Plan Review Stops For Permit 15110686 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2016-04-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-21 |
Time |
18:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-21 |
Time |
18:20 |
Sent To |
|
|
Notes |
2016-04-21 18:21:24 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR FIXED | | WINDOWS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-14 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-14 |
Time |
16:17 |
Sent To |
|
|
Notes |
2016-04-14 17:16:21 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- PROVIDE HURRICANE SHUTTERS COMPLETE INSTALLATION | | SCHEDULE BEFORE INSTALLATION. | | NOTE: NEED SHUTTERS FOR FIXED WINDOWS AND EXTERIOR | | DOORS WITH GLAZING THAT HAVE NON-IMPACT GLASS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-03-29 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-03-29 |
Time |
11:11 |
Sent To |
|
|
Notes |
2016-03-29 11:13:17 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- PROVIDE HURRICANE SHUTTERS COMPLETE INSTALLATION | | SCHEDULE BEFORE INSTALLATION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-03-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-03-01 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-03-01 |
Time |
13:57 |
Sent To |
|
|
Notes |
2016-03-01 14:00:42 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC-5TH EDITION (2014) | | | | | | ***NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS THAT THE PERMIT WILL BE ISSUED AND CONTRACTOR | | WILL ADDRESS THE COMMENTS BELOW AFTER THE PERMIT IS | | ISSUED AND BEFORE ANY INSPECTIONS. REVISION FEES WILL | | APPLY. CONTRACTOR TO ADVICE IN WRITING IF PROVISO | | OPTION IS PREFERRED. | | | | 1- PROVIDE HURRICANE SHUTTERS COMPLETE INSTALLATION | | SCHEDULE. NO SCHEDULE SUBMITTED THIS TIME. SEC. 107.2.1 | | CITY AMENDMENTS. | | | | 2- ENERGY CALCULATIONS SUBMITTED: | | A) ENGINEER WHO SIGNED AND SEALED THE ENERGY | | CALCULATIONS TO LEGIBLY PROVIDE ALL HIS INFORMATION AS | | REQUIRED BY F.A.C. SEC. 61G15-23.002(2). | | REPEAT COMMENT. NOT ADDRESSED. | | | | B) PROVIDE COMPLETE INFORMATION FOR THE WINDOWS | | OVERHANG DEPTH AND SEPARATION ON PAGE 3 OF 4. SEE | | PLANS. SEC. R101.5.1.1.2 OF FBC-ENERGY CONSERVATION, | | 5TH EDITION (2014). | | REPEAT COMMENT. RESPONSE LETTER STATES THERE IS NOT | | OVERHANG FOR THIS BUILDING. NEVERTHELESS, THERE IS AN | | OVERHANG SEPARATION. THERE IS NOT INFORMATION GIVEN FOR | | THE OVERHANG SEPARATION. SEE PLANS AND REVISE AS | | REQUIRED. | | | | C) PROVIDE COMPLETE INFORMATION IN THE ENERGY | | PERFORMANCE LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 OF | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | REPEAT COMMENT. NEED BUILDER'S SIGNATURE AND DATE. | | | | D) BUNKER ENGINEERING AND CONSTRUCTION IS NOT THE | | BUILDER. REVISE AS REQUIRED. PROVIDE THE CORRECT | | BUILDER'S NAME. SEC. R101.5.1.1.2 OF FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | IMPORTANT: LABEL FOR WINDOWS AND DOORS SHOWING THE | | U-FACTOR AND SHGC FACTOR SPECIFIED ON THE ENERGY | | CALCULATIONS WILL BE REQUIRED WHEN ENERGY CALCULATIONS | | ARE NOT USING THE SOFTWARE DEFAULT FACTOR FOR GLAZING. | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE OLD | | PLANS S WITH REVISED PLANS. SUBMIT OLD DRAWINGS FOR | | REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-12-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-12-22 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-12-22 |
Time |
14:48 |
Sent To |
|
|
Notes |
2015-12-22 15:52:35 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS. | | CODE: FBC-5TH EDITION (2014) | | | | 1- EXISTING ENCLOSED PORCH AREA IS ALTERED TO EXPAND | | THE LIVING AREA. BRING PLANS TO PALM BEACH COUNTY (2300 | | N. JOG RD.) FOR IMPACT FEES ASSESSMENT.. BRING BACK | | COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES | | ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED | | LAND DEVELOPMENT CODE. | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) THERE IS A PERMIT APPLICATION FOR ROOFING | | SUB-PERMIT. PROVIDE PRODUCT APPROVAL FOR ROOF MATERIAL | | TO BE INSTALLED. AND, CLEARLY IDENTIFY APPROVED | | ASSEMBLY TO BE INSTALLED. ALSO, PROVIDE SIGNED AND | | SEALED RAS 117 CALCULATIONS IF SELECTED ASSEMBLY | | DOESN'T MEET THE DESIGN PRESSURES REQUIRED BY SEC. R301 | | OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | B) WINDOW MULLIONS AS SHOWN ON PLANS. | | | | C) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS | | SUBMITTED. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL | | COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR | | LIST THE FLORIDA PRODUCT APPROVAL NUMBER NEXT TO EACH | | SPECIFIED CONNECTOR. | | | | D) OUTSWING ENTRY DOOR AS SHOWN ON PLANS. DRAWINGS | | SUBMITTED WITH FLORIDA PRODUCT APPROVAL FL11136-R3 ARE | | FOR "INSWING" DOORS. NEED DRAWINGS FOR "OUTSWING" DOOR. | | | | E) OUTSWING KITCHEN DOOR THAT MEETS THE DESIGN | | PRESSURES CALCULATED BY THE ENGINEER ON SHEET S.1. | | DESIGN PRESSURES FOR DOOR SUBMITTED WITH FLORIDA | | PRODUCT APPROVAL FL15474-R1 DON'T MEET THE CALCULATED | | DESIGN PRESSURES. PRODUCT APPROVAL NEED TO MEET OR | | EXCEED THE CALCULATED DESIGN PRESSURES. | | | | F) HURRICANE SHUTTERS FOR WINDOWS AND DOORS WITHOUT | | IMPACT RATED GLAZING . AND, PROVIDE COMPLETE | | INSTALLATION SCHEDULE. SEE INSTALLATION SCHEDULE CITY | | SAMPLE OR PROVIDE COMPLETE INSTALLATION SCHEDULE IN ANY | | OTHER FORMAT THAT HAS ALL THE REQUIRED INFORMATION. | | | | 3- ENGINEER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | | | 4- WINDOW AND DOOR SCHEDULE SHOWN ON SHEET S.1 CALL FOR | | WINDOWS AND DOORS WITH IMPACT GLAZING. PRODUCT | | APPROVALS SUBMITTED DON'T HAVE IMPACT GLAZING. REVISE | | AS REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | | 5- ENERGY CALCULATIONS SUBMITTED: | | A) ENGINEER WHO SIGNED AND SEALED THE ENERGY | | CALCULATIONS TO PROVIDE ALL HIS INFORMATION AS REQUIRED | | BY F.A.C. SEC. 61G15-23.002 AND F.S. 471. | | | | B) ENGINEER WHO SIGNED AND SEALED THE ENERGY | | CALCULATIONS TO PROVIDE ORIGINAL SEAL AND SIGNATURE AS | | REQUIRED BY F.A.C. SEC. 61G15-23.002. AND F.S. 471. | | | | C) REVISE ITEM #1. THIS IS NOT NEW CONSTRUCTION. SEC. | | R101.5.1.1.2 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | | | D) ITEM #11: PROVIDE DOCUMENTATION SHOWING HOW | | OBTAINING THE R-8 VALUE FOR DUCT. SEC. R405.4.3 OF | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | NOTE: SEE MECHANICAL NOTES ON MECHANICAL PLAN M.1. | | | | E) CLIMATE ZONE SHOWN ON PAGE 2 OF 4 IS INCORRECT. SEE | | TABLE R301.1 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014) AND REVISE AS REQUIRED. | | | | F) PROVIDE COMPLETE INFORMATION FOR THE WINDOWS | | OVERHANG DEPTH AND SEPARATION. SEC. R101.5.1.1.2 OF | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | G) PROVIDE COMPLETE INFORMATION THE ENERGY PERFORMANCE | | LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 OF FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | IMPORTANT: LABEL FOR WINDOWS AND DOORS SHOWING THE | | U-FACTOR AND SHGC FACTOR SPECIFIED ON THE ENERGY | | CALCULATIONS WILL BE REQUIRED WHEN ENERGY CALCULATIONS | | ARE NOT USING THE SOFTWARE DEFAULT FACTOR FOR GLAZING. | | | | 6- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. REVISE VALUATION AS REQUIRED. INCLUDE THE | | ROOFING SCOPE OF WORK. | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE OLD | | PLANS S WITH REVISED PLANS. SUBMIT OLD DRAWINGS FOR | | REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-04-21 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-04-21 |
Time |
17:51 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-04-21 |
Time |
17:51 |
Sent To |
|
|
Notes |
2016-04-21 17:51:33 | ROUTED TO JULIO GOMEZ |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-02-18 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-02-18 |
Time |
19:00 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-02-18 |
Time |
19:00 |
Sent To |
|
|
Notes |
2016-02-18 19:05:36 | ROUTED TO JULIO GOMEZ |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-12-23 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2015-12-23 |
Time |
15:27 |
Sent To |
|
|
Notes |
2015-12-23 15:32:14 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6700 | | [email protected] | | ALTERNATE CONTACT | | MIKE ALBARRAN | | 561-805-6746 | | [email protected] | | | | | | PROVISO | | | | (C) BOXES AT CEILING-SUSPENDED (PADDLE) FAN OUTLETS. | | OUTLET BOXES OR OUTLET BOX SYSTEMS USED AS THE SOLE | | SUPPORT | | OF A CEILING-SUSPENDED (PADDLE) FAN SHALL BE LISTED, | | SHALL BE | | MARKED BY THEIR MANUFACTURER AS SUITABLE FOR THIS | | PURPOSE, | | AND SHALL NOT SUPPORT CEILING-SUSPENDED (PADDLE) FANS | | THAT | | WEIGH MORE THAN 32 KG (70 LB). FOR OUTLET BOXES OR | | OUTLET BOX | | SYSTEMS DESIGNED TO SUPPORT CEILING-SUSPENDED (PADDLE) | | FANS | | THAT WEIGH MORE THAN 16 KG (35 LB), THE REQUIRED | | MARKING SHALL | | INCLUDE THE MAXIMUM WEIGHT TO BE SUPPORTED. | | | | R404.1 LIGHTING EQUIPMENT (MANDATORY). | | A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY | | INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY | | LAMPS OR A MINIMUM OF 75 PERCENT OF THE PERMANENTLY | | INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH | | EFFICACY LAMPS. | | | | R315.1 CARBON MONOXIDE PROTECTION. | | EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING | | BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS | | ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR | | APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, OR OTHER | | FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE | | AS BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL | | CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET (3048 | | MM) OF EACH ROOM USED FOR SLEEPING PURPOSES. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-04-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-18 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-18 |
Time |
09:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-14 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-14 |
Time |
14:17 |
Sent To |
|
|
Notes |
2016-04-14 17:17:43 | 04/14/16 RECEIVED E-MAIL FROM MECHANICAL ENGINEER | | MICHAEL BASSFORD REGARDING THE EQUIPMENT CALCULATIONS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-03-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-03-02 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-02-18 |
Time |
13:54 |
Sent To |
|
|
Notes |
2016-02-18 13:54:51 | RESUB ROUTED TO MVALDES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-02-18 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-02-18 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-11-17 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2016-03-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-03-29 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-03-29 |
Time |
12:04 |
Sent To |
|
|
Notes |
2016-03-29 12:05:07 | $1101.25 PAID. MU-2016-6730. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2016-03-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-03-02 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-03-02 |
Time |
14:46 |
Sent To |
|
|
Notes |
2016-03-02 14:46:48 | 1- EXISTING ENCLOSED PORCH AREA IS ALTERED TO EXPAND | | THE LIVING AREA. BRING PLANS TO PALM BEACH COUNTY (2300 | | N. JOG RD.) FOR IMPACT FEES ASSESSMENT.. BRING BACK | | COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES | | ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED | | LAND DEVELOPMENT CODE. | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-12-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-12-22 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-12-22 |
Time |
16:53 |
Sent To |
|
|
Notes |
2015-12-22 17:00:49 | 1- EXISTING ENCLOSED PORCH AREA IS ALTERED TO EXPAND | | THE LIVING AREA. BRING PLANS TO PALM BEACH COUNTY (2300 | | N. JOG RD.) FOR IMPACT FEES ASSESSMENT.. BRING BACK | | COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES | | ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED | | LAND DEVELOPMENT CODE. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
P |
Date |
2016-04-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-21 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-21 |
Time |
18:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
F |
Date |
2016-04-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-18 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-18 |
Time |
09:17 |
Sent To |
|
|
Notes |
2016-04-18 09:35:15 | RESIDENTIAL (R3) ALTERATION FIFTH MECHANICAL REVIEW | | CHECKLIST. | | CODE: FBC-5TH EDITION (2014) | | | | 1- PREVIOUS MECHANICAL REVIEWS WERE DENIED BECAUSE THE | | A/C UNIT MAY HAVE BEING OVERSIZED. ENGINEER WAS | | INFORMED VIA PHONE CONVERSATION THAT THE CALCULATIONS | | NEED TO BE DONE BASED ON THE INTERIOR DESIGN | | TEMPERATURES. THE CODE REQUIRES THE A/C SIZING | | CALCULATIONS TO BE DONE BASED ON THE INTERIOR DESIGN | | TEMPERATURES OF 75 DEGREES MINIMUM FOR COOLING AND 72 | | DEGREES MAXIMUM FOR HEATING AS REQUIRED BY SEC. | | R403.6.1 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). THE CALCULATIONS SUBMITTED DON'T SEEM TO COMPLY | | WITH THIS INTERIOR DESIGN TEMPERATURES. PAGE 1 OF 1 OF | | AIR SYSTEM SIZING SUMMARY FOR FAMILY-BEDROOMS AHU-1 | | SHOWS DESIGN SUPPLY TEMP..........58.0 DEGREES. | | THEREFORE, IT DOESN'T SEEM TO COMPLY. REVISE AS | | REQUIRED. | | | | 2- REVISE EQUIPMENT LISTED ON THE MECHANICAL PLAN M.1. | | EQUIPMENT SIZE TO MATCH REVISED EQUIPMENT SIZING | | CALCULATIONS AS REQUIRED BY ITEMS #1 ABOVE. SEC. | | R403.6.1.1 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | | | NOTE: THE DESIGN PROFESSIONAL MAY BE CHARGED FOUR TIMES | | THE PLAN REVIEW FEE IF REVIEW IS DENIED AGAIN AS | | REQUIRED BY FLORIDA STATUTE 553.80(2)(B). | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE OLD | | PLANS S WITH REVISED PLANS. SUBMIT OLD DRAWINGS FOR | | REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
F |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-04-14 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-04-14 |
Time |
14:17 |
Sent To |
|
|
Notes |
2016-04-14 14:19:46 | 04/14/16 RECEIVED AND RESPONDED E-MAIL TO MICHAEL | | BASSFORD P.E. REGARDING THE CALCULATIONS FOR THE | | EQUIPMENT SIZING. | | | | GOOD AFTERNOON MR. BASSFORD, | | DO YOU REMEMBER THAT I TOLD YOU THAT HE CODE REQUIRES | | THE CALCULATIONS TO BE DONE BASED ON THE INTERIOR | | DESIGN TEMPERATURES OF 75 DEGREES MINIMUM FOR COOLING | | AND 72 DEGREES MAXIMUM FOR HEATING AS REQUIRED BY SEC. | | R403.6.1 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). THE CALCULATIONS THAT YOU SUBMITTED DON'T SEEM | | TO COMPLY WITH THIS INTERIOR DESIGN TEMPERATURES. | | | | SINCERELY, | | JULIO GOMEZ | | | | | | ORIGINAL COMMENTS BELOW: | | | | RESIDENTIAL (R3) ALTERATION THIRD MECHANICAL REVIEW | | CHECKLIST. | | CODE: FBC-5TH EDITION (2014) | | | | 1- EQUIPMENT CAPACITY CAN NOT BE MORE THAN 1.15 TIMES | | THE CALCULATED LOAD. SEC. R403.6.1.1 OF FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). CALCULATIONS | | SUBMITTED SHOW A TOTAL CONDITIONING LOAD OF 21454 | | BTU/HR. FRONT PAGE OF CALCULATIONS SUBMITTED CALL FOR | | 2.5 TONS. THIS IS NOT ALLOWED. REVISED AS REQUIRED. | | REPEAT COMMENT. 2.5 TON UNIT IS MORE THAN 1.15 TIMES | | THE CALCULATED LOAD. | | | | 2- REVISE EQUIPMENT LISTED ON THE MECHANICAL PLAN M.1. | | EQUIPMENT SIZE TO MATCH REVISED EQUIPMENT SIZING | | CALCULATIONS AS REQUIRED BY ITEMS #2 ABOVE. SEC. | | R403.6.1.1 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | REPEAT COMMENT. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE OLD | | PLANS S WITH REVISED PLANS. SUBMIT OLD DRAWINGS FOR | | REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2016-04-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-03-29 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-03-29 |
Time |
14:16 |
Sent To |
|
|
Notes |
2016-04-07 15:40:05 | 04/07/16 CALLED MECHANICAL ENGINEER TO GO OVER SIZING | | CALCULATIONS. EQUIPMENT IS OVERSIZED. WAITING FOR | | ENGINEER RESPONSE. JG. | | | | 04/08/16 DISCUSSED EQUIPMENT SIZING WITH ENGINEER. HE | | WILL E-MAIL CALCULATIONS SHOWING THE INTERIOR | | TEMPERATURE DESIGN CRITERIA REQUIRED BY CODE. | | | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2016-03-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-03-29 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-03-29 |
Time |
11:39 |
Sent To |
|
|
Notes |
2016-03-29 11:40:43 | RESIDENTIAL (R3) ALTERATION THIRD MECHANICAL REVIEW | | CHECKLIST. | | CODE: FBC-5TH EDITION (2014) | | | | 1- EQUIPMENT CAPACITY CAN NOT BE MORE THAN 1.15 TIMES | | THE CALCULATED LOAD. SEC. R403.6.1.1 OF FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). CALCULATIONS | | SUBMITTED SHOW A TOTAL CONDITIONING LOAD OF 21454 | | BTU/HR. FRONT PAGE OF CALCULATIONS SUBMITTED CALL FOR | | 2.5 TONS. THIS IS NOT ALLOWED. REVISED AS REQUIRED. | | REPEAT COMMENT. 2.5 TON UNIT IS MORE THAN 1.15 TIMES | | THE CALCULATED LOAD. | | | | 2- REVISE EQUIPMENT LISTED ON THE MECHANICAL PLAN M.1. | | EQUIPMENT SIZE TO MATCH REVISED EQUIPMENT SIZING | | CALCULATIONS AS REQUIRED BY ITEMS #2 ABOVE. SEC. | | R403.6.1.1 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | REPEAT COMMENT. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE OLD | | PLANS S WITH REVISED PLANS. SUBMIT OLD DRAWINGS FOR | | REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-03-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-03-02 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-03-02 |
Time |
14:48 |
Sent To |
|
|
Notes |
2016-03-02 15:11:10 | RESIDENTIAL (R3) ALTERATION SECOND MECHANICAL REVIEW | | CHECKLIST. | | CODE: FBC-5TH EDITION (2014) | | | | 1- ENGINEER WHO SIGNED AND SEALED THE EQUIPMENT SIZING | | CALCULATIONS TO LEGIBLY PROVIDE ALL HIS INFORMATION AS | | REQUIRED BY F.A.C. SEC. 61G15-23.002(2). | | REPEAT COMMENT. | | | | 2- EQUIPMENT CAPACITY CAN NOT BE MORE THAN 1.15 TIMES | | THE CALCULATED LOAD. SEC. R403.6.1.1 OF FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). CALCULATIONS | | SUBMITTED SHOW A TOTAL CONDITIONING LOAD OF 21454 | | BTU/HR. FRONT PAGE OF CALCULATIONS SUBMITTED CALL FOR | | 2.5 TONS. THIS IS NOT ALLOWED. REVISED AS REQUIRED. | | REPEAT COMMENT. 2.5 TON UNIT IS MORE THAN 1.15 TIMES | | THE CALCULATED LOAD. | | | | 3- REVISE EQUIPMENT LISTED ON THE MECHANICAL PLAN M.1. | | EQUIPMENT SIZE TO MATCH REVISED EQUIPMENT SIZING | | CALCULATIONS AS REQUIRED BY ITEMS #2 ABOVE. SEC. | | R403.6.1.1 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | REPEAT COMMENT. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE OLD | | PLANS S WITH REVISED PLANS. SUBMIT OLD DRAWINGS FOR | | REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-12-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-12-23 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-12-23 |
Time |
10:31 |
Sent To |
E |
|
Notes |
2015-12-23 10:36:34 | RESIDENTIAL (R3) ALTERATION MECHANICAL REVIEW COMMENTS. | | CODE: FBC-5TH EDITION (2014) | | | | 1- ENGINEER WHO SIGNED AND SEALED THE EQUIPMENT SIZING | | CALCULATIONS TO PROVIDE ALL HIS INFORMATION AS REQUIRED | | BY F.A.C. SEC. 61G15-23.002 AND F.S. 471. | | | | 2- ENGINEER WHO SIGNED AND SEALED THE EQUIPMENT SIZING | | CALCULATIONS TO PROVIDE ORIGINAL SEAL AND SIGNATURE AS | | REQUIRED BY F.A.C. SEC. 61G15-23.002. AND F.S. 471. | | | | 3- SEC. R403.6.1 OF FBC-ENERGY CONSERVATION, 5TH | | EDITION (2014) DOESN'T ALLOW ANY ADDITIONAL FACTORS | | THAT WILL AFFECT THE A/C EQUIPMENT SIZING. EQUIPMENT | | SIZING CALCULATIONS SUBMITTED ARE DONE BASED ON AN | | OCCUPANT LOAD OF 8 PEOPLE. 8 PEOPLE IS NOT THE TYPICAL | | NUMBER OF PEOPLE FOR A 2 BEDROOM HOUSE. ENERGY | | CALCULATIONS SUBMITTED ARE MORE REALISTIC AND SHOW 4 | | OCCUPANTS. REVISE CALCULATIONS AS REQUIRED. | | | | 4- EQUIPMENT CAPACITY CAN NOT BE MORE THAN 1.15 TIMES | | THE CALCULATED LOAD. SEC. R403.6.1.1 OF FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). CALCULATIONS | | SUBMITTED SHOW A TOTAL CONDITIONING LOAD OF 21441 | | BTU/HR. FRONT PAGE OF CALCULATIONS SUBMITTED CALL FOR | | 2.4 TONS. THIS IS NOT ALLOWED. REVISED AS REQUIRED. | | | | 5- REVISE EQUIPMENT LISTED ON THE MECHANICAL PLAN M.1. | | EQUIPMENT SIZE TO MATCH REVISED EQUIPMENT SIZING | | CALCULATIONS AS REQUIRED BY ITEMS #3 AND #4 ABOVE. SEC. | | R403.6.1.1 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | | | 6- SHEET M.1: TRANSFER DUCT SIZE SPECIFIED FOR BEDROOMS | | #1 AND #2 DOESN'T COMPLY WITH THE BALANCED RETURN AIR | | SEC. M 1602.4 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | REVISE AS REQUIRED. | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE OLD | | PLANS S WITH REVISED PLANS. SUBMIT OLD DRAWINGS FOR | | REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-11-23 |
Time |
04:54 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-11-23 |
Time |
04:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
N |
Date |
2016-03-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-03-02 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-03-02 |
Time |
14:47 |
Sent To |
|
|
Notes |
2016-03-02 14:47:51 | NO ROOFING WORK. ROOFING PERMIT APPLICATION WAS CHANGED | | TO PLUMBING. JG. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2015-12-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-12-22 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-12-22 |
Time |
17:08 |
Sent To |
|
|
Notes |
2015-12-22 17:15:05 | 1- THERE IS A PERMIT APPLICATION FOR ROOFING | | SUB-PERMIT. PROVIDE PRODUCT APPROVAL FOR ROOF MATERIAL. | | CLEARLY IDENTIFY APPROVED ASSEMBLY TO BE INSTALLED. | | AND, PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF | | SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES | | REQUIRED BY SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION | | (2014). |
|
|