Plan Review Stops For Permit 15100156 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-02-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-02-10 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-02-10 |
Time |
07:48 |
Sent To |
|
|
Notes |
2016-02-10 07:52:02 | HOUSE IS A CONTRIBUTING HISTORIC HOUSE. EXEMPT FROM | | ENERGY CODE. | | NOTE: FOR SOME REASON THIS HOUSE WAS NOT FLAGGED IN THE | | CITY SYSTEM AS BEING IN THE HISTORIC DISTRICT. I | | FLAGGED THE HOUSE TO AVOID CONFLICTS IN THE FUTURE. JG. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-02-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-02-08 |
Time |
17:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-02-08 |
Time |
17:30 |
Sent To |
|
|
Notes |
2016-02-08 17:48:26 | RESIDENTIAL (R3) MAIN HOUSE ALTERATION THIRD BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH | | EDITION (2014). | | RESPONSE: REPEAT COMMENT. THREE TIMES. A/C EQUIPMENT | | SIZING CALCULATIONS WERE SUBMITTED. NOT ENERGY | | CALCULATIONS WERE SUBMITTED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-01-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-01-05 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-01-05 |
Time |
07:22 |
Sent To |
|
|
Notes |
2016-01-05 07:56:46 | RESIDENTIAL (R3) MAIN HOUSE ALTERATION SECOND BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PLANS SUBMITTED ARE NOT ELECTRONICALLY TRANSMITTED | | PLANS. ENGINEER NEEDS TO PROVIDE ORIGINAL SEAL AND | | SIGNATURE ON ALL PLANS AS REQUIRED BY 61G15-23.002 AND | | CHAPTER 471 F.S. | | RESPONSE: ONLY ONE SET OF DRAWINGS WAS SUBMITTED. NEED | | TO PROVIDE TWO COMPLETE SETS OF PLANS. SEC. 107.1 CITY | | AMENDMENTS. | | | | 2- REVISED DRAWINGS SHOW CLOUDS WITH A DARK BACKGROUND | | ON ALL THE REVISED INFORMATION. DARK BACKGROUND ON THE | | CLOUDS WILL NOT ALLOW THE INFORMATION TO BE READ WHEN | | THE DRAWINGS ARE SCANNED. PLEASE RE-SUBMIT DRAWINGS | | WITHOUT THE DARK BACKGROUND ON THE CLOUDS. DRAWINGS | | NEED TO BE CLEAR FOR RECORD RETENTION PURPOSES. SEC. | | 107.2.1.4 CITY AMENDMENTS. | | | | 3- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | 4- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH | | EDITION (2014). | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. A/C EQUIPMENT | | SIZING CALCULATIONS WERE SUBMITTED. NOT ENERGY | | CALCULATIONS WERE SUBMITTED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-11-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-11-06 |
Time |
18:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-11-06 |
Time |
18:37 |
Sent To |
|
|
Notes |
2015-11-06 18:48:41 | RESIDENTIAL (R3) MAIN HOUSE ALTERATION BUILDING REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PLANS SUBMITTED ARE NOT ELECTRONICALLY TRANSMITTED | | PLANS. ENGINEER NEEDS TO PROVIDE ORIGINAL SEAL AND | | SIGNATURE ON ALL PLANS AS REQUIRED BY 61G15-23.002 AND | | CHAPTER 471 F.S. | | | | 2- PROJECT LOCATION SHOWN ON ALL DRAWINGS IS INCORRECT. | | PROJECT IS LOCATED IN THE CITY OF WEST PALM BEACH NOT | | PALM BEACH. THEY ARE TWO DIFFERENT MUNICIPALITIES. | | REVISE TITLE BLOCK IN ALL DRAWING AS REQUIRED. SEC. | | 107.2.1 CITY AMENDMENTS. | | | | 3- SCOPE OF WORK IS NOT CLEAR. SEC. 107.2.1 CITY | | AMENDMENTS. PLANS DON'T SHOW WHAT'S IS EXISTING AND | | WHAT IS THE PROPOSED SCOPE OF WORK. ACCORDING TO PALM | | BEACH COUNTY PROPERTY THERE IS AN ENCLOSED PORCH IN THE | | REAR OF THE HOUSE AND AN ENCLOSED PORCH IN THE FRONT OF | | THE HOUSE. THERE ARE NO CITY RECORDS FOR THE CONVERSION | | OF ENCLOSED PORCHES TO LIVING SPACES. PLANS SUBMITTED | | SHOW NO ENCLOSED PORCHES BUT LIVABLE SPACE THROUGHOUT | | ENTIRE FIRST FLOOR. WALL LEGEND ON SHEET A2.00 IS NOT | | CLEAR. IT DOESN'T SPECIFY TYPE OF FRAMING WALLS AND | | SPACING. ARE ALL THE WALLS NEW WALLS?. ALSO, CLEARLY | | IDENTIFY ALL ROOMS SHOWN ON THE PROPOSED FIRST FLOOR | | PLAN. | | NOTE: IT LOOKS LIKE THERE WAS ANOTHER PERMIT ISSUED | | JUST FOR THE WINDOWS AND DOORS REPLACEMENT.. TO AVOID | | CONFLICTS OR DELAYS, PLANS SUBMITTED TO PROVIDE ONLY | | THE INFORMATION PERTAINING TO THE SCOPE OF WORK FOR | | WHICH THIS PERMIT APPLICATION WAS SUBMITTED. | | | | 4- ARE THE STAIRS AND HANDRAILS NEW?. WHERE IS THE | | STAIR SECTION DETAIL ON SHEET S1.00 AS SPECIFIED ON THE | | FIRST FLOOR PLAN ON SHEET A2.00. IF NEW STAIRS AND | | HANDRAILS PROVIDE COMPLETE DETAILS AND SPECIFICATIONS | | SHOWING COMPLIANCE WITH THE LIVE LOADS OF TABLE R301.5 | | AND ALL THE SPECIFICATIONS OF SEC. R311.7 AND SEC. R312 | | OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 5- VALUATION IS TOO LOW FOR ALL THE REQUIRED SCOPE OF | | WORK. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. . PROVIDE COPIES OF SIGNED CONTRACTS FOR | | CONTRACTOR'S FEES AND FOR DESIGN PROFESSIONAL FEES. | | | | 6- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. | | | | 7- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH | | EDITION (2014). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] | 2015-10-23 08:39:10 | 10/22/15 ZONING APPROVED FOR THE FRONT HOUSE ONLY, NO | | PLANS INSCLUDED FOR THE REAR BUILDING. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-03-14 |
Time |
18:07 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-03-14 |
Time |
18:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2016-02-25 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-02-25 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-02-25 |
Time |
15:04 |
Sent To |
|
|
Notes |
2016-02-25 15:07:32 | 3RD REVIEW 2014 5TH FBC ED. NEC 2011/RESIDENTIAL | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6713 | | [email protected] | | | | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | 1 PLEASE CLARIFY THE INTENT OF HOW SE CABLE IS BEING | | RAN FOR 2 MAJOR REASONS ONE IS THE TERMINATIONS OF | | ALUMINUM CONDUCTORS INTO THE EQUIPMENT LUGS NEC 110.14 | | A & THE OTHER IS THE THERMAL INSULATION TEMPERATURE | | LIMITATION TO THE 60 DEGREE COLUMN NEC 338. | | 2 PROVIDE AN INTERSYSTEM BONDING STRIP NEC 250.94 | | 3 PROVIDE SERVICE ENTRANCE CONDUCTORS SIZES TO MEET | | LOAD DEMANDS ALSO STATE IF SERVICE EQUIPMENT HAS A MAIN | | DISCONNECT. NEC 230, | | 4 IN BATHROOMS GFCI MUST BE WITHIN 3 FT OF EACH OUTSIDE | | EDGE BASIN. NEC 210.52 D (DOUBLE SINKS REQUIRE EITHER 2 | | ON EACH SIDE OR 1 IN THE MIDDLE TO BE COMPLIANT.) | | 5 SHOW PANEL LOCATIONS ON ELECTRICAL FLOOR PLAN AS WELL | | AS WH & AC DISCONNECTS. WBA 107 | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | MENTIONED DEFICIENCIES. | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-12-23 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2015-12-23 |
Time |
18:42 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2015-12-23 |
Time |
18:42 |
Sent To |
B |
|
Notes |
2015-12-23 18:58:08 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6700 | | [email protected] | | ALTERNATE CONTACT | | MIKE ALBARRAN | | 561-805-6746 | | [email protected] | | | | | | PROVIDE 2 SETS OF PLANS AS REQUIRED BY CITY OF WEST | | PALM BEACH FBC 107 | | PROPERLY LABEL EACH AREA AND PROVIDE SCOPE OF WORK PER | | CWPB FBC 107 | | SHOW SERVICE LOCATION ON FLOOR PLANS AND SHOW PROPER | | GROUNDING AND BONDING ON RISER , NEC 250.53 WATER/METAL | | PIPE , NEC 250.94 INTERSYSTEM. | | SHOW HOW SE CABLE IS BEING RAN AS YOUR FEEDER | | CONDUCTORS NEC 338 | | TAMPER RESISTANT RECEPTACLES REQUIRED PER NEC 406.11 | | R404.1 LIGHTING EQUIPMENT (MANDATORY). | | A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY | | INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY | | LAMPS OR A MINIMUM OF 75 PERCENT OF THE PERMANENTLY | | INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH | | EFFICACY LAMPS. | | R402.4.4 RECESSED LIGHTING. | | RECESSED LUMINAIRES INSTALLED IN THE BUILDING THERMAL | | ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN | | CONDITIONED AND UNCONDITIONED SPACES. ALL RECESSED | | LUMINAIRES SHALL BE IC-RATED AND LABELED AS HAVING AN | | AIR LEAKAGE RATE NOT MORE THAN 2.0 CFM (0.944 L/S) WHEN | | TESTED IN ACCORDANCE WITH ASTM E 283 AT A 1.57 PSF (75 | | PA) PRESSURE DIFFERENTIAL. ALL RECESSED LUMINAIRES | | SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE | | HOUSING AND THE INTERIOR WALL OR CEILING COVERING. | | ALL RECESSED LIGHTING OVER SHOWER OR BATHTUB SHALL BE | | VAPOR TIGHT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2015-11-05 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2015-11-05 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2016-02-25 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-02-25 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-02-25 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-03-14 |
Time |
18:08 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-03-14 |
Time |
12:38 |
Sent To |
|
|
Notes |
2016-03-14 12:38:12 | RESUB ROUTED TO MVALDES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-02-25 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-02-25 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-01-27 |
Time |
17:53 |
Sent To |
|
|
Notes |
2016-02-08 17:54:24 | RE-SUBMITTAL SENT TO R26 SHELF. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-01-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-01-05 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-12-14 |
Time |
14:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-11-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-11-09 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-10-06 |
Time |
18:39 |
Sent To |
|
|
Notes |
2015-10-06 16:39:07 | R18 TRAVELLING WITH 15100158 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2016-02-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-02-08 |
Time |
17:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-02-08 |
Time |
17:48 |
Sent To |
|
|
Notes |
2016-02-08 17:49:51 | NO IMPACT FEES DUE. MU-2016-1989. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2016-01-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-01-05 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-01-05 |
Time |
14:21 |
Sent To |
|
|
Notes |
2016-01-05 14:22:02 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-11-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-11-09 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-11-09 |
Time |
11:33 |
Sent To |
|
|
Notes |
2015-11-09 11:35:38 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2016-02-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-02-10 |
Time |
18:36 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-02-10 |
Time |
08:20 |
Sent To |
|
|
Notes |
2016-02-08 18:45:41 | MECHANICAL REVIEW APPROVED WITH PROVISO: | | | | 1- PROVIDE SIZE OF TRANSFER GRILL SHOWN ON THE SECOND | | FLOOR FOR ALL THE BEDROOMS. SEC. M1602.4 OF | | FBC-RESIDENTIAL, 5TH EDITION (2014). |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-01-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-01-05 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-01-05 |
Time |
14:06 |
Sent To |
|
|
Notes |
2016-01-05 14:10:28 | RESIDENTIAL (R3) ALTERATION SECOND MECHANICAL REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | NOTE; | | THE COMMENTS BELOW ARE THE EXACT SAME COMMENTS FROM | | FIRST CHECKLIST. COMMENTS WERE NOT ADDRESSED. | | | | 1- THERE IS NO COORDINATION WITH EQUIPMENT SIZING | | CALCULATIONS AND FLOOR PLAN ON SHEET M1.00 SUBMITTED. | | SHEET M1.00 SHOWS ONLY ONE A/C UNIT. EQUIPMENT. ALSO, | | EQUIPMENT LISTED ON THE A/C PLAN DOESN'T MATCH | | EQUIPMENT SIZING CALCULATIONS. PROVIDE EQUIPMENT SIZING | | CALCULATIONS THAT MATCH A/C PLAN. SEC. 107.2.. 1 CITY | | AMENDMENTS. | | | | 2- CONDENSING UNIT MOUNTING DETAIL SHOWN ON SHEET M1.00 | | IS INCOMPLETE. (4) 2 1/4" TAPCONS IS NOT ENOUGH | | INFORMATION TO SHOW HOW THE CONDENSING UNIT IS | | SUPPORTED TO RESIST THE WIND LOADS. PROVIDE | | CLARIFICATION WHY THERE ARE NOT HURRICANE STRAPS OR | | HURRICANE CLIPS USED AND PROVIDE ENGINEERING | | CALCULATIONS SHOWING HOW ONLY THE SPECIFIED TAPCONS | | WILL MEET THE WIND LOADS AS REQUIRED BY SEC. R301 OF | | FBC-RESIDENTIAL, 5TH EDITION (2014). PROVIDE CLEAR AND | | COMPLETE DETAILS AND SPECIFICATIONS SHOWING HOW THE | | CONDENSING UNIT IS ATTACHED TO THE CONDENSER PAD. | | CLEARLY SPECIFY LOCATION OF ALL TAPCONS AND PROVIDE | | COMPLETE SPECIFICATIONS FOR THE CONDENSER PAD. | | | | 3- DRAWING M1.00 : PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING COMPLIANCE WITH THE RETURN AIR | | SEC. M1602 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | SPECIFY SIZE OF GRILL SHOWN ON THE FIRST FLOOR AND | | SECOND FLOOR AND SPECIFY HOW ARE THE RETURN GRILLS | | CONNECTED TO THE AIR HANDLER UNIT. | | | | 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING | | COMPLIANCE WITH THE BALANCED RETURN AIR SEC. M1602.4 OF | | FBC-RESIDENTIAL, 5TH EDITION (2014) FOR ALL THE | | BEDROOMS ON THE SECOND FLOOR. | | | | 5- PLANS SUBMITTED ARE NOT ELECTRONICALLY TRANSMITTED | | PLANS. ENGINEER NEEDS TO PROVIDE ORIGINAL SEAL AND | | SIGNATURE ON ALL PLANS AS REQUIRED BY 61G15-23.002 AND | | CHAPTER 471 F.S. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-11-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-11-09 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-11-09 |
Time |
07:42 |
Sent To |
|
|
Notes |
2015-11-09 16:30:59 | RESIDENTIAL (R3) ALTERATION MECHANICAL REVIEW COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- THERE IS NO COORDINATION WITH EQUIPMENT SIZING | | CALCULATIONS AND FLOOR PLAN ON SHEET M1.00 SUBMITTED. | | SHEET M1.00 SHOWS ONLY ONE A/C UNIT. EQUIPMENT. ALSO, | | EQUIPMENT LISTED ON THE A/C PLAN DOESN'T MATCH | | EQUIPMENT SIZING CALCULATIONS. PROVIDE EQUIPMENT SIZING | | CALCULATIONS THAT MATCH A/C PLAN. SEC. 107.2.. 1 CITY | | AMENDMENTS. | | | | 2- CONDENSING UNIT MOUNTING DETAIL SHOWN ON SHEET M1.00 | | IS INADEQUATE. (4) 2 1/4" TAPCONS ARE NOT ENOUGH | | SPECIFICATIONS TO HOLD THE CONDENSING UNIT. PROVIDE A | | COMPLETE DETAILS AND SPECIFICATIONS SHOWING HOW IS THE | | CONDENSING UNIT ATTACHED TO RESIST THE WIND LOADS OF | | SEC. R301 OF FBC-RESIDENTIAL. | | AND, CLEARLY SPECIFY LOCATION OF ALL CONNECTORS. | | | | 3- DRAWING M1.00 : PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING COMPLIANCE WITH THE RETURN AIR | | SEC. M1602 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | SPECIFY SIZE OF GRILL SHOWN ON THE FIRST FLOOR AND | | SECOND FLOOR AND SPECIFY HOW ARE THE RETURN GRILLS | | CONNECTED TO THE AIR HANDLER UNIT. | | | | 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING | | COMPLIANCE WITH THE BALANCED RETURN AIR SEC. M1602.4 OF | | FBC-RESIDENTIAL, 5TH EDITION (2014) FOR ALL THE | | BEDROOMS ON THE SECOND FLOOR. | | | | 5- PLANS SUBMITTED ARE NOT ELECTRONICALLY TRANSMITTED | | PLANS. ENGINEER NEEDS TO PROVIDE ORIGINAL SEAL AND | | SIGNATURE ON ALL PLANS AS REQUIRED BY 61G15-23.002 AND | | CHAPTER 471 F.S. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-02-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-02-10 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-02-10 |
Time |
16:18 |
Sent To |
|
|
Notes |
2016-02-10 16:19:21 | PLANS APPROVED BY TIM LARGE. SEE PLANS. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-12-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-12-20 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-12-20 |
Time |
10:58 |
Sent To |
|
|
Notes |
2015-12-20 11:14:59 | 1) ONE SET OF PLANS IS INCOMPLETE. SHTS.M1.00, P1.00 & | | S1.00 ARE MISSING FROM ONE SET. SUBMIT 2 COMPLETE SETS | | OF PLANS FOR REVIEW. WPB AMEND. TO FBC SEC. 107.1. | | 2) SUBMIT 2 SETS OF PLANS FOR WORK BEING DONE FOR BOTH | | PROPERTIES AND IDENTIFY ON THE PLANS WHICH IS THE FRONT | | AND WHICH IS THE REAR STRUCTURE.WPB AMEND. TO FBC SEC. | | 107.1. | | 3) CLEARLY SHOW THE EXTENT OF PLUMBING WORK TO BE DONE. | | INDICATE ON THE PLAN WHAT IS EXISTING TO REMAIN AND | | WHAT IS EXISTING TO BE REPLACED. WPB AMEND. TO FBC SEC. | | 107.1. | | 4) A SANITARY RISER HAS BEEN SUBMITTED. INDICATE ON THE | | PLANS IF ANY OF THE EXISTING SANITARY PIPING SYSTEM IS | | BEING REPLACED OR HAS THE RISER BEEN SUBMITTED FOR | | REFERENCE ONLY.WPB AMEND. TO FBC SEC. 107.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-10-14 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-10-14 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-10-14 |
Time |
15:52 |
Sent To |
|
|
Notes |
2015-10-14 15:56:39 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | | | | | 1.PLEASE PROVIDE DETAILED SCOPE OF WORK ON PLAN. | | PER WPB AMEND TO FBC SEC 107.2.1 | | 2.A COMPREHENSIVE REVIEW CAN NOT BE COMPLETED AT THIS | | TIME ADDITIONAL COMMENTS MAYBE GENERATED ON 2ND REVIEW. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2016-02-25 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-02-25 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-02-25 |
Time |
10:51 |
Sent To |
E |
|
Notes |
2016-02-08 17:54:58 | NEW PLANS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-12-17 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-12-17 |
Time |
10:52 |
Sent To |
|
|
Notes |
2015-12-17 10:53:52 | 12/17/15 ZONING APPROVED FOR FRONT HOUSE ONLY, NO PLANS | | TO SHOW WORK IN THE REAR BUILDING. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-10-22 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-10-22 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-10-22 |
Time |
15:35 |
Sent To |
|
|
Notes |
2015-10-22 15:37:00 | 10/22/15 ZONING REVIEWED FRONT HOUSE ONLY,NO PLANS FOR | | REAR BUILDING. THE PLANS MUST BE REVISED TO REMOVE THE | | DOORS TO THE STAIRS AND THE LIVING ROOM. MOTHER-IN-LAW | | SUITE MUST BE REMOVED FROM THE | | PLANS, CAN NOT USE THE ROOM AS AN APARTMENT. |
|
|