Plan Review Details - Permit 16010035
Plan Review Stops For Permit 16010035
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-01-13 Cont ID  
Sent By cthroop Date 2016-01-13 Time 08:35 Rev Time 0.00
Received By cthroop Date 2016-01-13 Time 08:35 Sent To  
Notes
2016-01-13 08:41:09CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 PROVIDE WIND SPEED DESIGN CALCULATIONS.
 PROVIDE FASTENER SCHEDULE.
 DESIGNER TO SIGN DRAWING.
  
 FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2. THE STRUCTURAL
 CONNECTION DETAILS ARE NOT SPECIFIC AS TO QUANTITY AND
 SPACING OF THE CONNECTORS.
  
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-01-11 Cont ID  
Sent By fmittner Date 2016-01-11 Time 12:00 Rev Time 0.00
Received By fmittner Date 2016-01-11 Time 12:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-13 Cont ID  
Sent By cthroop Date 2016-01-13 Time 08:35 Rev Time 0.00
Received By cthroop Date 2016-01-04 Time 15:42 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-01-11 Cont ID  
Sent By cthroop Date 2016-01-13 Time 08:35 Rev Time 0.00
Received By fmittner Date 2016-01-11 Time 12:00 Sent To B
Notes
2016-01-11 12:01:25PERMENANT STRUCTURE IN FRONT SETBACK NOT PERMITTED
 (25')