Plan Review Stops For Permit 15111015 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-12-10 |
|
|
Cont ID |
|
Sent By |
|
Date |
2015-12-10 |
Time |
06:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-12-10 |
Time |
05:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-16 |
Time |
18:00 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-12-16 |
Time |
15:41 |
Sent To |
|
|
Notes |
2015-12-16 18:01:26 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | 1. ELECTRICAL SPECIFICATIONS SECTION ON SHEET E0.1 | | MISQUOTED FBC-E SECTIONS: FBC-EC405.7.3 VOLTAGE DROP. | | FEEDERS & CUSTOMER OWNED SERVICE CONDUCTORS SHALL BE | | SIZED FOR A MAXIMUM OF 2% VOLTAGE DROP. BRANCH CIRCUITS | | SHALL BE SIZED FOR A MAXIMUM OF 3% VOLTAGE DROP. | | 2. TRENCHING FOR FPL CONDUCTORS BETWEEN EXISTING POLE | | AND THE PROPOSED FPL TRANSFORMER, IF UNDER THE SCOPE OF | | THIS PERMIT, AS WELL AS ALL OTHER UNDERGROUND WIRING | | SHALL REMAIN OPEN FOR INSPECTION UNLESS PRIOR | | ARRANGEMENTS ARE MADE WITH ELECTRICAL INSPECTOR, OR RUN | | VIA DIRECT BORING. SHEET E2.1 | | 3. FBC 1006.1 MEANS OF EGRESS ILLUMINATION REQUIRED. | | THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, | | SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE | | SERVED BY THE MEANS OF EGRESS ARE OCCUPIED. SHEET E2.1 | | 4. THE SERVICE RACK SHALL BE GUARDED AGAINST PHYSICAL | | DAMAGE AS INDICATED IN NEC 110.27(B). SHEET E2.1 | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | INSERT CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | | | EMAIL: [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
N |
Date |
2015-12-23 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2015-12-23 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2015-12-23 |
Time |
10:32 |
Sent To |
|
|
Notes |
2015-12-23 13:26:02 | SPOKE WITH ROBERT BROWN, BUILDING OFFICIAL, AND KELLY | | CRANFORD, ENGINEERING PLAN REVIEWER, AND BASED ON THE | | CONVERSATIONS AND NOTES, A "NOT REQUIRED" RESULT IS | | ADDED TO THE ENGINEERING STOP AT THIS TIME. THIS WILL | | BE CONSIDERED PHASE 1 OF THE PROCESS AND INCLUDE ONLY | | THE SUPERINTENDENTS TRAILER AND INSTALLATION OF SAME. | | NO ELECTRIC OR WATER IS BEING CONSIDERED AT THIS TIME. | | SEPARATE PERMITS FOR ELECTRIC AND WATER, WITH COMPLIANT | | DRAWINGS ARE REQUIRED FOR THOSE PORTIONS OF THE WORK | | AND WILL BE SUBMITTED IN THE ANTICIPATED NEAR FUTURE. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-12-17 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-12-17 |
Time |
13:16 |
Sent To |
|
|
Notes |
2015-12-17 13:34:17 | ONCE THE PROPOSED POTABLE WATER SERVICE LINE IS NO | | LONGER UTILIZED, THE LINE IS TO BE REMOVED BACK TO THE | | MAIN. (SECTION 2.23 OF THE CITY RIGHT OF WAY | | CONSTRUCTION STANDARDS MANUAL) | | | | PLEASE UPDATE THE DETAIL SHEETS TO UTILIZE THE MOST | | RECENT VERSION OF THE CITY OF WEST PALM BEACH DETAILS. | | DETAILS MAY BE DOWNLOADED AT | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ . | | PAVEMENT RESTORATION WITHIN THE HAVERHILL RIGHT-OF-WAY | | MUST COMPLY WITH PALM BEACH COUNTY STANDARDS. | | | | PLEASE SUBMIT A LEGIBLE COPY OF THE SITE PLAN, SHEET | | SP-1. | | | | AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL BE | | REQUIRED FROM THE ENGINEERING DIVISION OF THE PUBLIC | | WORKS DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL | | APPLICATION FORMS CAN BE DOWNLOADED AT | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | KELLY CRANFORD, P.E. | | CAPITAL IMPROVEMENT PLAN MANAGER | | [email protected] | | 561-494-1098 (OFFICE) | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-12-02 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-12-02 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-12-02 |
Time |
13:58 |
Sent To |
|
|
Notes |
2015-12-02 15:35:18 | 5444 NORTH HAVERHILL ROAD - CONSTRUCTION TRAILERS | | PERMIT #15111015 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | WEST TRAILER EXITS (X3) APPEAR TO DISCHARGE INTO THE | | GRASS. EXIT DISCHARGES SHALL BE ILLUMINATED AND SHALL | | TERMINATE AT A PUBLIC WAY SUCH AS A SIDEWALK, STREET, | | PARKING LOT, ETC. | | | | PER SECTION 10.12.1.2 (NFPA 1), PROVIDE BUILDING | | ADDRESS VISIBLE FROM THE STREET. NUMBERS SHALL BE | | ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES IN | | HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE | | BACKGROUND. | | | | STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS | | CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO | | THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS | | 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED | | REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R | | DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA | | ADMINISTRATIVE CODE 69A-60.0081. | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | EXIT SIGNS. | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | NOTE: SEPARATE PLANS AND PERMITS NEEDED FOR PRIVATE | | UNDERGROUND FIRE LINE/FIRE HYDRANT AND FIRE SPRINKLER | | SYSTEM. | | | | NOTE: REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE | | THE OWNER, CONTRACTOR, ETC. OF THE RESPONSIBILITY OF | | COMPLIANCE WITH CODE (NFPA 1, SECTION 1.14.4). FBC | | SECTION 105.4.1 PERMIT INTENT: A PERMIT ISSUED SHALL BE | | CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND | | NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE | | ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL | | ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM | | THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, | | CONSTRUCTION OR VIOLATIONS OF THIS CODE. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-12-17 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-12-01 |
Time |
14:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2015-12-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-12-08 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-12-08 |
Time |
10:06 |
Sent To |
|
|
Notes |
2015-12-08 10:16:56 | PROVISOS | | 12/8/15 | | | | 1) COMPLETE THE MANDATORY REQUIREMENTS CHECKLIST (SEE | | PAGE 7) ON EACH ENERGY COMPLIANCE FORM 506-2014 FOR THE | | MODULAR BUILDINGS. THE ENERGY FORMS MUST BE ON SITE AT | | TIME OF INSPECTION. | | 2) MANUFACTURER'S SPECIFICATIONS FOR THE AC UNITS SHALL | | BE ON-SITE AT TIME OF INSPECTION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-12-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-12-06 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-12-06 |
Time |
10:39 |
Sent To |
|
|
Notes |
2015-12-06 10:45:30 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING PROVISO | | | | | | | | PERMITS REQUIRED FROM HEALTH DEPTMENT FOR HOLDING TANKS | | BEFORE FINAL INSPECTION |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-12-07 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2015-12-07 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2015-12-07 |
Time |
14:31 |
Sent To |
|
|
Notes |
2015-12-07 14:35:45 | PLANNING AND ZONING COMMENTS: | | | | 12/7/15 | | | | 1. 'TEMPORARY OFFICES AND FACILITIES FOR CONSTRUCTIONS, | | STORAGE AND SECURITY' - ALL SUCH STRUCTURES, INCLUDING | | TRAILERS, SHALL BE REMOVED WITHIN SEVEN DAYS OF THE | | FINAL CONSTRUCTION INSPECTION BY THE CITY AND PRIOR TO | | THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY IN | | ACCORDANCE WITH ZLDR SEC. 94-273(D)(74). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | |
|
|