2015-10-28 10:16:49 | PERMIT # 15100130 |
| REVIEW COMMENTS - FIRE DEPARTMENT |
| |
| PLAN REVIEW OF THIS EVENT APPROVED. |
| |
| CANDLES ARE SAFE PRODUCTS, BUT UNLESS THEY ARE USED |
| SAFELY AND WATCHED CAREFULLY, THEY CAN LEAD TO AN |
| ACCIDENTAL FIRE. MOST FIRES INVOLVING CANDLES ARE DUE |
| TO INATTENTION TO BASIC FIRE SAFETY OR THE MISUSE. THE |
| WEST PALM BEACH BUREAU OF FIRE PREVENTION REMINDS THE |
| COMMUNITY THAT A CANDLE IS AN OPEN FLAME THAT CAN |
| EASILY IGNITE ANYTHING THAT CAN BURN, AND AS SUCH |
| STRONGLY ENCOURAGES AND RECOMMENDS THE USE OF |
| ELECTRONIC CANDLES IN ALL INSTANCES. |
| |
| NFPA 1, LIFE SAFETY CODE, 10.1.6, STATES THAT THE AHJ |
| SHALL HAVE THE AUTHORITY TO PROHIBIT ANY OR ALL OPEN |
| FLAMES OR OTHER SOURCE OF IGNITION WHERE CIRCUMSTANCES |
| MAKE SUCH CONDITIONS HAZARDOUS. |
| |
| THE FOLLOWING SUGGESTIONS FOR OPEN FLAME CANDLE USE ARE |
| BEING MADE BY THE BUREAU OF FIRE PREVENTION. |
| 1. CANDLE HOLDERS SHALL BE WIDER THAN THE CANDLE, AND |
| CAPABLE OF COLLECTING ANY AND ALL DRIPPINGS. |
| 2. TO PREVENT OVERTURNING, THE ASSEMBLY BASE OR CANDLE |
| HOLDER MUST BE A STABLE DESIGN THAT WILL RETURN TO THE |
| UPRIGHT POSITION IF TILTED TO AN ANGLE OF 45 DEGREES. |
| (BOTTOM WEIGHTED AS OPPOSED TO TOP HEAVY) |
| 3. THE FLAME TIP SHALL BE A MINIMUM OF 1 INCH BELOW THE |
| RIM OF THE ENCLOSURE. WICKS SHALL BE TRIMMED TO ? INCH |
| OR LESS BEFORE USE. |
| 4. ARTIFICIAL DECORATIVE FLOWERS AND ARTIFICIAL |
| DECORATIVE VEGETATION MAY BE PART OF A CANDLE ASSEMBLY |
| BUT SHALL BE FLAME RESISTANT OR FLAME RETARDANT. SUCH |
| MATERIALS SHALL NOT BE DIRECTLY ATTACHED TO THE CANDLE |
| NOR ARRANGED SO THE MATERIAL CAN COME IN CONTACT WITH |
| THE FLAME. |
| 5. CANDLE ASSEMBLIES SHALL BE KEPT A MINIMUM OF 12 |
| INCHES FROM OTHER COMBUSTIBLE MATERIALS NEARBY TO |
| PREVENT ACCIDENTAL CONTACT. |
| 6. CANDLE ASSEMBLIES SHOULD BE PLACED ONLY WHERE |
| APPROVED FOR USE. AFTER USE, CANDLES SHALL BE |
| EXTINGUISHED AND ALLOWED TO COOL AND SHALL BE PROPERLY |
| STORED OR DISCARDED. |
| 7. CANDLES SHALL BE A MINIMUM DISTANCE FROM ANOTHER |
| CANDLE SO THAT THEY DO NOT TOUCH IN THE EVENT THAT THEY |
| ARE PUSHED / KNOCKED OVER. |
| 8. NO GEL, OR HOME-MADE CANDLES / NO FLOOR STANDING |
| CANDELABRAS OR ASSEMBLIES. |
| 9. NO PLACEMENT OF CANDLE OR CANDLE ASSEMBLIES IN ANY |
| AISLE, EXIT ACCESS, OR EXIT. |
| 10. NO DRIED FLOWER OR SIMILAR DRIED VEGETATION SHALL |
| BE INCORPORATED IN OR NEAR ANY CANDLE ASSEMBLY. |
| 11. NO PAPER, PLASTIC OR SIMILARLY COMBUSTIBLE TABLE |
| COVERINGS ARE ALLOWED. |
| 12. CANDLES SHOULD BE PLACED IN SUCH A MANNER THAT |
| ACCIDENTAL CONTACT WITH THEM IS PREVENTED. (IE. AWAY |
| FROM TABLE EDGES, NOT ALONG HEAVY TRAFFIC WALKWAYS, |
| EASILY REACHED BY CHILDREN, ETC...) |
| |
| |
| SUE ELLEN CALDERON |
| ASST. FIRE MARSHAL |
| OFFICE OF THE FIRE MARSHAL |
| WEST PALM BEACH FIRE RESCUE |
| [email protected] |
| (561) 804-4751 |
| |