Plan Review Details - Permit 15120285
Plan Review Stops For Permit 15120285
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-12-28 Cont ID  
Sent By rmcdouga Date 2015-12-28 Time 18:12 Rev Time 0.00
Received By rmcdouga Date 2015-12-28 Time 17:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-12-09 Cont ID  
Sent By rmcdouga Date 2015-12-09 Time 19:01 Rev Time 0.00
Received By rmcdouga Date 2015-12-09 Time 18:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-12-28 Cont ID  
Sent By rmcdouga Date 2015-12-28 Time 18:13 Rev Time 0.00
Received By rmcdouga Date 2015-12-28 Time 17:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-12-09 Cont ID  
Sent By rmcdouga Date 2015-12-09 Time 19:01 Rev Time 0.00
Received By rmcdouga Date 2015-12-09 Time 18:37 Sent To  
Notes
2015-12-09 19:01:03PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PROVIDE SPECIFIC LANGUAGE AND OR DETAILS ON THE
 DRAWINGS THAT SHOWS COMPLIANCE WITH FBCR-E 4204.42 FOR
 THE REQUIRED BONDING OF POOL STEEL, METAL PARTS AND
 EQUIPMENT, AS WELL AS, EQUIPOTENTIAL BONDING.
 FBC107.2.1
  
 2) SHOW COMPLIANCE WITH FBCR-E4204.3 FOR BONDING OF
 POOL WATER.

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2015-12-28 Cont ID  
Sent By rmcdouga Date 2015-12-28 Time 18:12 Rev Time 0.00
Received By rmcdouga Date 2015-12-28 Time 17:37 Sent To  
Notes
2015-12-28 18:12:45A SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED
 FOR GAS.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2015-12-09 Cont ID  
Sent By rmcdouga Date 2015-12-09 Time 18:46 Rev Time 0.00
Received By rmcdouga Date 2015-12-09 Time 18:37 Sent To  
Notes
2015-12-09 18:47:52A SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED
 FOR GAS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-28 Cont ID  
Sent By rmcdouga Date 2015-12-28 Time 18:13 Rev Time 0.00
Received By rmcdouga Date 2015-12-15 Time 10:26 Sent To  
Notes
2015-12-22 12:52:0412/22 TO RM DESK
  
  
2015-12-15 10:26:21RESUB ROUTED TO SGRAHAM

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-12-09 Cont ID  
Sent By rmcdouga Date 2015-12-09 Time 19:01 Rev Time 0.00
Received By rmcdouga Date 2015-12-08 Time 16:53 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-12-28 Cont ID  
Sent By rmcdouga Date 2015-12-28 Time 18:04 Rev Time 0.00
Received By rmcdouga Date 2015-12-28 Time 17:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-12-09 Cont ID  
Sent By rmcdouga Date 2015-12-09 Time 18:47 Rev Time 0.00
Received By rmcdouga Date 2015-12-09 Time 18:37 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2015-12-17 Cont ID  
Sent By sgraham Date 2015-12-17 Time 15:25 Rev Time 0.00
Received By sgraham Date 2015-12-17 Time 15:25 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-12-09 Cont ID  
Sent By rmcdouga Date 2015-12-09 Time 19:01 Rev Time 0.00
Received By sgraham Date 2015-12-09 Time 09:56 Sent To B
Notes
2015-12-09 09:57:2212/9/15 ZONING FAILED
  
 1. DECK MUST BE 3' FEET FROM SIDE PRPERTY LINE.