Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-04-05 Cont ID  
Sent By skennedy Date 2016-04-05 Time 09:26 Rev Time 0.00
Received By skennedy Date 2016-04-05 Time 09:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-03-22 Cont ID  
Sent By skennedy Date 2016-03-22 Time 10:38 Rev Time 0.00
Received By skennedy Date 2016-03-22 Time 10:36 Sent To  
Notes
2016-03-22 10:43:251ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 THE TYPICAL COVER SHEET CS-1 IS MISSING FROM THE PLAN
 SUBMITTAL ALTHOUGH IT IS IN THE SUPPORTING DOCUMENTS
 PORTION FOR PURPOSES OF DEMONSTRATING IMPACT FEE
 PAYMENT. PLEASE UPLOAD THIS SHEET AT TIME OF
 RE-SUBMITTAL.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-03-29 Cont ID  
Sent By vperez Date 2016-03-29 Time 10:01 Rev Time 0.00
Received By vperez Date 2016-03-29 Time 09:53 Sent To  
Notes
2016-03-29 10:02:132ND ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA RES BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011
 COMMENTS:
  
 1. PROVISO- SHOW ON AS-BUILT FINAL AN EQUIPMENT
 GROUNDING CONDUCTOR ROUTED WITH THE FEEDER, CORRELATE
 CHANGES WITH NOTES AT THE ONE-LINE DIAGRAM.. NEC
 250.122
 2. FEEL FREE TO CONTACT ME AT THE NUMBER LISTED BELOW
 SHOULD YOU HAVE ANY QUESTIONS OR CONCERNS.
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-03-18 Cont ID  
Sent By vperez Date 2016-03-18 Time 11:35 Rev Time 0.00
Received By vperez Date 2016-03-18 Time 10:05 Sent To  
Notes
2016-03-18 11:35:27INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA RES BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PLEASE PROVIDE AIC CALCULATIONS TO VERIFY EQUIPMENT
 RATINGS PER FBC RES E3606 AND FBC 107.3.5
 2. SHOW THE SERVICE MAIN PER FBC RES E3601.6.2. UNFUSED
 CONDUCTORS SHOWN THROUGH ATTIC NOT CONSIDERED NEAREST
 POINT OF ENTRY. MAIN TO BE READILY ACCESSIBLE NEAR THE
 POINT OF ENTRY. CORRELATE CHANGES WITH NOTES AT THE
 ONE-LINE DIAGRAM.
 3. PROVIDE GENERAL NOTES TO INDICATE FBC EC 404.1- 75%
 OF LAMPS TO HIGH EFFICACY LAMPS AND SEPARATE PERMITS
 REQUIRED FOR LOW VOLTAGE SYSTEMS.
 4. FEEL FREE TO CONTACT ME DIRECTLY SHOULD YOU HAVE ANY
 QUESTIONS OR CONCERNS.
  
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-04-06 Cont ID  
Sent By cpuell Date 2016-04-06 Time 14:07 Rev Time 0.00
Received By cpuell Date 2016-03-24 Time 11:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-03-24 Cont ID  
Sent By skennedy Date 2016-03-24 Time 09:41 Rev Time 0.00
Received By skennedy Date 2016-03-17 Time 15:22 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2016-03-22 Cont ID  
Sent By skennedy Date 2016-03-22 Time 10:03 Rev Time 0.00
Received By skennedy Date 2016-03-22 Time 10:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-03-22 Cont ID  
Sent By skennedy Date 2016-03-22 Time 10:15 Rev Time 0.00
Received By skennedy Date 2016-03-22 Time 10:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-03-22 Cont ID  
Sent By skennedy Date 2016-03-22 Time 10:33 Rev Time 0.00
Received By skennedy Date 2016-03-22 Time 10:33 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-03-22 Cont ID  
Sent By skennedy Date 2016-03-22 Time 10:03 Rev Time 0.00
Received By skennedy Date 2016-03-22 Time 10:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2016-04-07 Cont ID  
Sent By skennedy Date 2016-04-07 Time 09:56 Rev Time 0.00
Received By skennedy Date 2016-04-07 Time 09:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2016-03-22 Cont ID  
Sent By skennedy Date 2016-03-22 Time 10:10 Rev Time 0.00
Received By skennedy Date 2016-03-22 Time 10:04 Sent To  
Notes
2016-03-22 10:12:481ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 PROVIDE DIGITAL SIGNATURES OR ORIGINAL SIGNED AND
 SEALED VERSIONS FOR THE FOLLOWING DOCUMENTS:
  
 SOIL REPORT, SURVEY, AND TRUSS SUBMITTAL WHEN YOU
 CHOOSE TO PROVIDE IT ANY TIME PRIOR TO TRUSS
 INSTALLATION.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2016-04-06 Cont ID  
Sent By jroach Date 2016-04-06 Time 13:37 Rev Time 0.00
Received By jroach Date 2016-04-06 Time 13:37 Sent To  
Notes
***NONE***