Plan Review Details - Permit 15110142
Plan Review Stops For Permit 15110142 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-03-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-03-18 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-03-18 |
Time |
08:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-11-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-24 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-11-24 |
Time |
11:25 |
Sent To |
|
|
Notes |
2015-11-24 11:31:02 | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | YOU HAVE NOT PROVIDED THE NECESSARY INFORMATION TO | | PROCESS THIS PERMIT APPLICATION. | | PROVIDE A DETAIL OF THE EXTERIOR WALL, (TYPE OF | | CONSTRUCTION) | | PROVIDE FASTENER SCHEDULE (SIZE, SPACING & EMBEDDMENT) | | DESIGNER OF SUBMITTED DRAWING NEEDS TO SIGN DRAWING. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-11-10 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-10 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-11-10 |
Time |
11:36 |
Sent To |
|
|
Notes |
2015-11-10 11:40:18 | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | PROVIDE DETAIL OF EXT. WALL. PROVIDE FASTENER SCHEDULE | | FOR WALL TYPE. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-03-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-03-18 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-03-17 |
Time |
13:11 |
Sent To |
|
|
Notes |
2016-03-17 13:12:11 | RESUB ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-11-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-24 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-11-19 |
Time |
14:03 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-11-10 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-10 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-11-04 |
Time |
16:18 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-24 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-11-23 |
Time |
15:41 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-11-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-10 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-11-09 |
Time |
11:53 |
Sent To |
B |
|
Notes |
2015-11-09 11:55:42 | 11/9/15 ZONING FAILED | | | | 1. SUBMIT THE DIMENSION OF THE BUILDING WHERE THE SIGN | | WILL BE LOCATED, THE HEIGHT AND THE WIDTH. | | 2, HOW MANY EXISTING SIGNS AND THEIR SQUARE FOOTAGE. |
|
|
|