Plan Review Stops For Permit 16020992 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-13 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-13 |
Time |
12:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-06-13 |
|
|
Cont ID |
|
Sent By |
gearl |
Date |
2016-06-13 |
Time |
|
Rev Time |
0.00 |
Received By |
gearl |
Date |
2016-06-13 |
Time |
14:12 |
Sent To |
|
|
Notes |
2016-06-13 14:29:57 | MAREDK BUILDING BY MISTAKE GEORGE EARL |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-03-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-03-22 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-03-22 |
Time |
08:38 |
Sent To |
|
|
Notes |
2016-03-22 10:44:11 | 1ST REVIEW: FBC 2014 5TH ED | | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | 1. PROVIDE SITE PLAN. | | 2. PROVIDE ENERGY CALC'S. | | 3. PROVIDE DETAIL FOR NEW MASONRY OPENINGS IN EXISTING | | CMU WALLS. | | 4. PROVIDE SHORING PLAN FOR REMOVAL OF EXISTING CMU | | LOAD BEARING WALLS PER NOTE 2, PG. S-1. | | 5. SPECIFY SPACING OF HORIZ. JOINT RE-INFORCING @ 8" | | CMU WALLS PER DETAIL 5, PG. S-1. | | 6. IDENTIFY LENGTH OF #4 DOWELS IN NOTE # 2, FOUNDATION | | PLAN, PG. S-1. | | 7. IMPACT FEES. | | 8. PROVIDE FLOOR PLAN. IDENTIFY INTENDED USE OF SPACE. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | FBC 107.3.5.3 ? PROVIDE A SITE PLAN TO DEMONSTRATE | | SETBACKS AND BUILDING SEPARATION. | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURN STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-06-13 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-06-13 |
Time |
18:40 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-06-13 |
Time |
18:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-03-03 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-03-03 |
Time |
09:22 |
Sent To |
|
|
Notes |
2016-03-03 09:34:17 | 1ST REVIEW 2014 5TH FBC ED. NEC 2011/RESIDENTIAL | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6713 | | [email protected] | | | | | | -PLEASE PROVIDE A ELECTRICAL FLOOR PLAN SHOWING NEW | | WORK AND EXISTING LOCATION OF ELECTRICAL SYSTEM. WBA | | 107 | | | | FBC- 107.3.5.3 ? ELECTRIC SERVICE RISER WITH WIRE | | SIZES, CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE | | LOAD CALCULATIONS, PANEL SCHEDULES AND SHOW CIRCUITS ON | | FLOOR PLAN. | | | | SMOKE/CARBON ALARMS REQUIRED PER RESIDENTIAL CODE | | SECTIONS 314 & 315 | | | | OUTLETS TO BE AFCI PROTECTED PER NEC 210.12 B AND | | RECEPTACLES MUST BE TAMPER RESISTANT RATED ACCORDING TO | | NEC 406.11 | | | | PROVIDE GFCI PROTECTION IN THOSE AREAS COVERED IN NEC | | 210.8 A | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-13 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-12 |
Time |
15:38 |
Sent To |
|
|
Notes |
2016-07-12 15:38:42 | IMPACT FEES ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-22 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-05-31 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-03-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-03-22 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-02-25 |
Time |
11:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2016-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-13 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-13 |
Time |
12:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-03-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-03-22 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-03-22 |
Time |
10:28 |
Sent To |
|
|
Notes |
2016-03-22 10:31:14 | 1ST REVIEW: FBC 2014 5TH ED | | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURN STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-06-22 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-06-22 |
Time |
14:03 |
Sent To |
R |
|
Notes |
2016-06-22 15:39:07 | THIS PERMIT WAS ISSUED WITHOUT ANY MECHANICAL A/C | | REQUIREMENTS. IF AN INSPECTOR SEES ANY MECHANICAL A/C | | WORK DONE PLEASE NOTIFY THE BUILDING OFFICIAL, PLACE A | | STOP WORK ORDER AND APPLY A FOUR TIMES THE PERMIT FEE. | | | | JORGE VALIDO | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | [email protected] | | 561-805-6716 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-03-22 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-03-22 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-03-22 |
Time |
10:47 |
Sent To |
|
|
Notes |
2016-03-22 10:59:41 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | FBC- 107.3.5.3 ? PROVIDE A MECHANICAL PLAN TO SHOW | | SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER FBC-R | | M15. | | | | PROVIDE AN ENERGY SUBMITTAL. | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | PROVIDE AN EQUIPMENT SIZING CALCULATION IF APPLICABLE. | | | | R403.6.1 EQUIPMENT SIZING. | | HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN | | ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT | | LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR | | OTHER APPROVED HEATING AND COOLING CALCULATION | | METHODOLOGIES, BASED ON BUILDING LOADS FOR THE | | DIRECTIONAL ORIENTATION OF THE BUILDING. THE | | MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR | | UNITS (IF SPLIT SYSTEM) SHALL BE SUBMITTED ALONG WITH | | THE SENSIBLE AND TOTAL COOLING CAPACITIES AT THE DESIGN | | CONDITIONS DESCRIBED IN SECTION R302.1. THIS CODE DOES | | NOT ALLOW DESIGNER SAFETY FACTORS, PROVISIONS FOR | | FUTURE EXPANSION OR OTHER FACTORS WHICH AFFECT | | EQUIPMENT SIZING. SYSTEM SIZING CALCULATIONS SHALL NOT | | INCLUDE LOADS CREATED BY LOCAL INTERMITTENT MECHANICAL | | VENTILATION SUCH AS STANDARD KITCHEN AND BATHROOM | | EXHAUST SYSTEMS. | | | | R403.6.1.1 COOLING EQUIPMENT CAPACITY. | | COOLING ONLY EQUIPMENT SHALL BE SELECTED SO THAT ITS | | TOTAL CAPACITY IS NOT LESS THAN THE CALCULATED TOTAL | | LOAD, BUT NOT MORE THAN 1.15 TIMES GREATER THAN THE | | TOTAL LOAD CALCULATED ACCORDING TO THE PROCEDURE | | SELECTED IN SECTION 403.6, OR THE CLOSEST AVAILABLE | | SIZE PROVIDED BY THE MANUFACTURER?S PRODUCT LINES. THE | | CORRESPONDING LATENT CAPACITY OF THE EQUIPMENT SHALL | | NOT BE LESS THAN THE CALCULATED LATENT LOAD. | | | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-06-13 |
|
|
Cont ID |
|
Sent By |
gearl |
Date |
2016-06-13 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
gearl |
Date |
2016-06-13 |
Time |
14:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-03-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-03-11 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-03-11 |
Time |
12:07 |
Sent To |
|
|
Notes |
2016-03-11 12:24:09 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. PROVIDE PLUMBING RISER DIAGRAM WITH PIPE SIZES. | | PER WPB AMEND.TO FBC SEC 107.3.5.3(11) | | 2. PROVIDE MANUFACTURE SPEC SHEETS FOR WATER HEATER. | | 3. VALUATION OF ALL WORK ON MAIN PERMIT APPLICATION | | APPEARS TO BE LOW PLEASE PROVIDE A DETAILED QUANTITY | | ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | PER WPB AMEND. TO FBC SEC.109.3 BUILDING PERMIT | | VALUATIONS. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-22 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-06-22 |
Time |
16:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2016-03-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-03-22 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-03-22 |
Time |
10:27 |
Sent To |
|
|
Notes |
2016-03-22 10:28:44 | 1ST REVIEW: FBC 2014 5TH ED | | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | PROVIDE ROOF SHEATHING FASTENER SCHEDULE PER DESIGN | | WIND LOAD CALC'S. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-06-10 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2016-06-16 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
llouie |
Date |
2016-06-10 |
Time |
16:19 |
Sent To |
M |
|
Notes |
2016-06-10 16:40:46 | ZONING PASSED - ALL COMMENTS BELOW ADDRESSED ON | | 6/16/16. | | | | | | FAILED ON 6/10/16 | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) REPEAT COMMENT FROM 3/10/16: PROVIDE AN UPDATED | | SURVEY OF THE PROPERTY. A SURVEY OF THE PROPERTY IS | | NEEDED TO ENSURE THAT THE LOT DIMENSIONS AND EXISTING | | STRUCTURES ILLUSTRATED IN THE SITE PLAN ARE ACCURATE | | AND ARE NOT IN CONFLICT WITH ANY EASEMENTS. | | | | [PER HDM ARCHITECTURE, INC. RESPONSE LETTER TO ZONING'S | | COMMENTS, DATED 4/10/16, THE GENERAL CONTRACTOR WILL | | PROVIDE THE UPDATED SURVEY; HOWEVER, NO SURVEY WAS | | PROVIDED WITH THE RESUBMITTAL.] | | | | PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE | | @ (561) 822-1458 IF YOU HAVE QUESTIONS. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-03-10 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2016-03-10 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2016-03-10 |
Time |
15:48 |
Sent To |
|
|
Notes |
2016-03-10 16:31:19 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS IN WRITING AND/OR | | ON THE PLANS WHERE APPLICABLE: | | | | 1.) PROVIDE AN UPDATED SURVEY OF THE PROPERTY. | | | | 2.) A SITE PLAN IS REQUIRED. THE SCOPE OF WORK INCLUDES | | THE EXPANSION OF THE EXISTING STRUCTURE. SETBACK | | DIMENSIONS, FROM THE PROPOSED BUILDING FOOTPRINT TO THE | | PROPERTY LINES REQUIRED TO DETERMINE IF THE EXPANSION | | MEETS SETBACK REQUIREMENTS OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS. | | | | 3.) PROVIDE HEIGHT OF THE BUILDING TO THE TOP OF THE | | ROOF PITCH. | | | | PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE | | @ (561) 822-1458 IF YOU HAVE QUESTIONS. | | |
|
|