Plan Review Stops For Permit 16020902 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-07-12 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2016-07-12 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2016-07-12 |
Time |
16:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-05-05 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2016-05-05 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2016-05-05 |
Time |
17:32 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-03-08 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2016-03-08 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2016-03-08 |
Time |
14:11 |
Sent To |
|
|
Notes |
2016-03-08 14:42:44 | ****CORRECTIONS**** | | | | ART LANGE - BUILDING INSPECTOR | | 561-805-6667 [email protected] | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION | | | | 2821 PINEWOOD AVE. DAY CARE | | | | | | 1. PLEASE SHOW HOW THIS BUILDING COMPLIES WITH FBC 466 | | DAYCARE OCCUPANCIES. NO INFORMATION PROVIDED. | | | | 2. THE ROOM SHOWN AS CLASSROOM "A" WAS A GARAGE - | | STORAGE ROOM AT TIME OF INSPECTION. NO INFORMATION HAS | | BEEN PROVIDED FOR REVIEW. IS THIS AN AIRCONDITIONED | | SPACE? | | | | 3. JANITOR ROOM HAD A SHOWER AND UTILITY SINK AND A | | SINK SHOWN JUST OUTSIDE THIS ROOM. CONFIRM IF FIXTURES | | ARE STILL IN PLACE. IT APPEARS THAT ONLY A UTILITY SINK | | IS IN THE SCOPE OF WORK FOR THIS PERMIT. | | | | 4. FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | BUILDINGS. OCCUPANCY GROUP, CONSTRUCTION TYPE, OCCUPANT | | LOAD AND EGRESS REQUIREMENTS AND WALL RATINGS. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2016-04-08 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-03-02 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-04-08 |
Time |
10:49 |
Sent To |
|
|
Notes |
2016-04-08 10:50:34 | NOTES CLEARED WITH DOUG H AND THE OWNER, COMMENTS NOT | | APPLICABLE | 2016-03-02 09:46:35 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | COMMENTS: | | | | 1.PLEASE PROVIDE A PANEL LOAD SCHEDULE REFLECTING LOADS | | AND BRANCH CIRCUIT CLEARLY IDENTIFIED FOR NEW EM | | LIGHTING. FBC 107.3.5 | | 2.SHOW PER NEC 700.12F THAT UNIT EQUIPMENT IS SERVED | | FROM THE NORMAL LIGHTING IN THE AREA AND CONNECTED | | AHEAD OF ANY LOCAL SWITCH. | | 3.FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL FREE | | TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD YOU | | HAVE ANY QUESTIONS OR CONCERNS. | | | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-07-11 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2016-07-11 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2016-07-11 |
Time |
11:04 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-03-17 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2016-03-08 |
Time |
14:52 |
Rev Time |
|
Received By |
|
Date |
2016-03-08 |
Time |
|
Sent To |
|
|
Notes |
2016-02-29 13:34:48 | FIRE IS OK WITH THE LIFE SAFTEY PLAN AS SUBMITTED | | REQUEST ELECTRICAL TO VERIFY THAT ELECTRICAL WORK IS | | BEING DONE BY A LICENSED ELECTRICIAN. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-07-11 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2016-07-11 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2016-07-01 |
Time |
10:33 |
Sent To |
|
|
Notes |
2016-07-01 10:33:29 | ROUTED TO TIM LARGE'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-05-09 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-05-09 |
Time |
05:39 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-05-05 |
Time |
17:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-03-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-03-22 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-03-08 |
Time |
15:38 |
Sent To |
|
|
Notes |
2016-03-08 15:39:03 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-03-08 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2016-03-08 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2016-02-23 |
Time |
11:25 |
Sent To |
FIRE |
|
Notes |
2016-03-02 10:00:31 | B08 | 2016-03-02 09:47:29 | 3/2 TO CAROLINE |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-07-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-07-05 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-07-05 |
Time |
13:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-05-09 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-05-09 |
Time |
05:39 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-05-09 |
Time |
05:02 |
Sent To |
|
|
Notes |
2016-05-09 05:39:15 | 1) SHOW THE INSIDE CLEAR DIMENSIONS FOR THE TOILET ROOM | | AND SHOW THE REQUIRED FLOOR CLEARANCES FOR THE PLUMBING | | FIXTURES PER THE 2014 FBC-PLUMBING SEC.405.3.1. 2ND | | REQUEST. | | 3) SUBMIT A WATER RISER DIAGRAM FOR REVIEW. FBC | | 107.3.5.1.3. 2ND REQUEST. | | 4) SIZE ALL SECTIONS OF THE SANITARY SYSTEM ON BOTH | | RISERS #1 & 2. 2ND REQUEST. | | 5) THE ADDITION OF BATHROOM #5 CREATES A | | RECONFIGIURATION OF SPACE AND THEREFORE THIS IS | | CONSIDERED A LEVEL 2 ALTERATION, NOT A LEVEL 1. CORRECT | | THE PLAN.2014FEBC SEC.504. | | 6) THERE ARE TWO IDENTICAL FLOOR PLAN SHEETS. REMOVE | | THE OLD SHEET AND SUBMIT THE LATEST REVISION. ANY | | PREVIOUS APPROVALS FROM PLAN REVIEWS MUST RE-REVIEW THE | | NEW SHEET. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-03-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-03-05 |
Time |
06:33 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-05 |
Time |
06:11 |
Sent To |
|
|
Notes |
2016-03-05 06:33:04 | 1) PLACE THE OCCUPANCY TYPE OF THE BUILDING ON THE | | PLANS IN ACCORDANCE WITH CHAPT. 3 OF THE 2014 FBC. | | 2) THE NEW TOILET ROOM SHALL COMPLY WITH THE FL. | | ACCESSIBILITY CODE SEC.213.1, 213.2.SUBMIT THE INSIDE | | CLEAR DIMENSIONS FOR THE TOILET ROOM AND SHOW THE | | REQUIRED FLOOR CLEARANCES FOR THE PLUMBING FIXTURES PER | | THE 2014 FAC SECS.305, 604, 606.2. | | 3) SUBMIT A WATER RISER DIAGRAM FOR REVIEW. FBC | | 107.3.5.1.3. | | 4) SIZE ALL SECTIONS OF THE SANITARY SYSTEM ON BOTH | | RISERS #1 3 2. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-07-08 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2016-07-08 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2016-07-08 |
Time |
13:55 |
Sent To |
FIRE |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-03-16 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-03-16 |
Time |
11:43 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2016-03-08 |
Time |
17:24 |
Sent To |
|
|
Notes |
2016-03-16 11:44:29 | VALUE DOES NOT EXCEED 50% OF BUILDING - INETERIOR WORK | | ONLY ON THIS PERMIT. |
|
|