Plan Review Stops For Permit 15110125 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-02-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-02-11 |
Time |
06:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-02-11 |
Time |
06:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-02-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-02-02 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-02-02 |
Time |
10:04 |
Sent To |
|
|
Notes |
2016-02-02 10:45:08 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15110125 | | ADD: 114 S. OLIVE AVE. | | CONT: HOOD DEPOT | | TEL: 954-570-9860 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | DATE: WED. DEC. 30/2015 | | ACTION: DENIED | | | | NOTICE!!!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA | | STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A | | FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE | | REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO | | CORRECT A CODE VIOLATION. | | | | | | | | 1) COMPLILED. WIND DESIGN CRITERIA ON THE PLANS. | | | | | | 2A)(1) 3RD REQUEST. SEMI COMPLIED. PRECISION ALUMINUM | | PRODUCTS/ A/C STANDS SUBMITTED ENGINEERING FROM FRANK | | BENNARDO NO COVERE SHEETS WERE PROVIDED INDICATING THIS | | IS A FLORIDA APPROVAL OR A MIAMI-DADE NOA. | | | | 2A)(2) SHEET 3 OF 7 SHOWS 3 ROOF TOP CONDENING UNITS | | AND ROOF TOP STAND AND ROOF TOP CURBS INTAKE AND | | EXHAUST FANS PLEASE PROVIDE EITHER A FLORIDA APPROVAL | | OR MIAMI-DADE NOA. . PLEASE SHOW COMPLIANCE WITH: | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | (31)(D) ROOF TOP CURBS, ROOF TOP INTAKE & EXHAUST FANS | | -NO PRODUCT APPROVALS WERE SUBMITTED!!!! | | (31)(G) PRE-ENGINEERED A/C STANDS | | | | 2B) 3RD REQUEST. 107.3.4.1 THOSE PRODUCTS WHICH ARE | | REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 3) 3RD REQUEST.THE ENGINEER OF RECORD (STRUCTURAL) HAS | | NOT REVIEWED THESE PLANS FOR CODE COMPLIANCE, NOR | | AFFIXED THERE SHOP DRAWING STAMPED REVIEWED AND | | APPROVED. FL 61G-15-30.006 (3) THE DELEGATED ENGINEER | | SHALL FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO | | THE ENGINEER OF RECORD FOR REVIEW. | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-12-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-12-30 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-12-30 |
Time |
|
Sent To |
|
|
Notes |
2015-12-30 09:12:34 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15110125 | | ADD: 114 S. OLIVE AVE. | | CONT: HOOD DEPOT | | TEL: 954-570-9860 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | DATE: WED. DEC. 30/2015 | | ACTION: DENIED | | | | NOTICE!!!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA | | STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A | | FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE | | REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO | | CORRECT A CODE VIOLATION. | | | | | | | | 1) 2ND REQUEST. THE (7) MECHANICAL SHEETS SUBMITTED BY | | HOOD DEPOT DO NOT HAVE THE WIND DESIGN CRITERIA ON THE | | PLANS, | | | | 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | STRUCTURE: | | | | 1.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | 1609.3.1. | | | | 1.2. RISK CATEGORY. | | | | 1.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | | 1.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | 1.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | M2). | | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | BUILDING. | | | | 2A) 2ND REQUEST. SHEET 3 OF 7 SHOWS 3 ROOF TOP | | CONDENING UNITS AND ROOF TOP STAND AND ROOF TOP CURBS | | INTAKE AND EXHAUST FANS PLEASE PROVIDE EITHER A FLORIDA | | APPROVAL OR MIAMI-DADE NOA. . PLEASE SHOW COMPLIANCE | | WITH: FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(D) ROOF TOP CURBS, ROOF TOP INTAKE & EXHAUST FANS | | (31)(G) PRE-ENGINEERED A/C STANDS | | | | 2B) 2ND REQUEST. 107.3.4.1 THOSE PRODUCTS WHICH ARE | | REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 3) 2ND REQUEST. SHEET 6 & 7 SHOWS THE AIR COMPRESSOR | | BEING HUNG FROM THE SIDE OF THE THRESHOLD BUILDING. ALL | | THRESHOLD INSPECTIONS ARE TO BE PREFORMED BY THE | | THRESHOLD INSPECTOR. NO INSPECTIONS OF THIS SYSTEM HAS | | OCCURRED. THE SECOND ISSUE IS THE ENGINEER OF RECORD | | (STRUCTURAL) HAS NOT REVIEWED THESE PLANS FOR CODE | | COMPLIANCE, NOR AFFIXED THERE SHOP DRAWING STAMPED | | REVIEWED AND APPROVED. FL 61G-15-30.006 (3) THE | | DELEGATED ENGINEER SHALL FORWARD THE DELEGATED | | ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR | | REVIEW. | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-12-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-12-14 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-12-14 |
Time |
13:40 |
Sent To |
Z |
|
Notes |
2015-12-14 13:55:39 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15110125 | | ADD: 114 S. OLIVE AVE. | | CONT: HOOD DEPOT | | TEL: 954-570-9860 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | DATE: MON. DEC. 21/2015 | | ACTION: DENIED | | | | 1) THE (7) MECHANICAL SHEETS SUBMITTED BY HOOD DEPOT DO | | NOT HAVE THE WIND DESIGN CRITERIA ON THE PLANS, | | | | 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | STRUCTURE: | | | | 1.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | 1609.3.1. | | | | 1.2. RISK CATEGORY. | | | | 1.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | | 1.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | 1.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | M2). | | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | BUILDING. | | | | 2A) SHEET 3 OF 7 SHOWS 3 ROOF TOP CONDENING UNITS AND | | ROOF TOP STAND. PLEASE SHOW COMPLIANCE WITH: FLORIDA | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | THAT WILL REQUIRE PRODUCT APPROVALS: | | (31 (G) PRE-ENGINEERED A/C STANDS | | | | 2B) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | 3) SHEET 5OF 7 SHOWS THE AIR COMPRESSOR BEING HUNG FROM | | THE SIDE OF THE THRESHOLD BUILDING. ALL THRESHOLD | | INSPECTIONS ARE TO BE PREFORMED BY THE THRESHOLD | | INSPECTOR. THE SECOND ISSUE IS THE ENGINEER OF RECORD | | HAS NOT REVIEWED THESE PLANS FOR CODE COMPLIANCE, NOR | | AFFIXED THERE SHOP DRAWING STAMPED REVIEWED AND | | APPROVED. FL 61G-15-30.006 (3) THE DELEGATED ENGINEER | | SHALL FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO | | THE ENGINEER OF RECORD FOR REVIEW. | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
N |
Date |
2016-02-03 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-02-03 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-02-03 |
Time |
13:59 |
Sent To |
I |
|
Notes |
2016-02-03 14:38:03 | HOOD DEPOT IS DEFERRING ALL THE ELECTRICAL COMMENTS AND | | REQUIRED DOCUMENTATION TO AN ELECTRICAL ENGINEER. | | THEREFORE IN AN EFFORT TO RELEASE THIS PERMIT AND NOT | | HOLD IT UP ANY LONGER, I WILL ISSUE THE PERMIT WITHOUT | | ANY ELECTRIC. AN ELECTRICAL SUB PERMIT SHALL BE | | REQUIRED TO ADDRESS ALL OF THE ELECTRICAL COMMENTS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-01-14 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-01-14 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-01-14 |
Time |
12:02 |
Sent To |
Z |
|
Notes |
2016-01-14 14:42:43 | YOUR RESUBMITTAL ADDRESSING THE PREVIOUSLY MENTIONED | | DEFICIENCIES HAS ONCE AGAIN FAILED THE ELECTRICAL | | REVIEW AS INDICATED BELOW. NEW COMMENTS IF ANY PROMPTED | | BY ANOTHER REVIEW, MOST LIKELY DUE TO YOUR FAILURE TO | | SUBMIT A RESPONSE LETTER (NARRATIVE) ADDRESSING THE | | REQUIRED CORRECTIONS WILL BE NUMBERED IN CONTINUATION | | OF ANY PREVIOUS COMMENTS. | | | | 1. THIS TIME THE MASTER PERMIT REFERRED TO ON THE | | APPLICATION IS FOR THE COMMERCIAL REMODEL OF THE BLDG. | | BUT THE KITCHEN HOOD SYSTEM SPECIFIED ON THE MASTER | | PERMIT DIFFERS FROM THE ONE BEING PROPOSED ON THIS | | APPLICATION THEREFORE ALL ELECTRICAL REQUIREMENTS AS | | PREVIOUSLY REQUESTED SHALL BE SUBMITTED FOR REVIEW. | | 2. THE SYSTEM ON THE MASTER PERMIT IS A CAPTIVE AIR AND | | THIS IS A HOOD DEPOT. | | 3. YOU SHALL PROVIDE CIRCUIT DIRECTORY, WIRING DIAGRAM | | AND LOAD CALCS FOR BOTH, THE HOOD FAN MOTORS AND THE | | MUA COOLING SYSTEM. | | 4. PROVIDE SHUNT TRIP BREAKER FOR ALL ELECTRICAL | | EQUIPMENT AND OUTLETS UNDER THE HOOD. | | 5. YOU SHALL PROVIDE A CORRECTED CIRCUIT DIRECTORY FOR | | THE PANELS AFFECTED BY THIS MODIFICATION. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE?SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE?SUBMITTAL FORM, AS WELL AS AN | | INDICATION ON THE PAGE WHERE THE CORRECTION WAS | | PERFORMED. ADDITIONALLY, PLEASE INSERT CORRECTED PAGES | | INTO THE SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED | | SHEETS FOR COMPARISON. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. IF YOU HAVE FURTHER QUESTIONS, | | PLEASE DON?T HESITATE TO CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH.: 561?805?6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-12-11 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-11 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-12-11 |
Time |
09:26 |
Sent To |
B |
|
Notes |
2015-12-11 10:54:16 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | 1. THE MASTER PERMIT REFERRED TO ON THIS APPLICATION IS | | FOR A FIRE SPRINKLER SYSTEM AND HAS NOTHING TO DO WITH | | THE INSTALLATION OF KITCHEN HOODS. THEREFORE A COMPLETE | | ELECTRICAL DRAWING SHALL BE PROVIDED. | | 2. THE FAN SCHEDULE AND CONTROL PANEL INPUT VOLTAGES DO | | NOT MATCH ON THE SUBMITTED DRAWINGS. REVISE DRAWINGS TO | | ADDRESS THIS ISSUE. | | 3. YOU SHALL PROVIDE CIRCUIT DIRECTORY, WIRING DIAGRAM | | AND LOAD CALCS FOR THIS ADDED LOAD. | | 4. PROVIDE SHUNT TRIP BREAKER FOR ALL ELECTRICAL | | EQUIPMENT AND OUTLETS UNDER THE HOOD. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | INSERT CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2016-01-26 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-01-26 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-01-26 |
Time |
14:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-12-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-12-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-12-23 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2015-11-16 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-12-18 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-11-16 |
Time |
11:13 |
Sent To |
M |
|
Notes |
2015-11-16 12:05:32 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1. PLEASE PROVIDE GREATER DETAIL OF THE LOCATION OF THE | | HOOD SYSTEM AS IT APPEARS TO BE IN AN ALLEY. | | | | 2. THE HEIGHT OF THE CLEARENCE FROM THE GROUND, WITHIN | | THE ALLEY, SHALL BE A MINIMUM OF 13'6". | | | | 3. THE LOCATION OF THE 2ND HOOD EXHAUST APPEARS TO BE | | TOO CLOSE TO THE ROOF A/C. PROVIDE GREATER DETAIL. | | | | 4. PROVIDE A FIRE RATED LISTING FOR PENETRATING THE | | EXTERIOR WALL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
P |
Date |
2016-02-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-02-11 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-02-09 |
Time |
09:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-02-10 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-02-10 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-12-18 |
Time |
13:47 |
Sent To |
|
|
Notes |
2016-01-20 12:21:31 | B22 - RESUBMITTED ON 1/19/16 | 2015-12-21 13:47:29 | B22 *COULD NOT LOCATE ORIGINAL SUBMITTAL IN DENIED | | DRAWERS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-12-18 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-12-15 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-11-04 |
Time |
09:09 |
Sent To |
FIRE |
|
Notes |
2015-12-15 18:40:00 | TO SHIRLEY. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2016-02-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-02-10 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-02-10 |
Time |
16:29 |
Sent To |
|
|
Notes |
2016-02-10 16:34:41 | MECHANICAL PROVISOS | | PERMIT #15110125 | | 2/10/16 | | | | 1) A REVISION TO THE PLAN IS REQUIRED FOR GUARD RAILS | | AT ROOF EDGES WHERE SERVICEABLE EQUIPMENT IS WITHIN 10' | | OF THE EDGE. | | 2) PROVIDE AT INSPECTION UL TESTED AND APPROVED | | FIRESTOPPING ASSEMBLIES REQUIRED FOR SEALING THE SUPPLY | | AND EXHAUST DUCT PENETRATIONS THROUGH THE FIRE-RATED | | EXTERIOR WALL BY ALLEYWAY. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2016-02-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-02-01 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-02-01 |
Time |
09:24 |
Sent To |
|
|
Notes |
2016-02-01 09:53:25 | 3RD REVIEW: FBC 2014 MECHANICAL | | PERMIT #15110125 | | 2/1/2016 | | | | 1) THE ENGINEERING AND INSTALLATION DETAILS FOR THE | | SUBMITTED ROOF STAND PRODUCT APPROVAL HAVE BEEN UPDATED | | BY THE CERIFIYING ENGINEER FRANK BENNARDO P.E. PLEASE | | PROVIDE THE 2014 APPROVED FLORIDA PRODUCT APPROVAL FOR | | THE ALUMIMNUM ROOF STAND (INCLUDING THE COVER SHEET) | | WITH AN APPROVAL SIGNATURE ON THE DOCUMENT FROM THE | | ENGINEER OF RECORD ALLEN WEIDER P.E. | | 2) AS PREVIOUSLY NOTED GUARDS ARE REQUIRED FOR THE | | MECHANICAL EQUIPMENT WITHIN 10' OF THE ROOF EDGE. | | PLEASE PROVIDE ENGINEERED PLANS AND SPECIFICATIONS FOR | | REVIEW. | | 3) THE LETTER FROM EMERALD ENGINEERING MUST HAVE AN | | ORIGINAL SIGNATURE AND SEAL- COPIES OF THE ORIGINAL | | LETTER HAVE BEEN SUBMITTED. PLEASE NOTE THAT BY THE | | CONTENT OF THE LETTER, REVISIONS TO THE MAIN PLAN ARE | | REQUIRED BECAUSE OF THE RE-DESIGN OF THE KITCHEN HOOD | | AND EXHAUST SYSTEM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-02-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-12-29 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-12-29 |
Time |
09:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-12-09 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-12-09 |
Time |
06:57 |
Sent To |
|
|
Notes |
2015-12-09 10:04:29 | 1ST REVIEW 2014 MECHANICAL | | PERMIT #15110125 | | 12/9/15 | | | | 1) THE HOOD 1A & 1B SUPPLY FAN AIR INLET (SF-1) SHALL | | NOT BE LOCATED IN AN ALLEY, AND NOT WITHIN THE REQUIRED | | 10' CLEARANCE DISTANCE TO THE ADJACENT PROPERTY LINE- | | REFER TO SECTIONS 508.1 AND 401.4 FBC-14 MECHANICAL. | | 2) SITE SPECIFIC WIND LOAD ENGINEERING IS REQUIRED FOR | | ALL EXTERIOR FAN AND DUCT INSTALLATIONS, INCLUDING THE | | SUPPORT PLATFORMS AND BRACKET ASSEMBLIES IN THE ALLEY- | | SEE SECTION 301.5 AND PROVIDE THE WIND LOAD DESIGN | | CRITERIA ON THE PLANS AND COMPLETE DETAILS. PLEASE | | NOTE: A) SHOP DRAWINGS FOR ALL THE STRUCTURAL | | ASSEMBLIES SHALL BE REVIEWED AND APPROVED BY THE | | ENGINEER OF RECORD AND SUBMITTED TO THE BUILDING | | DEPARTMENT. B)WELDING CERTIFICATIONS SHALL BE ON-SITE | | AT TIME OF INSPECTION. | | 3) PROVIDE UL TESTED AND APPROVED FIRE STOPPING | | ASSEMBLIES ON THE PLAN FOR THE DUCTS PENETRATING THE | | FIRE-RATED EXTERIOR WALL. | | 4) PROVIDE A MECHANICAL ROOF PLAN SHOWING THE LOCATIONS | | OF ALL APPLIANCES AND EQUIPMENT AND THE MINIMUM | | REQUIRED CLEARANCE DISTANCES FOR EXHAUST AND VENT | | OUTLETS, AND MECHANICAL AND GRAVITY AIR INTAKES- REFER | | TO SECTIONS 401.4, 501.3.1, AND 506.3.1. PLEASE NOTE A | | REVISION TO THE ORIGINAL MECHANICAL ROOF PLAN SHEET | | SUBMITTED UNDER THE PERMIT # 13060638 MAY BE REQUIRED | | FOR REVIEW AND FOR PUBLIC RECORD. SEE ALSO SECTION | | 304.11: GUARDS MAY BE REQUIRED FOR EQUIPMENT WITHIN 10' | | OF A ROOF EDGE. | | 5) PROVIDE AIR VELOCITY CALCULATIONS FOR THE EXHAUST | | DUCTS- SECTION 506.3.4. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
N |
Date |
2016-02-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-02-11 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-02-11 |
Time |
08:44 |
Sent To |
|
|
Notes |
2016-02-11 08:52:12 | I SPOKE WITH ANA MARIA APONTE THIS MORNING, THE ONLY | | CHANGE IN PLANS WAS AN ADDTIONAL HORIZONTAL BRACE TO | | THE EXHAUST FAN AND WIND CALCULATIONS FOR ANCHORAGE. | | SHE OK'ED ME WRITING THE SAME APPROVAL SHE WROTE ON | | 01/22/2016. | | PROVISO: SCREENING SHALL BE PROVIDED ALONG THE SOUTH | | SIDE OF THE MECHANICAL EQUIPMENT THE SAME HEIGHT AS THE | | EQUIPMENT. JW 2/11/16 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-01-22 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-01-20 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-01-20 |
Time |
13:50 |
Sent To |
|
|
Notes |
2016-01-20 13:51:32 | PROVISO: SREENING SHALL BE PROVIDED ON THE SOUTH SIDE | | OF THE MECHANICAL EQUIPMENT. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-12-15 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2015-12-15 |
Time |
18:38 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2015-12-15 |
Time |
18:38 |
Sent To |
|
|
Notes |
2015-12-15 18:39:32 | THE MECHANICAL UNIT IS PROJECTING FROM THE ROOF LINE. | | PLEASE PROVIDE INFORMATION TO INDICATE HOW THE UNIT | | WILL BE SCREEN FROM VIEW. MECHANICAL UNIT SHALL BE | | SCREENED WITH AN ECLOSURE AS HIGH AS THE UNIT. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|