Plan Review Stops For Permit 16010556 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-08-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-05 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-05 |
Time |
12:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-07-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-29 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-29 |
Time |
08:51 |
Sent To |
|
|
Notes |
2016-07-29 08:52:17 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | ACTION: DENIED | | DATE: 7/29/16 | | | | 1. PROFESSIONAL ENGINEER, JOHN HOLT HAS BEEN SUSPENDED | | BY THE DEPARTMENT OF BUSINESS AND PROFESSIONAL | | REGULATIONS FROM PRACTICING ENGINEERING IN THE STATE OF | | FLORIDA. OBTAIN ANOTHER DESIGN PROFESSIONAL AND | | RE-SUBMIT. | | 2. PROVIDE DESIGN WIND LOADS PER FBC CHPT. 16 AND ASCE | | 7-10. | | | | 1603.1.4 WIND DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | STRUCTURE: | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | 1609.3.1. | | 2. RISK CATEGORY. | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | THAN ONE WIND EXPOSURE IS UTILIZED. | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | M2). | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-02-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-02-19 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-02-19 |
Time |
15:30 |
Sent To |
E |
|
Notes |
2016-02-19 15:33:01 | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | PROVIDE DETAIL ON EXTERIOR WALL AT PROPOSED SIGN | | LOCATION. | | PROVIDE FASTENER SPECS. BASED ON WALL TYPE, | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-08-04 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-04 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-04 |
Time |
13:30 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-07-28 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-07-28 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-07-28 |
Time |
15:43 |
Sent To |
B |
|
Notes |
2016-07-28 15:54:44 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | -PROFFESIONAL ENGINEER JOHN HOLT LICENSE HAS BEEN | | SUSPENDED BY THE BOARD, HIS SIGNATURE IS NO LONGER | | VALID. NEW DESIGNER IS REQUIRED | | | | THESE COMMENTS WERE NOT ADDRESSED ( 2ND REQUEST ) | | | | 1) A 20 AMP DEDICATED BRANCH CIRCUIT IS REQUIRED PER | | NEC 600.5. IF EXISTING PLEASE MARK ON PLANS ! | | | | 2) ADD A NOTE FOR FBC-E SECTION C405.2.4 EXTERIOR | | LIGHTING CONTROLS. LIGHTING NOT DESIGNATED FOR | | DUSK-TO-DAWN OPERATION SHALL BE CONTROLLED BY EITHER A | | COMBINATION OF A PHOTOSENSOR AND A TIME SWITCH, OR AN | | ASTRONOMICAL TIME SWITCH. LIGHTING DESIGNATED FOR | | DUSK-TO-DAWN OPERATION SHALL BE CONTROLLED BY AN | | ASTRONOMICAL TIME SWITCH OR PHOTOSENSOR. | | ALL TIME SWITCHES SHALL BE CAPABLE OF RETAINING | | PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER | | FOR A PERIOD OF AT LEAST 10 HOURS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-02-22 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-02-22 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-02-22 |
Time |
11:23 |
Sent To |
|
|
Notes |
2016-02-22 11:25:20 | 1ST REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6713 | | [email protected] | | | | | | | | | | - NEC 600.5 A THE BRANCH CIRCUIT FOR A SIGN SHALL BE A | | DEDICATED 20 AMP CIRCUIT SERVING NO OTHER LOADS. | | - C405.2.4 EXTERIOR LIGHTING CONTROLS | | LIGHTING NOT DESIGNATED FOR DUSK-TO-DAWN OPERATION | | SHALL BE CONTROLLED BY EITHER A COMBINATION OF A | | PHOTOSENSOR AND A TIME SWITCH, OR AN ASTRONOMICAL TIME | | SWITCH. LIGHTING DESIGNATED FOR DUSK-TO-DAWN OPERATION | | SHALL BE CONTROLLED BY AN ASTRONOMICAL TIME SWITCH OR | | PHOTOSENSOR. ALL TIME SWITCHES SHALL BE CAPABLE OF | | RETAINING PROGRAMMING AND THE TIME SETTING DURING LOSS | | OF POWER FOR A PERIOD OF AT LEAST 10 HOURS.. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-08-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-05 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-02 |
Time |
12:55 |
Sent To |
|
|
Notes |
2016-08-02 12:55:34 | RESUB ROUTED TO KMARTIN VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-07-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-29 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-29 |
Time |
12:49 |
Sent To |
|
|
Notes |
2016-07-26 14:04:44 | THE APPLICANT HAS RESUBMITTED THE PERMIT DUE TO NEW | | ZONING REGULATIONS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-02-22 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-02-22 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-01-19 |
Time |
11:39 |
Sent To |
|
|
Notes |
2016-02-12 15:47:18 | MISC 2 BOX. | 2016-01-20 11:39:07 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2016-08-03 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-08-03 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-08-03 |
Time |
16:39 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-07-26 |
|
|
Cont ID |
|
Sent By |
kmartin |
Date |
2016-07-26 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-07-26 |
Time |
14:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-02-12 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-02-12 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-02-12 |
Time |
15:42 |
Sent To |
|
|
Notes |
2016-02-12 15:47:05 | 1. PROPOSED MERRYL LYNCH SIGN IS NOT PERMITTED. OTHER | | TWO PERMITS ARE CURRENTLY UNDER PROCESS FOR A "BANK OF | | AMERICA" IDENTITY SIGNS ON THE TOP OF THE TOWER | | BUILDING. ACCORDING TO RES 107-15 ONLY TWO IDENTITY | | SIGNS ARE ALLOWED FOR THE OFFICE BUILDINGS, AND BOTH | | SHALL HAVE THE SAME IDENTITY. APPLICANT CAN CHOOSE TO | | REMOVE THE BANK OF AMERICA AND INSTALL ONLY TWO MERYL | | LYNCH SIGNS. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|