Plan Review Details - Permit 16020967
Plan Review Stops For Permit 16020967
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-04-05 Cont ID  
Sent By cthroop Date 2016-04-05 Time 13:24 Rev Time 0.00
Received By cthroop Date 2016-04-05 Time 13:24 Sent To  
Notes
2016-04-05 13:26:101ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 1. PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING
 INFORMATION:
  
 TOTAL NUMBER OF PARKING SPACES
 NUMBER OF ACCESSIBLE SPACES ? PER TABLE 208.2
 LOCATION OF ACCESSIBLE ENTRANCES
 LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES
 SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY
 ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE
 ENTRANCE
  
 SEE FBC 2010 ACCESSIBILITY 202.3 (ALTERATIONS), 208.2
 (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE
 ROUTE).
  
 YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL,
 PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS
 RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE
 PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR
 ACCESSIBLE DESIGN."
  
 HTTP://WWW.ADA.GOV/RESTRIPE.HTM
  
 2. FBC 2010 ACCESSIBILITY ADVISORY 502.3, WHERE THE
 ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES,
 MARKED CROSSINGS ENHANCE PEDESTRIAN SAFETY; PLEASE
 INDICATE LOCATION ON PLAN.
  
 3. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE
 THEIR PRINTED NAME AND SIGNATURE ON THE PLAN, FBC 107.
  
 4. FBC 2010 ACCESSIBILITY 208.2.1, THE FOLLOWING USES
 HAVE ADDITIONAL PARKING REQUIREMENTS:
  
 HOSPITAL OUTPATIENT FACILITES
 REHABILITATION FACILITIES
 OUTPATIENT PHYSICAL THERAPY FACILITIES
  
 PLAN IS TO EITHER SHOW LOCATION OF TENANTS WITH ANY OF
 THE ABOVE USES OR PLAN IS TO INCLUDE A STATEMENT WHICH
 STATES THAT NONE OF THE ABOVE USES (HOSPITAL OUTPATIENT
 FACILITIES, REHABILITATION FACILITIES, OUTPATIENT
 PHYSICAL THERAPY FACILITIES) ARE AT THIS LOCATION.
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2016-03-28 Cont ID  
Sent By Mgonzale Date 2016-03-28 Time   Rev Time 1.00
Received By mgonzale Date 2016-03-28 Time   Sent To B
Notes
2016-06-22 10:08:19NO OBJECTIONS.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-04-05 Cont ID  
Sent By cthroop Date 2016-04-05 Time 13:24 Rev Time 0.00
Received By cthroop Date 2016-02-25 Time 13:47 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-03-01 Cont ID  
Sent By cthroop Date 2016-04-05 Time 13:24 Rev Time 0.00
Received By ajones Date 2016-03-01 Time 17:41 Sent To ENG
Notes
2016-03-01 17:43:363/1/16- FAILED NEED A SITE PLAN OR SURVEY SHOWING THE
 LAYOUT OF THE PARKING LOT.
 ANGELLA VANN, PLANNING AND ZONING ADMINISTRATOR
 [email protected]
 561-822-1441


Account Summary | Usage Policy | Privacy Policy