Plan Review Details - Permit 15110823
Plan Review Stops For Permit 15110823
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-03-17 Cont ID  
Sent By shill Date 2016-03-17 Time 11:32 Rev Time 0.00
Received By shill Date 2016-03-17 Time 11:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-02-29 Cont ID  
Sent By shill Date 2016-02-29 Time 18:29 Rev Time 0.00
Received By shill Date 2016-02-29 Time 18:29 Sent To  
Notes
2016-02-29 18:29:42****CORRECTIONS****
  
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE WORK FOR THIS PERMIT IS LOCATED ON THE LOT
 ASSOCIATED WITH 14120908; 4920 LORING DR. PLEASE
 PROVIDE A REVISED PERMIT APPLICATION.
 ***PLEASE NOTE THAT THIS MAY BE ADDRESSED AT ANY TIME.
 IT IS NOT NECESSARY TO WAIT UNTIL OTHER REVIEWS ARE
 COMPLETE OR TO RESUBMIT FOR THIS COMMENT. PLEASE ADVISE
 VIA EMAIL WHEN THIS IS COMPLETE.
  
 2. THIS PERMIT WILL BE ISSUED WITH PROVISO;
  
 SEPARATE PERMIT, FEES, REVIEW FOR COOLING TOWER
 EQUIPMENT REQUIRED (WILL NEED MECHANICAL & BUILDING
 REVIEWS)
 COOLING TOWER SUBMITTAL TO PROVIDE INFORMATION
 REGARDING WIND RESISTANCE FOR THE TOWER STRUCTURE FBC
 1609
  
 CONTRACTOR MAY ELECT TO RESUBMIT WITH ALL INFORMATION
 REQUIRED FOR THE COOLING TOWER EQUIPMENT, INCLUDING
 VALUE. VALUE ASSIGNED IS FOR THE WALL AND STRUCTURAL
 SUPPORT FOR THE TOWER. MECHANICAL/PLUMBING WERE NOT
 INCLUDED IN VALUE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-12-07 Cont ID  
Sent By shill Date 2015-12-07 Time 14:28 Rev Time 0.00
Received By shill Date 2015-12-07 Time 14:28 Sent To  
Notes
2015-12-07 14:29:40****CORRECTIONS****
 ****REVISED 12/14/15****
  
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE WORK FOR THIS PERMIT IS LOCATED ON THE LOT
 ASSOCIATED WITH 14120908; 4920 LORING DR. PLEASE
 PROVIDE A REVISED PERMIT APPLICATION.
 ***PLEASE NOTE THAT THIS MAY BE ADDRESSED AT ANY TIME.
 IT IS NOT NECESSARY TO WAIT UNTIL OTHER REVIEWS ARE
 COMPLETE OR TO RESUBMIT FOR THIS COMMENT. PLEASE ADVISE
 VIA EMAIL WHEN THIS IS COMPLETE.
  
 2. THIS PERMIT WILL BE ISSUED WITH PROVISO;
  
 SEPARATE PERMIT, FEES, REVIEW FOR COOLING TOWER
 EQUIPMENT REQUIRED (WILL NEED MECHANICAL & BUILDING
 REVIEWS)
 COOLING TOWER SUBMITTAL TO PROVIDE INFORMATION
 REGARDING WIND RESISTANCE FOR THE TOWER STRUCTURE FBC
 1609
  
 CONTRACTOR MAY ELECT TO RESUBMIT WITH ALL INFORMATION
 REQUIRED FOR THE COOLING TOWER EQUIPMENT, INCLUDING
 VALUE. VALUE ASSIGNED IS FOR THE WALL AND STRUCTURAL
 SUPPORT FOR THE TOWER. MECHANICAL/PLUMBING WERE NOT
 INCLUDED IN VALUE.
  
 *****ADDED ON 12/14/15
 3. PROVIDE SIGNATURE DOCUMENTS FOR 14120908 AND
 14120909.
  
 EITHER A DIGITAL SIGNATURE IS TO BE PROVIDED OR PAPER
 PLANS WHICH EXACTLY MATCH THE ISSUED PERMIT SET ARE TO
 BE PROVIDED.
  
  
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2016-05-04 Cont ID  
Sent By albarran Date 2016-05-04 Time 12:03 Rev Time 0.00
Received By albarran Date 2016-05-04 Time 11:01 Sent To  
Notes
2016-05-04 12:28:21STAMPED VOIDED ELECTRICAL SHEETS E002 & E602

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2016-03-29 Cont ID  
Sent By albarran Date 2016-03-29 Time 14:10 Rev Time 0.00
Received By albarran Date 2016-03-29 Time 11:10 Sent To  
Notes
2016-03-29 14:11:23CORRECTED SHEETS SUBMITTED MEETING ALL PRIOR REQUESTS.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2016-03-18 Cont ID  
Sent By albarran Date 2016-03-18 Time 11:31 Rev Time 0.00
Received By albarran Date 2016-03-17 Time 15:14 Sent To  
Notes
2016-03-18 11:32:393RD ELECTRICAL REVIEW NOTES FOR REVISION #:15110823
 REVIEWED FOR COMPLIANCE WITH: 5TH EDITION FBC 2014
 NFPA 70 2011 (NEC)
  
 CORRECTIONS REQUIRED:
 SHEET E213
 1. THE MANDATORY LIGHT CONTROL REQUIRED BY FBC-E
 SECTION 405 IS NOT DEFINED. THIS ALSO APPLIES TO
 COMMENT #4 WHICH ADDRESSES ENERGY MANAGEMENT AS WELL.
 2. THE WP GFI OUTLET SHOWN DOES NOT COMPLY WITH
 NEC406.9(B). NOTE MADE ON E008 AS WELL. PER NEC
 REQUIREMENTS, IN ADDITION TO THE IN-USE TYPE COVERS AND
 CAST BOXES, EVERY RECEPTACLE IN A WET LOCATION SHALL BE
 LISTED WEATHER RESISTANT. ADD NOTE TO SHEET E000 SYMBOL
 LEGEND AS WELL.
 SHEET E603
 1. RENAME CKT 5 TO MATCH RISER DIAGRAM ON E001
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2016-02-25 Cont ID  
Sent By albarran Date 2016-02-25 Time 14:38 Rev Time 0.00
Received By albarran Date 2016-02-25 Time 13:00 Sent To  
Notes
2016-02-25 14:40:292ND ELECTRICAL REVIEW NOTES FOR REVISION #:15110823
 REVIEWED FOR COMPLIANCE WITH:
 FBC 2010 EDITION
 NFPA 70 2008 (NEC)
  
 CORRECTIONS REQUIRED:
 SHEET E001 & E002
 1. DEFINE ON THIS RISER DIAGRAM THE AREA OR AREAS
 AFFECTED BY THIS PROJECT.
 SHEET E008
 1. YOU SUBMITTED A FIXTURE SCHEDULE THAT IS PROBABLY
 FOR THE MASTER PERMIT BUT HAVE NOT SUBMITTED ANY
 LIGHTING PLANS OR DESIGN FOR THIS SCOPE OF WORK.
 SHEET E201 & E213
 1. MISSING GROUNDING DETAIL 11 ON SHEET E701.
 2. MISSING TRANSFORMER SUPPORT DETAIL 3 ON SHEET E701.
 3. DEFINE THE AREA OF WORK ON THE FLOOR PLANS.
 4. YOU NEED TO SUBMIT A CODE COMPLIANT LIGHTING DESIGN
 FOR THE AREA IN QUESTION. THIS SHALL TAKE INTO
 CONSIDERATION ALL THE REQUIREMENTS OF THE FBC-ENERGY
 CONSERVATION.
 5. YOU SHALL INCLUDE THE REQUIRED EMERGENCY AND EXIT
 LIGHTS FOR THE WORK AREA.
 SHEET E602 & E603
 1. ONCE THE SCOPE OF WORK OR AREA OF WORK IS DEFINED
 AND THE LIGHTING PLAN PROVIDED THE PANEL AND CIRCUIT
 DESIGNATIONS CAN BE REVIEWED.
 SHEET G000
 1. CORRECT THE DRAWING SCHEDULE TO INCLUDE ALL OF AND
 ONLY THOSE SHEETS PERTINENT TO THIS PROJECT.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-02-10 Cont ID  
Sent By albarran Date 2016-02-10 Time 10:26 Rev Time 0.00
Received By albarran Date 2016-01-19 Time 13:04 Sent To  
Notes
2016-01-20 14:20:22THIS REVIEW HAS BEEN PLACED ON HOLD DUE TO INCORRECT
 ELECTRICAL PLAN SHEET SUBMITTAL. I SPOKE WITH MR. BILL
 GRANEY OF TLC AT (407) 489-1214. HE WILL RESEARCH THE
 MATTER AND SUBMIT CORRECTLY. STEVE KENNEDY & TEMPONE
 RYAN INFORMED OF THIS VIA EMAIL. MA

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2015-12-30 Cont ID  
Sent By cranford Date 2015-12-30 Time 10:11 Rev Time 0.00
Received By cranford Date 2015-12-30 Time 10:08 Sent To  
Notes
2015-12-30 10:11:06SEE E15080021 FOR ENGINEERING APPROVAL

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-12-11 Cont ID  
Sent By wjolin Date 2015-12-11 Time 11:58 Rev Time 0.00
Received By wjolin Date 2015-12-11 Time 11:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2016-05-04 Cont ID  
Sent By cpuell Date 2016-05-04 Time 17:26 Rev Time 0.00
Received By cpuell Date 2016-05-03 Time 15:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2016-04-23 Cont ID  
Sent By shill Date 2016-04-23 Time 13:21 Rev Time 0.00
Received By shill Date 2016-04-22 Time 15:51 Sent To  
Notes
2016-04-22 15:51:48SIGNATURES ROUTED TO SHILL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status F Date 2016-03-29 Cont ID  
Sent By cpuell Date 2016-03-29 Time 16:18 Rev Time 0.00
Received By cpuell Date 2016-03-23 Time 08:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-03-18 Cont ID  
Sent By lmarchan Date 2016-03-18 Time 11:38 Rev Time 0.00
Received By lmarchan Date 2016-03-10 Time 09:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-04 Cont ID  
Sent By cpuell Date 2016-03-04 Time 11:00 Rev Time 0.00
Received By cpuell Date 2016-02-16 Time 08:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-02-10 Cont ID  
Sent By cpuell Date 2016-02-10 Time 10:37 Rev Time 0.00
Received By cpuell Date 2015-12-08 Time 13:56 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2015-12-07 Cont ID  
Sent By shill Date 2015-12-07 Time 14:28 Rev Time 0.00
Received By shill Date 2015-12-07 Time 14:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2016-02-29 Cont ID  
Sent By ccole Date 2016-02-29 Time 11:11 Rev Time 0.00
Received By ccole Date 2016-02-25 Time 18:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-12-16 Cont ID  
Sent By ccole Date 2015-12-16 Time 14:28 Rev Time 0.00
Received By ccole Date 2015-12-16 Time 14:28 Sent To  
Notes
2015-12-16 14:45:081ST REVIEW 2014 MECHANICAL
 PERMIT 15110823
 12/16/15
  
 1) PLEASE ADJUST THE VALUE ON THE PERMIT APPLICATION TO
 INCLUDE THE COST OF THE PROJECT BASED ON LABOR,
 MATERIALS, EQUIPMENT, DESIGN FEES, OVERHEAD AND PROFIT
 ETC.- REFER TO SECTION 109.3 WPB AMENDMENTS TO THE
 FBC-14.
 2) SHEET S1.4: PROVIDE STRUCTURAL DETAILS FOR
 CONSTRUCTION OF THE COOLING TOWER STEEL SUPPORT BASE,
 AND ATTACHMENT OF TOWER TO THE SUPPORT BEAMS- SECTION
 301.15 FBC-14 MECHANICAL.
 3 )M1.0: PROVIDE ENGINEERED DETAILS FOR SUPPORT AND
 TIE-DOWN OF THE ABOVE GROUND CHILLER WATER SUPPLY AND
 RETURN PIPINGS.
 4) M1.0: INDICATE THE TYPE, THICKNESS, AND R-VALUE OF
 THE ABOVEGROUND CHILLED WATER PIPING INSULATION.
 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE COOLING
 TOWER REVIEWED AND APPROVED BY THE ENGINEER OF RECORD
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-05-04 Cont ID  
Sent By tklarge Date 2016-05-04 Time 13:38 Rev Time 0.00
Received By tklarge Date 2016-05-04 Time 13:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-02-25 Cont ID  
Sent By tklarge Date 2016-02-25 Time 06:40 Rev Time 0.00
Received By tklarge Date 2016-02-25 Time 06:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-12-19 Cont ID  
Sent By tklarge Date 2015-12-19 Time 07:45 Rev Time 0.00
Received By tklarge Date 2015-12-19 Time 07:12 Sent To  
Notes
2015-12-19 07:40:501) THERE ARE PLANS IN THIS PERMIT FOR THE GENERATOR.
 THIS PERMIT IS FOR THE COOLING TOWER. CLARIFY.
 2) THE WATER SUPPLY CONNECTION TO THE TOWER SHALL BE
 EQUIPPED WITH A LEAD FREE REDUCED PRESSURE BACKFLOW
 PREVENTER. SHOW THE SIZE AND LOCATION OF THE BACKFLOW
 PREVENTER ON THE PLANS. SUBMIT MANUF. SPECS ON THE BFP
 DEVICE. PLEASE CONTACT THE CITY OF WEST PALM BEACH
 UTILITIES DEPT. CENTRAL OPERATIONS AT 561-822-2210 FOR
 ADDITIONAL INFORMATION ON THE BACKFLOW PREVENTION
 DEVICE REQUIREMENTS.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2016-05-04 Cont ID  
Sent By shill Date 2016-05-04 Time 13:58 Rev Time 0.00
Received By shill Date 2016-05-04 Time 13:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2016-04-23 Cont ID  
Sent By shill Date 2016-04-23 Time 13:13 Rev Time 0.00
Received By shill Date 2016-04-23 Time 13:05 Sent To  
Notes
2016-04-23 13:21:09****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE PLAN SUBMITTED IS INCOMPLETE. SHEETS E002 AND
 E602 WERE NOT SUBMITTED. REVIEW WAS STOPPED AFTER THE
 2ND MISSING PAGE, PLEASE CHECK ALL PRIOR TO
 RESUBMITTAL.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2016-04-18 Cont ID  
Sent By shill Date 2016-04-18 Time 11:27 Rev Time 0.00
Received By shill Date 2016-04-12 Time 10:44 Sent To  
Notes
2016-04-18 11:40:51****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. SIGNATURE DOCUMENTS SHOULD BE IN THE SAME ORDER AS
 THE DIGITAL SUBMITTAL. PLEASE COLLATE PLANS.
  
 FOR INSTANCE, THE DIGITAL SUBMITTAL STARTS WITH A101,
 C103. THE PAPER SUBMITTAL STARTS WITH UNNUMBERED COVER
 PAGE, G104, C103.
  
 2. SEE FS 481.321. ALL FINAL PLANS, SPECIFICATIONS OR
 REPORTS PREPARED OR ISSUED BY THE REGISTERED LANDSCAPE
 ARCHITECT AND FILED FOR PUBLIC RECORD SHALL BE SIGNED
 BY THE REGISTERED LANDSCAPE ARCHITECT, DATED, AND
 STAMPED OR SEALED ELECTRONICALLY WITH HER OR HIS SEAL.
 THE LANDSCAPE SHEETS ARE NOT SIGNED AND SEALED.
  
 PLEASE CONFIRM THAT ALL SHEETS ARE SIGNED AND SEALED
 PRIOR TO RESUBMITTAL. A COMPLETE REVIEW WILL BE DONE
 AFTER A SET OF PLANS, SIGNED, SEALED AND DATED,
 IDENTICAL TO THE PLANS SUBMITTED VIA PROJECT DOX
 INCLUDING ORDER OF PAGES, IS SUBMITTED.
  
 3. TWO SETS OF PLANS WERE SUBMITTED. ONLY ONE IS
 REQUIRED AS A CONTRACTOR SET WILL NOT BE PROVIDED.
 AFTER APPROVAL OF THE SIGNATURE DOCUMENTS, A DIGITAL
 PLAN WITH CITY STAMPS WILL BE AVAILABLE FOR PRINTING.
  
  
2016-04-13 10:44:22GIVEN TO SKENNEDY

Review Stop Z ZONING
Rev No 2 Status P Date 2016-03-04 Cont ID  
Sent By eschneid Date 2016-03-04 Time 10:47 Rev Time 0.50
Received By eschneid Date 2016-03-04 Time 10:28 Sent To  
Notes
2016-03-04 10:47:16PASSED
  
 LANDSCAPE AND GENERATOR BUILDING REQUIRES SEPARATE
 PERMITS WITH PLANS.

Review Stop Z ZONING
Rev No 1 Status F Date 2015-12-17 Cont ID  
Sent By eschneid Date 2015-12-17 Time 13:56 Rev Time 0.50
Received By eschneid Date 2015-12-17 Time 13:56 Sent To  
Notes
2015-12-17 13:58:13FAILED
  
 1) PROVIDE ELEVATION DRAWINGS FOR THE COOLING TOWER
 ENCLOSURE. THE EAST AND WEST ELEVATIONS SHALL INCLUDE
 THE ATTACHMENT TO THE EXISTING WALL.
  
 2) LANDSCAPE REQUIRES A SEPARATE PERMIT WITH PLANS AND
 COST ESTIMATE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2015-12-10 16:50:4512/10/15