Plan Review Details - Permit 16010338
Plan Review Stops For Permit 16010338
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2016-01-15 Cont ID  
Sent By spalmer Date 2016-01-15 Time 08:36 Rev Time 0.00
Received By spalmer Date 2016-01-15 Time 08:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-03-16 Cont ID  
Sent By rmcdouga Date 2016-03-16 Time 17:49 Rev Time 0.00
Received By rmcdouga Date 2016-03-15 Time 17:16 Sent To  
Notes
2016-03-16 18:01:25APPROVED WITH EXCEPTION
  
 THE COMPONENT AND CLADDING PRESSURES SPECIFIED ON THE
 PLANS FOR THE 16' X 8' GARAGE DOOR ARE HIGHER THAN THE
 DESIGN PRESSURES IN THE NOA FOR THE GARAGE DOOR. THE
 PRESSURES ON THE PLAN APPEAR TO BE TOO HIGH FOR A
 SECTIONAL GARAGE DOOR. REVISE THE PRESSURES ON PLAN
 SHEET A-3 OR SUBMIT PRODUCT APPROVALS WITH GREATER
 DESIGN PRESSURES. FBC-R301.2.1
  
 THE PRE-REMODEL ELEVATION CERTIFICATE THAT WAS
 SUBMITTED DATED 3/1/16 IS ON THE OLD FORM AND IS
 EXPIRED. THE NEW FORMS WHICH EXPIRE ON 11/30/2018
 BECAME EFFECTIVE ON 1/9/2016. SUBMIT ELEVATION
 CERTIFICATES USING THE NEW FORMS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-02-12 Cont ID  
Sent By rmcdouga Date 2016-02-12 Time 09:50 Rev Time 0.00
Received By rmcdouga Date 2016-02-10 Time 16:02 Sent To  
Notes
2016-02-11 11:09:24PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA. THE PROPOSED WORK IS AN ADDITION AND SUBSTANTIAL
 IMPROVEMENT TO THE EXISTING STRUCTURE. THE CITY OF WEST
 PALM BEACH'S FLOOD ORDINANCE, FEMA AND THE 2014 FLORIDA
 BUILDING CODE RESIDENTIAL REQUIRE THE STRUCTURE TO
 COMPLY WITH THE FLOOD ORDINANCE. THE MINIMUM FINISH
 FLOOR ELEVATION IS REQUIRED TO BE 7.5' NGVD 1929.
 SPECIFY THE FINISH FLOOR ELEVATIONS ON THE PLANS BASED
 ON NGVD 1929 AND SUBMIT A PRECONSTRUCTION ELEVATION
 CERTIFICATE.
  
 2) A SEPARATE PERMIT, APPLICATION AND PLANS ARE
 REQUIRED FOR THE ELECTRIC GENERATOR. FBC 105.1
  
 3) THE COMPONENT AND CLADDING PRESSURES ON SHEETS A-3
 ARE INCORRECT FOR THE SECTIONAL GARAGE DOOR AND FRENCH
 DOORS ON THE PROPOSED WEST ELEVATION. BASED ON FBCR
 TABLES R301.2(2), R301.2(3) AND R301.2(4) THE SPECIFIED
 PRESSURES ARE LOWER THAN REQUIRED.
  
 4) THE DOOR SCHEDULE ON A-7 SPECIFIES A GLASS PANEL ON
 TOP OF THE ENTRY DOOR, BUT NOT SIDELITES ON EACH SIDE
 AS SHOWN ON THE FLOOR PLAN AND ELEVATIONS ON SHEETS A-1
 AND A-3. PLEASE CLARIFY. SPECIFY THE SIZES OF THE
 SIDELITES AND THE TRANSOM ON THE PLANS. FBC 107.2.1
  
 5) ON SHEET S-2 ROOF FRAMING NOTE #6 REFERENCES THE
 2010 FBC AND THE 2014 FBC SHOULD BE REFERENCED.
  
 6) ON SHEET E-1 THE GENERAL ELECTRICAL NOTES REFERENCES
 THE 2008 NEC AND THE 2011 NEC SHOULD BE REFERENCED.
  
 7) THE WINDOW SCHEDULE ON SHEET A-7 SPECIFIES DOUBLE
 HUNG WINDOWS AND THE PRODUCT APPROVALS THAT WERE
 SUBMITTED ARE FOR SINGLE HUNG WINDOWS. PLEASE CLARIFY.
 FBC 107.2.1
  
 8) THE PLANS SPECIFY DOUBLE OUTSWING WOOD FRENCH DOORS
 WITH AND WITHOUT SIDELITES. THE PRODUCT APPROVALS THAT
 WERE SUBMITTED ARE FOR SINGLE OUTSWING ALUMINUM FRENCH
 DOORS W/WO SIDELITES. SUBMIT PRODUCT APPROVALS FOR THE
 DOORS THAT WILL BE USED. FBC 107.2.1 & DCA RULE 9N-72
  
 9) SUBMIT TWO SETS OF THE CURRENT ICC-ES EVALUATION
 REPORTS FOR THE SPRAY FOAM INSULATION THAT WILL BE
 INSTALLED. FBC-R316
  
 10) SUBMIT TWO SETS OF MANUFACTURER'S SPECIFICATIONS,
 LISTING AND INSTALLATION INSTRUCTIONS FOR THE FACTORY
 BUILT GAS FIREPLACE AND CHIMNEY. FBC-R1005
  
 11) PROVIDE STRUCTURAL DETAILS FOR THE FIREPLACE AND
 CHIMNEY. FBC 107.2.1
  
 12) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT
 A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-03-16 Cont ID  
Sent By rmcdouga Date 2016-03-16 Time 07:39 Rev Time 0.00
Received By rmcdouga Date 2016-03-15 Time 18:38 Sent To  
Notes
2016-03-16 07:39:21APPROVED WITH EXCEPTIONS. REDLINED CORRECTIONS ON THE
 PLANS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-02-16 Cont ID  
Sent By rmcdouga Date 2016-02-16 Time 18:07 Rev Time 0.00
Received By rmcdouga Date 2016-02-16 Time 13:43 Sent To  
Notes
2016-02-16 13:43:59APPROVED WITH EXCEPTIONS. REDLINED CORRECTIONS ON THE
 PLANS.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2016-01-28 Cont ID  
Sent By tklarge Date 2016-01-28 Time 05:02 Rev Time 0.00
Received By tklarge Date 2016-01-28 Time 05:02 Sent To  
Notes
2016-01-28 05:02:29GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2016-04-27 Cont ID  
Sent By fmittner Date 2016-04-27 Time 11:12 Rev Time 0.00
Received By fmittner Date 2016-04-27 Time 11:12 Sent To  
Notes
2016-04-27 11:13:15APPROVED PER CITY COMMISSION APPEAL.

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2016-03-18 Cont ID  
Sent By fmittner Date 2016-03-18 Time 15:11 Rev Time 0.00
Received By fmittner Date 2016-03-18 Time 15:11 Sent To  
Notes
2016-03-18 15:12:00REQUIRES HPB APPROVAL, SCHEDULED FOR 3/29/16. FHM

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2016-01-27 Cont ID  
Sent By fmttner Date 2016-01-27 Time 15:53 Rev Time 0.00
Received By fmittner Date 2016-01-27 Time 15:53 Sent To  
Notes
2016-01-27 15:54:41WAITING ON COA SUBMITTAL. FHM HAS BEEN IN CONTACT WITH
 ARCHITECT. QUESTIONS CONTACT FRIEDERIKE MITTNER AT
 822-1457

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-26 Cont ID  
Sent By tklarge Date 2016-03-26 Time 03:52 Rev Time 0.00
Received By tklarge Date 2016-03-07 Time 10:33 Sent To  
Notes
2016-03-18 15:47:423/18 - ROUTED TO TKLARGE
2016-03-08 10:33:37R20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-02-16 Cont ID  
Sent By rmcdouga Date 2016-02-16 Time 18:09 Rev Time 0.00
Received By rmcdouga Date 2016-01-15 Time 15:59 Sent To  
Notes
2016-01-19 16:00:19R30

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-03-15 Cont ID  
Sent By rmcdouga Date 2016-03-15 Time 18:38 Rev Time 0.00
Received By rmcdouga Date 2016-03-15 Time 18:38 Sent To  
Notes
2016-03-15 18:40:06MU-2016-5281, NO IMPACT FEES WERE DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-02-10 Cont ID  
Sent By rmcdouga Date 2016-02-10 Time 17:54 Rev Time 0.00
Received By rmcdouga Date 2016-02-10 Time 17:54 Sent To  
Notes
2016-02-10 17:55:05BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-02-12 Cont ID  
Sent By rmcdouga Date 2016-02-12 Time 10:36 Rev Time 0.00
Received By rmcdouga Date 2016-02-12 Time 10:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-03-26 Cont ID  
Sent By tklarge Date 2016-03-26 Time 03:52 Rev Time 0.00
Received By tklarge Date 2016-03-26 Time 03:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-01-28 Cont ID  
Sent By tklarge Date 2016-01-28 Time 05:01 Rev Time 0.00
Received By tklarge Date 2016-01-28 Time 04:33 Sent To  
Notes
2016-01-28 05:01:011) THE LAVATORIES IN THE MASTER BATH ARE NOT VENTED.
 2014 FBCR SEC.P3101.2.
 2) A VENT IS REQD. BETWEEN THE TUB & SHOWER IN THE
 MASTER BATH. 2014 FBCR SEC.P3101.2.
 3) BATH #2 - A VENT IS REQUIRED BETWEEN THE WATER
 CLOSET AND THE SHOWER. 2014 FBCR SEC.P3101.2.
 4) BATH #3 - A VENT IS REQUIRED BETWEEN THE WATER
 CLOSET AND THE SHOWER. 2014 FBCR SEC.P3101.2.
 5) A VENT IS REQUIRED ON THE WASHING MACHINE. 2014 FBCR
 SEC.P3101.2.
 6) THE WASHING MACHINE AND LAVATORY CANNOT DISCHARGE
 INTO THE WASTE STACK AT THE SAME LEVEL PER 2014 FBCR
 SEC.P3005.1.1.
 7) CLEANOUTS ARE REQUIRED IN THE BASE OF SOIL % WASTE
 STACKS PER 2014 FBCR SEC. P3005.2.6.
 8) SEPARATE PLANS AND PERMIT ARE REQUIRED FOR THE GAS
 PIPING INSTALLATION.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-03-16 Cont ID  
Sent By rmcdouga Date 2016-03-16 Time 07:40 Rev Time 0.00
Received By rmcdouga Date 2016-03-16 Time 07:40 Sent To  
Notes
2016-03-16 08:02:59ROOFING MATERIALS.
 1) BORAL TILE SEAL NOA NO.131113.05
 2) ENTEGRA ROOF TILE( PLANTATION ROOF TILE) NOA NO.
 15-0721.04
 3) 3M (AH-160 ROOF TILE ADHESIVE) NOA NO.14-0805.01
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2016-03-18 Cont ID  
Sent By fmittner Date 2016-03-18 Time 15:12 Rev Time 0.00
Received By fmittner Date 2016-03-18 Time 15:12 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-01-27 Cont ID  
Sent By fmittner Date 2016-01-27 Time 15:55 Rev Time 0.00
Received By fmittner Date 2016-01-27 Time 15:55 Sent To  
Notes
***NONE***