Plan Review Details - Permit 15100067
Plan Review Stops For Permit 15100067
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-03-30 Cont ID  
Sent By shill Date 2016-03-30 Time 12:09 Rev Time 0.00
Received By shill Date 2016-03-30 Time 12:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-12-05 Cont ID  
Sent By shill Date 2015-12-05 Time 12:28 Rev Time 0.00
Received By shill Date 2015-12-05 Time 12:28 Sent To  
Notes
2015-12-05 12:29:01****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 PLEASE ADVISE WHEN THE SIGNATURE DOCUMENTS FOR 14120908
 AND 14120909 HAVE BEEN SUBMITTED AND APPROVED.
  
 THIS MAY BE DONE VIA EMAIL. NO RESUBMITTAL IS
 NECESSARY. AFTER SIGNATURE DOCUMENTS HAVE BEEN
 APPROVED, BUILDING REVISION REVIEW STATUS WILL BE
 CHANGED FROM "F" TO "P".
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-09 Cont ID  
Sent By shill Date 2015-11-09 Time 14:37 Rev Time 0.00
Received By shill Date 2015-11-09 Time 07:57 Sent To  
Notes
2015-11-09 14:37:27****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. G101, INCORPORATE THE INFORMATION IN THE RESPONSE
 LETTER REGARING THE PERCENTAGE OF OPENINGS FOR EACH
 WALL INTO THE PLAN IN ORDER TO SHOW COMPLIANCE WITH FBC
 TABLE 705.8.
  
 CHANGES TO THE PROPERTY LINE (REPLAT) REQUIRE THAT
 COMPLIANCE WITH FBC TABLE 705.8 (MAXIMUM AREA OF
 EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION
 DISTANCE) AND FBC TABLE 602 (FIRE RESISTANCE RATING
 REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE
 SEPARATION DISTANCE) BE SHOWN.
  
 ONLY EAST FACING NEW WALLS WERE ADDRESSED IN THE
 RESPONSE LETTER AND SHOW THE DISTANCE TO THE NEW
 PROPERTY LINE ON SHEET G101. AS THE PROPERTY LINE IS
 BEING RELOCATED, COMPLIANCE NEEDS TO BE SHOWN FOR THE
 EXISTING WALLS AND THE NEW WALLS WHICH FACE SOUTH.
  
 BASED ON INFORMATION PROVIDED: BEARING WALLS ARE
 REQUIRED TO BE 3 HOURS. STRUCTURAL FRAME IS REQUIRED TO
 BE 2 HOURS. PLAN SHOWS THESE WALLS AS 1 HR; PLEASE SEE
 FBC TABLE 602, FOOTNOTE A AND REVISE.
  
 2. THE ART IN PUBLIC PLACES WAS SENT VIA EMAIL, CITY OF
 WEST PALM BEACH CODE OF ORDINANCES 78-123, 78-126.
  
 THIS REVISION WILL BE ISSUED WITH THE PROVISO THAT, BY
 DEC 23, 2015, THE APPROVAL WILL BE PROVIDED. PLEASE
 SEND A COPY OF THE APPROVAL WHEN AVAILABLE VIA EMAIL TO
 [email protected] IN ORDER TO DOCUMENT THE PERMIT FILE.
  
 3. OK
  
 4. ADVISORY ONLY, PRODUCT APPROVALS REVIEWED BY
 DESIGNER OF RECORD ARE TO BE SUBMITTED FOR REVIEW PRIOR
 TO INSTALLATION IF NOT SUBMITTED AT THIS TIME, FBC 107,
 FBC 1609 (SUBMITTAL, NO FEE).
  
 5. ADVISORY ONLY; PARKING LOT STRIPING, AWNINGS, SIGNS
 AND OTHER INDEPENDENT STRUCTURE ELEMENTS REQUIRE
 SEPARATE PERMITS WHICH WOULD INCLUDE FEES, BUILDING
 PERMIT APPLICATIONS, PLANS AND REVIEWS.
  
 6. ADVISORY ONLY; SPEC SHEETS IN APPENDIX WERE NOT
 REVIEWED.
  
 7. PRIOR TO INSTALLATION, SUBMITTALS FOR THE UL
 ASSEMBLIES WILL BE REQUIRED. THE SUBMITTAL SHOULD
 INCLUDE THE UL ASSEMBLY WITH SPECIFIC OPTIONS ELECTED
 TO BE INDICATED. THE SUBMITTAL IS REQUIRED TO BE
 REVIEWED BY DOR. THE SUBMITTAL IS REQUIRED TO BE
 APPROVED THROUGH PLAN REVIEW PRIOR TO COMMENCEMENT.
  
 8 TO 13. OK
  
 14. RE-PLAT TO BE FILED WITHIN 45 DAYS OF PERMIT
 ISSUANCE (AGREEMENT BETWEEN OWNER AND DEVELOPMENT
 SERVICES).
  
 PLEASE PROVIDE THE PLAT BOOK AND PAGE NUMBER WHEN
 FILED.
  
 15. OK
  
 **NEW COMMENT**
  
 16. SIGNATURE PAGE FOR THE DIGITAL PLANS REQUIRED, OR
 PROVIDE HARDCOPY SIGNED AND SEALED PLANS FOR 14120908
 (PLANS SUBMITTED HAD SOME INCONSISTENCIES WITH THE
 DIGITAL PLANS ISSUED).
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-10-22 Cont ID  
Sent By wjolin Date 2015-10-22 Time 16:13 Rev Time 0.00
Received By wjolin Date 2015-10-22 Time 16:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-14 Cont ID  
Sent By lmarchan Date 2015-12-14 Time 09:46 Rev Time 0.00
Received By lmarchan Date 2015-11-30 Time 11:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-09 Cont ID  
Sent By shill Date 2015-11-09 Time 14:38 Rev Time 0.00
Received By shill Date 2015-10-05 Time 16:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-10-20 Cont ID  
Sent By hmoser Date 2015-10-20 Time 10:58 Rev Time 0.00
Received By ccole Date 2015-10-20 Time 10:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-12-07 Cont ID  
Sent By tklarge Date 2015-12-07 Time 06:12 Rev Time 0.00
Received By tklarge Date 2015-12-07 Time 05:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-10-26 Cont ID  
Sent By tlarge Date 2015-10-26 Time 10:59 Rev Time 0.00
Received By tklarge Date 2015-10-26 Time 05:27 Sent To  
Notes
2015-10-26 09:49:411) SHT.058.1- P401 - NATURAL GAS RISER - SHOW THE
 DISTANCE ( DEVELOPED LENGTH ) FROM THE GPRV-2 TO THE
 273 MBH STEAMER.
 2) SIZE THE WASTE AND VENT LINES FOR THE WATER CLOSET
 WC-1 & LAV-1 ON THE SANITARY RISER FOR MEN'S/WOMENS
 TOILET ROOMS #111/112.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2016-05-26 Cont ID  
Sent By shill Date 2016-05-26 Time 07:40 Rev Time 0.00
Received By shill Date 2016-05-26 Time 07:40 Sent To  
Notes
2016-05-26 07:42:34SEE SUPPORTING LETTER FROM ARCHITECT. A REVISION NUMBER
 WAS CHANGED ON THE SIGNATURE DOCUMENT (BUT, PER
 ARCHITECT, INFORMATION ON THE PLAN/DESIGN DID NOT
 CHANGE) DUE TO THE LENGTH OF TIME FROM PLAN UPLOAD TO
 PROJECTDOX AND ALL DESIGN PROFESSIONALS OBTAINING
 DIGITAL SIGNATURE.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2016-05-21 Cont ID  
Sent By shill Date 2016-05-21 Time 17:19 Rev Time 0.00
Received By shill Date 2016-05-21 Time 17:10 Sent To  
Notes
2016-05-21 17:13:12****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 THE FILE FOR THE DINING EXPANSION REVISION, IN THE
 FOLDER 14120908_PROVISO SUBMISSION 15100067 DOESN'T
 MATCH OUR FILE. FOR EXAMPLE, THERE ARE PLUMBING SHEETS
 IN PROJECTDOX WHICH ARE NOT IN THE SIGNATURE DOCUMENT.
 THERE ARE ELECTRICAL PAGES WHICH ARE ON THE SIGNATURE
 DOCUMENT WHICH ARE NOT IN PROJECTDOX.
  
 A LIST OF THE PLANS IN PROJECTDOX WAS EMAILED TO
 APPLICANT.
  
 IT IS RECOMMENDED THAT APPLICANT COMPARE THE SIGNATURE
 DOCUMENT FILE TO THE PAGES SUBMITTED IN PROJECTDOX
 PRIOR TO RESUBMITTAL.
  
 A REVIEW OF THE OTHER TWO FILES WILL BE DONE AFTER
 APPLICANT CONFIRMS THAT THE PROJECTDOX FILES ARE
 IDENTICAL TO THE SIGNATURE DOCUMENTS.
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-10-29 Cont ID  
Sent By eschneid Date 2015-10-29 Time 10:06 Rev Time 0.75
Received By eschneid Date 2015-10-29 Time 09:57 Sent To  
Notes
2015-10-29 10:06:05PASSED
  
 1) THIS PERMIT REVISION APPROVAL IS ONLY FOR THE DINING
 ROOM EXPANSION, NOT THE OTHER WORK INCLUDED ON THE
 PLANS.
  
 2) SEPARATE PERMITS WITH PLANS ARE REQUIRED FOR:
  
 A. LANDSCAPE
 B. PARKING
 C. SITE WORK
 D. IRRIGATION