Plan Review Details - Permit 16020261
Plan Review Stops For Permit 16020261 |
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-02-19 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-02-19 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-02-18 |
Time |
14:45 |
Sent To |
|
|
Notes |
2016-02-18 14:45:35 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-02-18 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-02-09 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-02-08 |
Time |
16:27 |
Sent To |
|
|
Notes |
2016-02-08 16:27:26 | PLUMB -$5000 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-02-19 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-02-19 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-02-19 |
Time |
05:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-02-09 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-02-09 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-02-09 |
Time |
11:57 |
Sent To |
|
|
Notes |
2016-02-09 12:18:24 | 1) SUBMIT A FLOOR PLAN SHOWING THE LOCATION OF ALL THE | | FIXTURES TO BE REPLACED. 2014 FBC SEC. 107.2.1.FBC | | 2) THE APPLICATION NOTES "INSTALL PLUMBING FOR LAUNDRY | | ROOM."THIS IS VAGUE. IS THIS AN EXISTING LAUNDRY ROOM | | OR IS A NEW LAUNDRY ROOM BEING CREATED? CLEARLY SHOW | | THE SCOPE OF WORK BEING DONE IN THE LAUNDRY ROOM ON THE | | PLAN.2014 FBC SEC. 107.2.1. | | 3) THE APPLICATION NOTES "INSTALL TANKLESS WATER | | HEATER." IS THERE AN EXISTING TANKLESS WATER HEATER | | BEING REPLACED OR IS THIS TANKLESS REPLACEING A TANK | | TYPE WATER HEATER? IF IT IS REPLACING A TANK TYPE, THEN | | A SEPARATE ELECTRICAL PERMIT IS REQUIRED. | | 4) IF ANY BATHTUBS ARE BEING REPLACED, WHAT TYPE OF | | REPAIR IS BEING DONE TO THE WALLS. INDICATE ON THE | | PLAN.2014 FBC SEC. 107.2.1. | | 5) I AM QUESTIONING THE VALUE OF THIS JOB. SUBMIT A | | SIGNED CONTRACT SHOWING THE VALUATION OF THIS WORK.2014 | | FBC SEC.109.3. | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | TANKLESS WATER HEATER. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
|