Plan Review Stops For Permit 15120285 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-28 |
Time |
18:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-28 |
Time |
17:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-09 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-09 |
Time |
18:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-28 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-28 |
Time |
17:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-09 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-09 |
Time |
18:37 |
Sent To |
|
|
Notes |
2015-12-09 19:01:03 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY ELECTRICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) PROVIDE SPECIFIC LANGUAGE AND OR DETAILS ON THE | | DRAWINGS THAT SHOWS COMPLIANCE WITH FBCR-E 4204.42 FOR | | THE REQUIRED BONDING OF POOL STEEL, METAL PARTS AND | | EQUIPMENT, AS WELL AS, EQUIPOTENTIAL BONDING. | | FBC107.2.1 | | | | 2) SHOW COMPLIANCE WITH FBCR-E4204.3 FOR BONDING OF | | POOL WATER. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-28 |
Time |
18:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-28 |
Time |
17:37 |
Sent To |
|
|
Notes |
2015-12-28 18:12:45 | A SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED | | FOR GAS. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-09 |
Time |
18:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-09 |
Time |
18:37 |
Sent To |
|
|
Notes |
2015-12-09 18:47:52 | A SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED | | FOR GAS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-28 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-15 |
Time |
10:26 |
Sent To |
|
|
Notes |
2015-12-22 12:52:04 | 12/22 TO RM DESK | | | | | 2015-12-15 10:26:21 | RESUB ROUTED TO SGRAHAM |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-09 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-08 |
Time |
16:53 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-28 |
Time |
18:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-28 |
Time |
17:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-09 |
Time |
18:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-09 |
Time |
18:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-12-17 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-12-17 |
Time |
15:25 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-09 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-12-09 |
Time |
09:56 |
Sent To |
B |
|
Notes |
2015-12-09 09:57:22 | 12/9/15 ZONING FAILED | | | | 1. DECK MUST BE 3' FEET FROM SIDE PRPERTY LINE. |
|
|