Plan Review Details - Permit 15090732
Plan Review Stops For Permit 15090732
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-02-05 Cont ID  
Sent By jwitmer Date 2016-02-05 Time   Rev Time 0.00
Received By jwitmer Date 2016-02-05 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-12-14 Cont ID  
Sent By jwitmer Date 2015-12-14 Time   Rev Time 0.00
Received By jwitmer Date 2015-12-10 Time 16:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-03-14 Cont ID  
Sent By albarran Date 2016-03-14 Time 14:20 Rev Time 0.00
Received By albarran Date 2016-03-14 Time 12:33 Sent To I
Notes
2016-03-14 14:21:07ALL PREVIOUS;Y MENTIONED DEFICIENCIES HAVE BEEN
 SATISFACTORILY CORRECTED.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2016-02-24 Cont ID  
Sent By albarran Date 2016-02-24 Time 14:15 Rev Time 0.00
Received By albarran Date 2016-02-23 Time 17:14 Sent To  
Notes
2016-02-24 14:22:582ND ELECTRICAL REVIEW NOTES FOR REVISION #:15090732
 REVIEWED FOR COMPLIANCE WITH:
 FBC 2010 EDITION
 NFPA 70 2008 (NEC)
  
 CORRECTIONS REQUIRED:
 IN FOLLOWING YOUR RESPONSE LETTER ON THE ELECTRICAL
 REVIEW COMMENTS OF THE PREVIOUS REVIEW, BELOW IS A LIST
 OF ITEMS THAT REQUIRE FURTHER EXPLANATION OR ACTION.
 THESE WILL BE NUMBERED AS IN THE INITIAL REVIEW BECAUSE
 THEY ARE NOT NEW COMMENTS BUT PREVIOUS COMMENTS NOT
 PROPERLY ADDRESSED.
 1. COMMENT #3 DEALING WITH THE SHOW WINDOW OUTLETS. NEC
 210.62 REQUIRES THAT THERE BE AN OUTLET WITHIN 18" OF
 THE TOP OF THE WINDOW FOR EVERY 12' OF WINDOW OR MAJOR
 PORTION THEREOF. IT DOESN'T MEAN THAT IF YOU HAVE TWO
 6' WINDOWS A SINGLE OUTLET WILL DO. YOU SHALL HAVE AN
 OUTLET WITHIN 18" OF THE TOP OF EACH WINDOW.
 2. COMMENT #6 DEALING WITH THE "WEATHER RESISTANT"
 RECEPTACLES. NEC 406.8(B) REQUIRES THAT ALL RECEPTACLES
 IN WET LOCATIONS BE IN ADDITION TO THE WEATHER-PROOF
 ENCLOSURE, ALSO BE LISTED AS WEATHER-RESISTANT "WR".
 3. COMMENT #7 DEALS WITH THE DEDICATED SIGN OUTLET. NEC
 600.5 REQUIRES THAT THERE BE IN AN ACCESSIBLE LOCATION
 A DEDICATED OUTLET FOR SIGNAGE AT EVERY PEDESTRIAN
 ENTRY DOOR.
 4. COMMENT #8 EMERGENCY AND EXIT LIGHTS. THE EMERGENCY
 LIGHTING AS SHOWN ON THE PLANS DOES NOT MEET MINIMUM
 STANDARDS. IN ADDITION TO EMERGENCY LIGHTING, AN EXIT
 LIGHT IS MISSING TO INDICATE THE REAR EXIT CORRIDOR AS
 THAT SIGN ABOVE THE DOOR IS NOT VISIBLE FROM LOCATIONS
 WITHIN THE PREMISES.
 5. COMMENT #9 CONTINUES TO DEAL WITH THE EMERGENCY AND
 EXIT LIGHTS. NEC 700.12 REQUIRES THAT EMERGENCY LIGHTS
 BE ON THE SAME CIRCUIT AS THE LIGHTING OF THE AREA
 WHICH THEY OCCUPY. WHETHER AHEAD OF THE SWITCH OR NOT
 DOES NOT INDICATE COMPLIANCE WITH CODE. MARK ON THE
 PLANS THE LIGHTING CIRCUIT USED TO POWER THE EMERGENCY
 LIGHTS WHEN THEY ARE INCORPORATED INTO THE PLANS.
 6. COMMENT #10 ASKS FOR DEFINITION OF THE FEEDER
 CONDUCTORS OF THE RISER DIAGRAM. ACCORDING TO YOUR LOAD
 CALCS FOR PANEL B, THE CONNECTED LOAD IS 152 AMP. PER
 NEC 310.15 THE AMPACITY OF THE #2 CONDUCTOR IS ONLY 115
 AMP. THE SAME APPLIES TO THE CONDUCTORS FOR PANEL A.
 CONNECTED LOAD OF 291 AMP FEED WITH A 3/0 CONDUCTOR
 LISTED FOR ONLY 200 AMP. THIS IS ALL ASSUMING THAT YOU
 ARE USING COPPER CONDUCTORS WITH 75 DEGREE INSULATION
 WHICH AGAIN IS NOT DEFINED. PER NEC 220.88, THE
 CONNECTED LOADS OF BOTH PANELS (160 KW) BEING <200 KW
 FOR A NOT ALL ELECTRIC RESTAURANT BE CONSIDERED AT 100
 DEMAND. THEREFORE 160 KW @ 208 V. 3? HAS A CONNECTED
 LOAD VALUE OF 443 AMP. MAIN FEEDER CONDUCTORS SHALL BE
 SIZED ACCORDINGLY.
 7. COMMENT #11 ENERGY CODE REQUIREMENTS. IN ADDITION TO
 THE LIGHTING POWER DENSITY ALLOWANCES THE FBC-ENERGY
 CONSERVATION SECTION HAS MANDATORY SWITCHING & LIGHTING
 CONTROL REQUIREMENTS WHICH SHALL BE ADDRESSED ON THE
 PLANS.
 8. COMMENT #12 FIXTURE SCHEDULE. INCLUDE IN THE FIXTURE
 SCHEDULE THE TYPE AND LABEL DESIGNATOR FOR THE PROPOSED
 EMERGENCY LIGHTING FIXTURE AND/OR NIGHT LIGHT FIXTURE.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-12-30 Cont ID  
Sent By albarran Date 2015-12-30 Time 13:47 Rev Time 0.00
Received By albarran Date 2015-12-30 Time 11:27 Sent To I
Notes
2015-12-30 13:53:44THE PLANS FOR THE ABOVE MENTIONED REVISION HAS BEEN
 REVIEWED FOR COMPLIANCE WITH THE EDITION OF THE NEC,
 (NATIONAL ELECTRICAL CODE), FIRE CODES AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 1. CLEARLY DEFINE YOUR SCOPE OF WORK ON BOTH, THE
 REVISION FORM AND PLANS. THEY MUST MATCH.
 2. NEC 210.8 REQUIRES THAT ALL RECEPTACLES IN KITCHENS,
 BATHROOMS AND ROOFTOPS BE GFCI PROTECTED.
 3. NEC 210.62. AT LEAST ONE RECEPTACLE OUTLET SHALL BE
 INSTALLED WITHIN 18? OF THE TOP OF A SHOW WINDOW FOR
 EVERY 12 LINEAR FT. OR MAJOR PORTION THEREOF AREA
 MEASURED HORIZONTALLY. BASED ON THE MEASURED SHOW
 WINDOW FOOTAGE ON THE PLANS, YOU SHALL ADD AN
 ADDITIONAL SHOW WINDOW OUTLET FOR BOTH THE DOWNSTAIRS
 WINDOW AS WELL AS THE UPSTAIRS.
 4. NEC 314.27(A) LUMINAIRE OUTLETS. BOXES USED AT
 LUMINAIRE OR LAMPHOLDER OUTLETS IN A CEILING SHALL BE
 REQUIRED TO SUPPORT A LUMINAIRE WEIGHING A MINIMUM OF
 50 LB. ADD THIS TO THE NOTES ON CEILING OUTLETS.
 5. NEC 314.27(D) PADDLE FANS. BOXES USED FOR THE SOLE
 SUPPORT OF CEILING FANS SHALL BE MARKED BY THE
 MANUFACTURER AS SUITABLE FOR THE PURPOSE, AND INDICATE
 THE WEIGHT LIMITATIONS BUT SHALL NOT BE USED TO SUPPORT
 PADDLE FANS HEAVIER THAN 70 LBS.
 6. NEC 406.8(B), RECEPTACLES OUTDOORS OR EXPOSED TO THE
 WEATHER SHALL BE LISTED WEATHER-RESISTANT ?WR?.
 7. NEC 600.5 REQUIRED BRANCH CIRCUIT. EACH COMMERCIAL
 BUILDING AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO
 PEDESTRIANS SHALL BE PROVIDED WITH AT LEAST ONE 20 AMP
 DEDICATED OUTLET IN AN ACCESSIBLE LOCATION AT EACH
 ENTRANCE TO EACH TENANT SPACE FOR SIGN OR OUTLINE
 LIGHTING. SERVICE HALLWAYS OR CORRIDORS SHALL NOT BE
 CONSIDERED ACCESSIBLE TO PEDESTRIANS.
 8. REVISE YOUR PLANS TO INCLUDE THE REQUIRED EMERGENCY
 AND EXIT LIGHTING.
 9. NEC 700.12 (F) (4) - EMERGENCY LIGHTING SHALL BE FED
 BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR MORE
 LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY BE ON
 OWN CIRCUIT.
 10. REDEFINE THE FEEDERS BETWEEN THE METER AND THE
 FIRST DISCONNECT. INCLUDE CONDUCTOR INSULATION &
 RACEWAY SIZING.
 11. FBC-E 505 HAS SPECIFIC MANDATORY ELECTRICAL POWER
 AND LIGHTING SYSTEMS REQUIREMENTS WHICH SHALL BE
 ADHERED TO.
 12. THE FIXTURE SCHEDULE AS SUBMITTED REFERS TO A NOTE
 3 NOT IDENTIFIED ON THE PLANS.
 13. PROVIDE A FIXTURE SCHEDULE AS REQUIRED ALONG WITH
 THE REQUIRED LIGHT DENSITY CHART TO SHOW COMPLIANCE.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE
 INSERT CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK
 VOID AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-01-29 Cont ID  
Sent By pleduc Date 2016-01-29 Time   Rev Time 0.00
Received By pleduc Date 2016-01-29 Time 10:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-11-25 Cont ID  
Sent By pleduc Date 2015-11-25 Time   Rev Time 0.00
Received By pleduc Date 2015-11-25 Time 10:51 Sent To  
Notes
2015-11-25 11:24:41THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1. A FIRE SPRINKLER PLAN SCHEMATIC IS NOT PROVIDED,
 SEPARATE SHOP DRAWINGS SHALL BE SUBMITTED
  
 2. A FIRE ALARM SCHEMATIC IS NOT PROVIDED, SEPARATE
 SHOP DRAWINGS SHALL BE SUBMITTED
  
 3. A STAIR AND RAILING DETAIL IS NOT PROVIDED FOR
 EITHER STAIR.
  
 4. ALL EXIT SIGN LOCATIONS ARE NOT PROVIDED.
  
 5. EMERGENCY LIGHT LOCATIONS ARE NOT PROVIDED.
  
 6. A DOOR SCHEDULE, INCLUDING HARDWARE, EXIT HARDWARE,
 FRAME TYPE, FIRE RATING, LOCKING MECHANISM, IS NOT
 PROVIDED.
  
 7. FIRE EXTINGUISHER LOCATIONS ARE NOT PROVIDED.
  
 8. PROVIDE A NOTE: ALL COOKING EQUIPMENT SHALL COMPLY
 WITH NFPA 96, INCLUDING VENTILATION AND SUPPRESSION
 SYSTEMS, UNDER SEPARATE SHOP DRAWINGS, SHALL BE
 SUBMITTED.
  
 9. AT THE 1ST FLOOR EXIT CORRIDOR, THE KITCHEN DOOR AND
 THE TWO DOUBLE DOORS OPEN INTO THE CORRIDOR AND
 ENCROUCH INTO THE EXIT CORRIDOR. NO DIMENSIONS ARE
 PROVIDED.
  
 NFPA 101 CHAPTER 7, MEANS OF EGRESS
  
 7.2.1.4.3 DOOR LEAF ENCROACHMENT
 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE
 REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY,
 OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT
 MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A
 CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN,
 UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET:
 (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN
 EXISTING BUILDING.
 (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS
 PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED
 WIDTH OF THE STAIR LANDING WHEN THE DOOR LEAF IS FULLY
 OPEN.
  
 PROVIDE DIMESNIONS INDICATING COMPLIANCE WITH THE CODE
 OR PROVIDE ALTERNATIVE DOOR OPTIONS.
  
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2016-11-02 Cont ID  
Sent By tklarge Date 2016-03-12 Time 14:25 Rev Time 0.00
Received By tklarge Date 2016-03-03 Time 14:25 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2016-02-29 Cont ID  
Sent By aaponte Date 2016-02-29 Time 14:51 Rev Time 0.00
Received By aaponte Date 2016-02-29 Time 14:51 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2015-12-22 Cont ID  
Sent By fmittner Date 2015-12-22 Time 16:19 Rev Time 0.00
Received By fmittner Date 2015-12-22 Time 16:19 Sent To  
Notes
2015-12-22 16:19:55NO ELEVATION PROVIDED. FRIEDERIKE MITTNER, 822-1457
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-03-14 Cont ID  
Sent By albarran Date 2016-03-14 Time 14:22 Rev Time 0.00
Received By albarran Date 2016-03-03 Time 12:52 Sent To  
Notes
2016-03-14 14:23:533/14/16 PASSED LAST OF ALL REVIEWS, ARCHITECT NOTIFIED
 IN LIEU OF CONTRACTOR, SENT FILE TO LARGE READY BIN
 "W". MA
2016-03-03 12:52:29C09

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-02-29 Cont ID  
Sent By lmarchan Date 2016-02-29 Time 15:10 Rev Time 0.00
Received By lmarchan Date 2016-01-26 Time 08:49 Sent To  
Notes
2016-01-27 08:50:16C08

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-30 Cont ID  
Sent By albarran Date 2015-12-30 Time 13:57 Rev Time 0.00
Received By albarran Date 2015-11-17 Time 10:28 Sent To  
Notes
2015-12-30 13:57:0612/30/15 FAILED THE LAST OF THE TRADE REVIEWS AND IS
 READY FOR RESUBMITTAL. CONTACTED MEGAN VIA PHONE CALL
 AND SENT FILE TO SMALL DENIED BIN "W". MA
2015-11-18 10:29:55C04

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-18 Cont ID  
Sent By tklarge Date 2015-09-18 Time 11:08 Rev Time 0.00
Received By tklarge Date 2015-09-17 Time 11:03 Sent To  
Notes
2015-09-17 11:03:16REVISION ROUTED TO TKLARGE

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-03-14 Cont ID  
Sent By ccole Date 2016-03-10 Time 13:42 Rev Time 0.00
Received By ccole Date 2016-03-10 Time 11:41 Sent To  
Notes
2016-03-10 11:44:11MECHANICAL PROVISO
 3/10/16
  
 1) WIND LOAD ENGINEERING FOR TIE DOWN AND ATTACHMENT OF
 THE CU, RTU'S, CURBS AND STANDS SHALL BE SUBMITTED TO
 THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL PRIOR
 TO 1ST INSPECTION.
 2) VALUE INCREASE ON PERMIT APPLICATION REQUIRED FOR
 COST OF LARGER 1ST FLOOR AC SYSTEM.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-02-05 Cont ID  
Sent By ccole Date 2016-02-05 Time 17:03 Rev Time 0.00
Received By ccole Date 2016-02-05 Time 17:03 Sent To  
Notes
2016-02-05 17:21:422ND REVIEW: FBC 2014 MECHANICAL
 PERMIT #15090732
 2/5/16
  
 1) THE HEAT LOAD SUMMARY ON SHEET M-1 IS INCOMPLETE AND
 SHALL BE SUBMITTED ON A SEPARATE SIGNED AND SEALED
 SUMMARY SHEET- REFER TO SECTION 503.2.1 FBC-10 ENERGY
 CONSERVATION (EXCEPTION):
 WHERE MECHANICAL SYSTEMS ARE DESIGNED BY A REGISTERED
 ENGINEER, THE ENGINEER HAS THE OPTION OF SUBMITTING A
 SIGNED AND SEALED SUMMARY SHEET TO THE BUILDING
 DEPARTMENT IN LIEU OF THE COMPLETE SIZING
 CALCULATION(S). SUCH SUMMARY SHEET SHALL INCLUDE THE
 FOLLOWING (BY ZONE):
 1. PROJECT NAME/OWNER
 2. PROJECT ADDRESS
 3. AREA IN SQUARE FEET
 4. SIZING METHOD USED
 5. OUTDOOR DRY BULB USE
 6. INDOOR DRY BULB
 7. OUTDOOR WET BULB USED
 8. GRAINS WATER (DIFFERENCE)
 9. TOTAL SENSIBLE GAIN
 10. TOTAL LATENT GAIN
 11. RELATIVE HUMIDITY
 12. TOTAL COOLING REQUIRED WITH OUTSIDE AIR
 13. TOTAL HEATING REQUIRED WITH OUTSIDE AIR
 2) UNDER THIS REVISION, PLEASE CLARIFY HOW THE THE HEAT
 LOAD HAS INCREASED FROM 131 MBH TO 230 MBH COOLING ,
 AND 35.8 TO 83 MBH HEATING WHEN THERE APPEARS TO BE NO
 APPARENT CHANGE IN THE ZONE, THE OCCUPANT LOAD, OR THE
 OUTSIDE AIR INTAKE.
 3) DUE TO THE CHANGE IN THE 1ST FLOOR AC SYSTEM, A
 REVISED ENERGY CALCULATION FORM 506-2010 MUST BE
 SUBMITTED.
 4) PROVIDE AN AIR BALANCE CALCULATION ON THE PLAN.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-11-23 Cont ID  
Sent By hmoser Date 2015-11-23 Time 11:06 Rev Time 0.00
Received By ccole Date 2015-11-23 Time 10:43 Sent To  
Notes
2015-11-23 11:11:391ST REVIEW 2010 MECHANICAL
 REVISION #15090732
 MASTER #14030818
 11/23/15
  
 1) REVISE THE HEAT LOAD AND AIR BALANCE CALCULATIONS TO
 INCLUDE THE NEW GAS-FIRED APPLIANCES AND EXHAUST HOOD
 IN THE NEW 1ST FLOOR KITCHEN.
 2) PLACE A NOTE ON THE PLAN INDICATING THE KITCHEN
 HOOD, THE KITCHEN HOOD FIRE SUPPRESSION, AND THE
 WALK-IN BOXES WILL BE DONE UNDER SEPARATE PERMIT.
 3) CLARIFY IF A SHAFT WILL BE CONSTRUCTED TO HOUSE THE
 NEW GREASE DUCT INSTALLATION, AND PROVIDE DETAILS ON
 THE PLAN IF APPLICABLE
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2016-03-12 Cont ID  
Sent By tklarge Date 2016-03-12 Time 04:54 Rev Time 0.00
Received By tklarge Date 2016-03-12 Time 03:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2016-02-03 Cont ID  
Sent By tklarge Date 2016-01-30 Time 11:45 Rev Time 0.00
Received By tklarge Date 2016-01-30 Time 10:13 Sent To  
Notes
2016-01-30 12:04:511) SHT. P-5 - THE NOTE ON THE PLAN REFERS TO GAS TABLE
 402.4 (2). THIS TABLE IS FOR A SYSTEM WITH LESS THAN 2
 PSI BUT THE PLANS ALSO NOTE THAT THE INLET PRESSURE IS
 2 PSI. WHICH IS IT? I CANNOT DO A THOROUGH REVIEW ON
 THE GAS UNLESS THE CORRECT PRESSURE AND PROPER SIZING
 TABLE ARE ON THE PLANS.
 2) SHT. P-5 - THE PLANS REFER TO THE 2007 FUEL GAS
 CODE. THE CODE IN EFFECT FOR THIS PROJECT IS THE 2010
 FBC & FUEL GAS CODE.
 3) THE GAS PLAN NOTES THE BTU LOAD IS 667K BUT MY
 CALCULATIONS ARE 906K. PLEASE CHECK YOUR CALCULATIONS.
 4) SUBMIT AN EXPANDED SANITARY RISER FOR THE SECOND
 FLOOR. IT IS EXTREMELY DIFFICULT TO SEE WHERE ONE LINE
 STOPS AND ANOTHER BEGINS.DON'T OVERLAY THE FIRST FLOOR
 RISER FOR THE GREASY WASTE WITH THE 2ND FLOOR RISER.
 SHT. P-5 - THE FIXTURES IN THE FOOD PREP AREA ARE NOT
 ON THE WATER RISER. CLARIFY.
 5) SHT. P-5- THE 2ND FLOOR WATER RISER REFERS TO THE
 3RD FLOOR. CLARIFY. WHERE IS THE WATER RISER CONNECTION
 TO THE FIRST FLOOR?
 6) SHT. P-6 - FIRST FLOOR GREASY WASTE - THE VENT IS
 MISSING FOR THE TWO FLOOR SINKS IN THE FOOD PREP ARREA.
 7) THE AIR ADMITTTANCE VALVE (STUDOR VENT) IS MISSING
 ON THE FIRST FLOOR GREASY WASTE RISER IN THE BAR AREA.
 8) IDENTIFY THE AIR ADMITTANCE VALVES ON THE 2ND FLOOR
 GREASY WASTE.
 9) SHT.P-6 - THE SECOND FLOOR GREASY WASTE STILL SHOWS
 THE ICE BINS DISCHARGING INTO THE GREASY WASTE. WASTES
 THAT DO NOT REQUIRE SEPARATION OR TREATMENT SHALL NOT
 BE DISCHARGED INTO ANY INTERCEPTOR OR SEPARATOR PER THE
 2010 FBC- PLUMBING SEC.1003.2. 3RD REQUEST.
 10) THE SPECIFICATIONS FOR THE GAS APPLIANCES HAVE NOT
 BEEN SUBMITTED. SUBMIT MANUF. SPECS FOR THE GAS
 EQUIPMENT.3RD REQUEST.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-11-21 Cont ID  
Sent By tklarge Date 2015-11-21 Time 07:50 Rev Time 0.00
Received By tklarge Date 2015-11-21 Time 06:57 Sent To  
Notes
2015-11-21 07:49:571) SUBMIT INTERCEPTOR SIZING CALCULATIONS. THE
 INTERCEPTOR SHALL BE SIZED IN ACCORDANCE WITH ONE OF
 THE METHODS LISTED IN THE 2010 FBC SEC.1003.3.4. 2ND
 REQUEST.
 2) SUBMIT MANUF. SPECS FOR THE ADDED GAS EQUIPMENT AND
 SUBMIT A COMPLETE GAS DRAWING FOR REVIEW.WPB AMEND. TO
 FBC SEC. 107.2.1. 2ND REQUEST
 3) SHT.P-4 - SHOWS THE DRAINS FROM ICE BINS DISCHARGING
 INTO THE GREASE INTERCEPTOR.WASTES THAT DO NOT REQUIRE
 TREATMENT OR SEPARATION SHALL NOT BE DISCHARGED INTO
 ANY INTERCEPTOR OR SEPARATOR PER 2010 FBC-PLUMBING
 SEC.1003.2. 2ND REQUEST.
 4) GREASE INTTERCEPTORS SHALL BE EQUIPPED WITH DEVICES
 TO CONTROL THE RATE OF WATER FLOW SO THAT THE WATER
 FLOW DOES NOT EXCEED THE RATED FLOW PER FBC-PLUMBING
 SEC.1003.3.4.2. 2ND REQUEST. REFER TO THE
 MANUFACTURER'S INSTALLATION INSTRUCTIONS THAT I PRINTED
 OUT SINCE THEY WERE NOT SUBMITTED AS PREVIOUSLY
 REQUESTED.SHOW THE REQUIRED VENT ON THE RISER
 DIAGRAM.THE VENT FOR THE SERVICE SINK WILL NOT SUFFICE
 FOR THE INTERCEPTOR.
 5) SUBMIT A WATER RISER FOR REVIEW FOR THE CHANGES MADE
 TO THE WATER PIPING SYSTEM. WPB AMEND. TO FBC SEC.
 107.3.5.1.3.2ND REQUEST.
 6) SUBMIT AN EXPANDED SANITARY RISER DIAGRAM. IT IS
 DIFFICULT TO SEE WHERE ONE LINE STOPS AND ANOTHER
 BEGINS. WPB AMEND. TO FBC SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-09-18 Cont ID  
Sent By tklarge Date 2015-09-18 Time 11:07 Rev Time 0.00
Received By tklarge Date 2015-09-18 Time 04:30 Sent To  
Notes
2015-09-18 08:48:071) SUBMIT MANUFACTURER'S SPECIFICATIONS/INSTALL MANUAL
 FOR THE ZURN GREASE INTERCEPTOR FOR REVIEW. WPB AMEND.
 TO FBC SEC.107.2.1, 107.3.5.1.3.
 2) SUBMIT INTERCEPTOR SIZING CALCULATIONS. THE
 INTERCEPTOR SHALL BE SIZED IN ACCORDANCE WITH ONE OF
 THE METHODS LISTED IN THE 2010 FBC SEC.1003.3.4.
 3) SUBMIT A REVISED KITCHEN EQUIPMENT SCHEDULE. THE
 PLANS SHOW A NEW GRIDDLE AND FRYER BUT NO INFORMATION
 HAS BEEN SUBMITTED FOR THESE APPLIANCES.
 4) INDICATE ON THE PLANS IF THE GRIDDLE AND FRYER ARE
 GAS OR ELECTRIC. IF THE APPLIANCES ARE GAS, THEN SUBMIT
 MANUF. SPECS FOR THE EQUIPMENT AND SUBMIT A COMPLETE
 GAS DRAWING FOR REVIEW. IF THE APPLIANCES ARE ELECTRIC,
 SUBMIT COMPLETE ELECTRIC PLANS FOR REVIEW.WPB AMEND. TO
 FBC SEC. 107.2.1.
 5) THE PLANS FOR THIS PLUMBING REVISION SHOW CHANGES
 FRROM THE ORIGINAL PLANS THAT APPEAR TO AFFECT
 STRUCTURAL, MECHANICAL AND ELECTRICAL DISCIPLINES.
 SUBMIT A COMPLETE SET OF PLANS THAT REFLECTS THE ENTIRE
 SCOPE OF CHANGES THAT HAVE BEEN MADE FROM THE ORIGINAL
 PLANS. WPB AMEND. TO FBC SEC. 107.2.1.
 6) SHT.P-4 - SHOWS THE DRAINS FROM ICE BINS DISCHARGING
 INTO THE GREASE INTERCEPTOR.WASTES THAT DO NOT REQUIRE
 TREATMENT OR SEPARATION SHALL NOT BE DISCHARGED INTO
 ANY INTERCEPTOR OR SEPARATOR PER 2010 FBC-PLUMBING
 SEC.1003.2.
 7)THE GREASE INTERCEPTOR SHALL HAVE THE GREASE
 RETENTION CAPACITY INDICATED IN TABLE 1003.3.4.1 OF
 FBC-PLUMBING FOR THE FLOW THROUGH RATES INDICATED.
 8) GREASE INTTERCEPTORS SHALL BE EQUIPPED WITH DEVICES
 TO CONTROL THE RATE OF WATER FLOW SO THAT THE WATER
 FLOW DOES NOT EXCEED THE RATED FLOW PER FBC-PLUMBING
 SEC.1003.3.4.2.
 9) INDICATE THE TYPE OF COOKING OPERATIONS THAT WILL BE
 DONE IN THE STRUCTURE.WPB AMEND. TO FBC SEC. 107.2.1.
 10) SUBMIT A WATER RISER FOR REVIEW. WPB AMEND. TO FBC
 SEC. 107.3.5.1.3.
  
 WHEN A COMPLETE SET OF PLANS ARE SUBMITTED THAT SHOW
 ALL THE CHANGES TO THE BUILDING, ELECTRICAL, MECHANICAL
 AND PLUMBING SYSTEMS THOSE PLANS WILL BE REVIEWED BY
 EACH DISCIPLINE. THE PLANS MUST BE SUBMITTED AS A
 COMPLETE PACKAGE.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2016-02-29 Cont ID  
Sent By aaponte Date 2016-02-29 Time 14:38 Rev Time 0.00
Received By aaponte Date 2016-02-29 Time 14:38 Sent To  
Notes
2016-02-29 14:50:42PROVISO: ANY NEW MECHANICAL EQUIPMENT ON THE ROOF SHALL
 BE SCREENED WITH A WALL, LOUVER OR SIMILAR IN THE SAME
 HEIGHT OF THE EQUIPMENT.
 ESTABLISHMENT SHALL FOLLOW THE ALCOHOL REGULATION IN
 CHAPTER VI OF THE CITY CODE.

Review Stop Z ZONING
Rev No 1 Status P Date 2015-12-22 Cont ID  
Sent By fmittner Date 2015-12-22 Time 16:20 Rev Time 0.00
Received By fmittner Date 2015-12-22 Time 16:20 Sent To E
Notes
2015-12-22 16:20:38ALCOHOL RESTRICTIONS APPLY.