Plan Review Details - Permit 15120879
Plan Review Stops For Permit 15120879 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-02-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-02-12 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-02-12 |
Time |
15:48 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-01-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-01-19 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-01-19 |
Time |
15:35 |
Sent To |
E |
|
Notes |
2016-01-19 16:50:16 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 1- THE CURRENT CODE IS THE FBC-RESIDENTIAL , 5TH | | EDITION (2014) NOT "FBC 2010 CHARTER 609A-C-ASCE | | 7-10".. REVISE AS REQUIRED BY CHAPTER 553 FLORIDA | | STATUTES. | | | | 2- PROVIDE THE NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. 107.2.1 | | CITY AMENDMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-02-11 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-02-11 |
Time |
18:33 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-02-11 |
Time |
18:33 |
Sent To |
|
|
Notes |
2016-02-11 18:34:07 | NEC 210.63 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-01-21 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-01-21 |
Time |
19:07 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-01-21 |
Time |
19:07 |
Sent To |
|
|
Notes |
2016-01-21 19:10:16 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6700 | | [email protected] | | ALTERNATE CONTACT | | MIKE ALBARRAN | | 561-805-6746 | | [email protected] | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | ELECTRONIC MEDIA DOCUMENTS SHALL BE | | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | PLEASE SHOW CONDENSOR UNIT AND AHU ON FLOOR PLANS | | PLEASE PROVIDE NAMEPLATE RATING OF AC EQUIPMENT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-02-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2016-02-19 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2016-02-04 |
Time |
08:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-01-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-01-22 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-12-29 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-02-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2016-02-19 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2016-02-16 |
Time |
14:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-01-07 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2016-01-07 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2016-01-07 |
Time |
12:39 |
Sent To |
|
|
Notes |
2016-01-07 13:05:29 | PLAN DENIED | | 1) MISSING DUCT SIZE OF DUCT GOING INTO EXISTING LIVING | | ROOM | | SECTION 107 FBC. | | 2) SHOW LOCATION OF THE CONDENSER ON THE PLAN | | SECTION107 FBC | | 3) NEED SIGNATURE OF WHO EVER DREW THE PLAN AND | | LICENSE NUMBER. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-02-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-02-12 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-02-12 |
Time |
16:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-01-04 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-01-04 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-01-04 |
Time |
16:02 |
Sent To |
|
|
Notes |
|
|
|