Plan Review Details - Permit 16010815
Plan Review Stops For Permit 16010815 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-02-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-02-09 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-02-03 |
Time |
10:56 |
Sent To |
FIRE |
|
Notes |
2016-02-03 10:57:37 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. FBC 5TH EDITION EXISTING BUILDING 1106, ADDITIONS TO | | EXISTING BUILDINGS TO COMPLY WITH THE REQUIREMENTS OF | | TEH FBC, ENERGY CONSERVATION. | | | | FBC 5TH EDITION ENERGY CONSERVATION R101.5, ENERGY | | CALCS REQUIRED. | | | | 2. THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING | | PROVISO - BEDROOM TO STAY OPEN TO THE ENCLOSED LOGGIA | | (EMERGENCY ESCAPE AND RESCUE OPENING CANNOT BE BLOCKED) | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-02-11 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-02-11 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-02-11 |
Time |
13:29 |
Sent To |
|
|
Notes |
2016-02-11 13:53:18 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | FLORIDA RES BUILDING CODE 2014 5TH EDITION | | NFPA 70- 2011 | | COMMENTS: | | | | 1. PLEASE PROVIDE AND SHOW ON DRAWING THE RECEPTACLE | | OUTLETS NOW REQUIRED FOR WALL SPACE DUE TO ENCLOSING | | AREA. COMPLY WITH FBC RES- SEC E39012.1 AND 2.2 | | 2. SHOW AND PROVIDE THE REQUIRED LIGHTING OUTLETS PER | | FBC RES- SEC E3903.2 AND .3. INTERIOR AND EGRESS | | LOCATIONS | | 3. PROVIDE A NOTE TO COMPLY WITH AFCI PROTECTION FOR | | BRANCH CIRCUITS AND TAMPER RESISTANT RECEPTACLE PER FBC | | RES- SEC E3902.12 AND E4002.14 | | 4. SEE FBC RES 314 SMOKE ALARM REQUIREMENTS PER | | ALTERATION. PROVIDE OR SHOW EXISTING SMOKE DETECTORS TO | | COMPLY. SEE EXCEPTION 314.4-3 FOR EASE OF COMPLIANCE. | | 5. FURTHER COMMENTS MAT FOLLOW UPON RESUBMITTAL. | | 6. ELECTRICAL PERMIT REQUIRED | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-02-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-02-11 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-02-11 |
Time |
11:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-02-12 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-02-12 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-02-11 |
Time |
13:53 |
Sent To |
|
|
Notes |
2016-02-11 17:28:21 | 2/11 TO CCOLE DESK | | | 2016-02-11 13:54:04 | SENT TO SAM 2/11 | 2016-02-11 12:27:34 | 2/11 TO VAPEREZ DESK | | | 2016-02-09 16:10:05 | 2/9 TO FIRE | | | | | 2016-02-03 10:15:18 | 2/3 ON SH DESK | | | 2016-01-27 09:16:21 | GIVEN TO SKENNEDY |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
P |
Date |
2016-02-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-02-03 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-02-03 |
Time |
10:15 |
Sent To |
|
|
Notes |
2016-02-03 10:16:11 | MU 2015-22259 | | RECEIPT #2015-0921-296 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-02-12 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-02-12 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-02-12 |
Time |
10:37 |
Sent To |
|
|
Notes |
2016-02-12 10:55:18 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT 316010815 | | 2/12/16 | | | | 1) THE PERMIT APPLICATION AND PLANS WERE FORWARDED TO | | ME FOR MECHANICAL REVIEW BECAUSE A NEW ADDITION AT THE | | REAR OF THE BUILDING HAS BEEN CONSTRUCTED. PLEASE REFER | | TO SECTION 202 DEFINITIONS FBC-14 ENERGY CONSERVATION: | | ADDITION. AN EXTENSION OR INCREASE IN THE CONDITIONED | | SPACE FLOOR AREA OR HEIGHT OF A BUILDING OR STRUCTURE. | | AS STATED IN SECTIION R101.4.3 A NEW RESIDENTIAL | | ADDITION SHALL CONFORM TO THE PROVISIONS OF THE ENERGY | | CODE AS THEY RELATE TO NEW CONSTRUCTION. IN ORDER TO | | SHOW COMPLIANCE AS REQUIRED THE PLANS MUST BE REVISED | | TO SHOW COMPONENTS OF THE ADDITION'S THERMAL ENVELOPE | | AND MEP SYSTEMS, AND DOCUMENTATION OF ENERGY EFFICIENCY | | COMPLIANCE USING EITHER THE PRESCRIPTIVE OR PERFORMANCE | | BASED METHOD SHALL BE SUBMITTED. PLEASE SEE TABLE | | R101.5.1 AND SUBMIT DUPLICATE COPIES OF FORM R402 OR | | FORM R405.. | | 2) ALTHOUGH A NEW AC SYSTEM IS NOT SHOWN ON THE PLANS, | | DUE TO THE INCREASE IN CONDTIIONED FLOOR AREA, PLEASE | | PROVIDE AC COOLING AND HEATING CALCULATIONS AS OUTLINED | | IN SECTION R403.6.1.1. THE CALCULATIONS MUST INDICATE | | THAT THE EXISTING SYSTEM IS CAPABLE OF SUPPORTING THE | | ADDED LOAD, OR THE INSTALLATION OF A LARGER CAPACITY OR | | SUPPLEMENTAL SYSTEM MAY BE REQUIRED. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
|