Plan Review Stops For Permit 15101000 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-03-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-03-28 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-03-28 |
Time |
17:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-03-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-03-07 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-03-07 |
Time |
17:15 |
Sent To |
P |
|
Notes |
2016-03-07 17:19:17 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | THE IMPACT FEE RECEIPT WAS PROVIDED, BUT THE PLANS ARE | | NOT STAMPED. PROVIDE A PLAN STAMPED BY PALM BEACH | | COUNTY. | | | | MU 2015 024552-0000 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-11-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-11-19 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-11-19 |
Time |
11:43 |
Sent To |
|
|
Notes |
2015-11-19 12:14:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. FBC 107, PROVIDE A GEOTECHNICAL REPORT. BORINGS ARE | | REQUIRED IN BOTH THE HOUSE AND GARAGE AREAS. REPORT IS | | TO BE REVIEWED BY DESIGNER OF RECORD PRIOR TO | | SUBMITTAL. | | | | 2. ENGINEERING PREPARED BY RICHARDSON ENGINEERING LACKS | | A PROJECT ADDRESS/IDENTIFICATION; REVISE, FBC 107. | | REVISE PLAN TO INCLUDE BASIC INFORMATION - ADDRESS, SF | | AREA OF PROPOSED STRUCTURE, NUMBER OF STORIES, HEIGHT, | | FBC 107. | | | | 3. PROVIDE A COPY OF THE SURVEY FOR THIS PROPERTY AS | | WELL AS A SITE PLAN, FBC RES. 302. | | | | 4. FOUNDATION DOES NOT MEET THE REQUIREMENT OF FBC RES. | | 403.1.4, REVISE. | | | | 5. AS THIS IS A FOUNDATION PERMIT, REMOVE ITEMS WHICH | | WILL NOT BE CONSTRUCTED AT THIS TIME. STAIRS ARE SHOWN | | WITH NO INFORMATION AS WELL AS AN "EXISTING LANDING." | | THIS SHOULD NOT BE A PART OF THIS FOUNDATION PERMIT. | | | | 6. PLAN INCLUDES A LINTEL SCHEDULE, NOT CLEAR WHERE | | THIS IS APPLICABLE FOR THE SCOPE OF THIS PERMIT, FBC | | 107. | | | | 7. PLAN SHOWS A "NEW DOOR", NOT CLEAR HOW A DOOR COULD | | BE INSTALLED AT THIS STAGE. | | | | 8. "PROPOSED FRAMING PLAN" NOT CLEAR. THIS PLAN SHOULD | | INCLUDE ONLY STRUCTURAL INFORMATION FOR THE FOUNDATION. | | LANDING APPEARS TO BE AT THE TOP, IS THIS A ROOF | | FRAMING PLAN? SECTION 2 SHOWS AN "EXISTING 2ND FLOOR | | JOIST." PLEASE REMOVE DETAILS WHICH ARE NOT TO BE | | INCLUDED IN THE SCOPE OF THIS PERMIT. | | | | 9. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED, | | 561-233-5025 FOR MORE INFORMATION. | | | | | | | | SECTION 1 SPECIFIES "HOLE FOR STRAPS"; PROVIDE A | | DETAIL. | | FOUNDATION PLAN SHOWS TRIPLE AND DOUBLE 2X8 BEAMS BUT | | DOES NOT SPECIFY MATERIAL OR HOW THESE BEAMS WILL BE | | CONSTRUCTED (FASTENED TOGETHER). | | PLAN HAS NO INFORMATION REGARDING THE STRUCTURE TO BE | | RELOCATED OTHER THAN A REFERENCE TO "MOVED HOUSE." | | SECTIONS 2 AND 3 SHOW 3" COVER, BUT FOOTER STEEL NOT | | SHOWN OR SPECIFIED. | | SECTION 1, FOOTING STEEL SHOWN BUT NOT SPECIFIED. | | | | 6. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. | | CONTACT 561-233-5025 FOR MORE INFORMATION. | | | | 7. ADVISORY ONLY, THIS PERMIT WILL BE ISSUED AT | | CONTRACTOR'S RISK, SEE FBC 105.13 (PHASED | | CONSTRUCTION). | | | | 8. ADVISORY ONLY, SEPARATE PERMITS ARE REQUIRED FOR | | PLUMBING, ELECTRICAL, MECHANICAL. | | | | **NOTE - CALL MICHELLE, PALM BEACH COUNTY IMPACT FEES, | | TO CLARIFY SCOPE OF WORK FOR IMPACT FEE ASSESSMENT - | | 233-5019** | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2016-03-02 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-03-02 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-03-02 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-11-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-19 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-19 |
Time |
17:22 |
Sent To |
|
|
Notes |
2015-11-19 17:23:53 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | NO ELECTRICAL INFORMATION IS PROVIDED. IF APPLICABLE, | | PROVIDE DETAILS TO DEMONSTRATE COMPLIANCE WITH THE | | FOLLOWING: | | | | E3607.1 SYSTEM SERVICE GROUND. | | THE PREMISES WIRING SYSTEM SHALL BE GROUNDED AT THE | | SERVICE WITH A GROUNDING ELECTRODE CONDUCTOR CONNECTED | | TO A GROUNDING ELECTRODE SYSTEM AS REQUIRED BY THIS | | CODE. GROUNDING ELECTRODE CONDUCTORS SHALL BE SIZED IN | | ACCORDANCE WITH TABLE E3603.1. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2016-03-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-03-01 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-03-01 |
Time |
09:51 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2015-11-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-11-19 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-11-02 |
Time |
10:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-03-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-03-28 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-03-23 |
Time |
11:30 |
Sent To |
|
|
Notes |
2016-03-23 11:31:09 | IMPACT FEES ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-03-09 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-03-09 |
Time |
04:20 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-02-29 |
Time |
15:08 |
Sent To |
|
|
Notes |
2016-03-07 17:16:04 | 3/7 TO PLUMBING BOX | | | 2016-02-29 15:08:53 | RESUB ROUTED TO FMITTNER VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-11-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-11-19 |
Time |
17:28 |
Rev Time |
|
Received By |
skennedy |
Date |
2015-10-28 |
Time |
15:02 |
Sent To |
|
|
Notes |
2015-11-19 12:32:10 | 11/19 TO SAK DESK | | | 2015-11-10 14:17:51 | 11/10 TO SH DESK | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2016-03-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-03-28 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-03-28 |
Time |
17:04 |
Sent To |
|
|
Notes |
2016-03-28 17:05:32 | MU-2015-024552-0000 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2016-03-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-03-07 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-03-07 |
Time |
17:14 |
Sent To |
|
|
Notes |
2016-03-07 17:15:25 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | THE IMPACT FEE RECEIPT WAS PROVIDED, BUT THE PLANS ARE | | NOT STAMPED. PROVIDE A PLAN STAMPED BY PALM BEACH | | COUNTY. | | | | MU 2015 024552-0000 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-11-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-11-19 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-11-19 |
Time |
12:14 |
Sent To |
|
|
Notes |
2015-11-19 12:14:42 | 561-233-5025 FOR MORE INFORMATION | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2016-03-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-03-09 |
Time |
04:20 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-09 |
Time |
04:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-11-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-19 |
Time |
17:25 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-19 |
Time |
17:25 |
Sent To |
|
|
Notes |
2015-11-19 17:28:16 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | NO PLUMBING IS SHOWN. IF APPLICABLE PROVIDE PLUMBING | | PLANS PER FBC 107. LOCATION OF FIXTURES AND A SANITARY | | RISER DIAGRAM. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-03-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-03-01 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-03-01 |
Time |
09:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-11-02 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-11-02 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-11-02 |
Time |
10:11 |
Sent To |
B |
|
Notes |
|
|