Plan Review Details - Permit 15100234
Plan Review Stops For Permit 15100234
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-07-20 Cont ID  
Sent By cthroop Date 2016-07-20 Time 16:02 Rev Time 0.00
Received By cthroop Date 2016-07-20 Time 12:21 Sent To  
Notes
2016-07-20 16:16:18BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 ACTION: DENIED
 DATE: 7/20/16
  
 SCOPE OF WORK (SOW) CHANGED FROM RENOVATION OF EXISTING
 SFH TO CONSTRUCTION OF NEW SFH UTILIZING EXISTING WALLS
 PER FLOOR PLAN NOTE NOTE #3.
  
 1. PROVIDE DEMO PLAN HIGHLITING EXISTING WALLS TO
 REMAIN.
 2. ADJUST VALUE BASED ON NEW SOW.
 3. PROVIDE FOUNDATION PLAN IDENTIFYING EXISTING
 FOOTINGS TO REMAIN AND NEW FOOTINGS TO BE INSTALLED.
 4. PROVIDE FOOTING SCHEDULE.
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
 FAILURE TO PROVIDE DOCUMENTATION OF ESTIMATED COSTS MAY
 DELAY THE APPLICATION PROCESS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-19 Cont ID  
Sent By cthroop Date 2015-11-19 Time 11:30 Rev Time 0.00
Received By cthroop Date 2015-11-19 Time 11:30 Sent To  
Notes
2015-11-19 11:39:50CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 PROVIDE ENERGY CALCULATIONS.
  
 FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3
 STORIES.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM 402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-103.2.1.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM 405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 FBCE-103.2.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 PROVIDE NOA FOR SWING GLASS DOORS.
 PROVIDE NOA FOR SINGLE HUNG WINDOWS.
 PROVIDE PRODUCT APPROVAL FOR GARAGE FLOOD VENTS.
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW, AND DOOR SUBMITTALS.
  
 PLEASE REVIEW NFIP COMMENTS.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-07-11 Cont ID  
Sent By vperez Date 2016-07-11 Time 08:59 Rev Time 0.00
Received By vperez Date 2016-07-11 Time 08:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-11-18 Cont ID  
Sent By skennedy Date 2015-11-18 Time 09:28 Rev Time 0.00
Received By skennedy Date 2015-11-18 Time 09:28 Sent To  
Notes
2015-11-18 09:31:491ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 FBC 107 PROVIDE A SYSTEM GROUNDING DETAIL TO SHOW
 COMPLIANCE WITH THE BELOW SECTION.
  
 SECTION E3607 SYSTEM GROUNDING
  
 E3607.1 SYSTEM SERVICE GROUND.
 THE PREMISES WIRING SYSTEM SHALL BE GROUNDED AT THE
 SERVICE WITH A GROUNDING ELECTRODE CONDUCTOR CONNECTED
 TO A GROUNDING ELECTRODE SYSTEM AS REQUIRED BY THIS
 CODE. GROUNDING ELECTRODE CONDUCTORS SHALL BE SIZED IN
 ACCORDANCE WITH TABLE E3603.1.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-11-16 Cont ID  
Sent By skennedy Date 2015-11-16 Time 08:04 Rev Time 0.00
Received By skennedy Date 2015-11-15 Time 12:40 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2016-07-08 Cont ID  
Sent By fmittner Date 2016-07-08 Time 15:19 Rev Time 0.00
Received By fmittner Date 2016-07-08 Time 15:19 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-11-05 Cont ID  
Sent By fmittner Date 2015-11-05 Time 09:10 Rev Time 0.00
Received By fmittner Date 2015-11-05 Time 09:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-07-20 Cont ID  
Sent By cthroop Date 2016-07-20 Time 15:55 Rev Time 0.00
Received By cthroop Date 2016-06-28 Time 14:04 Sent To  
Notes
2016-06-28 14:04:43R25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-19 Cont ID  
Sent By cthroop Date 2015-11-19 Time 11:30 Rev Time 0.00
Received By cthroop Date 2015-10-07 Time 10:33 Sent To  
Notes
2015-11-05 10:34:57R25

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-07-20 Cont ID  
Sent By cthroop Date 2016-07-20 Time 13:46 Rev Time 0.00
Received By cthroop Date 2016-07-20 Time 13:46 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2015-11-16 Cont ID  
Sent By skennedy Date 2015-11-16 Time 08:03 Rev Time 0.00
Received By skennedy Date 2015-11-16 Time 08:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-07-18 Cont ID  
Sent By jvalido Date 2016-07-18 Time 17:30 Rev Time 0.00
Received By jvalido Date 2016-07-18 Time 17:27 Sent To  
Notes
2016-07-18 17:29:52CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE MECHANICAL PLANS.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (2) PROVIDE HEATLOAD CALCULATIONS.
 (3) PROVIDE FORM R405-214
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-11-16 Cont ID  
Sent By skennedy Date 2015-11-16 Time 08:04 Rev Time 0.00
Received By skennedy Date 2015-11-16 Time 08:04 Sent To  
Notes
2015-11-18 09:14:101ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 FBC- 107.3.5.3 ? PROVIDE A MECHANICAL PLAN TO SHOW
 SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER FBC-R
 M15.
  
 FBC-ER403.6.1 PROVIDE A SIZING CALCULATION
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2016-07-20 Cont ID  
Sent By cthroop Date 2016-07-20 Time 15:55 Rev Time 0.00
Received By cthroop Date 2016-07-20 Time 15:55 Sent To  
Notes
2016-07-20 15:57:58BLDG. WILL BE DEMOLISHED. NEW FINISH FLOOR ELEVATION TO
 BE 8.0' PER APPROVED PLANS. ELEVATIONH CERTIFICATES
 REQUIRED AT FOUNDATION, TIE BEAM AND PRIOR TO FINAL
 INSPECTION.

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2015-11-16 Cont ID  
Sent By shill Date 2015-11-16 Time 07:31 Rev Time 0.00
Received By shill Date 2015-11-16 Time 07:31 Sent To  
Notes
2015-11-16 08:05:04****CORRECTIONS****
 PLAN REVIEW IN PROGRESS
  
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. ADVISORY; THREE ELEVATION CERTIFICATES WILL BE
 REQUIRED; CONSTRUCTION DRAWINGS, BUILDING UNDER
 CONSTRUCTION, AND FINISHED CONSTRUCTION.
  
 A "FINISHED CONSTRUCTION" ELEVATION CERTIFICATE WAS
 PROVIDED FOR THE EXISTING STRUCTURE. A "CONSTRUCTION
 DRAWINGS" ELEVATION CERTIFICATE IS REQUIRED TO SHOW
 PROPOSED CONSTRUCTION. PLEASE REVISE AS FOLLOWS:
  
 A. A5, LAT/LONG COORDINATES - IF DEGREES, MINUTES,
 SECONDS FORMAT IS USED, SECONDS TO BE PROVIDED TO 1
 DECIMAL PLACE OR BETTER.
  
 B. A5, LAT/LONG COORDINATES, THIS IS TO BE ACCURATE
 WITHIN 66'.
  
 C. A SEPARATE PERMIT IS REQUIRED FOR THE DETACHED
 GARAGE. THE ELEVATION CERTIFICATE FOR THE HOUSE CAN
 INCLUDE THE GARAGE ON ONE CERTIFICATE, IF THE VALUE IS
 LESS THAN 10% OF THE MAIN STRUCTURE (PER FEMA).
 OTHERWISE, A SEPARATE ELEVATION CERTIFICATE IS REQUIRED
 FOR THE GARAGE.
  
 D. PHOTOGRAPHS ARE TO INCLUDE THE FLOOD OPENINGS. FLOOD
 OPENINGS ARE TO BE WITHIN 1' OF GRADE. PHOTOS TO SHOW
 COMPLIANCE.
  
 E. PROPOSED IMPROVEMENT AND EXISTING BUILDING IS TO
 COMPLY WITH FBC 5TH EDITION RESIDENTIAL 322, EXISTING
 BUILDING 701.3 AND CITY OF WEST PALM BEACH MUNICIPAL
 CODE 94-546(B). EXISTING STRUCTURE IS TO BE RAISED TO
 7.5' AS THIS IS A SUBSTANTIAL IMPROVEMENT. THESE CODE
 REFERENCES APPLY TO THE FOLLOWING COMMENTS.
  
 F. NON ENGINEERED FLOOD OPENINGS TO COMPLY WITH FBC
 RESIDENTIAL 322.2.2(2)(2.2). ELEVATION CERTIFICATE
 SHOULD BE REVISED TO SHOW PROPOSED OPENINGS (AND BE
 EXPLAINED IN COMMENTS SECTION). PLAN TO BE REVISED TO
 SHOW NEW PROPOSED ELEVATION FOR EXISTING STRUCTURE AS
 WELL AS EXISTING AND PROPOSED NEW FLOOD OPENINGS.
  
 G. A9, CONSTRUCTION DRAWINGS ELEVATION CERTIFICATE TO
 INCLUDE INFORMATION FOR PROPOSED GARAGE.
  
 H. B1, COMMUNITY NAME AND NUMBER INCORRECT, PLEASE
 REVISE.
  
 I. B4 THROUGH B7, MAP/PANEL NUMBER AND RELATED
 INFORMATION INCORRECT, PLEASE REVISE.
  
 J. C1, PLEASE PROVIDE A "CONSTRUCTION DRAWINGS"
 ELEVATION CERTIFICATE, WITH THE APPROPRIATE
 CHANGES/CORRECTIONS.
  
 K. MECHANICAL EQUIPMENT IS TO BE RAISED TO A MINIMUM OF
 7.5'.
  
 2. PROVIDE A TOPOGRAPHIC SURVEY AND A DRAINAGE PLAN
 WHICH INCLUDES THE ELEVATION OF PROPOSED FILL, FBC 2010
 RESIDENTIAL 401.3.
  
 110.7 IMPACT OF CONSTRUCTION. ALL CONSTRUCTION ACTIVITY
 REGULATED BY THIS CODE SHALL BE PERFORMED IN
 A MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF
 ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS
 PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT
 GRANTED BY THE APPLICABLE PROPERTY OWNER,
 UNDER TERMS OR CONDITIONS AGREEABLE TO THE APPLICABLE
 PROPERTY OWNER. THIS INCLUDES, BUT IS NOT
 LIMITED TO, THE CONTROL OF DUST, NOISE, WATER OR
 DRAINAGE RUN-OFFS, DEBRIS, AND THE STORAGE OF
 CONSTRUCTION MATERIALS. NEW CONSTRUCTION ACTIVITY SHALL
 NOT ADVERSELY IMPACT LEGAL HISTORIC SURFACE
 WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, AND
 MAY REQUIRE SPECIAL DRAINAGE DESIGN
 COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE DRAINAGE PATTERNS OF THE AFFECTED
 SITES. ACCORDINGLY, DEVELOPERS, CONTRACTORS AND OWNERS
 OF ALL NEW RESIDENTIAL DEVELOPMENT, INCLUDING
 ADDITIONS, POOLS, PATIOS, DRIVEWAYS, DECKS OR SIMILAR
 ITEMS, ON EXISTING PROPERTIES RESULTING IN A
 SIGNIFICANT DECREASE OF PERMEABLE LAND AREA ON ANY
 PARCEL OR HAS ALTERED THE DRAINAGE FLOW ON THE
 DEVELOPED PROPERTY SHALL, AS A PERMIT CONDITION,
 PROVIDE A PROFESSIONALLY PREPARED DRAINAGE PLAN
 CLEARLY INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON
 COMPLETION OF THE IMPROVEMENT, A
 CERTIFICATION FROM A LICENSED PROFESSIONAL SHALL BE
 SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 THE DRAINAGE PLAN SHOULD SHOW THE IMPACT OF FILLING
 THIS PROPERTY ON THE ADJACENT PROPERTIES.
  
 PLEASE NOTE THAT A DEVELOPMENT PERMIT IS REQUIRED FOR
 ALL CONSTRUCTION/DEVELOPMENT (INCLUDING FILL) IN THE
 SPECIAL HAZARD FLOOD AREA. THE PLAN SHOULD INCLUDE THE
 PROPOSED ELEVATION OF STRUCTURES, DRIVEWAY, AND POOL.
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-07-20 Cont ID  
Sent By skennedy Date 2016-07-20 Time 16:17 Rev Time 0.00
Received By skennedy Date 2016-07-20 Time 16:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-11-06 Cont ID  
Sent By tklarge Date 2015-11-06 Time 09:15 Rev Time 0.00
Received By tklarge Date 2015-11-06 Time 08:50 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2016-07-20 Cont ID  
Sent By cthroop Date 2016-07-20 Time 15:58 Rev Time 0.00
Received By cthroop Date 2016-07-20 Time 15:58 Sent To  
Notes
2016-07-20 16:02:40 
 BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 ACTION: DENIED
 DATE: 7/20/16
  
 NEW ROOF DESIGN. PRODUCT APPROVALS - OK.
  
 1. PROVIDE ROOF FRAMING PLAN.
 2. PROVIDE ROOF SHEATHING FASTENER SCHEDULE BASED ON
 DESIGN LOADS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2015-11-19 Cont ID  
Sent By cthroop Date 2015-11-19 Time 11:27 Rev Time 0.00
Received By cthroop Date 2015-11-19 Time 11:27 Sent To  
Notes
2015-11-19 11:30:06CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 NOA REQUIRED FOR LOW SLOPED ROOFING.
 PRODUCT APPROVAL RERQUIRED FOR ROOF INSULATION.
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  
2015-11-15 12:33:21ROOFING

Review Stop Z ZONING
Rev No 2 Status P Date 2016-07-08 Cont ID  
Sent By fmittner Date 2016-07-08 Time 15:19 Rev Time 0.00
Received By fmittner Date 2016-07-08 Time 15:19 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-11-05 Cont ID  
Sent By fmittner Date 2015-11-05 Time 09:10 Rev Time 0.00
Received By fmittner Date 2015-11-05 Time 09:10 Sent To  
Notes
***NONE***