Plan Review Details - Permit 15100158
Plan Review Stops For Permit 15100158
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-02-10 Cont ID  
Sent By jgomez Date 2016-02-10 Time 15:48 Rev Time 0.00
Received By jgomez Date 2016-02-10 Time 15:48 Sent To  
Notes
2016-02-10 15:59:57 
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-01-05 Cont ID  
Sent By jgomez Date 2016-01-05 Time 12:09 Rev Time 0.00
Received By jgomez Date 2016-01-05 Time 12:09 Sent To Z
Notes
2016-01-05 12:10:39RESIDENTIAL (R3) REAR BUILDING ALTERATION SECOND
 BUILDING REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- PROVIDE 2 COPIES OF SIGNED AND SEALED DRAWINGS
 (ORIGINAL SEAL AND SIGNATURE). ONLY ONE COPY WAS
 SUBMITTED. SEC. 107.1 CITY AMENDMENTS.
  
 2- THERE ARE NOT DRAWINGS SHOWING THE SCOPE OF WORK
 SPECIFIED ON THE PERMIT APPLICATION. PROVIDE COMPLETE
 FLOOR PLANS SHOWING ALL THE SCOPE OF WORK DESCRIBED IN
 THE PERMIT APPLICATION. SEC. 107.2.1 CITY AMENDMENTS.
 NOTE: THERE ARE RED TAGS ON THIS PROPERTY FOR ALL
 TRADES FOR DOING WORK WITHOUT PERMIT. NEED PLANS
 SHOWING ALL THE SCOPE OF WORK FOR PROPER PLAN REVIEW,
 INSPECTIONS AND RECORD KEEPING PURPOSES.
  
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. ONLY THE
 STAIRS SCOPE OF WORK WAS SHOWN ON SHEET S2.00. NEED
 PLANS SHOWING THE REST OF THE SCOPE OF WORK SPECIFIED
 ON THE PERMIT APPLICATION.
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. CLEARLY SPECIFY ALL SCOPE OF WORK, INCLUDING THE
 REBUILDING OF THE EXTERIOR STAIRCASE. REVISE SCOPE OF
 WORK AND VALUATION ON THE PERMIT APPLICATION. VALUATION
 TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD
 AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS REQUIRED
 BY SEC. 109.3 CITY AMENDMENTS. . PROVIDE COPIES OF
 SIGNED CONTRACTS FOR CONTRACTOR'S FEES AND FOR DESIGN
 PROFESSIONAL FEES.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 4- SHEET S2.00: EXTERIOR TYPICAL STAIR SECTION DETAIL
 SPECIFIES 8" RISER. 8" RISERS ARE NOT ALLOWED. SEE SEC.
 R311.7.5.1 OF FBC-RESIDENTIAL, 5TH EDITION (2014) AND
 REVISE AS REQUIRED.
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR ALL SIMPSON STRUCTURAL
 CONNECTORS SPECIFIED ON THE DETAILS. PROVIDE ONLY THE
 FLORIDA PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING
 THE SPECIFIED CONNECTOR OR DESIGNER OF RECORD TO
 SPECIFY THE FLORIDA PRODUCT APPROVAL NEXT TO EACH
 SPECIFIED CONNECTOR.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-09 Cont ID  
Sent By jgomez Date 2015-11-09 Time 17:11 Rev Time 0.00
Received By jgomez Date 2015-11-06 Time 18:39 Sent To  
Notes
2015-11-09 17:23:45RESIDENTIAL (R3) REAR BUILDING ALTERATION BUILDING
 REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- THERE ARE NOT DRAWINGS SHOWING THE SCOPE OF WORK
 SPECIFIED ON THE PERMIT APPLICATION. PROVIDE COMPLETE
 FLOOR PLANS SHOWING ALL THE SCOPE OF WORK DESCRIBED IN
 THE PERMIT APPLICATION. SEC. 107.2.1 CITY AMENDMENTS.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. CLEARLY SPECIFY ALL SCOPE OF WORK, INCLUDING THE
 REBUILDING OF THE EXTERIOR STAIRCASE. REVISE SCOPE OF
 WORK AND VALUATION ON THE PERMIT APPLICATION. VALUATION
 TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD
 AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS REQUIRED
 BY SEC. 109.3 CITY AMENDMENTS. . PROVIDE COPIES OF
 SIGNED CONTRACTS FOR CONTRACTOR'S FEES AND FOR DESIGN
 PROFESSIONAL FEES.
  
 3- SHEET S2.00:
 A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 FRAMING OF THE HANDRAIL AND GUARDRAIL TO SHOW
 COMPLIANCE WITH THE LIVE LOADS OF TABLE R301.5 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014). CLEARLY SPECIFY
 ALL CONNECTORS.
  
 B) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 RECONSTRUCTION OF THE STAIRCASE. CLEARLY SPECIFY ALL
 FRAMING MEMBERS AND CONNECTORS. PROVIDE COMPLETE
 LANDING FRAMING PLAN. PROVIDE EXTERIOR SECTION DETAIL
 THAT MATCHES ACTUAL CONSTRUCTION. THERE ARE NO
 CONNECTIONS TO FLOOR TRUSSES. SPECIFY ALL CONNECTIONS
 AT TOP AND BOTTOM OF STAIRS. SEC. R301 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR ALL SIMPSON STRUCTURAL
 CONNECTORS SPECIFIED ON THE DETAILS. PROVIDE ONLY THE
 FLORIDA PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING
 THE SPECIFIED CONNECTOR OR DESIGNER OF RECORD TO
 SPECIFY THE FLORIDA PRODUCT APPROVAL NEXT TO EACH
 SPECIFIED CONNECTOR.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2016-02-10 Cont ID  
Sent By jgomez Date 2016-02-10 Time 16:00 Rev Time 0.00
Received By jgomez Date   Time   Sent To  
Notes
2016-02-10 16:01:17NO REVIEW DONE. NO ELECTRICAL, MECHANICAL OR PLUMBING
 WORK SHOWN. SEE CONTRACTOR'S RESPONSE LETTER. JG.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-12-23 Cont ID  
Sent By mvaldes Date 2015-12-23 Time 18:38 Rev Time 0.00
Received By mvaldes Date 2015-12-23 Time 18:37 Sent To  
Notes
2015-12-23 18:39:311ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE
 SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-02-25 Cont ID  
Sent By fmittner Date 2016-02-25 Time 10:52 Rev Time 0.00
Received By fmittner Date 2016-02-25 Time 10:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-02-25 Cont ID  
Sent By mvaldes Date 2016-02-25 Time 16:36 Rev Time 0.00
Received By mvaldes Date 2016-01-27 Time 13:51 Sent To  
Notes
2016-01-28 13:51:53R26

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-01-06 Cont ID  
Sent By gjohnson Date 2016-01-06 Time 16:18 Rev Time 0.00
Received By gjohnson Date 2016-01-06 Time 16:18 Sent To  
Notes
2016-01-05 12:06:41REAR STRUCTURE RE-SUBMITTAL SUBMITTED ON 12/14/15. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-12-28 Cont ID  
Sent By cpuell Date 2015-12-28 Time 09:16 Rev Time 0.00
Received By cpuell Date 2015-10-06 Time 16:40 Sent To  
Notes
2015-12-14 14:57:08R22
2015-10-06 16:40:11R18 TRAVELLING WITH 15100156

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2016-02-10 Cont ID  
Sent By jgomez Date 2016-02-10 Time 16:02 Rev Time 0.00
Received By jgomez Date 2016-02-10 Time 16:02 Sent To  
Notes
2016-02-10 16:03:58NO ELECTRICAL, MECHANICAL OR PLUMBING WORK SHOWN. SEE
 CONTRACTOR'S RESPONSE LETTER. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2015-11-09 Cont ID  
Sent By jgomez Date 2015-11-09 Time 17:52 Rev Time 0.00
Received By jgomez Date 2015-11-09 Time 17:52 Sent To  
Notes
2015-11-09 17:53:12NO MECHANICAL WORK SHOWN. JG.

Review Stop P PLUMBING
Rev No 4 Status N Date 2016-02-10 Cont ID  
Sent By jgomez Date 2016-02-10 Time 16:03 Rev Time 0.00
Received By jgomez Date 2016-02-10 Time 16:03 Sent To  
Notes
2016-02-10 16:03:30NO ELECTRICAL, MECHANICAL OR PLUMBING WORK SHOWN. SEE
 CONTRACTOR'S RESPONSE LETTER. JG.

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-02-01 Cont ID  
Sent By tklarge Date 2016-02-01 Time 06:47 Rev Time 0.00
Received By tklarge Date 2016-02-01 Time 06:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-01-06 Cont ID  
Sent By gjohnson Date 2016-01-06 Time 15:59 Rev Time 0.00
Received By gjohnson Date 2016-01-06 Time 15:59 Sent To  
Notes
2016-01-06 16:18:342ND REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS; 2ND REQUEST
 1. TWO SETS OF PLANS SHOWING LOCATION OF EXISTING
 FIXTURES AND DETAILED SCOPE OF WORK.
 PER WPB AMEND SEC 107.2.1
 2. VALUATION OF JOB SEEMS LOW PLEASE PROVIDE DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE)
 PER WPB AMEND TOFBC SEC109.3
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-10-14 Cont ID  
Sent By gjohnson Date 2015-10-14 Time 15:31 Rev Time 0.00
Received By gjohnson Date 2015-10-14 Time 15:31 Sent To  
Notes
2015-10-14 15:51:181ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
  
 1.PLEASE PROVIDE DETAILED SCOPE OF WORK ON PLAN FOR
 EACH BUILDING.
 PER WPB AMEND. TO FBC SEC 107.2.1
 2. VALUATION OF JOB SEEMS LOW PLEASE PROVIDE DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS.
 PER.WPB AMEND.TO FBC SEC109.3 BUILDING PERMIT
 VALUATIONS. IF, IN THE OPINION OF THE BUILDING
 OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW
 DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL
 BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE
 LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION
 COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.),
 AS PUBLISHED BY INTERNATIONAL CODE CONGRESS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.

Review Stop Z ZONING
Rev No 3 Status P Date 2016-02-25 Cont ID  
Sent By fmittner Date 2016-02-25 Time 10:52 Rev Time 0.00
Received By fmittner Date 2016-02-25 Time 10:52 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2016-01-06 Cont ID  
Sent By sgraham Date 2016-01-06 Time 09:29 Rev Time 0.00
Received By sgraham Date 2016-01-06 Time 09:28 Sent To  
Notes
2016-01-06 09:31:131/6/16 ZONING FAILED
  
 1.SUBMIT COMPLETE PLANS FOR THE REAR BUILDING
 2. TWO COPIES OF THE PLANS ARE REQUIRED, ONLY ONE SET
 SUBMITTED

Review Stop Z ZONING
Rev No 1 Status F Date 2015-11-10 Cont ID  
Sent By sgraham Date 2015-11-10 Time 09:15 Rev Time  
Received By sgraham Date   Time   Sent To  
Notes
2015-11-10 09:16:2511/10/15 ZONING FAILED
  
 1. SUBMIT COMPLETE PLANS SHOWING ALL WORK ON REAR
 BUILDING.