Plan Review Details - Permit 16020902
Plan Review Stops For Permit 16020902
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-07-12 Cont ID  
Sent By aclange Date 2016-07-12 Time 16:22 Rev Time 0.00
Received By aclange Date 2016-07-12 Time 16:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-05-05 Cont ID  
Sent By aclange Date 2016-05-05 Time 17:32 Rev Time 0.00
Received By aclange Date 2016-05-05 Time 17:32 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-03-08 Cont ID  
Sent By aclange Date 2016-03-08 Time 14:12 Rev Time 0.00
Received By aclange Date 2016-03-08 Time 14:11 Sent To  
Notes
2016-03-08 14:42:44****CORRECTIONS****
  
 ART LANGE - BUILDING INSPECTOR
 561-805-6667 [email protected]
 FBC FLORIDA BUILDING CODE 2014 5TH EDITION
  
 2821 PINEWOOD AVE. DAY CARE
  
  
 1. PLEASE SHOW HOW THIS BUILDING COMPLIES WITH FBC 466
 DAYCARE OCCUPANCIES. NO INFORMATION PROVIDED.
  
 2. THE ROOM SHOWN AS CLASSROOM "A" WAS A GARAGE -
 STORAGE ROOM AT TIME OF INSPECTION. NO INFORMATION HAS
 BEEN PROVIDED FOR REVIEW. IS THIS AN AIRCONDITIONED
 SPACE?
  
 3. JANITOR ROOM HAD A SHOWER AND UTILITY SINK AND A
 SINK SHOWN JUST OUTSIDE THIS ROOM. CONFIRM IF FIXTURES
 ARE STILL IN PLACE. IT APPEARS THAT ONLY A UTILITY SINK
 IS IN THE SCOPE OF WORK FOR THIS PERMIT.
  
 4. FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR
 BUILDINGS. OCCUPANCY GROUP, CONSTRUCTION TYPE, OCCUPANT
 LOAD AND EGRESS REQUIREMENTS AND WALL RATINGS.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-04-08 Cont ID  
Sent By vperez Date 2016-03-02 Time 09:45 Rev Time 0.00
Received By vperez Date 2016-04-08 Time 10:49 Sent To  
Notes
2016-04-08 10:50:34NOTES CLEARED WITH DOUG H AND THE OWNER, COMMENTS NOT
 APPLICABLE
2016-03-02 09:46:35INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1.PLEASE PROVIDE A PANEL LOAD SCHEDULE REFLECTING LOADS
 AND BRANCH CIRCUIT CLEARLY IDENTIFIED FOR NEW EM
 LIGHTING. FBC 107.3.5
 2.SHOW PER NEC 700.12F THAT UNIT EQUIPMENT IS SERVED
 FROM THE NORMAL LIGHTING IN THE AREA AND CONNECTED
 AHEAD OF ANY LOCAL SWITCH.
 3.FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL FREE
 TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD YOU
 HAVE ANY QUESTIONS OR CONCERNS.
  
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-07-11 Cont ID  
Sent By scaldero Date 2016-07-11 Time 11:05 Rev Time 0.00
Received By scaldero Date 2016-07-11 Time 11:04 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-03-17 Cont ID  
Sent By aclange Date 2016-03-08 Time 14:52 Rev Time  
Received By   Date 2016-03-08 Time   Sent To  
Notes
2016-02-29 13:34:48FIRE IS OK WITH THE LIFE SAFTEY PLAN AS SUBMITTED
 REQUEST ELECTRICAL TO VERIFY THAT ELECTRICAL WORK IS
 BEING DONE BY A LICENSED ELECTRICIAN.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-07-11 Cont ID  
Sent By scaldero Date 2016-07-11 Time 11:07 Rev Time 0.00
Received By scaldero Date 2016-07-01 Time 10:33 Sent To  
Notes
2016-07-01 10:33:29ROUTED TO TIM LARGE'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-05-09 Cont ID  
Sent By tklarge Date 2016-05-09 Time 05:39 Rev Time 0.00
Received By tklarge Date 2016-05-05 Time 17:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-22 Cont ID  
Sent By lmarchan Date 2016-03-22 Time 13:44 Rev Time 0.00
Received By lmarchan Date 2016-03-08 Time 15:38 Sent To  
Notes
2016-03-08 15:39:03ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-03-08 Cont ID  
Sent By aclange Date 2016-03-08 Time 14:52 Rev Time 0.00
Received By aclange Date 2016-02-23 Time 11:25 Sent To FIRE
Notes
2016-03-02 10:00:31B08
2016-03-02 09:47:293/2 TO CAROLINE

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-07-05 Cont ID  
Sent By tklarge Date 2016-07-05 Time 13:40 Rev Time 0.00
Received By tklarge Date 2016-07-05 Time 13:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-05-09 Cont ID  
Sent By tklarge Date 2016-05-09 Time 05:39 Rev Time 0.00
Received By tklarge Date 2016-05-09 Time 05:02 Sent To  
Notes
2016-05-09 05:39:151) SHOW THE INSIDE CLEAR DIMENSIONS FOR THE TOILET ROOM
 AND SHOW THE REQUIRED FLOOR CLEARANCES FOR THE PLUMBING
 FIXTURES PER THE 2014 FBC-PLUMBING SEC.405.3.1. 2ND
 REQUEST.
 3) SUBMIT A WATER RISER DIAGRAM FOR REVIEW. FBC
 107.3.5.1.3. 2ND REQUEST.
 4) SIZE ALL SECTIONS OF THE SANITARY SYSTEM ON BOTH
 RISERS #1 & 2. 2ND REQUEST.
 5) THE ADDITION OF BATHROOM #5 CREATES A
 RECONFIGIURATION OF SPACE AND THEREFORE THIS IS
 CONSIDERED A LEVEL 2 ALTERATION, NOT A LEVEL 1. CORRECT
 THE PLAN.2014FEBC SEC.504.
 6) THERE ARE TWO IDENTICAL FLOOR PLAN SHEETS. REMOVE
 THE OLD SHEET AND SUBMIT THE LATEST REVISION. ANY
 PREVIOUS APPROVALS FROM PLAN REVIEWS MUST RE-REVIEW THE
 NEW SHEET.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-03-05 Cont ID  
Sent By tklarge Date 2016-03-05 Time 06:33 Rev Time 0.00
Received By tklarge Date 2016-03-05 Time 06:11 Sent To  
Notes
2016-03-05 06:33:041) PLACE THE OCCUPANCY TYPE OF THE BUILDING ON THE
 PLANS IN ACCORDANCE WITH CHAPT. 3 OF THE 2014 FBC.
 2) THE NEW TOILET ROOM SHALL COMPLY WITH THE FL.
 ACCESSIBILITY CODE SEC.213.1, 213.2.SUBMIT THE INSIDE
 CLEAR DIMENSIONS FOR THE TOILET ROOM AND SHOW THE
 REQUIRED FLOOR CLEARANCES FOR THE PLUMBING FIXTURES PER
 THE 2014 FAC SECS.305, 604, 606.2.
 3) SUBMIT A WATER RISER DIAGRAM FOR REVIEW. FBC
 107.3.5.1.3.
 4) SIZE ALL SECTIONS OF THE SANITARY SYSTEM ON BOTH
 RISERS #1 3 2.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2016-07-08 Cont ID  
Sent By njwira Date 2016-07-08 Time 13:55 Rev Time 0.00
Received By njwira Date 2016-07-08 Time 13:55 Sent To FIRE
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-03-16 Cont ID  
Sent By eschneid Date 2016-03-16 Time 11:43 Rev Time 0.50
Received By eschneid Date 2016-03-08 Time 17:24 Sent To  
Notes
2016-03-16 11:44:29VALUE DOES NOT EXCEED 50% OF BUILDING - INETERIOR WORK
 ONLY ON THIS PERMIT.