Plan Review Details - Permit 15101054
Plan Review Stops For Permit 15101054 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-23 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-23 |
Time |
09:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-11-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-03 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-11-03 |
Time |
13:52 |
Sent To |
|
|
Notes |
2015-11-03 13:54:58 | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | WHEN INSTALLING A HARD FLOORING SURFACE, PROVIDE | | INFORMATION ON THE FLOORING AND SOUND INSULATION TO | | DEMONSTRATE COMPLIANCE WITH THE CRITERIA OF FBC | | SECTIONS BELOW: | | | | FBC 603.1 FLAME SPREAD | | | | FBC 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2015-11-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-21 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-21 |
Time |
10:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-11-03 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-03 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-03 |
Time |
13:54 |
Sent To |
|
|
Notes |
2015-11-03 14:12:54 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | | | FBC 107 PROVIDE MINIMUM INFORMATION AS SPECIFIED BELOW: | | | | PLEASE SPECIFY WHICH MODEL OF THE INSTANT HOT WATER | | HEATER IS PROPOSED AND VERIFY THAT THE EXISTING | | CONDUCTORS AND OCP ARE ADEQUATELY SIZED. THIS MATTER | | CAN BE HANDELED BY AN EMAIL TRANSMITTAL OR YOU MAY | | ELECT TO ALLOW THE ELECTRICIAN OF RECORD TO ADDRESS THE | | MATTER PRIOR TO OR DURING THE INSPECTIOM. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-23 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-21 |
Time |
10:02 |
Sent To |
|
|
Notes |
2015-11-21 10:03:16 | RESPONSE SUBMITTED VIA EMAIL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-11-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-03 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-10-29 |
Time |
15:09 |
Sent To |
P |
|
Notes |
2015-10-30 15:10:13 | GJOHNSON DESK |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-23 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-23 |
Time |
09:09 |
Sent To |
|
|
Notes |
2015-11-23 09:10:01 | A PERMIT IS REQUIRED FOR THE WATWER HEATER REPLACEMENT. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-11-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-03 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-11-02 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
|