Plan Review Details - Permit 15120168
Plan Review Stops For Permit 15120168 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-15 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-15 |
Time |
07:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-12-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-10 |
Time |
07:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-10 |
Time |
07:51 |
Sent To |
|
|
Notes |
2015-12-10 07:51:05 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | 2) SPECIFY THE WIND LOAD DESIGN DATA FOR THE CBS WALL | | ON THE PLAN. FBC-R301.2.1 | | | | 3) SPECIFY THE SPACING OF THE #5 VERTICAL REINFORCING | | BARS ON THE PLAN. FBC 107.2.1 | | | | 4) THE FOOTER REINFORCEMENT CALLS FOR 4 #5 REBARS EACH | | WAY. THIS DOES NOT MAKE ANY SENSE FOR A CONTINOUS | | FOOTING. PLEASE REVISE. FBC 107.2.1 | | | | 5) THE VALUATION OF $1500.00 IS NOT ADEQUATE FOR A 6' | | HIGH CBS WALL AND FOOTING THAT IS 75 FEET IN LENGTH. | | BASED ON MARSHALL & SWIFT VALUATION GUIDE THE VALUE OF | | THIS WALL IS $5,490.00. I HAVE ADJUSTED THE PERMIT | | VALUATION ACCORDINGLY. FBC 109.3 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-12-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-15 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-11 |
Time |
09:07 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-12-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-10 |
Time |
07:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-03 |
Time |
12:52 |
Sent To |
|
|
Notes |
2015-12-03 12:52:23 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-12-08 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-12-08 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-12-08 |
Time |
14:31 |
Sent To |
B |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |