Plan Review Stops For Permit 16010797 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-03-14 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-03-14 |
Time |
06:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-02-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-02-05 |
Time |
06:46 |
Rev Time |
|
Received By |
jwitmer |
Date |
2016-02-05 |
Time |
06:01 |
Sent To |
|
|
Notes |
2016-02-05 06:45:41 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16010797 | | ADD: 701 NORTHPOINT PKY. SUITE 150 | | CONT: CHANDLIER | | TEL: 791-6934 | | E-MAIL: JOHN @BUILDERCCC.COM | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: FRI. FEB. 05/2016 | | ACTION: DENIED | | | | 1) SHEET A-2: | | | | 1A) THE OFFICE 104 (2) OFFICES 104) AND CONFERENCE ROOM | | # 107 BOTH SHOW A DETAIL 1/ A-3 WHICH IS A 1-HOUR FIRE | | RATED WALL. IN THE OFFICE DOORWAY A DOOR IDENTIIFED AS | | A B TYPE DOOR IS SHOWN. ONSHEET A-3 THE B TYPE DOORWAY | | IS SHOWN AS A SOLID CORE WOOD DOOR WITH A 3/8 INCH | | TEMPERED GLASS. PLEASE PROVIDE COMPLIANCE WITH SECTION | | TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS | | AND MARKINGS & TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE | | PROTECTION RATINGS. | | | | 1B) IN THE CONFERENCE ROOM THE DOOR IS IDENTIFIED AS A | | DOOR TYPE C BUT IS NOT SHOWN ON THE DOOR SCHEDULE FOUND | | ON SHEET A3. THE FLOOR PLANS DO APPEAR TO BE THE SAME | | CONFIGURATION AS THE OFFICE DOOR AND SIDELIGHT IN | | OFFICE 104. 107.2.1.3 ADDITIONAL INFORMATION IS | | REQUIRED. | | | | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-03-09 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-03-09 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-03-09 |
Time |
10:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-02-12 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-02-12 |
Time |
07:48 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-02-12 |
Time |
07:48 |
Sent To |
|
|
Notes |
2016-02-12 08:02:31 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | COMMENTS: | | | | 1. PLEASE UPDATE REFERENCE ON ELECTRICAL SPECS TO | | INDICATE NEW SECTIONS OF THE FLORIDA ENERGY | | CONSERVATION CODE 2014 5TH EDITION. SECTIONS HAVE BEEN | | MOVED OVER TO FBC EC 405.7 NOT SECTION 505 | | 2. PROVIDE A NOTE TO INDICATE THE CARD READERS AND | | DATA/PHONES TO BE ON SEPARATE PERMIT. A NOTE WILL | | SUFFICE. FBC 107. | | 3. PROVIDE A NOTE TO MAINTAIN FIRE RATING ON DEMISING | | WALLS. NEC 300.21 | | | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-03-07 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-03-07 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-03-07 |
Time |
15:43 |
Sent To |
|
|
Notes |
2016-03-07 15:51:18 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | 1. SHEET T - AN INCORRECT REFERENCE TO THE FIRE CODE | | WAS NOTED; HOWEVER, IT DOES NOT APPEAR TO HAVE AN | | IMPACT ON THE SUBMITTAL. FURTHER REVIEW MAY BE | | WARRANTED BY YOUR DESIGNERS OR CONTRACTORS. | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | APPLICABLE CODES OR STANDARDS. | | | | | | | | PLEASE UPDATE YOUR RECORDS FOR FUTURE SUBMISSIONS. | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2016-01-29 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-01-29 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-01-29 |
Time |
11:30 |
Sent To |
|
|
Notes |
2016-01-29 13:02:44 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1. SHEET A - 2, INDICATES TWO DOORS LABELED AS "C". THE | | DOOR SCHEDULE DOES NOT INDICATE A "C" DOOR DESCRIPTION. | | PLEASE CORRECT. | | | | 2. SHEET 3 - 1, INDICATES CARD READERS ON EXIT DOORS, | | PROVIDE NOTE INDICATING THAT THEY SHALL DELAY OR | | RESTRICT EGRESS. | | | | 3. SHEET 3 - 1, PROVIDE A NOTE INDICATING THAT FIRE | | ALARM WORK SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-03-14 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-03-03 |
Time |
12:46 |
Sent To |
|
|
Notes |
2016-03-09 10:19:16 | 3/9 TO B11 | 2016-03-03 12:46:49 | B11 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-02-12 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-02-12 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-02-12 |
Time |
08:02 |
Sent To |
|
|
Notes |
2016-02-12 08:03:15 | TO CAROLINE/LAURA | 2016-01-26 15:35:35 | B06 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-03-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-03-10 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-03-10 |
Time |
17:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-02-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-02-05 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-02-05 |
Time |
13:47 |
Sent To |
|
|
Notes |
2016-02-05 13:50:57 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT 16010797 | | 2/5/16 | | | | 1) PROVIDE EXHAUST DUCT RUN DETAILS FOR CF-1 INCLUDING | | TYPE AND SIZE OF DUCT, RUN LENGTH AND TERMINATION | | LOCATION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-01-31 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-01-31 |
Time |
03:38 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-01-31 |
Time |
03:14 |
Sent To |
|
|
Notes |
|
|