Plan Review Stops For Permit 16010338 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
N |
Date |
2016-01-15 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2016-01-15 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2016-01-15 |
Time |
08:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-03-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-03-16 |
Time |
17:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-03-15 |
Time |
17:16 |
Sent To |
|
|
Notes |
2016-03-16 18:01:25 | APPROVED WITH EXCEPTION | | | | THE COMPONENT AND CLADDING PRESSURES SPECIFIED ON THE | | PLANS FOR THE 16' X 8' GARAGE DOOR ARE HIGHER THAN THE | | DESIGN PRESSURES IN THE NOA FOR THE GARAGE DOOR. THE | | PRESSURES ON THE PLAN APPEAR TO BE TOO HIGH FOR A | | SECTIONAL GARAGE DOOR. REVISE THE PRESSURES ON PLAN | | SHEET A-3 OR SUBMIT PRODUCT APPROVALS WITH GREATER | | DESIGN PRESSURES. FBC-R301.2.1 | | | | THE PRE-REMODEL ELEVATION CERTIFICATE THAT WAS | | SUBMITTED DATED 3/1/16 IS ON THE OLD FORM AND IS | | EXPIRED. THE NEW FORMS WHICH EXPIRE ON 11/30/2018 | | BECAME EFFECTIVE ON 1/9/2016. SUBMIT ELEVATION | | CERTIFICATES USING THE NEW FORMS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-02-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-02-12 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-02-10 |
Time |
16:02 |
Sent To |
|
|
Notes |
2016-02-11 11:09:24 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD | | AREA. THE PROPOSED WORK IS AN ADDITION AND SUBSTANTIAL | | IMPROVEMENT TO THE EXISTING STRUCTURE. THE CITY OF WEST | | PALM BEACH'S FLOOD ORDINANCE, FEMA AND THE 2014 FLORIDA | | BUILDING CODE RESIDENTIAL REQUIRE THE STRUCTURE TO | | COMPLY WITH THE FLOOD ORDINANCE. THE MINIMUM FINISH | | FLOOR ELEVATION IS REQUIRED TO BE 7.5' NGVD 1929. | | SPECIFY THE FINISH FLOOR ELEVATIONS ON THE PLANS BASED | | ON NGVD 1929 AND SUBMIT A PRECONSTRUCTION ELEVATION | | CERTIFICATE. | | | | 2) A SEPARATE PERMIT, APPLICATION AND PLANS ARE | | REQUIRED FOR THE ELECTRIC GENERATOR. FBC 105.1 | | | | 3) THE COMPONENT AND CLADDING PRESSURES ON SHEETS A-3 | | ARE INCORRECT FOR THE SECTIONAL GARAGE DOOR AND FRENCH | | DOORS ON THE PROPOSED WEST ELEVATION. BASED ON FBCR | | TABLES R301.2(2), R301.2(3) AND R301.2(4) THE SPECIFIED | | PRESSURES ARE LOWER THAN REQUIRED. | | | | 4) THE DOOR SCHEDULE ON A-7 SPECIFIES A GLASS PANEL ON | | TOP OF THE ENTRY DOOR, BUT NOT SIDELITES ON EACH SIDE | | AS SHOWN ON THE FLOOR PLAN AND ELEVATIONS ON SHEETS A-1 | | AND A-3. PLEASE CLARIFY. SPECIFY THE SIZES OF THE | | SIDELITES AND THE TRANSOM ON THE PLANS. FBC 107.2.1 | | | | 5) ON SHEET S-2 ROOF FRAMING NOTE #6 REFERENCES THE | | 2010 FBC AND THE 2014 FBC SHOULD BE REFERENCED. | | | | 6) ON SHEET E-1 THE GENERAL ELECTRICAL NOTES REFERENCES | | THE 2008 NEC AND THE 2011 NEC SHOULD BE REFERENCED. | | | | 7) THE WINDOW SCHEDULE ON SHEET A-7 SPECIFIES DOUBLE | | HUNG WINDOWS AND THE PRODUCT APPROVALS THAT WERE | | SUBMITTED ARE FOR SINGLE HUNG WINDOWS. PLEASE CLARIFY. | | FBC 107.2.1 | | | | 8) THE PLANS SPECIFY DOUBLE OUTSWING WOOD FRENCH DOORS | | WITH AND WITHOUT SIDELITES. THE PRODUCT APPROVALS THAT | | WERE SUBMITTED ARE FOR SINGLE OUTSWING ALUMINUM FRENCH | | DOORS W/WO SIDELITES. SUBMIT PRODUCT APPROVALS FOR THE | | DOORS THAT WILL BE USED. FBC 107.2.1 & DCA RULE 9N-72 | | | | 9) SUBMIT TWO SETS OF THE CURRENT ICC-ES EVALUATION | | REPORTS FOR THE SPRAY FOAM INSULATION THAT WILL BE | | INSTALLED. FBC-R316 | | | | 10) SUBMIT TWO SETS OF MANUFACTURER'S SPECIFICATIONS, | | LISTING AND INSTALLATION INSTRUCTIONS FOR THE FACTORY | | BUILT GAS FIREPLACE AND CHIMNEY. FBC-R1005 | | | | 11) PROVIDE STRUCTURAL DETAILS FOR THE FIREPLACE AND | | CHIMNEY. FBC 107.2.1 | | | | 12) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-03-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-03-16 |
Time |
07:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-03-15 |
Time |
18:38 |
Sent To |
|
|
Notes |
2016-03-16 07:39:21 | APPROVED WITH EXCEPTIONS. REDLINED CORRECTIONS ON THE | | PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2016-02-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-02-16 |
Time |
18:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-02-16 |
Time |
13:43 |
Sent To |
|
|
Notes |
2016-02-16 13:43:59 | APPROVED WITH EXCEPTIONS. REDLINED CORRECTIONS ON THE | | PLANS. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2016-01-28 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-01-28 |
Time |
05:02 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-01-28 |
Time |
05:02 |
Sent To |
|
|
Notes |
2016-01-28 05:02:29 | GAS PLAN REVIEW | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | 107.2.1. | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2016-04-27 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-04-27 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-04-27 |
Time |
11:12 |
Sent To |
|
|
Notes |
2016-04-27 11:13:15 | APPROVED PER CITY COMMISSION APPEAL. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2016-03-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-03-18 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-03-18 |
Time |
15:11 |
Sent To |
|
|
Notes |
2016-03-18 15:12:00 | REQUIRES HPB APPROVAL, SCHEDULED FOR 3/29/16. FHM |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2016-01-27 |
|
|
Cont ID |
|
Sent By |
fmttner |
Date |
2016-01-27 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-01-27 |
Time |
15:53 |
Sent To |
|
|
Notes |
2016-01-27 15:54:41 | WAITING ON COA SUBMITTAL. FHM HAS BEEN IN CONTACT WITH | | ARCHITECT. QUESTIONS CONTACT FRIEDERIKE MITTNER AT | | 822-1457 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-03-26 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-03-26 |
Time |
03:52 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-07 |
Time |
10:33 |
Sent To |
|
|
Notes |
2016-03-18 15:47:42 | 3/18 - ROUTED TO TKLARGE | 2016-03-08 10:33:37 | R20 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-02-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-02-16 |
Time |
18:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-01-15 |
Time |
15:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2016-03-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-03-15 |
Time |
18:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-03-15 |
Time |
18:38 |
Sent To |
|
|
Notes |
2016-03-15 18:40:06 | MU-2016-5281, NO IMPACT FEES WERE DUE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-02-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-02-10 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-02-10 |
Time |
17:54 |
Sent To |
|
|
Notes |
2016-02-10 17:55:05 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2016-02-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-02-12 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-02-12 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-03-26 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-03-26 |
Time |
03:52 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-26 |
Time |
03:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-01-28 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-01-28 |
Time |
05:01 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-01-28 |
Time |
04:33 |
Sent To |
|
|
Notes |
2016-01-28 05:01:01 | 1) THE LAVATORIES IN THE MASTER BATH ARE NOT VENTED. | | 2014 FBCR SEC.P3101.2. | | 2) A VENT IS REQD. BETWEEN THE TUB & SHOWER IN THE | | MASTER BATH. 2014 FBCR SEC.P3101.2. | | 3) BATH #2 - A VENT IS REQUIRED BETWEEN THE WATER | | CLOSET AND THE SHOWER. 2014 FBCR SEC.P3101.2. | | 4) BATH #3 - A VENT IS REQUIRED BETWEEN THE WATER | | CLOSET AND THE SHOWER. 2014 FBCR SEC.P3101.2. | | 5) A VENT IS REQUIRED ON THE WASHING MACHINE. 2014 FBCR | | SEC.P3101.2. | | 6) THE WASHING MACHINE AND LAVATORY CANNOT DISCHARGE | | INTO THE WASTE STACK AT THE SAME LEVEL PER 2014 FBCR | | SEC.P3005.1.1. | | 7) CLEANOUTS ARE REQUIRED IN THE BASE OF SOIL % WASTE | | STACKS PER 2014 FBCR SEC. P3005.2.6. | | 8) SEPARATE PLANS AND PERMIT ARE REQUIRED FOR THE GAS | | PIPING INSTALLATION. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2016-03-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-03-16 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-03-16 |
Time |
07:40 |
Sent To |
|
|
Notes |
2016-03-16 08:02:59 | ROOFING MATERIALS. | | 1) BORAL TILE SEAL NOA NO.131113.05 | | 2) ENTEGRA ROOF TILE( PLANTATION ROOF TILE) NOA NO. | | 15-0721.04 | | 3) 3M (AH-160 ROOF TILE ADHESIVE) NOA NO.14-0805.01 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-03-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-03-18 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-03-18 |
Time |
15:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-01-27 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-01-27 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-01-27 |
Time |
15:55 |
Sent To |
|
|
Notes |
|
|