  
  
 TOM M. @ 561-805-6669
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2016-04-13 Cont ID  
Sent By Mgonzale Date 2016-04-13 Time   Rev Time 1.00
Received By mgonzale Date 2016-04-13 Time   Sent To B
Notes
2016-04-13 10:27:57PROVISO: USE POLLUTION PREVENTION AS PER MUNICODE
 SECTION 94-450.
 WWW.MUNICODE.COM
  
 IT IS PARAMOUNT THAT THE ROW BE SECURED; THIS CAN BE
 DONE THRU A ROW PERMIT, YOU MAY CONTACT GORDON PATRIE
 AT (561) 494-1082 OR
 MAKE RIGHT-OF-WAY APPLICATION FOR SIDEWALK / ROAD
 CLOSURE AS REQUIRED AT 1ST FLOOR CITY HALL -
 CONSTRUCTION SERVICES DEPARTMENT..
  
 CALL FOR LOCATES - CALL 811 BEFORE DIG / DEMO. CITY
 SANITARY SEWER MANHOLE AND PIPE IN THE VICINITY OF
 DEMO.
  
 IMPORTANT MESSAGE: AS OF DECEMBER 20, 2015 THE CITY OF
 WEST PALM BEACH CROSS-CONNECTION CONTROL MANUAL HAS
 BEEN REVISED, MAKING KNOWN THAT "ALL BACKFLOW DEVICES
 MUST BE LEAD FREE."
 FOR MORE INFORMATION REFER TO THE LINK: HTTP://WPB.ORG/
 DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLICATIONS/BACKFLO
 W-CROSS-CONNECTION-CONTROL-MANUAL
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-03-01 Cont ID  
Sent By tmoore Date 2016-05-05 Time 16:12 Rev Time 0.00
Received By fmittner Date 2016-03-01 Time 09:40 Sent To ENG
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-05 Cont ID  
Sent By tmoore Date 2016-05-05 Time 16:12 Rev Time 0.00
Received By tmoore Date 2016-05-05 Time 16:12 Sent To HIST
Notes
***NONE***