Plan Review Details - Permit 15100950
Plan Review Stops For Permit 15100950
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-01-19 Cont ID  
Sent By cthroop Date 2016-01-19 Time 13:09 Rev Time 0.00
Received By cthroop Date 2016-01-19 Time 13:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-12-15 Cont ID  
Sent By cthroop Date 2015-12-15 Time 13:52 Rev Time 0.00
Received By cthroop Date 2015-12-15 Time 13:52 Sent To  
Notes
2015-12-15 13:57:00CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER PX3169
 (561) 805-6718
 [email protected]
  
 1ST REVIEW: FBC 2014 5TH ED.
  
 PLANS ALLOW FOR TWO OPTIONS FOR SIGN STRUCTURE.
 DESIGNER HAS NOT INDICATED WHICH OPTION WILL BE USED.
 IF EXISTING POLES/STRUCTURE WILL BE USED, PROVIDE
 DETAILS THAT FOOTING AND POLE IS ADEQUATE TO COMPLY
 WITH THE PROVISIONS OF THIS CODE. IF NEW FOOTINGS AND
 POLES ARE INSTALLED, PROVIDE DETAILS SIGNED BY
 DESIGNER.
  
 VALUATION ? THE VALUE OF THE WORK APPEARS LOW EVEN FOR
 A FACE CHANGE. VERIFY THE VALUE, PARTICULARLY IF A NEW
 STRUCTURE IS PROPOSED.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-23 Cont ID  
Sent By skennedy Date 2015-11-23 Time 07:52 Rev Time 0.00
Received By skennedy Date 2015-11-23 Time 07:52 Sent To  
Notes
2015-11-23 07:52:481ST REVIEW: FBC 2014 5TH ED.
  
 FBC 107 - PROVIDE MINIMUM INFORMATION.
  
 THE PLAN GIVES OPTIONS TO USE THE EXISTING STRUCTURE OR
 PROVIDE A NEW ONE. PLEASE SPECIFY THE SCOPE OF MORE.
 WHICH IS IT?
  
 PROVIDE DETAILS AS TO THE USE OF THE EXISTING FOOTING
 AND POLE AS ADEQUATE IF THAT IS YOUR CHOICE OR PROVIDE
 INFORMATION FOR A NEW SIGN STRUCTURE IF THAT IS YOUR
 CHOICE.
  
 VALUATION - THE VALUE OF THE WORK APPEARS LOW EVEN FOPR
 A FACE CHANGE, VERIFY HE VALUE, PARTICULARLY IF A NEW
 STRUCTURE IS PROPOSED.
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2015-12-15 Cont ID  
Sent By cthroop Date 2015-12-15 Time 13:52 Rev Time 0.00
Received By cthroop Date 2015-12-15 Time 13:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-11-23 Cont ID  
Sent By skennedy Date 2015-11-23 Time 07:52 Rev Time 0.00
Received By skennedy Date 2015-11-23 Time 07:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-01-19 Cont ID  
Sent By cthroop Date 2016-01-19 Time 13:08 Rev Time 0.00
Received By cthroop Date 2016-01-14 Time 11:24 Sent To  
Notes
2016-01-19 11:24:57RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-15 Cont ID  
Sent By cthroop Date 2015-12-15 Time 13:52 Rev Time 0.00
Received By cthroop Date 2015-12-10 Time 09:15 Sent To  
Notes
2015-12-11 09:15:31RESUB ROUTED TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-23 Cont ID  
Sent By skennedy Date 2015-11-23 Time 07:53 Rev Time 0.00
Received By skennedy Date 2015-10-27 Time 15:58 Sent To  
Notes
2015-11-02 17:43:2711/2 TO SAK DESK
  
2015-10-27 16:01:43ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2015-12-14 Cont ID  
Sent By sgraham Date 2015-12-14 Time 14:55 Rev Time 0.00
Received By sgraham Date 2015-12-14 Time 14:55 Sent To AD
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-10-28 Cont ID  
Sent By sgraham Date 2015-10-28 Time 15:15 Rev Time 0.00
Received By sgraham Date 2015-11-23 Time 12:44 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved