Plan Review Details - Permit 15100233
Plan Review Stops For Permit 15100233 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-12-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-12-30 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-12-30 |
Time |
07:00 |
Sent To |
|
|
Notes |
2015-12-30 08:36:14 | BUILDING PLAN REVIEW | | W. P. B. PERMIT:15100233 | | ADD: 428 AVON RD. (PLUMB PERMIT APP) | | CONT: DON LIPSCOMB PLUMBING | | TEL: (561)310-9245 | | E-MAIL: ??????????????????? | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: FRI. NOV. 06/2015 | | ACTION: DENIED | | 2749 SQ. FT./ 30(MERCANTILE)= 92 OCCUPANTS | | | | 1) COMPLIED. PLEASE MAKE CORRECTIONS FOR ADDRESSING THE | | SURVEY BY TARGET, SHEET A.02 INDICATES TWO SEPARATE | | BUILDINGS ON TWO SEPARATE LOTS AND DIFFERENT PROPERTY | | CONTROL NUMBERS. | | THE SURVEY INDICATES BY WAY OF A BUBBLE THE BUILDING | | LOCATED ON LOT 1480 ADDRESSED 428 AVON RD. | | | | 2) 2ND REQUEST. THIS PERMIT IS BEING PULLED UNDER A CFC | | LICENSE, THE SCOPE OF WORK IS BEYOND WHAT A PLUMBING | | CONTRACTOR CAN DO, F. S. 489.105(M). A BUILDING, | | ELECTRICAL AND MECHANICAL CONTRACTOR WILL NEED TO SIGN | | ONTO THIS PROJECT BEFORE IT CAN BE ISSUED. | | | | 3) 2ND REQUEST. 2014 ENERGY CODE C101.5.1.1 | | ALTERATIONS, RENOVATIONS AND BUILDING SYSTEMS. | | ALTERATIONS, RENOVATIONS AND BUILDING SYSTEMS MAY | | UTILIZE FORM C402. FORM C402 CAN BE FOUND IN APPENDIX | | C. | | | | 4) COMPLIED. SHEET A0.4 INDICATES THE NEW RESTROOM DOOR | | TO BE A 2'-8" DOOR. PLEASE REVIEW 2014 FBC-ACCESSIBLITY | | CODE 404.2.3 404.2.3 CLEAR WIDTH. DOOR OPENINGS SHALL | | PROVIDE A CLEAR WIDTH OF 32 INCHES (815 MM) MINIMUM. | | CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE | | MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, | | WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 | | INCHES (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF | | 36 INCHES (915 MM) MINIMUM. THERE SHALL BE NO | | PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER | | THAN 34 INCHES (865 MM) ABOVE THE FINISH FLOOR OR | | GROUND. | | | | 5) 2ND REQUEST. CHANGE OF OCCUPANCY BUSINESS TO | | MERCANTILE. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 6A) NEW COMMENT. SHEET A-01 NOW SHOWS A NEW PAVED 60 X | | 60 INCH RAMP WITH 2 STEEL BOLLARDS. NOTE FOR RAMPS A | | TOP LANDING AND BOTTOM LANDING ARE REQUIRED. 2014 | | FBC-ACCESSIBILITY CODE 405.7 LANDINGS. RAMPS SHALL HAVE | | LANDINGS AT THE TOP AND THE BOTTOM OF EACH RAMP RUN. | | LANDINGS SHALL COMPLY WITH 405.7. E.01 SHOWS THIS IS | | ONE OF THE 2 REQUIRED EXITS. | | | | 6B) NEW COMMENT. SINCE 2 ACCESSIBLE MEANS OF EGRESS ARE | | REQUIRED PLEASE PROVIDE WHICH OF THE OTHER EXITS | | COMPLIES WITH 2014 FBC-ACCESSIBILITY CODE 207.1 & | | SECTION 1007.1 OF THE 2003 IBC WHERE MORE THAN ONE | | MEANS OF EGRESS IS REQUIRED BY SECTION 1014.1 OR 1018.1 | | FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF | | THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO | | ACCESSIBLE MEANS OF EGRESS. | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-11-06 |
|
|
Cont ID |
|
Sent By |
|
Date |
2015-11-06 |
Time |
15:45 |
Rev Time |
|
Received By |
|
Date |
2015-11-06 |
Time |
14:55 |
Sent To |
|
|
Notes |
2015-11-06 15:35:37 | BUILDING PLAN REVIEW | | W. P. B. PERMIT:15100233 | | ADD: 428 AVON RD. (PERMIT APP) | | CONT: DON LIPSCOMB PLUMBING | | TEL: (561)310-9245 | | E-MAIL: ??????????????????? | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: FRI. NOV. 06/2015 | | ACTION: DENIED | | | | 1) PLEASE MAKE CORRECTIONS FOR ADDRESSING THE SURVEY BY | | TARGET, SHEET A.02 INDICATES TWO SEPARATE BUILDINGS ON | | TWO SEPARATE LOTS AND DIFFERENT PROPERTY CONTROL | | NUMBERS. | | THE SURVEY INDICATES BY WAY OF A BUBBLE THE BUILDING | | LOCATED ON LOT 1480 ADDRESSED 428 AVON RD. | | | | THE BUILDING PLANS ARE ADDRESSED 429 AVON AND NEED TO | | BE CORRECTED, TO 428 AVON RD. THE OTHER ISSUE IN DOING | | A ADDRESS SEARCH THE PERMIT APPLICATION HAS THE WRONG | | LOT ON THE PERMIT APPLICATION OF LOT 1487 THE CORRECT | | LOT NUMBER IS 1480. 107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK TO BE COMPLETED UNDER THIS PERMIT. | | | | 2) THIS PERMIT IS BEING PULLED UNDER A CFC LICENSE, THE | | SCOPE OF WORK IS BEYOND WHAT A PLUMBING CONTRACTOR CAN | | DO, F. S. 489.105(M). A BUILDING, ELECTRICAL AND | | MECHANICAL CONTRACTOR WILL NEED TO SIGN ONTO THIS | | PROJECT BEFORE IT CAN BE ISSUED. | | | | 3) 2014 ENERGY CODE C101.5.1.1 ALTERATIONS, RENOVATIONS | | AND BUILDING SYSTEMS. ALTERATIONS, RENOVATIONS AND | | BUILDING SYSTEMS MAY UTILIZE FORM C402. FORM C402 CAN | | BE FOUND IN APPENDIX C. | | | | 4) SHEET A0.4 INDICATES THE NEW RESTROOM DOOR TO BE A | | 2'-8" DOOR. PLEASE REVIEW 2014 FBC-ACCESSIBLITY CODE | | 404.2.3 404.2.3 CLEAR WIDTH. DOOR OPENINGS SHALL | | PROVIDE A CLEAR WIDTH OF 32 INCHES (815 MM) MINIMUM. | | CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE | | MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, | | WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 | | INCHES (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF | | 36 INCHES (915 MM) MINIMUM. THERE SHALL BE NO | | PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER | | THAN 34 INCHES (865 MM) ABOVE THE FINISH FLOOR OR | | GROUND. | | | | 5) CHANGE OF OCCUPANCY BUSINESS TO MERCANTILE. BEFORE A | | PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT FEES MUST BE | | PAID TO PALM BEACH COUNTY. THE ACTUAL PERMIT SET OF | | PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE | | PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE | | CALL (561)233-5025 FOR MORE INFORMATION. | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2016-01-25 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-01-25 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-01-25 |
Time |
10:25 |
Sent To |
|
|
Notes |
2016-01-25 11:02:38 | FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6700 | | [email protected] | | ALTERNATE CONTACT | | MIKE ALBARRAN | | 561-805-6746 | | [email protected] | | | | JOB PERMIT NUMBER: 15100233 | | JOB ADDRESS: 428 AVON ROAD | | WEST PALM BEACH | | DATE: JAN 25 2016 | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | 1- PLEASE PROVIDE A MORE DETAILED RISER DIAGRAM TO | | INCLUDE LOAD CALCULATION, PANEL SCHEDULES, GROUNDING | | SPECS, WIRE AND CONDUIT ROUTING. FBC-107.3.5.3 AND NEC | | 215.5 | | 2- PROVIDE CLARIFICATION OF 2 SERVICES IN ONE BUILDING | | AND NO OUTSIDE DISCONNECTING MEANS FOR FEEDER | | CONDUCTORS ? ARE THESE SERVICE CONDUCTORS CONSIDERED TO | | BE OUTSIDE OF THE BUILDING ? NEC 230.2 , NEC 230.6, NEC | | 230.70 A1 | | 3- EMERGENCY AND EXIT LIGHTS SHALL BE FED BY LIGHTING | | CIRCUIT OF SAME LOCAL AREA AHEAD OF ANY LOCAL SWITCHES. | | NEC 700.12 F | | 4- THE LOCATION OF SMOKE DETECTORS SHALL BE BASED ON | | POTENTIAL AMBIENT SOURCES OF SMOKE, MOISTURE, DUST OR | | FUMES, AND ELECTRICAL OR MECHANICAL INFLUENCES TO | | MINIMIZE NUISANCE ALARMS. (NOT PERMITTED IN BATHROOMS) | | NFPA 17.7.1.9 | | 5- MANDATORY LIGHTING CONTROLS SHALL BE INSTALLED IN | | ALL BATHROOMS (OCCUPANCY SENSORS) FBC-E C405 2.2.2 | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | MENTIONED DEFICIENCIES. | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-11-13 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-13 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-13 |
Time |
07:44 |
Sent To |
|
|
Notes |
2015-11-13 07:50:34 | 1ST REVIEW: FBC 2014 5TH ED./ NEC 2011 | | EXISTING BUILDING CHANGE OF OCCUPANCY | | | | THIS IS A QUALITY CHECK OF THE PREVIUOS REVIEW | | PERFORMED BY A CONTRACT EMPLOYEE REVERSING THE RESULT | | OF THAT REVIEW TO A STATUS OF FAIL AS FOLLOWS: | | | | THE PLANS ARE DEFICIENT AS MINIMUM PLAN REVIEW CRIRERIA | | TO DETERMINE COMPLIANCE IS NOT PROVIDED. PLEASE INCLUDE | | AN ELECTRCAL TO TO INDICATE AT THE MINIMUM, THE | | FOLLOWING. | | | | FBC 107.3.5.1.2 ELECTRICAL | | 1. ELECTRICAL: | | WIRING | | SERVICES | | FEEDERS AND BRANCH CIRCUITS | | OVERCURRENT PROTECTION | | GROUNDING | | WIRING METHODS AND MATERIALS | | GFCIS | | 2. EQUIPMENT | | 3. SPECIAL OCCUPANCIES | | 4. EMERGENCY SYSTEMS | | 5. COMMUNICATION SYSTEMS | | 6. LOW VOLTAGE | | 7. LOAD CALCULATIONS | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2015-11-05 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2015-11-05 |
Time |
14:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-12-30 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-12-30 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-12-30 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2015-11-04 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-11-04 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-11-04 |
Time |
09:58 |
Sent To |
|
|
Notes |
2015-11-04 10:14:38 | 428 AVON ROAD | | PERMIT #15100233 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | PERMIT APPLICATION INDICATES AN ADDRESS OF 428 AVON | | ROAD; HOWEVER, PLANS INDICATE AN ADDRESS OF 429 AVON | | ROAD. | | | | DESIGN SHALL CONFORM TO THE 5TH EDITION OF THE FLORIDA | | FIRE PREVENTION CODE WHICH CONTAINS THE 2012 EDITION OF | | BOTH NFPA 1 AND NFPA 101 WITH FLORIDA AMENDMENTS. | | | | PLANS INDICATE A CHANGE OF OCCUPANCY FROM BUSINESS TO | | MERCANTILE. PROVIDE A BUILDING AREA BREAKDOWN WITH | | OCCUPANT LOAD COUNT. | | | | PLANS INDICATE STORAGE RACK LAYOUTS. WHAT IS BEING | | STORED? HOW TALL IS THE STORAGE? | | | | PLANS INDICATE EMERGENCY LIGHT AND EXIT SIGN FIXTURES; | | HOWEVER, NO ELECTRICAL PLAN OR ELECTRICAL INFORMATION | | HAS BEEN PROVIDED. | | | | PROVIDE BOLLARDS OR SIMILAR TO PREVENT VEHICLES FROM | | BLOCKING EXIT DOORS IN PARKING LOT. | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | EXIT SIGNS. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-01-25 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-01-25 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-12-18 |
Time |
13:55 |
Sent To |
|
|
Notes |
2016-01-25 08:49:15 | 1/25 TO MVALDES DESK | | | | | 2015-12-18 13:55:23 | B10 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-11-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-11-06 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-10-07 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2015-12-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-12-21 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-12-21 |
Time |
17:07 |
Sent To |
|
|
Notes |
2015-12-21 17:10:18 | 2ND REVIEW 2014 MECHANICAL | | PERMIT #15100233 | | 12/21/15 | | | | THE 1ST REVIEW COMMENTS STILL EXIST. I HAVE RE-PRINTED | | THEM BELOW FOR REVIEW, PLEASE COMPLY. | | 1) REFER TO SECTION C101.4.4 FBC-14 ENERGY | | CONSERVATION: CHANGE IN OCCUPANCY OR USE. | | SPACES UNDERGOING A CHANGE IN OCCUPANCY THAT WOULD | | RESULT IN AN INCREASE IN DEMAND FOR EITHER FOSSIL FUEL | | OR ELECTRICAL ENERGY SHALL COMPLY WITH THIS CODE. WHERE | | THE USE IN A SPACE CHANGES FROM ONE USE IN TABLE | | C405.5.2(1) OR (2) TO ANOTHER USE IN TABLE C405.5.2(1) | | OR (2), THE INSTALLED LIGHTING WATTAGE SHALL COMPLY | | WITH SECTION C405.5. | | IN ACCORDANCE WITH THIS SECTION PLEASE PROVIDE ENERGY | | CALCULATIONS- SEE THE FOLLOWING SECTIONS FOR COMPLIANCE | | SUBMITTAL INFORMATION: C101.5.1 COMPLIANCE MATERIALS. | | THE FLORIDA BUILDING COMMISSION SHALL APPROVE SPECIFIC | | COMPUTER SOFTWARE. THE CODE OFFICIAL SHALL BE PERMITTED | | TO APPROVE WORKSHEETS, COMPLIANCE MANUALS AND OTHER | | SIMILAR MATERIALS THAT MEET THE INTENT OF THIS CODE. | | C101.5.1.1 ALTERATIONS, RENOVATIONS AND BUILDING | | SYSTEMS. ALTERATIONS, RENOVATIONS AND BUILDING SYSTEMS | | MAY UTILIZE FORM C402. FORM C402 CAN BE FOUND IN | | APPENDIX C. | | 2) REFER TO SECTION 1009.1 FBC-14 EXISTING BUILDING | | CODE AND PROVIDE MINIMUM VENTILATION CALCULATIONS ON | | THE PLAN IN ACCORDANCE WUITH TABLE 403.3 FBC-14 | | MECHANICAL. THE CALCULATIONS SHALL INDICATE THE AMOUNT | | OF CFM'S OF OUTSIDE AIR REQUIRED FOR THE RETAIL SPACE | | OCCUPANTS, AND THE AMOUNT OF CFM'S PROVIDED BY THE | | EXISTING OR PROPOSED SYSTEMS. | | 3) MECHANICAL EXHAUST IS REQUIRED FOR THE NEW TOILET | | ROOM IN COMPLIANCE WITH TABLE 403.3 FBC-14 MECHANICAL. | | PLEASE REVISE THE PLANS TO SHOW COMPLIANCE. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-11-05 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-11-05 |
Time |
11:46 |
Sent To |
|
|
Notes |
2015-11-05 11:53:13 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT #15100233 | | 11/5/2015 | | | | 1) REFER TO SECTION C101.4.4 FBC-14 ENERGY | | CONSERVATION: CHANGE IN OCCUPANCY OR USE. | | SPACES UNDERGOING A CHANGE IN OCCUPANCY THAT WOULD | | RESULT IN AN INCREASE IN DEMAND FOR EITHER FOSSIL FUEL | | OR ELECTRICAL ENERGY SHALL COMPLY WITH THIS CODE. WHERE | | THE USE IN A SPACE CHANGES FROM ONE USE IN TABLE | | C405.5.2(1) OR (2) TO ANOTHER USE IN TABLE C405.5.2(1) | | OR (2), THE INSTALLED LIGHTING WATTAGE SHALL COMPLY | | WITH SECTION C405.5. | | IN ACCORDANCE WITH THIS SECTION PLEASE PROVIDE ENERGY | | CALCULATIONS- SEE THE FOLLOWING SECTIONS FOR COMPLIANCE | | SUBMITTAL INFORMATION: C101.5.1 COMPLIANCE MATERIALS. | | THE FLORIDA BUILDING COMMISSION SHALL APPROVE SPECIFIC | | COMPUTER SOFTWARE. THE CODE OFFICIAL SHALL BE PERMITTED | | TO APPROVE WORKSHEETS, COMPLIANCE MANUALS AND OTHER | | SIMILAR MATERIALS THAT MEET THE INTENT OF THIS CODE. | | C101.5.1.1 ALTERATIONS, RENOVATIONS AND BUILDING | | SYSTEMS. ALTERATIONS, RENOVATIONS AND BUILDING SYSTEMS | | MAY UTILIZE FORM C402. FORM C402 CAN BE FOUND IN | | APPENDIX C. | | 2) REFER TO SECTION 1009.1 FBC-14 EXISTING BUILDING | | CODE AND PROVIDE MINIMUM VENTILATION CALCULATIONS ON | | THE PLAN IN ACCORDANCE WUITH TABLE 403.3 FBC-14 | | MECHANICAL. THE CALCULATIONS SHALL INDICATE THE AMOUNT | | OF CFM'S OF OUTSIDE AIR REQUIRED FOR THE RETAIL SPACE | | OCCUPANTS, AND THE AMOUNT OF CFM'S PROVIDED BY THE | | EXISTING OR PROPOSED SYSTEMS. | | 3) MECHANICAL EXHAUST IS REQUIRED FOR THE NEW TOILET | | ROOM IN COMPLIANCE WITH TABLE 403.3 FBC-14 MECHANICAL. | | PLEASE REVISE THE PLANS TO SHOW COMPLIANCE. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-12-26 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-12-26 |
Time |
03:09 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-12-26 |
Time |
02:40 |
Sent To |
|
|
Notes |
2015-12-26 02:50:02 | 1) A SANITARY AND WATER RISER IS REQUIRED FOR THE NEW | | SERVICE SINK, THE NEW DRINKING FOUNTAINS AND A WATER | | RISER IS REQUIRED FOR THE ADDITION OF THE NEW TANKLESS | | WATER HEATER PER THE CITY OF WPB AMEND. TO THE FBC SEC. | | 107.3.5.1.3. SUBMIT TWO COPIES OF A WATER AND SANITARY | | RISER FOR REVIEW. 2ND REQUEST. | | 2) THE GRAB BARS SHALL BE MEASURED TO THE TOP OF THE | | GRIPPING SURFACE, NOT TO CENTERLINE AS SHOWN ON | | SHT.A.03. 2014 FBC ACCESSIBILITY SEC. 609.4. 2ND | | REQUEST. | | 3) THE TOILET PAPER DISPENSER SHALL BE LOCATED 7-9 | | INCHES FROM THE FRONT OF THE WATER CLOSET TO THE | | CENTERLINE OF THE DISPENSER. 2014 FBCA- SEC.604.7 | | 4) PLEASE UPDATE THE MODIFICATION NOTE ON SHT.A.01 TO | | INCLUDE THE ADDITION OF THE DRINKING FOUNTAINS, THE MOP | | SINK, THE TANKLESS WATER HEATER AND THE ADDITION OF THE | | HOT WATER PIPING. WPB AMEND. TO FBC SEC. 107.2.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-10-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-10-09 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-10-09 |
Time |
17:14 |
Sent To |
|
|
Notes |
2015-10-13 06:59:19 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | | | | | | | PLUMBING COMMENTS: | | | | 1.SHOW CLEAR FLOOR SPACE FOR LAVATORY IN ACCESSIBLE | | BATHROOM. | | PER WPB AMEN. SEC 107.2.1 | | 2.GRAB BARS SHALL COMPLY WITH.FBC ACC SEC 609.4 | | POSITION OF GRAB BARS. | | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, | | 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | THE GRIPPING SURFACE, EXCEPT THAT AT WATER CLOSETS FOR | | CHILDREN?S USE COMPLYING WITH 604.9, GRAB BARS SHALL BE | | INSTALLED IN A HORIZONTAL POSITION 18 INCHES (455 MM) | | MINIMUM AND 27 INCHES (685 MM) MAXIMUM ABOVE THE FINISH | | FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. THE | | HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A | | BATHTUB SHALL COMPLY WITH 607.4.1.1 OR 607.4.2.1. | | 3.TOILET SHALL COMPLY WITH FBC ACC.SEC 604.2 LOCATION. | | THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR | | PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE | | OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM | | TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR | | PARTITION, | | 4. A DRINKING FOUNTAIN IS REQUIRED TO COMPLY WITH FBC | | ACC. SEC | | 211.2 MINIMUM NUMBER. | | NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | 602.7. | | | | EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES | | WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE | | PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING | | FOUNTAINS. | | | | 5.PROVIDE SANITARY AND WATER RISER DIAGRAM. | | PER WPB AMEN. 107 .3.5.1.3(13) | | THE FOLLOWING IS AN UPDATED PLUMBING REVIEW AS OF | | 12/9/15; | | 1) SUBMIT AN EXISTING FLOOR PLAN AND A PROPOSED FLOOR | | PLAN THAT CLEARLY REFLECTS THE ENTIRE SCOPE OF WORK | | BEING DONE TO THE EXISTING TOILET ROOM. WPB AMEND. TO | | FBC SEC. 107.2.1. | | 2) SINCE THIS IS A CHANGE OF OCCUPANCY, A SERVICE SINK | | IS REQUIRED FOR A MERCANTILE OCCUPANCY PER THE 2014 | | FBC-PLBG. TABLE 403.1. | | 3) SUBMIT A SANITARY AND WATER RISER DIAGRAM FOR REVIEW | | FOR ALL NEW PLUMBING FIXTURES. WPB AMEND. TO FBC SEC. | | 107.3.5.1.3. | | 4) THE LAVATORY IN THE ADA TOILET ROMM AND THE MOP SINK | | SHALL BE SUPPLIED WITH HOT OR TEMPERED WATER PER 2014 | | FBC -PLBG.SEC.607.1. | | 5)SHOW THE REQUIRED CLEAR FLOOR SPACE FOR THE WATER | | CLOSET AND THE LAVATORY IN ADA TOILET ROOM PER THE 2014 | | FBC-ACCESS.SEC.604.3.1. & SEC. 606.2 & SEC.305. | | 6) SHT. A.01 - THE UPDATE MODIFICATION NOTE SHALL | | INCLUDE THE ADDITION OF THE DRINKING FOUNTAINS, THE MOP | | SINK AND THE REQUIREMENT FOR HOT WATER TO THE SCOPE OF | | WORK. WPB AMEND.TO FBC 107.2.1 | | 7) THE TOILET PAPER DISPENSER SHALL BE LOCATED 7-9 | | INCHES TO THE CENTERLINE FROM THE FRONT OF THE WATER | | CLOSET. 2014 FBC-ACCESS SEC.604.7. | | 8) THE DRINKING FOUNTAINS SHALL COMPLY WITH 2014 | | FBC-ACCESS. SEC. 307.2. FOR PROTRUSION LIMITS. A SKIRT | | ON THE DRINKING FOUNTAINS MAY BE REQUIRED TO COMPLY. | | SUBMIT MANUF. SPCIFICATION SHEETS FOR THE ACCESSIBLE | | DRINKING FOUNTAIN THAT CLEARLY SHOWS THE HEIGHT OF THE | | LEADING EDGES OF THE UNIT. WPB AMEND. TO FBC SEC. | | 107.2.1. | | 9) TWO SETS OF PLANS REQUIRED WPB AMEND. TO FBC | | SEC107.1 THREE SETS OF PLANS HAVE BEEN VOIDED AND ONE | | HAS NOT LEAVING OMLY ONE SET FOR REVIEW. |
|
|
|