2016-01-22 17:00:18 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 16010668 |
| ADD: 2401 EMBASSY DR. |
| CONT: LEO ROOFING |
| TEL: 561-935-4979 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: FRI. JAN. 22/ 2016 |
| ACTION: DENIED |
| |
| 1) WIND EXPOSURE TO THE N. W. IS A EXPOSURE D NOT A B. |
| 2014 FBC-B 1609.4.3 EXPOSURE CATEGORY D. EXPOSURE D |
| SHALL APPLY WHERE THE GROUND SURFACE ROUGHNESS, AS |
| DEFINED BY SURFACE ROUGHNESS D, PREVAILS IN THE UPWIND |
| DIRECTION FOR A DISTANCE OF AT LEAST 5,000 FEET (1524 |
| M) OR 20 TIMES THE HEIGHT OF THE BUILDING, WHICHEVER IS |
| GREATER. EXPOSURE D SHALL ALSO APPLY WHERE THE GROUND |
| SURFACE ROUGHNESS IMMEDIATELY UPWIND OF THE SITE IS B |
| OR C, AND THE SITE IS WITHIN A DISTANCE OF 600 FEET |
| (183 M) OR 20 TIMES THE BUILDING HEIGHT, WHICHEVER IS |
| GREATER, FROM AN EXPOSURE D CONDITION AS DEFINED IN THE |
| PREVIOUS SENTENCE. |
| |
| 2) THE FL 7804-R8 ENTEGRA ROOF TILE REPORT PAGE 2 DID |
| NOT IDENTIFY WHICH FLAT TILE IS TO BE INSTALLED. TABLES |
| 1 & 2 WERE NOT CIRCLED AS TO AERODYNAMIC MULTIPLIERS, |
| RESTORING MOMENT, DIRECT DECK, ROOF SLOPE. TABLE 3A-2 |
| ALSO NOT FILED OUT. |
| |
| 3) THE FL 6332-R4 3M ROOF TILE ADHESIVE TABLE 1, TABLE |
| 2 AND PADDY PLACEMENT ON PAGE 5 OF 6 IS NOT IDENTIFIED. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |