Plan Review Stops For Permit 15100028 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2016-08-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-18 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-18 |
Time |
08:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-06-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-17 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-06-06 |
Time |
11:43 |
Sent To |
E |
|
Notes |
2016-06-06 11:44:48 | WAITING ON APPLICANT TO SUBMIT PRODUCT APPROVALS FOR | | WINDOWS AND DOORS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-05-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-05-31 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-05-31 |
Time |
13:47 |
Sent To |
|
|
Notes |
2016-05-31 14:14:14 | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-7918 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 3RD REVIEW | | DATE: 3/31/16 | | ACTION: FAILED | | | | 1. PROVIDE PRODUCT APPROVALS FOR ALL NEW WINDOWS AND | | DOORS SHOWN ON PLANS SUBJECT TO WIND LOADS. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING, | | WINDOW, AND DOOR SUBMITTALS. | | | | 2. THE PLAN APPEARS TO INCLUDE THE CONDITIONING OF A | | 297 SF AREA OF THE RESIDENCE IDENTIFIED AS A DEN BUT ON | | RECORD AS A PORCH. THE PLAN ASSOCIATED WITH THE WINDOW | | REPLACEMENT PERMIT 10060887 COMPLETED IN 2010 DOES NOT | | SHOW THE CONSTRUCTION OF WALLS AND WINDOWS AS | | CONSISTENT WITH THE PROPOSED PLAN. | | | | PROOF OF COMPLIANCE MAY BE REQUIRED FOR PREVIOUSLY | | COMPLETED UN-PERMITTED WORK. | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | TEST REPORTS AS PROOF OF COMPLIANCE. PLEASE BE ADVISED | | THE INSPECTOR MAY REQUIRE PREVIOUSLY COMPLETED WORK TO | | BE MADE ACCESSIBLE AND OPEN FOR INSPECTION OR REQUIRE | | ADDITIONAL DOCUMENTATION FOR ALL CONCEALED WORK | | PREVIOUSLY COMPLETED PURSUANT TO FBC 110 & FBC 117. | | | | 3. MECHANICAL PERMIT MAY BE REQUIRED. | | | | 4. PROVIDE MECHANICAL PLAN TO SHOW SUPPLY DUCTS PER FBC | | - R M16. | | | | 5. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED. | | CONTACT THE PBC IMPACT FEE OFFICE @ 233-5025. UPON | | APPROVAL, YOU MAY CHECK OUT ONE PLAN AND TAKE TO THAT | | OFFICE FOR REVIEW. PLEASE RETURN STAMPED WITH A COPY OF | | RECEIPT AS APPLICABLE. | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-04-05 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-04-05 |
Time |
09:26 |
Sent To |
|
|
Notes |
2016-04-05 10:13:04 | 2ND REVIEW: FBC 2014 5TH ED | | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | 1. VALUE APPEARS LOW. | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | FAILURE TO PROVIDE DOCUMENTATION OF ESTIMATED COSTS MAY | | DELAY THE APPLICATION PROCESS. | | | | 2. PROVIDE ENERGY SUBMITTAL - RESIDENTIAL BUILDING FORM | | R405. | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | (MANDATORY). | | THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY | | PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND | | CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT | | BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY. | | FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)] | | REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN | | ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND | | NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD | | CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE | | LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A | | DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT | | THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE | | BUILDER ACCURATELY REFLECTS THE PLANS AND | | SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE | | FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE | | FOUND IN APPENDIX C. | | | | 3. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED. | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURN STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | 4, PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS. PROVIDE | | EMERGENCY ESCAPE IN MASTER BEDROOM. | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE WINDOW SUBMITTALS. | | FBC-R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED IN | | M-BEDROOM AS FOLLOWS: WHERE EMERGENCY ESCAPE AND RESCUE | | OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF | | NOT MORE THAN 44 INCHES (1118 MM) MEASURED FROM THE | | FINISHED FLOOR TO THE BOTTOM OF THE CLEAR OPENING. | | R310.1.1 MINIMUM OPENING AREA GRADE FLOOR OPENINGS | | SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SQUARE FEET | | R310.1.2 MINIMUM OPENING HEIGHT. | | THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES | | R310.1.3 MINIMUM OPENING WIDTH. | | THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES | | | | 5. PROOF OF COMPLIANCE MAY BE REQUIRED FOR PREVIOUSLY | | COMPLETED UN-PERMITTED WORK. | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | TEST REPORTS AS PROOF OF COMPLIANCE PLEASE BE ADVISED | | THE INSPECTOR MAY REQUIRE PREVIOUSLY COMPLETED WORK TO | | BE MADE ACCESSIBLE AND OPEN FOR INSPECTION OR REQUIRE | | ADDITIONAL DOCUMENTATION FOR ALL CONCEALED WORK | | PREVIOUSLY COMPLETED PURSUANT TO FBC 110 & FBC 117. | | | | 6. REF. DETAIL B-B, PG. A-1. PROVIDE CONNECTION DETAIL | | OF 16" STRAP TO EXISTING CONCRETE BEAM AND EXISTING | | ROOF FRAMING. | | 7. REF. DETAIL A-A, PG. A-1. PROVIDE CONNECTION DETAIL | | FOR 2X8 WOOD FRAMING TO EXISTING CONCRETE BEAM AND TO | | EXISTING CONCRETE SLAB. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-10-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-20 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-20 |
Time |
10:19 |
Sent To |
|
|
Notes |
2015-10-20 10:52:49 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | THE PLAN APPEARS TO PROPOSE CONDITIONING A 297 SF AREA | | OF THE RESIDENCE IDENTIFIED AS A DEN BUT ON RECORD AS A | | PORCH. THE PLAN ASSOCIATED WITH WINDOW REPLACEMENT | | PERMIT 10060887 COMPLETED IN 2010 DOES NOT SHOW THE | | CONSTRUCTION OF WALLS AND WINDOWS AS CONSISTENT WITH | | THE PROPOSED PLAN. | | | | PLEASE PROVIDE INFORMATION AS TO THE EXISTING | | CONSTRUCTION OF THE 27' LONG AND 11' LONG EXTERIOR | | WALLS WHICH ENCLOSE THE 297SF PORCH. INCLUDE THERMAL | | INSULATION INFORMATION FOR THE WALLS AND CEILING. | | ADDITIONALLY PROVIDE AN ENERGY SUBMITTAL. SHOW ALL WORK | | THAT THERE IS NO PERMIT RECORD OF. PLEASE CLARIFY IF | | THERE IS TO BE A DOOR OR OPEN PASS THROUGH FOR THE AREA | | WHERE THE MASTER BEDROOM COMMUNICATES WITH THE PROPOSED | | DEN. PLEASE INDICATE WHAT THE PROPOSED MEANS OF | | EMERGENCY EGRESS IS FOR THE MASTER BEDROOM, IF IT IS | | THE EXISTING WINDOW TAKING THE PLACE OF A FORMER | | EXTERIOR SGD, IT WILL HAVE TO MEET THE REQUIREMENTS FOR | | NEW CONSTRUCTION. | | | | FBC 107.2.1 CONSTRUCTION DOCUMENTS SHALL BE OF | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. | | | | R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. WHERE | | EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY | | SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES. | | R310.1.1 MINIMUM OPENING AREA. | | ALL EMERGENCY ESCAPE GRADE FLOOR OPENINGS SHALL HAVE A | | MINIMUM NET CLEAR OPENING OF 5 SQUARE FEET | | R310.1.2 MINIMUM OPENING HEIGHT. | | THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | THE CLAIMED VALUE APPEARS TO BE LOW FOR THE WORK | | PROPOSED AND ESPECIALLY AS THE RECORD DOES NOT | | DEMONSTRATE POSSIBLE PREVIOUS WORK TO ENCLOSE THE | | SCREEN ROOM TO A DEN AND MASTER SITTING ROOM. | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | PLEASE BE ADVISED IF PREVIOUS NON-PERMITTED WORK IS | | PROPOSED TO REMAIN IN PLACE, THEN PURSUANT TO FBC 117 - | | THE BUILDING OFFICIAL MAY REQUIRE TESTS OR TEST REPORTS | | AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE TO BE MADE | | AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN APPROVED | | TESTING LABORATORY OR OTHER APPROVED AGENCY. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2016-07-28 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-07-28 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-07-28 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-06-20 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-06-20 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-06-20 |
Time |
11:34 |
Sent To |
|
|
Notes |
2016-06-20 12:00:31 | SENT TO GEORGE PLUMBING. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-04-04 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-04-04 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-04-04 |
Time |
15:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-10-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-20 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-20 |
Time |
10:59 |
Sent To |
|
|
Notes |
2015-10-20 11:30:23 | 1ST REVIEW: FBC 2014 5TH ED. | | | | PLEASE SEE NOTES IN BUILDING REVIEW AS TO THE CONFLICT | | BETWEEN THE PROPOSED PLAN WHICH DESIGNATES THE 297 SF | | PORCH AS A DEN. PLEASE PROVIDE AN ELECTRICAL PLAN FOR | | THE AREA DESIGNATED AS A DEN AND REGARDING SMOKE | | DETECTORS AS FOLLOWS: EXISTING OR PROPOSED ELECTRICAL | | OUTLETS AND LIGHTING TO DEMONSTRATE COMPLIANCE WITH THE | | FOLLOWING: | | | | FBCRE4002.14 TAMPER-RESISTANT RECEPTACLES. | | IN AREAS SPECIFIED IN SECTION E3901.1, 125-VOLT, 15- | | AND 20-AMPERE RECEPTACLES SHALL BE LISTED | | TAMPER-RESISTANT RECEPTACLES. | | | | FBCRE3902.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, | | 15- AND 20-AMPERE OUTLETS INSTALLED IN FAMILY ROOMS, | | DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED | | BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER | | INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. | | | | FBCRE3901.2.2 SPACING. | | RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT | | MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL | | SPACE IS MORE THAN 6 FEET (1829 MM), FROM A RECEPTACLE | | OUTLET. | | | | E3903.3 ADDITIONAL LOCATIONS. | | AT LEAST ONE WALL-SWITCH-CONTROLLED LIGHTING OUTLET | | SHALL BE INSTALLED TO PROVIDE ILLUMINATION ON THE | | EXTERIOR SIDE OF EACH OUTDOOR EGRESS DOOR HAVING GRADE | | LEVEL ACCESS. | | | | FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO | | FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-22 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-22 |
Time |
12:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2016-08-19 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-08-19 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-07-13 |
Time |
10:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-06-22 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-06-17 |
Time |
13:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-05-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-05-31 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-05-27 |
Time |
14:18 |
Sent To |
|
|
Notes |
2016-05-27 14:18:30 | RESUB ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-04-05 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-03-18 |
Time |
13:22 |
Sent To |
|
|
Notes |
2016-03-18 13:22:15 | RESUB ROUTED TO SKENNEDY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
P |
Date |
2015-10-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-20 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-01 |
Time |
13:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
6 |
Status |
P |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-22 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-22 |
Time |
12:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
5 |
Status |
F |
Date |
2016-08-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-18 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-18 |
Time |
08:11 |
Sent To |
|
|
Notes |
2016-08-18 08:11:41 | CONTRACTOR TO SIGN OUT PLANS AFTER PLAN REVIEW. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
F |
Date |
2016-06-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-17 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-06-17 |
Time |
13:36 |
Sent To |
|
|
Notes |
2016-06-17 13:37:53 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 4TH REVIEW | | DATE: 6/17/16 | | ACTION: DENIED | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURN STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2016-05-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-05-31 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-05-31 |
Time |
13:40 |
Sent To |
|
|
Notes |
2016-05-31 13:47:24 | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-7918 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 3RD REVIEW | | DATE: 5/31/16 | | ACTION: FAILED | | | | 1. THE PLAN APPEARS TO INCLUDE THE CONDITIONING OF A | | 297 SF AREA OF THE RESIDENCE IDENTIFIED AS A DEN BUT ON | | RECORD AS A PORCH. | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURN STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-04-05 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-04-05 |
Time |
09:24 |
Sent To |
|
|
Notes |
2016-04-05 09:26:18 | | | 2ND REVIEW: FBC 2014 5TH ED | | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURN STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-10-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-20 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-20 |
Time |
10:05 |
Sent To |
|
|
Notes |
2015-10-20 10:05:29 | 1ST REVIEW: FBC 2014 5TH ED. | | | | THE PLAN APPEARS TO PROPOSE CONDITIONING A 297 SF AREA | | OF THE RESIDENCE APPARENTLY ON RECORD AS A PORCH. | | WINDOW REPLACEMENT PERMIT 10060887 PLAN COMPLETED IN | | 2010 DOES NOT SHOW THE CONSTRUCTION OF WALLS AND | | WINDOWS AS CONSISTENT WITH THE PROPOSED PLAN, | | THEREFORE: | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2016-08-18 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-08-18 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-08-18 |
Time |
17:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2016-06-21 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-06-21 |
Time |
18:11 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-06-21 |
Time |
17:56 |
Sent To |
|
|
Notes |
2016-06-21 18:09:27 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | (1) PROVIDE MECHANICAL PLANS. | | (2) SHOW DUCT SIZES, SUPPLY OUTLET SIZES AND CFM | | QUANTITIES. | | (3) DIFFERENTIATE WHAT IS EXISTING AND WHAT IS NEW. | | (4) PROVIDE EXISTING AHU EQUIPMENT SCHEDULE (TO INCLUDE | | TOTAL CFM). | | (5) PROVIDE EXHAUST DUCT SIZES FOR KITCHEN EXHAUST. | | (6) HAVE ALL MANUFACTURER SPECIFICATION DOCUMENTATION | | FOR KITCHEN EXHAUST AT JOBSITE FOR INSPECTOR TO VERIFY | | INSTALLATION. | | | | M1503.4 MAKEUP AIR REQUIRED. | | EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF | | 400 CUBIC FEET PER MINUTE (0.19 M3/S) SHALL BE PROVIDED | | WITH MAKEUP AIR AT A RATE APPROXIMATELY EQUAL TO THE | | EXHAUST AIR RATE. SUCH MAKEUP AIR SYSTEMS SHALL BE | | EQUIPPED WITH A MEANS OF CLOSURE AND SHALL BE | | AUTOMATICALLY CONTROLLED TO START AND OPERATE | | SIMULTANEOUSLY WITH THE EXHAUST SYSTEM. | | | | EXCEPTION: IN A SINGLE-FAMILY DWELLING, MAKE-UP AIR IS | | NOT REQUIRED FOR RANGE HOOD EXHAUST SYSTEMS CAPABLE OF | | EXHAUSTING: | | (A) FOUR HUNDRED CUBIC FEET PER MINUTE OR LESS; OR | | (B) MORE THAN 400 CUBIC FEET PER MINUTE BUT NO MORE | | THAN 800 CUBIC FEET PER MINUTE IF THERE ARE NO GRAVITY | | VENT APPLIANCES WITHIN THE CONDITIONED LIVING SPACE OF | | THE STRUCTURE. | | | | FLORIDA ENERGY CODE FBC 2014 | | | | PROVIDE (2) SETS OF SIGNED ENERGY CALCULATIONS (FORM | | R405-2014 AND HEAT LOAD CALCULATIONS). ONLY ONE | | PROVIDED | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-04-05 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-04-05 |
Time |
16:42 |
Sent To |
|
|
Notes |
2016-04-05 16:45:08 | NO MECHANICAL WORK |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-10-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-20 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-20 |
Time |
10:53 |
Sent To |
|
|
Notes |
2015-10-20 10:57:51 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | PLEASE SEE THE COMMENTS UNDER BUILDING AS TO THE | | REQUIRED ENERGY SUBMITTAL AND QUALITY OF PLAN REQUIRED. | | PROVIDE A MECHANICAL PLAN. | | | | FBC- 107.3.5.3 ? PROVIDE A MECHANICAL PLAN TO SHOW | | SUPPLY DUCTS PER FBC-R M16 | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2016-07-23 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-07-23 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-07-23 |
Time |
12:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2016-06-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-21 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-06-21 |
Time |
10:02 |
Sent To |
|
|
Notes |
2016-06-21 10:39:13 | 3RD REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | 1.NEW BATHROOM AND OUTDOOR KITCHEN ARE NOT VENTED SHOW | | ON RISER DIAGRAM. PER FBC PL SEC. P3101.2.1 | | | | 2. OUT DOOR KITCHEN SHALL TIE INTO BUILDING DRAIN DOWN | | STREAM OF BATHROOM GROUP. PER FBC PL SEC.P3108.1 | | | | 3. PROVIDE DETAILED SCOPE OF PLUMBING WORK IT IS | | UNCLEAR ON PLAN . THERE IS A NOTE FOR DOMESTIC WATER | | SCOPE OF WORK IT APPEARS THAT YOU ARE INSTALLING ALL | | NEW HOT AND COLD WATER SYSTEM PLEASE CLARIFY. ARE THE | | EXISTING FIXTURES BEING REPLACED REMAINING IN SAME | | LOCATION PLEASE CLARIFY. PER WPB AMEND. TO FBC SEC. | | 107.2.1 | | | | 4. VALUATION OF JOB PLEASE CLARIFY AND UPDATE. YOUR | | PROPOSAL STATES A VALUE OF $60,000 DOES THIS INCLUDE | | FIXTURES, DOORS AND WINDOWS SUPPLIED BY OWNER, IT ALSO | | HAS TO INCLUDE NEW BATHROOM AND NEW WATER PIPING SYSTEM | | THESE WERE NOT IN YOUR DECRYPTION OF WORK. THE VALUE ON | | PERMIT APPLICATION DOES NOT MATCH WHAT IS ON YOUR | | PROPOSAL . THE VALUE ON PERMIT APPLICATION SHALL | | INCLUDE COMPLETE JOB EXCLUDING ONLY LAND VALUE. PER WPB | | AMEND. TO FBC SEC. 109.3 | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-06-01 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-06-01 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-06-01 |
Time |
12:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-03-23 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-03-23 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-10-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-10-13 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-10-13 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|