Plan Review Stops For Permit 15110034 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-28 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-12-28 |
Time |
12:04 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-11-24 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-11-24 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-11-24 |
Time |
14:07 |
Sent To |
I |
|
Notes |
2015-11-24 14:16:38 | SEE COMMENTS FOR THE PREVIOUS REVIEW WHICH HAVE NOT | | BEEN ADDRESSED. | | PURSUANT TO FL ?553.80, THE 4TH SUBMITTAL FOR A PERMIT | | WHICH REFLECTS FAILURE TO CORRECT A DEFICIENCY | | PREVIOUSLY SPECIFICALLY AND CONSISTENTLY IDENTIFIED ON | | ALL PRIOR SUBMITTALS MUST RESULT IN THE ASSESSMENT OF A | | PENALTY OF 3 TIMES THE PLAN REVIEW FEE IN ADDITION TO | | THE NORMAL FEE |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-11-05 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-11-05 |
Time |
12:35 |
Sent To |
I |
|
Notes |
2015-11-05 12:46:42 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE 2011 EDITION | | OF THE NEC, (NATIONAL ELECTRICAL CODE); THE 5TH EDITION | | OF THE 2014 FBC, (FLORIDA BUILDING CODE) AS APPLICABLE | | AND BELOW ARE THE DEFICIENCIES NOTED. | | | | 1. THESE DRAWINGS BEING THAT THEY ARE FOR THE ACTUAL | | INSTALLATION OF THE HOOD SYSTEM AND THE ASSOCIATED FAN | | MOTORS WILL REQUIRE IN ADDITION TO THE A SITE SPECIFIC | | WIRING DIAGRAM YOU WILL HAVE TO SUBMIT SPECS FOR BOTH, | | THE EXHAUST AND MAKE UP AIR BLOWER MOTORS. | | 2. YOU WILL PROVIDE A CIRCUIT DIRECTORY OF THE PANEL | | WHERE THESE MOTORS ARE BEING SERVED FROM. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | INSERT CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-11-19 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2015-11-19 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2015-11-19 |
Time |
09:48 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-11-03 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-11-05 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2015-11-03 |
Time |
15:15 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-28 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2015-12-28 15:43:50 | 12/28/15 THIS PERMIT PASSED ALL REVIEWS AND IS READY | | FOR ISSUANCE. LORI NOTIFIED VIA EMAIL. SENT TO SMALL | | READY BIN "H". MA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-28 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-12-23 |
Time |
15:03 |
Sent To |
|
|
Notes |
2015-12-28 15:14:10 | 12/28/15 CONTACTED CG TO ADVISE THAT THIS HAD ONCE | | AGAIN FAILED MULTIPLE REVIEWS. GC IS OUT OF TOWN AND | | WILL ADDRESS THIS AFTER THE HOLIDAYS. SENT TO SMALL | | DENIED BIN "P". MA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-11-24 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-11-24 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2015-11-24 14:19:06 | 11/24/15 FAILED THE ELECTRICAL REVIEW. CONTRACTOR | | NOTIFIED VIA EMAIL. SENT TO SMALL DENIED BIN "H". MA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-11-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-11-19 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-11-16 |
Time |
15:36 |
Sent To |
|
|
Notes |
2015-11-16 15:36:10 | RESUB ROUTED TO FIRE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-11-05 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-11-02 |
Time |
14:56 |
Sent To |
|
|
Notes |
2015-11-05 12:47:58 | 11/5/15 FAILED ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | NOTIFIED VIA EMAIL. SENT TO SMALL DENIED BIN "H". MA |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-28 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-12-28 |
Time |
08:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-11-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-11-19 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-11-19 |
Time |
16:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-11-05 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-11-05 |
Time |
09:16 |
Sent To |
|
|
Notes |
2015-11-05 09:37:51 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT #15110034 | | 11/5/2015 | | | | 1) PROVIDE AN AIR VELOCITY CALCULATION FOR THE NEW | | GREASE DUCT- SECTION 506.3.4. | | 2) SHOW COMPLIANCE WITH SECTION 508.1.1 MAKEUP AIR | | TEMPERATURE. | | THE TEMPERATURE DIFFERENTIAL BETWEEN MAKEUP AIR AND THE | | AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10?F | | (6?C) EXCEPT WHERE THE ADDED HEATING AND COOLING LOADS | | OF THE MAKEUP AIR DO NOT EXCEED THE CAPACITY OF THE | | HVAC SYSTEM. | | 3) SHOW COMPLIANCE WITH SECTION 507.9 CLEARANCES FOR | | TYPE I HOOD. | | A TYPE I HOOD SHALL BE INSTALLED WITH A CLEARANCE TO | | COMBUSTIBLES OF NOT LESS THAN 18 INCHES (457 MM). | | EXCEPTION: CLEARANCE SHALL NOT BE REQUIRED FROM GYPSUM | | WALLBOARD OR 1/2-INCH (12.7 MM) OR THICKER CEMENTITIOUS | | WALLBOARD ATTACHED TO NONCOMBUSTIBLE STRUCTURES | | PROVIDED THAT A SMOOTH, CLEANABLE, NONABSORBENT AND | | NONCOMBUSTIBLE MATERIAL IS INSTALLED BETWEEN THE HOOD | | AND THE GYPSUM OR CEMENTITIOUS WALLBOARD OVER AN AREA | | EXTENDING NOT LESS THAN 18 INCHES (457 MM) IN ALL | | DIRECTIONS FROM THE HOOD. | | 4) PROVIDE A SUBMITTAL FOR THE DUCT WRAP WITH A REVIEW | | AND APPROVAL STAMP FROM THE DESIGN PROFESSIONAL OF | | RECORD. | | 5) SHEET 5: PROVIDE THE CLEARANCE DISTANCE MEASURES | | FROM THE GREASE DUCT TERMINATION CAP TO ADJACENT | | BUILDINGS, ADJACENT PROPERTY LINES, AND PARTS OF THE | | SAME OR CONTIGUOUS BUILDING- SECTION 506.3.13.3 | | 6) SITE SPECIFIC WIND LOAD ENGINEERING IS REQUIRED FOR | | TIE DOWN OF THE NEW ROOFTOP EXHAUST AND SUPPLY FANS AND | | CURB ADAPTERS- SECTION 301.15. THE ENGINEER OF RECORD | | SHALL PROVIDE WIND DESIGN CRITERIA, DESIGN PRESSURES, | | AND COMPLETE DETAILS FOR INSTALLATION, INCLUDING | | REVIEWED AND APPROVED SUBMITTALS FOR THE CURB ADAPTERS, | | AND REVIEWED AND APPROVED NOA'S FOR THE FANS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|