Plan Review Stops For Permit 15100811 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-17 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-17 |
Time |
08:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-12-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-07 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-07 |
Time |
07:43 |
Sent To |
|
|
Notes |
2015-12-07 13:27:34 | PLAN | | REVIEW COMMENTS | | 2ND REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE POOL IS LOCATED IN AN AREA THAT IS KNOWN TO | | CONTAIN QUESTIONABLE SOILS. SUBMIT TWO COPIES OF A SOIL | | TEST IN COMPLIANCE WITH FBC-R401.4 FOR THE PROPOSED | | POOL. | | | | 2) THE POOL IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (FLOOD ZONE A5). THE POOL EQUIPMENT IS REQUIRED TO BE | | LOCATED AT OR ABOVE A BASE FLOOD ELEVATION OF 7.5' | | NGVD. FBC-R322 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-10-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-10-28 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-10-28 |
Time |
14:21 |
Sent To |
|
|
Notes |
2015-10-28 15:02:32 | SEE REVIEW COMMENTS FROM ZONING REQUESTING A SURVEY. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-17 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-17 |
Time |
08:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-12-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-07 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-07 |
Time |
07:51 |
Sent To |
|
|
Notes |
2015-12-07 13:12:29 | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY ELECTRIC | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE ELECTRICAL LOAD CALCULATIONS AND PANEL SCHEDULE | | DO NOT LIST THE JANDY JE 3000 HEAT PUMP ELECTRIC POOL | | HEATER ($127,000 BTU). THE SIZE OF THE EXISTING PANEL | | IS NOT SPECIFIED. FBC 107.2.1 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-10-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-10-28 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-10-28 |
Time |
14:21 |
Sent To |
|
|
Notes |
2015-10-28 15:00:54 | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY ELECTRIC | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT TWO SETS OF ELECTRICAL LOAD CALCULATIONS AND | | A PANEL SCHEDULE TO SHOW THAT THE EXISTING ELECTRICAL | | SYSTEM IS ADEQUATE TO HANDLE THE ADDITIONAL LOADS. FBC | | 107.2.1 | | | | NOTE: THE ELECTRICAL REQUIREMENTS FOR PRIVATE SWIMMING | | POOLS INSTALLED AT ONE AND TWO FAMILY DWELLINGS OR | | TOWNHOUSES ARE IN CHAPTER 42 OF THE FBC FIFTH EDITION | | (2014) RESIDENTIAL. ON FUTURE SUBMITTALS, UPDATE THE | | PLANS TO CITE THE APPROPRIATE CODE SECTIONS FROM THE | | 2014 FBC. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
N |
Date |
2015-12-18 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-12-18 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-12-18 |
Time |
08:13 |
Sent To |
|
|
Notes |
2015-12-18 08:21:18 | THE GAS PERMIT HAS BEEN SEPARATED FROM THESE DOCUMENTS | | AND HAS BEEN REVIEWED AND REJECTED UNDER APPLICATION | | #15100819. | | TKL. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2015-12-06 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-12-06 |
Time |
5:51 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-12-06 |
Time |
05:04 |
Sent To |
|
|
Notes |
2015-12-06 05:29:36 | 1) THE GAS HEATER SHALL HAVE A MINIMUM THERMAL | | EFFICIENCY OF 82%.THE SUBMITTED SPECIFICATION SHEET | | DOES NOT SHOW THIS REQUIREMENT. SUBMIT POOL HEATER | | SPECS THAT SHOW COMPLIANCE. 2014 FBC-ENERGY CODE | | SEC.R403.9.1.1.2ND REQUEST | | 2) GAS POOL HEATERS SHALL NOT HAVE CONTINUOUSLY BURNING | | PILOT LIGHTS.2014 FBC-ENERGY CODE SEC.R403.9.1.1. | | SUBMIT SPECIFICATIONS THAT SHOW COMPLIANCE. 2ND | | REQUEST. | | 3) IDENTIFY THE MODEL OF THE POOL HEATER TO BE | | INSTALLED ON THE MANUF. SPECIFICATIONS.2ND REQUEST | | 4) THE SUBMITTED GAS DRAWING SHOWS 3 HEATERS: 2 | | "HEATERS" @ 400,000 BTU'S AND ONE POOL HEATER AT | | 250,000 BTU'S. WHAT ARE THE TWO "HEATERS"? IF THEY ARE | | POOL HEATERS IDENTIFY THEM AS SUCH AND WHY ARE THERE 3 | | HEATERS WHEN THE POOL PLANS CALL OUT ONE. | | 5) THE GAS PLAN DOES NOT SHOW THE RANGE AND BBQ AS | | EXISTING IF THAT IS WHAT THEY ARE. IDENTIFY ON THE PLAN | | IF THEY ARE NEW AND TO BE INSTALLED UNDER THIS GAS | | PERMIT OR IF THEY ARE EXISTING. WPB AMEND. TO FBC SEC. | | 107.2.1. | | 6) IDENTIFY THE BBQ OUTLET ON THE GAS RISER. WPB AMEND. | | TO FBC SEC. 107.2.1. | | 7) SHOW THE BTU LOAD OF EACH APPLIANCE AT THE GAS | | OUTLET. THE PROPER SIZING FOR THE INDIVIDUAL SECTIONS | | OF PIPE CANNOT BE DETERMINED TO BE COMPLIANT WITHOUT | | THIS INFORMATION.WPB AMEND. TO FBC SEC. 107.2.1. | | 8) THE SUBMITTED GAS PLAN SHOWS ONE POOL HEATER AS | | 250,000 BTU'S AND TWO OTHER " HEATERS " AS 400,000 | | BTU'S BUT THE POOL PLANS CALL OUT A 125,000 BTU GAS | | POOL HEATER AND ONE HEAT PUMP. AT THIS POINT, I HAVE | | ABSOLUTELY NO IDEA WHAT IS BEING INSTALLED ON THIS | | POOL. THE CONTRACTOR NEEDS TO COME IN AND STRAIGHTEN | | OUT THIS CONVOLUTED SUBMISSION AND SUBMIT TWO COPIES OF | | DOCUMENTS THAT SATISFY THE GAS REVIEW COMMENTS. | | 9) ALSO, SEE APPLICATION #15100819. | | | | ** NOTE: DO NOT SUBMIT CORRECTIONS FOR THE GAS UNLESS | | ALL ITEMS ARE CORRECTED. | | | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2015-10-27 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-10-27 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-10-27 |
Time |
10:48 |
Sent To |
|
|
Notes |
2015-10-27 10:54:15 | 1) THE GAS HEATER SHALL HAVE A MINIMUM THERMAL | | EFFICIENCY OF 82%.THE SUBMITTED SPECIFICATION SHEET | | DOES NOT SHOW THIS REQUIREMENT. SUBMIT POOL HEATER | | SPECS THAT SHOW COMPLIANCE. 2014 FBC-ENERGY CODE | | SEC.R403.9.1.1. | | 2) GAS POOL HEATERS SHALL NOT HAVE CONTINUOUSLY BURNING | | PILOT LIGHTS.2014 FBC-ENERGY CODE SEC.R403.9.1.1. | | SUBMIT SPECIFICATIONS THAT SHOW COMPLIANCE. | | 3) IDENTIFY THE MODEL OF THE POOL HEATER TO BE | | INSTALLED ON THE MANUF. SPECIFICATIONS. | | 4) SIZE ALL SECTIONS OF THE GAS PIPING DIAGRAM AND | | CLEARLY SHOW THE TYPE OF PIPE BEING INSTALLED.WPB | | AMEND. TO FBC SEC. 107.2.1. | | 5) THE GAS DRAWING IS ILLEGIBLE.SUBMIT A GAS RISER THAT | | IS CLEAR IN DETAIL AND SHOWS ALL PIPE SIZES, PIPE | | MATERIALS AND BTU LOAD OF EACH APPLIANCE. WPB AMEND. TO | | FBC SEC. 107.2.1. | | SEE ALSO APPLICATION #15100819 | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-17 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-10 |
Time |
09:16 |
Sent To |
|
|
Notes |
2015-12-11 09:16:55 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-12-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-07 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-02 |
Time |
11:12 |
Sent To |
|
|
Notes |
2015-12-03 11:12:41 | RESUB ROTUED TO SGRAHAM |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-10-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-10-28 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-10-22 |
Time |
15:07 |
Sent To |
|
|
Notes |
2015-10-22 15:07:48 | ROUTED TO ZONING |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-12-06 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-12-06 |
Time |
05:04 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-12-06 |
Time |
04:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2015-10-27 |
Time |
|
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-10-27 |
Time |
06:24 |
Sent To |
|
|
Notes |
2015-10-27 10:40:58 | 1) SUBMIT A SET OF POOL PLANS THAT ARE CLEAR IN DETAIL | | AND REFLECT THE SCOPE OF WORK TO BE DONE. THE PIPING | | PLANS HAVE ITEMS CROSSED OFF, PORTIONS ARE DIFFICULT TO | | READ,AND I CANNOT DETERMINE WHAT IS AND WHAT IS NOT | | BEING INSTALLED. SUBMIT PLANS WITH CLEAN PIPING | | DRAWINGS WTHOUT ITEMS CROSSED OFF THAT CLEARLY SHOW | | WHAT IS BEING INSTALLED. | | 2) THE PIPING DIAGRAM FOR THE SPA SHOWS 2 MAIN DRAINS | | AND THE PLAN VIEW SHOWS ONE. CLARIFY.THE SPA DETAIL ON | | SHEET 1 SHOWS 2-8" MAIN DRAINS ALSO. | | 3) SKIMMER & VAC DETAIL REFERS TO 2010 FBC. THE CODE IN | | EFFECT IS THE 2014 FBC-RESIDENTIAL. | | 4) THE PIPING SCHEMATIC SHOWS THE SUCTION PIPING FOR | | THE SPA AS 2" BUT THE PLAN VIEW SHOWS 3". THERE IS ALSO | | A NOTE ON THE PLANS THAT STATES ALL SUCTION PIPING TO | | BE 2". CLARIFY. | | 5) THERE IS A NOTE ON THE PLANS THAT STATES THE MAXIMUM | | SUCTION PIPE VELOCITY IS SIX FEET PER SECOND BUT THE | | APSP/ANSI-7 WORKSHEET NOTES THE SUCTION VELOCITY AS 8 | | FPS. CLARIFY. | | 6) SHOW THE PIPE SIZE FOR THE DECK JETS. WPB AMEND. TO | | FBC SEC. 107.2.1. | | 7) SHT. HP-1 IS ILLEGIBLE.SUBMIT A PLAN THAT IS CLEAR | | IN DETAIL AND REFLECTS WHAT IS TO BE DONE. WPB AMEND. | | TO FBC SEC. 107.2.1. | | | | PLEASE DO NOT SUBMIT A PLAN OF THIS QUALITY IN THE | | FUTURE. PLANS THAT SHOW ITEMS CROSSED OFF AND ARE NOT | | CLEAR IN THE SCOPE OF WORK WILL BE REJECTED. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-12-03 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-12-03 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-12-03 |
Time |
15:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-10-23 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-10-23 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-10-23 |
Time |
09:47 |
Sent To |
AD |
|
Notes |
2015-10-23 09:49:16 | 10/23/15 ZONING FAILED | | | | 1. SUBMIT TWO COPIES OF A UP TO DATE CERTIFIED SURVEY | | SHOWING THE LOCATION OF THE POOL |
|
|