2016-03-03 09:57:30 | RESIDENTIAL (R3) REVISION, BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- NEED ROOFING SUB-PERMIT. FOR NEW PORCH AND REQUEST | | PROPER INSPECTIONS. SEC. 105.1 CITY AMENDMENTS. | | | | 2- FLAT ROOF ON PORCH: | | ENGINEER OF RECORD IS CERTIFYING THAT THE FLAT ROOF WAS | | INSTALLED IN ACCORDANCE WITH FLORIDA BUILDING CODE CODE | | PRODUCT APPROVAL FL16709-R2. ENGINEER TO IDENTIFY WHICH | | APPROVED ASSEMBLY FROM FLORIDA PRODUCT APPROVAL | | FL16709-R2 WAS INSTALLED (THERE ARE 5 SYSTEMS W-1 THRU | | W-5). AND, SPECIFY WHICH BASE SHEET FASTENING SPACING | | WAS INSTALLED FOR THE PERIMETER AND CORNER AREAS. NOTE: | | CLARIFY IS THE INSTALLED SYSTEM IS INSULATED OR | | NON-INSULATED SYSTEM. SEC. R301 | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected]. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-05-24 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-05-24 |
Time |
08:21 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-05-24 |
Time |
08:21 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-05-02 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-05-02 |
Time |
19:24 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-05-02 |
Time |
18:33 |
Sent To |
|
|
Notes |
2016-05-02 19:40:31 | ELECTRICAL REVIEW COMMENTS | | | | CORRECTIONS REQUIRED: | | THERE CONTINUES TO BE NUMEROUS ABNORMALITIES WITH THIS | | SUBMITTAL. IT IS NOT MY INTENT TO GENERATE A PUNCH FOR | | THE DESIGNER. JUST TO NAME A FEW OF THE DEFICIENCIES | | NOTED, THE SCOPE OF WORK AS DEFINED FOR THIS REVISION | | ALONG WITH THE SCOPE OF WORK DESCRIBED ON THE MASTER | | PERMIT DO NOT MATCH WHAT IS INDICATED ON THE SUBMITTED | | DRAWINGS. THOUGH THE RISER DIAGRAM HAS BEEN REVISED TO | | INDICATE A SINGLE METER, THE ELECTRICAL PANELS | | REFERENCED ARE NOT SHOWN ON THE FLOOR PLANS. YOU | | SUBMITTED LOAD CALCS FOR A 150 AMP PANEL NOT SHOWN ON | | THE RISER DIAGRAM. THE RISER DIAGRAM IS INDICATED TO BE | | 300 AMP WITH A 200 AMP RATED CONDUCTOR. | | YOU NEED TO SUBMIT A SITE SPECIFIC RISER DIAGRAM AS | | INDICATED IN NEC 215.5. | | THE ELECTRICAL OUTLETS AND LIGHTING AS SHOWN ON THE | | FLOOR PLAN FOR BLDG. 1 FAIL TO MEET MINIMUM CODE | | REQUIREMENTS AS WELL. VERIFY OUTLET SPACING AS | | INDICATED IN NEC 210.52. PLEASE REMEMBER TO PROVIDE | | PROPER ILLUMINATION ABOUT THE ELECTRICAL PANEL. | | PLEASE NOTE THAT THIS IS NOT THE FIRST TIME THIS COMES | | UP FOR REVIEW. THE MASTER PERMIT WAS REVIEWED 6 TIMES | | AND STILL NEVER WAS PROPERLY PRESENTED. | | AT THIS TIME I WOULD LIKE TO MAKE YOU AWARE OF THE | | FOLLOWING: | | PURSUANT TO FL ?553.80, THE 4TH SUBMITTAL FOR A PERMIT | | WHICH REFLECTS FAILURE TO CORRECT A DEFICIENCY | | PREVIOUSLY SPECIFICALLY AND CONSISTENTLY IDENTIFIED ON | | ALL PRIOR SUBMITTALS MUST RESULT IN THE ASSESSMENT OF A | | PENALTY OF 3 TIMES THE PLAN REVIEW FEE IN ADDITION TO | | THE NORMAL FEE | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-04-12 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-04-12 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-04-12 |
Time |
13:54 |
Sent To |
Z |
|
Notes |
2016-04-12 15:09:00 | ELECTRICAL REVIEW COMMENTS | | REVIEWED FOR COMPLIANCE WITH: | | 2010 FLORIDA BLDG. CODES; 2008 NEC | | | | CORRECTIONS REQUIRED | | ACCORDING TO THE PROPERTY APPRAISER THIS SITE IS ZONED | | AS SINGLE FAMILY AND UNTIL ZONING TELLS ME OTHERWISE A | | SECOND OR THIRD ELECTRICAL METER TO THIS SITE WILL NOT | | BE AUTHORIZED. IF MORE THAN A SINGLE METER IS | | AUTHORIZED, FPL STANDARDS PERMIT ONLY A SINGLE DROP PER | | LOT AND NEC HAS FURTHER LIMITATIONS SUCH AS THE | | GROUPING OF ALL DISCONNECTS; AND A SINGLE SERVICE TO A | | BLDG. AS WELL. THEREFORE, YOU SHALL REVISE THE SERVICE | | RISER DIAGRAM ACCORDINGLY. | | THAT BEING SAID AND ADDRESSED, THERE ARE FURTHER ISSUES | | TO COMPLY WITH SHOULD THE SERVICE MATTER GET SOLVED. | | NEC 314.27(D) REQUIRES THAT ALL CEILING BOXES USED TO | | SUPPORT PADDLE FANS BE LISTED FOR THE PURPOSE. | | NEC 110.26(D) REQUIRES THERE BE PROPER ILLUMINATION | | ABOUT THE ELECTRICAL PANEL. | | NEC 210.52(F) REQUIRES THAT A LAUNDRY CIRCUIT BE | | PROVIDED AND INCLUDED IN THE LOAD CALCS AND INCLUDED IN | | THE PANEL SCHEDULE. | | FBC-E SECTION 404.1 REQUIRES THAT A MINIMUM OF 50% OF | | THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES | | SHALL BE HIGH-EFFICACY LAMPS. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | | 2016-03-24 12:46:06 | THIS FILE WAS NOT IN R11 WHEN I WENT FOR IT. | 2016-03-03 10:36:59 | NEW REVISED DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2016-06-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-06-01 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-06-01 |
Time |
16:57 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2016-04-27 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-04-27 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-04-27 |
Time |
12:39 |
Sent To |
|
|
Notes |
2016-04-27 12:40:06 | E-MAIL DOCUMENTATION RECEIVED FROM OWNER CONFIRMING NOT | | OBSCURE GLASS |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2016-04-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-04-08 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-04-08 |
Time |
14:23 |
Sent To |
|
|
Notes |
2016-04-08 14:24:17 | HISTORIC DISTRICT-OBSCURED WINDOWS NOT PERMITTED. | | QUESTIONS CONTACT FRIEDERIKE MITTNER AT 822-1457. | 2016-03-03 10:36:48 | NEW REVISED DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
vperez |
Date |
|
Time |
08:21 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-05-24 |
Time |
08:21 |
Sent To |
|
|
Notes |
2016-05-23 12:51:01 | RESUB OF REVISION ROUTED TO VPEREZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-05-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-05-05 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-28 |
Time |
14:34 |
Sent To |
|
|
Notes |
2016-04-28 14:34:33 | RESUB OF REVISION ROUTED TO MALBARRAN |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-04-27 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-04-27 |
Time |
12:56 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-03-03 |
Time |
10:35 |
Sent To |
|
|
Notes |
2016-03-03 10:35:58 | REVISION SENT TO R11 SHELF FOR REVIEW. JG. | 2016-02-26 13:40:23 | REVISION ROUTED TO JGOMEZ |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-06-03 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-06-03 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-06-03 |
Time |
14:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-04-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-04-11 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-04-11 |
Time |
10:06 |
Sent To |
|
|
Notes |
2016-03-03 10:36:38 | NEW REVISED DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-04-25 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-04-25 |
Time |
17:35 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-04-25 |
Time |
17:35 |
Sent To |
|
|
Notes |
|
|