Plan Review Stops For Permit 15100085 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-12-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-12-16 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-12-16 |
Time |
15:28 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-11-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-25 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-11-25 |
Time |
10:37 |
Sent To |
|
|
Notes |
2015-11-25 10:40:10 | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | PROVIDE DETAIL OF WALL CONSTRUCTION AND ANCHOR | | EMBEDDMENT. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
2015-11-01 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-01 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-01 |
Time |
13:16 |
Sent To |
|
|
Notes |
2015-11-01 13:21:11 | FBC 2014 5TH ED. | | | | NO FULL REVIEW PERFORMED AS ZONING COMMENT RESULTS IN | | AN ALTERNATE DESIGN REQUIRED. | | | | IT APPEARS THE VALUE IS LOW. | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | PLEASE CLEARLY SPECIFY THE ANCHOR LOCATIONS. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-12-16 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2015-12-16 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2015-12-16 |
Time |
15:33 |
Sent To |
|
|
Notes |
2015-12-16 15:35:41 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6700 | | [email protected] | | ALTERNATE CONTACT | | MIKE ALBARRAN | | 561-805-6746 | | [email protected] | | | | | | *OR ASTRONOMICAL TIME SWICTH. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-11-25 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-25 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-25 |
Time |
10:35 |
Sent To |
|
|
Notes |
2015-11-25 10:44:15 | 2ND REVIEW FBC 2014 5TH ED. NEC2011 | | | | PLEASE CLEARLY SHOW COMPLIANCE WITH FBC-EC 405.2.4 | | ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC-EC 405.2.4 | | SHALL HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT | | OR WHEN NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR & | | TIME CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME | | SWITCHES SHALL BE CAPABLE OF RETAINING PROGRAMING | | DURING A LOSS OF POWER FOR A MINIMUM OF 10 HOURS. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2015-11-01 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-01 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-01 |
Time |
13:17 |
Sent To |
|
|
Notes |
2015-11-01 13:23:28 | FBC 2014 5TH ED. NEC2011 | | | | NO FULL REVIEW PERFORMED AS ZONING COMMENT RESULTS IN | | AN ALTERNATE DESIGN REQUIRED. | | | | PLEASE CLEARLY COMPLIANCE WITH FBC 505.1 | | ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 505.1 SHALL | | HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT OR WHEN | | NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR & TIME | | CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME SWITCHES | | SHALL BE CAPABLE OF RETAINING PROGRAMING DURING A LOSS | | OF POWER FOR A MINIMUM OF 10 HOURS. FBC-E 505.2.4 | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2015-12-11 |
Time |
09:22 |
Sent To |
Z |
|
Notes |
2015-12-15 18:09:07 | TO MISC 2 BOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-11-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-25 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2015-11-06 |
Time |
12:01 |
Sent To |
Z |
|
Notes |
2015-11-17 09:20:46 | TO MISC 2 BOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-11-01 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-01 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-05 |
Time |
11:21 |
Sent To |
|
|
Notes |
2015-10-08 14:49:32 | TO SAK DESK | 2015-10-08 10:00:09 | TO MISC 2 BOX. | 2015-10-05 11:21:50 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2015-12-15 |
Time |
18:08 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2015-12-15 |
Time |
18:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-11-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2015-11-25 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2015-11-17 |
Time |
09:20 |
Sent To |
|
|
Notes |
2015-11-17 09:20:30 | CHANNEL LETTERS |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-10-08 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2015-10-08 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2015-10-08 |
Time |
09:58 |
Sent To |
|
|
Notes |
2015-10-08 09:59:48 | INTERNALLY ILLUMINATED CABINETS ARE NOT PERMITTED IN | | THE DMP. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|