Plan Review Details - Permit 15100162
Plan Review Stops For Permit 15100162
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-11-24 Cont ID  
Sent By skennedy Date 2015-11-24 Time 16:48 Rev Time 0.00
Received By skennedy Date 2015-11-24 Time 16:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-02 Cont ID  
Sent By skennedy Date 2015-11-02 Time 08:26 Rev Time 0.00
Received By skennedy Date 2015-11-02 Time 08:26 Sent To  
Notes
2015-11-01 11:49:001ST REVIEW: FBC 2014 5TH ED. NEC 2011
  
 IT IS DIFFICULT TO ACERTAIN IF THE SUBMITTED PLAN HAS
 AN ORIGINAL SIGNATUR FRO THE ENGINEER OF RECORD
 CHRISTIAN LANGLEY PE#67382. IS THE EASY SEAL INSIGNIA A
 DIGALTAL SIGNATURE AUTHENTIFICATION METHOD? PLEASE
 CONFIRM THE SEAL COMPLIES WITH THE CRITERIA IN FAC 61G
 OR IF INTENDED TO BE DIGITAL, THEN FAC 61G1-16.005, IF
 SO, SUBMIT DIGITALLY.
  
 THE PLAN PROVIDES FOR CONNECTOR OPTIONS BASED UPON THE
 SUBSTRATE. PLEASE IDENTIFY THE SUBSTRATE AND SPECIFY A
 CONNECTOR OPTION.
  
 SEE ELECTRICAL COMMENTS.
 THERE IS A STATEMENT ON THE PLAN INDICATING THE DESIGN
 IS FOR STRUCTURAL INTEGRITY ONLY AND THAT THE
 ELECTRICAL DESIGN ON THE PLAN IS THE SOLE
 RESPONSIBILITY OF THE ELECTRICIAN. PLEASE PROVIDE AN
 ELECTRICAL DESIGN BY SOMEONE RESPONSIBLE. INDICATE AT A
 MINIMUM COMPLIANCE WITH THE FOLLOWING AS APPLICABLE:
 APPLICABLE ELECTRICAL CODE IN EFFECT,
 NEC . 600, LISTING. DISCONNECT
 FBC 505, AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT OR
 WHEN NOT REQUIRED.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-11-24 Cont ID  
Sent By skennedy Date 2015-11-24 Time 16:48 Rev Time 0.00
Received By skennedy Date 2015-11-24 Time 16:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-11-01 Cont ID  
Sent By skennedy Date 2015-11-01 Time 11:46 Rev Time 0.00
Received By skennedy Date 2015-11-01 Time 11:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-11-24 Cont ID  
Sent By skennedy Date 2015-11-24 Time 16:48 Rev Time 0.00
Received By skennedy Date 2015-11-09 Time 15:51 Sent To  
Notes
2015-11-09 15:51:47RESUB ROUTED TO ESCHNEIDER VIA SGRAHAM'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-02 Cont ID  
Sent By skennedy Date 2015-11-02 Time 08:26 Rev Time 0.00
Received By skennedy Date 2015-10-06 Time 12:40 Sent To  
Notes
2015-10-07 12:40:30ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2015-11-24 Cont ID  
Sent By eschneid Date 2015-11-24 Time 13:29 Rev Time 0.25
Received By eschneid Date 2015-11-24 Time 13:28 Sent To B
Notes
2015-11-24 13:35:22NORTHEAST FACADE BUILDING IDENTITY SIGN - HILTON TEXT
 ONLY
  
 ALLOWED: 200 SQ. FT.
 PROPOSED: 69.9 SQ. FT.
  
 PLEASE NOTE: THE SIGN CODE PERMITS TWO TYPES OF SIGNS
 FOR THIS BUILDING, THE BUILDING IDENTITY SIGN AND THE
 EXTERNAL SIGN BAND. THE PROPOSED NORTHEAST FACADE SIGN
 IS TOO TALL TO BE AN EXTERNAL SIGN BAND (MAXIMUM HEIGHT
 36 INCHES), SO STAFF IS REVIEWING IT AS A BUILDING
 IDENTITY SIGN. THERE MAY BE ONLY TWO BUILDING IDENTITY
 SIGNS PER BUILDING, SO NO MORE BUILDING IDENTITY SIGNS
 WOULD BE PERMITTED.

Review Stop Z ZONING
Rev No 1 Status F Date 2015-10-28 Cont ID  
Sent By eschneid Date 2015-10-28 Time 09:50 Rev Time 0.25
Received By eschneid Date 2015-10-28 Time 09:50 Sent To B
Notes
2015-10-28 10:54:15NORTHEAST FACADE SIGN
  
 1) STAFF IS CONFUSED BY WHAT IS ACTUALLY BEING
 PERMITTED FOR THE SIGN ON THE NORTHEAST ELEVATION. THE
 BARON SIGN COLOR RENDERING SHEETS 1 AND 2 SHOWS THE
 WORD "HILTON" WITH SCRIPT "WEST PALM BEACH" BELOW. THE
 BARON SIGN DETAIL SHEET 1 SHOWS ONLY THE WORD "HILTON".
  
 2) THE SIGN CODE PERMITS TWO TYPES OF SIGNS FOR THIS
 BUILDING, THE BUILDING IDENTITY SIGN AND THE EXTERNAL
 SIGN BAND. THE PROPOSED NORTHEAST FACADE SIGN IS TOO
 TALL TO BE AN EXTERNAL SIGN BAND (MAXIMUM HEIGHT 36
 INCHES), SO STAFF IS REVIEWING IT AS A BUILDING
 IDENTITY SIGN. THERE MAY BE ONLY TWO BUILDING IDENTITY
 SIGNS PER BUILDING, SO NO MORE BUILDING IDENTITY SIGNS
 WOULD BE PERMITTED.
  
 3) THE DIMENSIONS WERE ONLY SHOWN FOR THE "HILTON"
 TEXT. IF THIS IS TO BE THE ONLY SIGN ON THE WESTERN
 FACADE, THEN THE SIZE COMPLIES WITH THE CODE.
  
 NORTHEAST FACADE BUILDING IDENTITY SIGN - HILTON TEXT
 ONLY
  
 ALLOWED: 200 SQ. FT.
 PROPOSED: 69.9 SQ. FT.
  
 4) WHY IS THIS SIGN ALSO INCLUDED WITH PERMIT NO.
 15091362?
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.