|
 |
 |
 |
 |
 |
Plan Review Details - Permit 15100683
Plan Review Stops For Permit 15100683 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-01-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-01-08 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-01-08 |
Time |
11:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-11-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-03 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-11-03 |
Time |
16:00 |
Sent To |
E |
|
Notes |
2015-11-04 09:14:49 | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | AND THE PROPOSED FINISHED GRADES AND, AS APPLICABLE, | | FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN FLOOD | | ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN | | ACCURATE BOUNDARY LINE SURVEY. | | | | 107.2.5.1 DESIGN FLOOD ELEVATIONS. WHERE DESIGN FLOOD | | ELEVATIONS ARE NOT SPECIFIED, THEY SHALL BE ESTABLISHED | | IN ACCORDANCE WITH SECTION 1612.3.1. | | | | 1612.4 DESIGN AND CONSTRUCTION. | | THE DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES | | LOCATED IN FLOOD HAZARD AREAS, INCLUDING COASTAL HIGH | | HAZARD AREAS, SHALL BE IN ACCORDANCE WITH CHAPTER 5 OF | | ASCE 7 AND WITH ASCE 24. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-01-07 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-01-07 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-01-07 |
Time |
15:00 |
Sent To |
|
|
Notes |
2016-01-07 15:29:28 | FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6700 | | [email protected] | | ALTERNATE CONTACT | | MIKE ALBARRAN | | 561-805-6746 | | [email protected] | | | | | | PROVISO: C405.2.4 EXTERIOR LIGHTING CONTROLS. | | LIGHTING NOT DESIGNATED FOR DUSK-TO-DAWN OPERATION | | SHALL BE CONTROLLED BY EITHER A COMBINATION OF A | | PHOTOSENSOR AND A TIME SWITCH, OR AN ASTRONOMICAL TIME | | SWITCH. LIGHTING DESIGNATED FOR DUSK-TO-DAWN OPERATION | | SHALL BE CONTROLLED BY AN ASTRONOMICAL TIME SWITCH OR | | PHOTOSENSOR. ALL TIME SWITCHES SHALL BE CAPABLE OF | | RETAINING PROGRAMMING AND THE TIME SETTING DURING LOSS | | OF POWER FOR A PERIOD OF AT LEAST 10 HOURS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-11-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-04 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-04 |
Time |
08:37 |
Sent To |
|
|
Notes |
2015-11-04 08:40:27 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | | | FBC107 - PROVIDE ELECTRICAL PLAN. | | | | ELECTRIC SIGNS, SECTION SIGNS, AND OUTLINE LIGHTING, | | FIXED, MOBILE, OR PORTABLE, SHALL BE LISTED AND | | INSTALLED IN CONFORMANCE WITH THAT LISTING, UNLESS | | OTHERWISE APPROVED BY SPECIAL PERMISSION. NEC 600.3 | | LISTING. | | | | EACH SIGN AND OUTLINE LIGHTING SYSTEM, OR FEEDER | | CIRCUIT OR BRANCH CIRCUIT SUPPLYING A SIGN OR OUT-LINE | | LIGHTING SYSTEM, SHALL BE CONTROLLED BY AN EXTERNALLY | | OPERABLE SWITCH OR CIRCUIT BREAKER THAT WILL OPEN ALL | | UNGROUNDED CONDUCTORS WITHIN SIGHT OF THE SIGN NEC | | 600.6(A)(1) | | | | ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 505.1 SHALL | | HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT OR WHEN | | NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR & TIME | | CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME SWITCHES | | SHALL BE CAPABLE OF RETAINING PROGRAMING DURING A LOSS | | OF POWER FOR A MINIMUM OF 10 HOURS. FBC-E 505.2.4 | | | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-01-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-01-08 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-12-18 |
Time |
14:13 |
Sent To |
|
|
Notes |
2015-12-18 14:13:56 | RESUB ROUTED TO JROACH VIA SGRAHAM'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-11-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-04 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-10-20 |
Time |
12:44 |
Sent To |
|
|
Notes |
2015-10-20 12:45:04 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-12-22 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2015-12-22 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2015-12-22 |
Time |
15:35 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-10-23 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2015-10-23 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2015-10-23 |
Time |
10:47 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |