2016-02-05 09:50:58 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 16010805 |
| ADD: 1645 PALM BEACH LAKES SUITE # 1050 |
| CONT: CHANDLER CONSTRUCTION |
| TEL: 561-791-6934 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: FRI. FEB. 05/2016 |
| ACTION: DENIED |
| |
| 1) SHEET A-2 VERSES A-3. INDICATED ON SHEET A-2 IN THE |
| WALL LEGEND IS THE WALL TYPE FOR A 1-HOUR FIRE RATED |
| PARTITION. SHEET A-2 SHOWS VARIOUS NEW WALLS WITHIN THE |
| TENANT SPACE WITH A WALL DETAIL OF 1/A3 WHICH INDICATES |
| THIS TYPE OF WALL AS A 1-HOUR FIRE RATED PARTITION. THE |
| DESIGNER CAN DESIGN OVER AND ABOVE THE MINIMUM CODE, IF |
| THIS THE ENTENT THEN THE DOORS WITHIN THE RATED WALL |
| WILL ALSO NEED TO COMPLY WITH OPENING PROTECTIVES FOUND |
| UNDER 2014 FBC-B TABLE716.5. |
| |
| 2) THE COMBINED AREA OF SUITE 1050 IS NOW 6098 OR |
| 6098/100= 61 OCCUPANTS. THE FRONT ENTRY DOORS SWING, |
| SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE |
| SERVING A ROOM OR AREA CONTAINING AN OCCUPANT LOAD OF |
| 50 OR MORE PERSONS OR A GROUP H OCCUPANCY.2014 FBC-B |
| 1008.1.2. NEW WORK SHALL NOT CREATE A NONCONFORMITY. |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 3) SHEET A-3 THE BREAKROOM # 114 SHOWS A MICROWAVE ON A |
| SHELF APPROXIMATELY 5 FEET ABOVE FINISH FLOOR. PLEASE |
| REVIEW THE 2014 FBC-ACCESSIBILITY CODE FOR OPERABLE |
| PARTS: |
| 309.1 GENERAL. OPERABLE PARTS SHALL COMPLY WITH 309. |
| |
| 309.2 CLEAR FLOOR SPACE. |
| A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 305 SHALL |
| BE PROVIDED. |
| |
| 309.3 HEIGHT. |
| OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF |
| THE REACH RANGES SPECIFIED IN 308. |
| |
| 309.4 OPERATION. |
| OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND |
| SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING |
| OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE |
| PARTS SHALL BE 5 POUNDS (22.2 N) MAXIMUM. |
| |
| 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |