Plan Review Details - Permit 15120024
Plan Review Stops For Permit 15120024
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2016-04-21 Cont ID  
Sent By jwitmer Date 2016-04-21 Time 11:28 Rev Time 0.00
Received By jwitmer Date 2016-04-21 Time 10:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-02-23 Cont ID  
Sent By jwitmer Date 2016-02-23 Time 08:21 Rev Time 0.00
Received By jwitmer Date 2016-02-23 Time 07:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-01-28 Cont ID  
Sent By jwitmer Date 2016-01-28 Time 06:45 Rev Time 0.00
Received By jwitmer Date 2016-01-28 Time 06:06 Sent To  
Notes
2016-01-28 06:49:24BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15120024
 ADD: 312 23RD ST.
 CONT: ROYAL PALM POOLS
 TEL: 561-798-3711
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
  
 2ND REVIEW
 DATE: THURS. JAN. 28/2016
 ACTION: DENIED
  
 1) 2ND REQUEST. THERE HAS BEEN NO REVISION TO THE
 MASTER SET OF PLANS SUBMITTED SHOWING THE POOL
 PLACEMENT MATCHING THE LAYOUT OF THE POOL PERMIT SET OF
 DRAWINGS. THERE IS A DISCREPANCY IN THE MATER BUILDING
 PERMIT 14120431 AND THE LAY OUT OF THE POOL PERMITTED
 SET OF PLANS. THE MATER BUILDING PERMIT SHOWS THE
 STAIRS ON THE WEST END OF THE POOL (SEE SHEETS A-2.00 &
 A-3.40) WHERE AS THE SUBMITTED POOL PLANS INDICATE THE
 STAIRS AND SHALLOW END OF THE POOL AT THE EAST END OF
 THE POOL. DISCREPANCY IN PLANS. 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 2) COMPLIED. SHEET 4 OF 4 POOL EQUIPMENT NOTE 11
 INDICATES THERE IS TO BE A POOL GAS FIRED HEATER. SPEC
 SHEET SUBMITTED IS FOR MASTERTEMP HEATERS A GENERIC
 SPEC SHEET OF THEIR PRODUCTS. PLEASE IDENTIFY WHICH OF
 THEIR PRODUCTS (MODEL), GAS TYPE PROPANE OR NATURAL,
 AND BTU'S. 2014 FLORIDA BUILDING CODE W 2014 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATION 107.2.1.3 ADDITIONAL INFORMATION IS
 REQUIRED.
  
 3) PLEASE SHOW COMPLIANCE WITH 2014 FBC-ENERGY C404.7.1
 POOL HEATERS. ALL POOL HEATERS SHALL MEET THE MINIMUM
 EFFICIENCY LISTED FOR THAT TYPE OF POOL HEATER IN TABLE
 C404.2 AND BE EQUIPPED WITH A READILY ACCESSIBLE ON-OFF
 SWITCH THAT IS MOUNTED OUTSIDE OF THE HEATER TO ALLOW
 SHUTTING OFF THE HEATER WITHOUT ADJUSTING THE
 THERMOSTAT SETTING.. CONTRACTOR IS TO SUBMIT HEATER
 SPECS TO THE ENGINEER OF RECORD FOR REVIEW AND SIGN OFF
 ON THE SHOP DRAWING FOR APPROVAL BEFORE SUBMITTAL TO
 THE BUILDING DEPARTMENT.
  
 4) PLEASE SHOW COMPLIANCE WITH 2014 FBC-ENERGY C404.7.1
 POOL HEATERS. GAS-FIRED HEATERS SHALL NOT BE EQUIPPED
 WITH CONSTANT BURNING PILOT LIGHTS.
 . CONTRACTOR IS TO SUBMIT HEATER SPECS TO THE ENGINEER
 OF RECORD FOR REVIEW AND SIGN OFF ON THE SHOP DRAWING
 FOR APPROVAL BEFORE SUBMITTAL TO THE BUILDING
 DEPARTMENT.
  
 5-9) COMPLIED.
  
 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-12-31 Cont ID  
Sent By jwitmer Date 2015-12-31 Time 09:45 Rev Time 0.00
Received By jwitmer Date 2016-01-28 Time 06:39 Sent To  
Notes
2015-12-31 09:31:26BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15120024
 ADD: 312 23RD ST.
 CONT: ROYAL PALM POOLS
 TEL: 561-798-3711
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
  
 1ST REVIEW
 DATE: THURS. DEC.31/2015
 ACTION: DENIED
  
 1) THERE IS A DISCREPANCY IN THE MATER BUILDING PERMIT
 14120431 AND THE LAY OUT OF THE POOL PERMITED SET OF
 PLANS. THE MATER BUILDING PERMIT SHOWS THE STAIRS ON
 THE WEST END OF THE POOL (SEE SHEETS A-2.00 & A-3.40)
 WHERE AS THE SUBMITTED POOL PLANS INDICATE THE STAIRS
 AND SHALLOW END OF THE POOL AT THE EAST END OF THE
 POOL. DISCREPANCY IN PLANS. 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 2) SHEET 4 OF 4 POOL EQUIPMENT NOTE 11 INDICATES THERE
 IS TO BE A POOL GAS FIRED HEATER. SPEC SHEET SUBMITTED
 IS FOR MASTERTEMP HEATERS A GENERIC SPEC SHEET OF THEIR
 PRODUCTS. PLEASE IDENTIFY WHICH OF THEIR PRODUCTS
 (MODEL), GAS TYPE PROPANE OR NATURAL, AND BTU'S. 2014
 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS
 TO THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED.
  
 3) PLEASE SHOW COMPLIANCE WITH 2014 FBC-ENERGY C404.7.1
 POOL HEATERS. ALL POOL HEATERS SHALL MEET THE MINIMUM
 EFFICIENCY LISTED FOR THAT TYPE OF POOL HEATER IN TABLE
 C404.2 AND BE EQUIPPED WITH A READILY ACCESSIBLE ON-OFF
 SWITCH THAT IS MOUNTED OUTSIDE OF THE HEATER TO ALLOW
 SHUTTING OFF THE HEATER WITHOUT ADJUSTING THE
 THERMOSTAT SETTING.
  
 4) PLEASE SHOW COMPLIANCE WITH 2014 FBC-ENERGY C404.7.1
 POOL HEATERS. GAS-FIRED HEATERS SHALL NOT BE EQUIPPED
 WITH CONSTANT BURNING PILOT LIGHTS.
  
 5) SHEET 4 OF 4 THE POOL ELECTRIC DIAGRAM SHOWS THE
 POOL HEATER BUT THERE IS NO MENTION OF TIME SWITCHES OR
 OTHER CONTROL METHOD THAT CAN AUTOMATICALLY TURN OFF
 AND ON HEATERS AND PUMPS ACCORDING TO A PRESET SCHEDULE
 SHALL BE INSTALLED ON ALL HEATERS AND PUMPS. HEATERS,
 PUMPS AND MOTORS THAT HAVE BUILT IN TIMERS SHALL BE
 DEEMED IN COMPLIANCE WITH THIS REQUIREMENT. SHOW
 COMPLIANCE WITH 2014 FBC-ENERGY CODE C404.7.2.
  
 6) PLEASE PROVIDE COMPLIANCE WITH SECTION OF THE 2014
 FBC-ENERGY C404.7.3 COVERS. HEATED SWIMMING POOLS AND
 INGROUND PERMANENTLY INSTALLED SPAS SHALL BE EQUIPPED
 WITH A VAPOR-RETARDANT COVER ON OR AT THE WATER SURFACE
 OR A LIQUID COVER OR OTHER MEANS PROVEN TO REDUCE HEAT
 LOSS.
  
 7) SHEET 1 OF 4 SHOWS THE POOL SIZE OF 16 X 40 FEET OR
 112 LINEAR FEET OF PERMITER. PLEASE NOTE THE MATER
 PERMIT WAS ISSUED AS A R2 OCCUPANCY THERE ARE AREAS OF
 THE PLANS THAT DEAL WITH FLORIDA ACCESSIBLITY AND AREAS
 THAT ARE STRICTLY FAIR HOUSING. IT IS NOT KNOWN WHAT
 THE FINAL USE WILL BE A CONDOMINIUM UNDER FAIR HOUSING
 OR IF IT MAY BE AN APARTMENT BUILDING (TRANSIENT) THAT
 COULD BE UNDER FLORIDA ACCESSIBLITY. THIS COMMENT MAY
 BE RELEVANT OR NOT DEPENDING ON THE FINAL USAGE.
 PLEASE PROVIDE COMPLIANCE WITH 2014 FBC-B 454.1.2.5.6
 DISABLED ACCESS. PERMANENT OR PORTABLE STEPS, RAMPS,
 HANDRAILS, LIFTS OR OTHER DEVICES DESIGNED TO
 ACCOMMODATE HANDICAPPED INDIVIDUALS IN SWIMMING POOLS
 MAY BE PROVIDED. LIFTS MOUNTED INTO THE POOL DECK SHALL
 HAVE A MINIMUM 4-FOOT-WIDE (1219 MM) DECK BEHIND THE
 LIFT MOUNT.
  
 2015 FBC-ACCESSIBILITY CODE 242.2 SWIMMING POOLS.
 AT LEAST TWO ACCESSIBLE MEANS OF ENTRY SHALL BE
 PROVIDED FOR SWIMMING POOLS. ACCESSIBLE MEANS OF ENTRY
 SHALL BE SWIMMING POOL LIFTS COMPLYING WITH 1009.2;
 SLOPED ENTRIES COMPLYING WITH 1009.3; TRANSFER WALLS
 COMPLYING WITH 1009.4; TRANSFER SYSTEMS COMPLYING WITH
 1009.5; AND POOL STAIRS COMPLYING WITH 1009.6. AT LEAST
 ONE ACCESSIBLE MEANS OF ENTRY PROVIDED SHALL COMPLY
 WITH 1009.2 OR 1009.3.
  
 EXCEPTIONS: 1. WHERE A SWIMMING POOL HAS LESS THAN 300
 LINEAR FEET (91 M) OF SWIMMING POOL WALL, NO MORE THAN
 ONE ACCESSIBLE MEANS OF ENTRY SHALL BE REQUIRED
 PROVIDED THAT THE ACCESSIBLE MEANS OF ENTRY IS A
 SWIMMING POOL LIFT COMPLYING WITH 1009.2 OR SLOPED
 ENTRY COMPLYING WITH 1009.3.
  
 2014 FBC-ACCESSIBILITY 1009.1 GENERAL. WHERE PROVIDED,
 POOL LIFTS, SLOPED ENTRIES, TRANSFER WALLS, TRANSFER
 SYSTEMS, AND POOL STAIRS SHALL COMPLY WITH 1009.
  
 8) PLEASE SHOW COMPLIANCE WITH 2014 FBC-B 454.1.3.3.1
 REQUIRED SAFETY EQUIPMENT.
  
 9) SHEET 1 OF 4 SHOWS A LARGE POOL EQUIPMENT ROOM.
 CONCERNS ARE COMPLYING WITH :
 9A) 2014 FBC-B 454.1.5.4 VENTILATION. EQUIPMENT ROOMS
 SHALL HAVE EITHER FORCED DRAFT OR CROSS VENTILATION.
 ALL BELOW-GRADE EQUIPMENT ROOMS SHALL HAVE A STAIRWAY
 ACCESS WITH FORCED DRAFT VENTILATION OR A FULLY
 LOUVERED DOOR AND POWERED INTAKE WITHIN 6 INCHES (152
 MM) OF THE FLOOR.
  
 9B) 2014 FBC-B 454.1.5.8 STORAGE. EQUIPMENT ENCLOSURES,
 ROOMS OR AREAS SHALL NOT BE USED FOR STORAGE OF
 CHEMICALS EMITTING CORROSIVE FUMES OR FOR STORAGE OF
 OTHER ITEMS TO THE EXTENT THAT ENTRANCE TO THE ROOM FOR
 INSPECTION OR OPERATION OF THE EQUIPMENT IS IMPAIRED.
  
 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-04-11 Cont ID  
Sent By mvaldes Date 2016-04-11 Time 14:20 Rev Time 0.00
Received By mvaldes Date 2016-04-11 Time 14:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-01-27 Cont ID  
Sent By mvaldes Date 2016-01-27 Time 10:06 Rev Time 0.00
Received By mvaldes Date 2016-01-27 Time 10:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-12-14 Cont ID  
Sent By mvaldes Date 2015-12-14 Time 18:17 Rev Time 0.00
Received By mvaldes Date 2015-12-14 Time 16:10 Sent To  
Notes
2015-12-14 18:23:201ST REVIEW: FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 PHIL PETTY
 561-805-6742
 [email protected]
  
  
 SEPERATE PERMIT FOR ELECTRICAL

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2015-12-18 Cont ID  
Sent By tklarge Date 2015-12-18 Time 07:16 Rev Time 0.00
Received By tklarge Date 2015-12-18 Time 07:16 Sent To  
Notes
2015-12-18 07:17:50GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-04-22 Cont ID  
Sent By jroach Date 2016-04-22 Time 12:05 Rev Time 0.00
Received By jroach Date 2016-03-29 Time 11:01 Sent To  
Notes
2016-03-30 11:02:11POOL BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-02-23 Cont ID  
Sent By jwitmer Date 2016-02-23 Time 08:21 Rev Time 0.00
Received By jwitmer Date 2016-02-17 Time 09:54 Sent To  
Notes
2016-02-18 09:55:01RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-01-28 Cont ID  
Sent By jwitmer Date 2016-01-28 Time 06:45 Rev Time 0.00
Received By jwitmer Date 2016-01-20 Time 10:50 Sent To  
Notes
2016-01-21 10:50:36RESUB ROUTED TO JROACH VIA SGRAHAM'S DESK - PLACE IN
 POOL BOX AFTER STAMP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-12-31 Cont ID  
Sent By jwitmer Date 2015-12-31 Time 09:45 Rev Time 0.00
Received By jwitmer Date 2015-12-01 Time 16:52 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2016-04-06 Cont ID  
Sent By tklarge Date 2016-04-06 Time 06:42 Rev Time 0.00
Received By tklarge Date 2016-04-06 Time 06:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2016-02-20 Cont ID  
Sent By tklarge Date 2016-02-20 Time 03:42 Rev Time 0.00
Received By tklarge Date 2016-02-20 Time 03:19 Sent To  
Notes
2016-02-20 03:42:421)THE PLAN SHOWS THE POOL WASTEWATER LINE DISCHARGING
 TO THE STORM SEWER. POOL WATER IS PROHIBITED FROM
 DISCHARGING TO THE STORM OR SANITARY SYSTEM PER CITY
 ORDINANCE # 90-126 (B) & 90-203 (A). SPECIFY WHERE THE
 WASTEWATER WILL DISCHARGE.3ND REQUEST.
 2) 2014 FBCB SEC. 454.1.5.4 REQUIRES VENTILATION IN THE
 EQUIPMENT ROOM. SUBMIT REQUIRED VENTILATION
 CALCULATIONS FOR REVIEW. 3ND REQUEST. THE PLAN NOTES
 "VENTILATION BY OTHERS." I NEED TO KNOW HOW COMPLIANCE
 WITH THIS CODE SECTION WILL BE MET.
 3) SUBMIT MSDS SHEETS FOR THE CHEMICALS IN THE PH TANK
 & CHEMICAL FEEDER.WPB SEC. 107.2.1.3RD REQUEST.
  
 I SUGGEST SETTING AN APPOINTMENT TO REVIEW THE PLAN
 REVIEW COMMENTS TO HELP GET THE PLUMBING APPROVED.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-01-27 Cont ID  
Sent By tklarge Date 2016-01-27 Time 05:41 Rev Time 0.00
Received By tklarge Date 2016-01-27 Time 05:29 Sent To  
Notes
2016-01-27 05:40:521)THE PLAN SHOWS THE POOL WASTEWATER LINE DISCHARGING
 TO THE STORM SEWER. POOL WATER IS PROHIBITED FROM
 DISCHARGING TO THE STORM OR SANITARY SYSTEM PER CITY
 ORDINANCE # 90-126 (B) & 90-203 (A). SPECIFY WHERE THE
 WASTEWATER WILL DISCHARGE.2ND REQUEST.
 2) 2014 FBCB REQUIRES VENTILATION IN THE EQUIPMENT
 ROOM. SUBMIT REQUIRED VENTILATION CALCULATIONS FOR
 REVIEW. 2ND REQUEST
 3) SUBMIT MSDS SHEETS FOR THE CHEMICALS IN THE PH TANK
 & CHEMICAL FEEDER.WPB SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-12-18 Cont ID  
Sent By tklarge Date 2015-12-18 Time 07:15 Rev Time 0.00
Received By tklarge Date 2015-12-18 Time 04:09 Sent To  
Notes
2015-12-18 06:20:551) IDENTIFY THE MODEL OF THE GAS HEATER ON THE
 MANUFACTURER'S SPECIFICATION SHEET AND IF IT IS NATURAL
 OR LP GAS. WPB AMEND. TO FBC SEC. 107.2.1.
 2) SHT. 3 OF 4 IN THE POOL SPECIFICATIONS INDICATES A
 FEATURE PUMP BUT NONE IS SHOWN ON THE PIPING DIAGRAM.
 CLARIFY.
 3) THE PLANS SHOW THE POOL WASTE LINE DISCHARGING TO
 THE SANITERY SEWER. POOL WATER IS PROHIBITED FROM
 DISCHARGING TO THE SANITARY OR STORM SYSTEMS PER CITY
 ORDINANCE 90-126 ( B ) (5) & 90-203 ( A).
 4) WHERE DOES THE FLOOR DRAIN TERMINATE? THE FLOOR
 DRAIN SHALL BE EQUIPPED WITH A TRAP PRIMER. SUBMIT A
 RISER DIAGRAM FOR THE SANITARY AND WATER LINES IN THE
 POOL EQUIPMENT ROOM. WPB AMEND. TO FBC SEC. 107.2.1.
 5) IDENTIFY THE FIXTURES IN THE POOL EQUIPMENT ROOM.
 THERE APPEARS TO BE A SINK AND A SERVICE SINK.CLARIFY.
 6) SUBMIT MANUF. SPECS. ON THE MAIN DRAIN AND THE
 SKIMMERS.
 7) SHT. 1 NOTES A 3 INCH WASTE LINE AND SHEET 4 IN THE
 POOL LEGEND SHOWS 1 1/2 INCH WASTE LINE. CLARIFY. WPB
 AMEND. TO FBC SEC. 107.2.1.
 8) INDICATE THE CAPACITY OF THE CL2 TANK AND THE PH
 TANK AND SUBMIT MSDS SHEETS FOR THE CHEMICALS.WPB
 AMEND. TO FBC SEC. 107.2.1.
 9) 2014 FBC SEC.454.1.5.4 REQUIRES VENTILATION IN THE
 EQUIPMENT ROOM. SUBMIT REQUIRED CALCULATIONS.
 10) PIPING AND INFLUENT, EFFLUENT AND BYPASS VALVES
 WHICH ALLOW ISOLATION OR REMOVAL OF THE HEATER FROM THE
 SYSTEM SHALL BE PROVIDED. 2014 FBC SEC.454.1.6.5.14.
 11) THE POOL HEATER SHALL BE EQUIPPED WITH A READILY
 ACCESSIBLE ON-OFF SWITCH THAT IS MOUNTED OUTSIDE THE
 HEATER TO ALLOW SHUTTING OF THE HEATER WITHOUT
 ADJUSTING THE THERMOSTAT. 2014 FBC-ENERGY SEC.C404.7.1.
 12) TIME SWITCHES OR OTHER CONTROL METHOD THAT CAN
 AUTOMATICALLY TURN OFF AND ON HEATERS AND PUMPS
 ACCORDING TO A PRESET SCHEDULE SHALL BE INSTALLED ON
 ALL HEATERS AND PUMPS. FBC-ENERGY SEC. C 404.7.2.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2016-04-22 Cont ID  
Sent By jroach Date 2016-04-22 Time 12:05 Rev Time 0.00
Received By jroach Date 2016-04-22 Time 12:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-01-26 Cont ID  
Sent By jroach Date 2016-01-26 Time 09:10 Rev Time 0.00
Received By jroach Date 2016-01-26 Time 09:10 Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-12-08 Cont ID  
Sent By jwitmer Date 2015-12-31 Time 09:45 Rev Time 0.00
Received By jroach Date 2015-12-08 Time 16:39 Sent To E
Notes
***NONE***