Plan Review Details - Permit 15100811
Plan Review Stops For Permit 15100811
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-12-17 Cont ID  
Sent By rmcdouga Date 2015-12-17 Time 08:57 Rev Time 0.00
Received By rmcdouga Date 2015-12-17 Time 08:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-12-07 Cont ID  
Sent By rmcdouga Date 2015-12-07 Time 07:43 Rev Time 0.00
Received By rmcdouga Date 2015-12-07 Time 07:43 Sent To  
Notes
2015-12-07 13:27:34PLAN
 REVIEW COMMENTS
 2ND REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
  
 1) THE POOL IS LOCATED IN AN AREA THAT IS KNOWN TO
 CONTAIN QUESTIONABLE SOILS. SUBMIT TWO COPIES OF A SOIL
 TEST IN COMPLIANCE WITH FBC-R401.4 FOR THE PROPOSED
 POOL.
  
 2) THE POOL IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (FLOOD ZONE A5). THE POOL EQUIPMENT IS REQUIRED TO BE
 LOCATED AT OR ABOVE A BASE FLOOD ELEVATION OF 7.5'
 NGVD. FBC-R322

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-10-28 Cont ID  
Sent By rmcdouga Date 2015-10-28 Time 15:00 Rev Time 0.00
Received By rmcdouga Date 2015-10-28 Time 14:21 Sent To  
Notes
2015-10-28 15:02:32SEE REVIEW COMMENTS FROM ZONING REQUESTING A SURVEY.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-12-17 Cont ID  
Sent By rmcdouga Date 2015-12-17 Time 09:04 Rev Time 0.00
Received By rmcdouga Date 2015-12-17 Time 08:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-12-07 Cont ID  
Sent By rmcdouga Date 2015-12-07 Time 08:11 Rev Time 0.00
Received By rmcdouga Date 2015-12-07 Time 07:51 Sent To  
Notes
2015-12-07 13:12:292ND REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRIC
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE ELECTRICAL LOAD CALCULATIONS AND PANEL SCHEDULE
 DO NOT LIST THE JANDY JE 3000 HEAT PUMP ELECTRIC POOL
 HEATER ($127,000 BTU). THE SIZE OF THE EXISTING PANEL
 IS NOT SPECIFIED. FBC 107.2.1
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-10-28 Cont ID  
Sent By rmcdouga Date 2015-10-28 Time 14:21 Rev Time 0.00
Received By rmcdouga Date 2015-10-28 Time 14:21 Sent To  
Notes
2015-10-28 15:00:541ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRIC
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT TWO SETS OF ELECTRICAL LOAD CALCULATIONS AND
 A PANEL SCHEDULE TO SHOW THAT THE EXISTING ELECTRICAL
 SYSTEM IS ADEQUATE TO HANDLE THE ADDITIONAL LOADS. FBC
 107.2.1
  
 NOTE: THE ELECTRICAL REQUIREMENTS FOR PRIVATE SWIMMING
 POOLS INSTALLED AT ONE AND TWO FAMILY DWELLINGS OR
 TOWNHOUSES ARE IN CHAPTER 42 OF THE FBC FIFTH EDITION
 (2014) RESIDENTIAL. ON FUTURE SUBMITTALS, UPDATE THE
 PLANS TO CITE THE APPROPRIATE CODE SECTIONS FROM THE
 2014 FBC.

Review Stop G GAS REVIEW
Rev No 3 Status N Date 2015-12-18 Cont ID  
Sent By tklarge Date 2015-12-18 Time 08:13 Rev Time 0.00
Received By tklarge Date 2015-12-18 Time 08:13 Sent To  
Notes
2015-12-18 08:21:18THE GAS PERMIT HAS BEEN SEPARATED FROM THESE DOCUMENTS
 AND HAS BEEN REVIEWED AND REJECTED UNDER APPLICATION
 #15100819.
 TKL.

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2015-12-06 Cont ID  
Sent By tklarge Date 2015-12-06 Time 5:51 Rev Time 0.00
Received By tklarge Date 2015-12-06 Time 05:04 Sent To  
Notes
2015-12-06 05:29:361) THE GAS HEATER SHALL HAVE A MINIMUM THERMAL
 EFFICIENCY OF 82%.THE SUBMITTED SPECIFICATION SHEET
 DOES NOT SHOW THIS REQUIREMENT. SUBMIT POOL HEATER
 SPECS THAT SHOW COMPLIANCE. 2014 FBC-ENERGY CODE
 SEC.R403.9.1.1.2ND REQUEST
 2) GAS POOL HEATERS SHALL NOT HAVE CONTINUOUSLY BURNING
 PILOT LIGHTS.2014 FBC-ENERGY CODE SEC.R403.9.1.1.
 SUBMIT SPECIFICATIONS THAT SHOW COMPLIANCE. 2ND
 REQUEST.
 3) IDENTIFY THE MODEL OF THE POOL HEATER TO BE
 INSTALLED ON THE MANUF. SPECIFICATIONS.2ND REQUEST
 4) THE SUBMITTED GAS DRAWING SHOWS 3 HEATERS: 2
 "HEATERS" @ 400,000 BTU'S AND ONE POOL HEATER AT
 250,000 BTU'S. WHAT ARE THE TWO "HEATERS"? IF THEY ARE
 POOL HEATERS IDENTIFY THEM AS SUCH AND WHY ARE THERE 3
 HEATERS WHEN THE POOL PLANS CALL OUT ONE.
 5) THE GAS PLAN DOES NOT SHOW THE RANGE AND BBQ AS
 EXISTING IF THAT IS WHAT THEY ARE. IDENTIFY ON THE PLAN
 IF THEY ARE NEW AND TO BE INSTALLED UNDER THIS GAS
 PERMIT OR IF THEY ARE EXISTING. WPB AMEND. TO FBC SEC.
 107.2.1.
 6) IDENTIFY THE BBQ OUTLET ON THE GAS RISER. WPB AMEND.
 TO FBC SEC. 107.2.1.
 7) SHOW THE BTU LOAD OF EACH APPLIANCE AT THE GAS
 OUTLET. THE PROPER SIZING FOR THE INDIVIDUAL SECTIONS
 OF PIPE CANNOT BE DETERMINED TO BE COMPLIANT WITHOUT
 THIS INFORMATION.WPB AMEND. TO FBC SEC. 107.2.1.
 8) THE SUBMITTED GAS PLAN SHOWS ONE POOL HEATER AS
 250,000 BTU'S AND TWO OTHER " HEATERS " AS 400,000
 BTU'S BUT THE POOL PLANS CALL OUT A 125,000 BTU GAS
 POOL HEATER AND ONE HEAT PUMP. AT THIS POINT, I HAVE
 ABSOLUTELY NO IDEA WHAT IS BEING INSTALLED ON THIS
 POOL. THE CONTRACTOR NEEDS TO COME IN AND STRAIGHTEN
 OUT THIS CONVOLUTED SUBMISSION AND SUBMIT TWO COPIES OF
 DOCUMENTS THAT SATISFY THE GAS REVIEW COMMENTS.
 9) ALSO, SEE APPLICATION #15100819.
  
 ** NOTE: DO NOT SUBMIT CORRECTIONS FOR THE GAS UNLESS
 ALL ITEMS ARE CORRECTED.
  
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2015-10-27 Cont ID  
Sent By tklarge Date 2015-10-27 Time 10:59 Rev Time 0.00
Received By tklarge Date 2015-10-27 Time 10:48 Sent To  
Notes
2015-10-27 10:54:151) THE GAS HEATER SHALL HAVE A MINIMUM THERMAL
 EFFICIENCY OF 82%.THE SUBMITTED SPECIFICATION SHEET
 DOES NOT SHOW THIS REQUIREMENT. SUBMIT POOL HEATER
 SPECS THAT SHOW COMPLIANCE. 2014 FBC-ENERGY CODE
 SEC.R403.9.1.1.
 2) GAS POOL HEATERS SHALL NOT HAVE CONTINUOUSLY BURNING
 PILOT LIGHTS.2014 FBC-ENERGY CODE SEC.R403.9.1.1.
 SUBMIT SPECIFICATIONS THAT SHOW COMPLIANCE.
 3) IDENTIFY THE MODEL OF THE POOL HEATER TO BE
 INSTALLED ON THE MANUF. SPECIFICATIONS.
 4) SIZE ALL SECTIONS OF THE GAS PIPING DIAGRAM AND
 CLEARLY SHOW THE TYPE OF PIPE BEING INSTALLED.WPB
 AMEND. TO FBC SEC. 107.2.1.
 5) THE GAS DRAWING IS ILLEGIBLE.SUBMIT A GAS RISER THAT
 IS CLEAR IN DETAIL AND SHOWS ALL PIPE SIZES, PIPE
 MATERIALS AND BTU LOAD OF EACH APPLIANCE. WPB AMEND. TO
 FBC SEC. 107.2.1.
 SEE ALSO APPLICATION #15100819
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-12-17 Cont ID  
Sent By rmcdouga Date 2015-12-17 Time 09:04 Rev Time 0.00
Received By rmcdouga Date 2015-12-10 Time 09:16 Sent To  
Notes
2015-12-11 09:16:55RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-07 Cont ID  
Sent By rmcdouga Date 2015-12-07 Time 08:11 Rev Time 0.00
Received By rmcdouga Date 2015-12-02 Time 11:12 Sent To  
Notes
2015-12-03 11:12:41RESUB ROTUED TO SGRAHAM

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-10-28 Cont ID  
Sent By rmcdouga Date 2015-10-28 Time 15:02 Rev Time 0.00
Received By rmcdouga Date 2015-10-22 Time 15:07 Sent To  
Notes
2015-10-22 15:07:48ROUTED TO ZONING

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-12-06 Cont ID  
Sent By tklarge Date 2015-12-06 Time 05:04 Rev Time 0.00
Received By tklarge Date 2015-12-06 Time 04:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2015-10-27 Time   Rev Time 0.00
Received By tklarge Date 2015-10-27 Time 06:24 Sent To  
Notes
2015-10-27 10:40:581) SUBMIT A SET OF POOL PLANS THAT ARE CLEAR IN DETAIL
 AND REFLECT THE SCOPE OF WORK TO BE DONE. THE PIPING
 PLANS HAVE ITEMS CROSSED OFF, PORTIONS ARE DIFFICULT TO
 READ,AND I CANNOT DETERMINE WHAT IS AND WHAT IS NOT
 BEING INSTALLED. SUBMIT PLANS WITH CLEAN PIPING
 DRAWINGS WTHOUT ITEMS CROSSED OFF THAT CLEARLY SHOW
 WHAT IS BEING INSTALLED.
 2) THE PIPING DIAGRAM FOR THE SPA SHOWS 2 MAIN DRAINS
 AND THE PLAN VIEW SHOWS ONE. CLARIFY.THE SPA DETAIL ON
 SHEET 1 SHOWS 2-8" MAIN DRAINS ALSO.
 3) SKIMMER & VAC DETAIL REFERS TO 2010 FBC. THE CODE IN
 EFFECT IS THE 2014 FBC-RESIDENTIAL.
 4) THE PIPING SCHEMATIC SHOWS THE SUCTION PIPING FOR
 THE SPA AS 2" BUT THE PLAN VIEW SHOWS 3". THERE IS ALSO
 A NOTE ON THE PLANS THAT STATES ALL SUCTION PIPING TO
 BE 2". CLARIFY.
 5) THERE IS A NOTE ON THE PLANS THAT STATES THE MAXIMUM
 SUCTION PIPE VELOCITY IS SIX FEET PER SECOND BUT THE
 APSP/ANSI-7 WORKSHEET NOTES THE SUCTION VELOCITY AS 8
 FPS. CLARIFY.
 6) SHOW THE PIPE SIZE FOR THE DECK JETS. WPB AMEND. TO
 FBC SEC. 107.2.1.
 7) SHT. HP-1 IS ILLEGIBLE.SUBMIT A PLAN THAT IS CLEAR
 IN DETAIL AND REFLECTS WHAT IS TO BE DONE. WPB AMEND.
 TO FBC SEC. 107.2.1.
  
 PLEASE DO NOT SUBMIT A PLAN OF THIS QUALITY IN THE
 FUTURE. PLANS THAT SHOW ITEMS CROSSED OFF AND ARE NOT
 CLEAR IN THE SCOPE OF WORK WILL BE REJECTED.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2015-12-03 Cont ID  
Sent By sgraham Date 2015-12-03 Time 15:21 Rev Time 0.00
Received By sgraham Date 2015-12-03 Time 15:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-10-23 Cont ID  
Sent By sgraham Date 2015-10-23 Time 09:48 Rev Time 0.00
Received By sgraham Date 2015-10-23 Time 09:47 Sent To AD
Notes
2015-10-23 09:49:1610/23/15 ZONING FAILED
  
 1. SUBMIT TWO COPIES OF A UP TO DATE CERTIFIED SURVEY
 SHOWING THE LOCATION OF THE POOL