Plan Review Details - Permit 15110453
Plan Review Stops For Permit 15110453
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-11-14 Cont ID  
Sent By jwitmer Date 2015-11-14 Time 09:59 Rev Time 0.00
Received By jwitmer Date 2015-11-14 Time 09:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-12-18 Cont ID  
Sent By skennedy Date 2015-12-18 Time 17:03 Rev Time 0.00
Received By skennedy Date 2015-12-15 Time 10:45 Sent To  
Notes
2015-12-18 17:04:10REVIEW BY MALBARRAN.
2015-12-15 11:40:26ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN
 SATISFACTORILY ADDRESSED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-12-01 Cont ID  
Sent By albarran Date 2015-12-01 Time 17:29 Rev Time 0.00
Received By albarran Date 2015-12-01 Time 11:46 Sent To  
Notes
2015-12-01 17:30:31THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
 PG. E0.1
 1. NEC 410.36(B) FRAMING MEMBERS OF SUSPENDED CEILINGS
 USED TO SUPPORT LUMINARIES SHALL BE SECURELY FASTENED
 TO EACH OTHER AND SHALL BE SECURELY ATTACHED TO THE
 BUILDING STRUCTURE. LUMINARIES SHALL BE SECURELY
 FASTENED TO THE FRAMING MEMBERS BY MECHANICAL MEANS.
 PROVIDE A LUMINAIRE SUPPORT DETAIL.
 2. NEC 2011 EDITION IS THE APPLICABLE ELECTRICAL CODE
 GOVERNING THIS INSTALLATION.
 3. FBC-E C405.7.3 IS THE SECTION OF THE FBC ADDRESSING
 VOLTAGE DROP REQUIREMENTS.
 4. NEC 300.21 OPENINGS AROUND ELECTRICAL PENETRATIONS
 INTO OR THROUGH FIRE-RESISTANT-RATED WALLS, PARTITIONS,
 FLOORS OR CEILINGS SHALL BE FIRESTOPPED USING APPROVED
 METHODS TO MAINTAIN THE FIRE RESISTANCE RATING.
 5. NEC 408.4 EVERY CIRCUIT SHALL BE IDENTIFIED AT THE
 PANELS & EVERY PANEL SHALL BE MARKED WITH THE LOCATION
 OF THE POWER SOURCE & DISCONNECT.
 PG. E2.1
 1. EXIT LIGHT REQUIRED HERE.
 2. FBC-E C405.5.2 YOU SHALL SUBMIT A LIGHTING POWER
 DENSITY ALLOWANCE CHART TO INDICATE COMPLIANCE WITH
 ENERGY CONSERVATION CODE REQUIREMENTS.
 PG. E3.1
 1. FIRE ALARM WORK UNDER SEPARATE PERMIT AND SUBMITTAL.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE
 INSERT CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS FOR COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-11-16 Cont ID  
Sent By scaldero Date 2015-11-16 Time 10:11 Rev Time 0.00
Received By scaldero Date 2015-11-16 Time 10:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-18 Cont ID  
Sent By skennedy Date 2015-12-18 Time 17:04 Rev Time 0.00
Received By skennedy Date 2015-12-07 Time 11:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-12-02 Cont ID  
Sent By cpuell Date 2015-12-02 Time 07:56 Rev Time 0.00
Received By cpuell Date 2015-11-12 Time 16:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-12-15 Cont ID  
Sent By ccole Date 2015-12-15 Time 13:40 Rev Time 0.00
Received By ccole Date 2015-12-15 Time 13:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-11-19 Cont ID  
Sent By ccole Date 2015-11-19 Time 14:18 Rev Time 0.00
Received By ccole Date 2015-11-19 Time 14:18 Sent To  
Notes
2015-11-19 14:40:041ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #15110453
 11/19/15
  
 1) REFER TO SECTION 809.2 FBC EXISTING BUILDING CODE:
 809.2 ALTERED EXISTING SYSTEMS.
 IN MECHANICALLY VENTILATED SPACES, EXISTING MECHANICAL
 VENTILATION SYSTEMS THAT ARE ALTERED, RECONFIGURED, OR
 EXTENDED SHALL PROVIDE NOT LESS THAN 5 CUBIC FEET PER
 MINUTE (CFM) (0.0024 M3/S) PER PERSON OF OUTDOOR AIR
 AND NOT LESS THAN 15 CFM (0.0071 M3/S) OF VENTILATION
 AIR PER PERSON; OR NOT LESS THAN THE AMOUNT OF
 VENTILATION AIR DETERMINED BY THE INDOOR AIR QUALITY
 PROCEDURE OF ASHRAE 62. PROVIDE MINIMUM VENTILATION
 CALCULATIONS IN COMPLIANCE WITH TABLE 403.3 FBC-14
 MECHANICAL.
 2) SHEET M2.1: A) PLEASE PROVIDE KEY NOTES TO CLARIFY
 THE SCOPE OF WORK SHOWN IN THE DRAWING. B) PROVIDE AN
 EQUIPMENT SCHEDULE FOR THE VAV BOXES, AND CLARIFY THE
 PRINT SHOWN ON THE BOXES- IT IS ILLEGIBLE. C) PROVIDE
 THE FLEX DUCT SIZES. D) PROVIDE AN AIR DEVICE SCHEDULE.
 3) M2.1: THE PLAN SHOWS RETURN AIR BEING TRANSFERRED
 FROM THE ROOMS TO THE CORRIDOR- SEE SECTION 601.2: AIR
 MOVEMENT IN EGRESS ELEMENTS. CORRIDORS SHALL NOT SERVE
 AS SUPPLY, RETURN, EXHAUST, RELIEF OR VENTILATION AIR
 DUCTS. PLEASE CORRECT THE PLAN.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2015-12-21 Cont ID  
Sent By cpuell Date 2015-12-21 Time 11:59 Rev Time 0.00
Received By cpuell Date 2015-12-21 Time 11:59 Sent To  
Notes
2015-11-12 16:48:43CD & PLANS SUBMITTED WITH APPLICATION FORM, UPLOADED ON
 11/12/15