Plan Review Stops For Permit 15090732 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-02-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-02-05 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-02-05 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-12-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-12-14 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-12-10 |
Time |
16:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-03-14 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-03-14 |
Time |
12:33 |
Sent To |
I |
|
Notes |
2016-03-14 14:21:07 | ALL PREVIOUS;Y MENTIONED DEFICIENCIES HAVE BEEN | | SATISFACTORILY CORRECTED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-02-24 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-02-24 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-02-23 |
Time |
17:14 |
Sent To |
|
|
Notes |
2016-02-24 14:22:58 | 2ND ELECTRICAL REVIEW NOTES FOR REVISION #:15090732 | | REVIEWED FOR COMPLIANCE WITH: | | FBC 2010 EDITION | | NFPA 70 2008 (NEC) | | | | CORRECTIONS REQUIRED: | | IN FOLLOWING YOUR RESPONSE LETTER ON THE ELECTRICAL | | REVIEW COMMENTS OF THE PREVIOUS REVIEW, BELOW IS A LIST | | OF ITEMS THAT REQUIRE FURTHER EXPLANATION OR ACTION. | | THESE WILL BE NUMBERED AS IN THE INITIAL REVIEW BECAUSE | | THEY ARE NOT NEW COMMENTS BUT PREVIOUS COMMENTS NOT | | PROPERLY ADDRESSED. | | 1. COMMENT #3 DEALING WITH THE SHOW WINDOW OUTLETS. NEC | | 210.62 REQUIRES THAT THERE BE AN OUTLET WITHIN 18" OF | | THE TOP OF THE WINDOW FOR EVERY 12' OF WINDOW OR MAJOR | | PORTION THEREOF. IT DOESN'T MEAN THAT IF YOU HAVE TWO | | 6' WINDOWS A SINGLE OUTLET WILL DO. YOU SHALL HAVE AN | | OUTLET WITHIN 18" OF THE TOP OF EACH WINDOW. | | 2. COMMENT #6 DEALING WITH THE "WEATHER RESISTANT" | | RECEPTACLES. NEC 406.8(B) REQUIRES THAT ALL RECEPTACLES | | IN WET LOCATIONS BE IN ADDITION TO THE WEATHER-PROOF | | ENCLOSURE, ALSO BE LISTED AS WEATHER-RESISTANT "WR". | | 3. COMMENT #7 DEALS WITH THE DEDICATED SIGN OUTLET. NEC | | 600.5 REQUIRES THAT THERE BE IN AN ACCESSIBLE LOCATION | | A DEDICATED OUTLET FOR SIGNAGE AT EVERY PEDESTRIAN | | ENTRY DOOR. | | 4. COMMENT #8 EMERGENCY AND EXIT LIGHTS. THE EMERGENCY | | LIGHTING AS SHOWN ON THE PLANS DOES NOT MEET MINIMUM | | STANDARDS. IN ADDITION TO EMERGENCY LIGHTING, AN EXIT | | LIGHT IS MISSING TO INDICATE THE REAR EXIT CORRIDOR AS | | THAT SIGN ABOVE THE DOOR IS NOT VISIBLE FROM LOCATIONS | | WITHIN THE PREMISES. | | 5. COMMENT #9 CONTINUES TO DEAL WITH THE EMERGENCY AND | | EXIT LIGHTS. NEC 700.12 REQUIRES THAT EMERGENCY LIGHTS | | BE ON THE SAME CIRCUIT AS THE LIGHTING OF THE AREA | | WHICH THEY OCCUPY. WHETHER AHEAD OF THE SWITCH OR NOT | | DOES NOT INDICATE COMPLIANCE WITH CODE. MARK ON THE | | PLANS THE LIGHTING CIRCUIT USED TO POWER THE EMERGENCY | | LIGHTS WHEN THEY ARE INCORPORATED INTO THE PLANS. | | 6. COMMENT #10 ASKS FOR DEFINITION OF THE FEEDER | | CONDUCTORS OF THE RISER DIAGRAM. ACCORDING TO YOUR LOAD | | CALCS FOR PANEL B, THE CONNECTED LOAD IS 152 AMP. PER | | NEC 310.15 THE AMPACITY OF THE #2 CONDUCTOR IS ONLY 115 | | AMP. THE SAME APPLIES TO THE CONDUCTORS FOR PANEL A. | | CONNECTED LOAD OF 291 AMP FEED WITH A 3/0 CONDUCTOR | | LISTED FOR ONLY 200 AMP. THIS IS ALL ASSUMING THAT YOU | | ARE USING COPPER CONDUCTORS WITH 75 DEGREE INSULATION | | WHICH AGAIN IS NOT DEFINED. PER NEC 220.88, THE | | CONNECTED LOADS OF BOTH PANELS (160 KW) BEING <200 KW | | FOR A NOT ALL ELECTRIC RESTAURANT BE CONSIDERED AT 100 | | DEMAND. THEREFORE 160 KW @ 208 V. 3? HAS A CONNECTED | | LOAD VALUE OF 443 AMP. MAIN FEEDER CONDUCTORS SHALL BE | | SIZED ACCORDINGLY. | | 7. COMMENT #11 ENERGY CODE REQUIREMENTS. IN ADDITION TO | | THE LIGHTING POWER DENSITY ALLOWANCES THE FBC-ENERGY | | CONSERVATION SECTION HAS MANDATORY SWITCHING & LIGHTING | | CONTROL REQUIREMENTS WHICH SHALL BE ADDRESSED ON THE | | PLANS. | | 8. COMMENT #12 FIXTURE SCHEDULE. INCLUDE IN THE FIXTURE | | SCHEDULE THE TYPE AND LABEL DESIGNATOR FOR THE PROPOSED | | EMERGENCY LIGHTING FIXTURE AND/OR NIGHT LIGHT FIXTURE. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-12-30 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-30 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-12-30 |
Time |
11:27 |
Sent To |
I |
|
Notes |
2015-12-30 13:53:44 | THE PLANS FOR THE ABOVE MENTIONED REVISION HAS BEEN | | REVIEWED FOR COMPLIANCE WITH THE EDITION OF THE NEC, | | (NATIONAL ELECTRICAL CODE), FIRE CODES AND THE FBC, | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | 1. CLEARLY DEFINE YOUR SCOPE OF WORK ON BOTH, THE | | REVISION FORM AND PLANS. THEY MUST MATCH. | | 2. NEC 210.8 REQUIRES THAT ALL RECEPTACLES IN KITCHENS, | | BATHROOMS AND ROOFTOPS BE GFCI PROTECTED. | | 3. NEC 210.62. AT LEAST ONE RECEPTACLE OUTLET SHALL BE | | INSTALLED WITHIN 18? OF THE TOP OF A SHOW WINDOW FOR | | EVERY 12 LINEAR FT. OR MAJOR PORTION THEREOF AREA | | MEASURED HORIZONTALLY. BASED ON THE MEASURED SHOW | | WINDOW FOOTAGE ON THE PLANS, YOU SHALL ADD AN | | ADDITIONAL SHOW WINDOW OUTLET FOR BOTH THE DOWNSTAIRS | | WINDOW AS WELL AS THE UPSTAIRS. | | 4. NEC 314.27(A) LUMINAIRE OUTLETS. BOXES USED AT | | LUMINAIRE OR LAMPHOLDER OUTLETS IN A CEILING SHALL BE | | REQUIRED TO SUPPORT A LUMINAIRE WEIGHING A MINIMUM OF | | 50 LB. ADD THIS TO THE NOTES ON CEILING OUTLETS. | | 5. NEC 314.27(D) PADDLE FANS. BOXES USED FOR THE SOLE | | SUPPORT OF CEILING FANS SHALL BE MARKED BY THE | | MANUFACTURER AS SUITABLE FOR THE PURPOSE, AND INDICATE | | THE WEIGHT LIMITATIONS BUT SHALL NOT BE USED TO SUPPORT | | PADDLE FANS HEAVIER THAN 70 LBS. | | 6. NEC 406.8(B), RECEPTACLES OUTDOORS OR EXPOSED TO THE | | WEATHER SHALL BE LISTED WEATHER-RESISTANT ?WR?. | | 7. NEC 600.5 REQUIRED BRANCH CIRCUIT. EACH COMMERCIAL | | BUILDING AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO | | PEDESTRIANS SHALL BE PROVIDED WITH AT LEAST ONE 20 AMP | | DEDICATED OUTLET IN AN ACCESSIBLE LOCATION AT EACH | | ENTRANCE TO EACH TENANT SPACE FOR SIGN OR OUTLINE | | LIGHTING. SERVICE HALLWAYS OR CORRIDORS SHALL NOT BE | | CONSIDERED ACCESSIBLE TO PEDESTRIANS. | | 8. REVISE YOUR PLANS TO INCLUDE THE REQUIRED EMERGENCY | | AND EXIT LIGHTING. | | 9. NEC 700.12 (F) (4) - EMERGENCY LIGHTING SHALL BE FED | | BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR MORE | | LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY BE ON | | OWN CIRCUIT. | | 10. REDEFINE THE FEEDERS BETWEEN THE METER AND THE | | FIRST DISCONNECT. INCLUDE CONDUCTOR INSULATION & | | RACEWAY SIZING. | | 11. FBC-E 505 HAS SPECIFIC MANDATORY ELECTRICAL POWER | | AND LIGHTING SYSTEMS REQUIREMENTS WHICH SHALL BE | | ADHERED TO. | | 12. THE FIXTURE SCHEDULE AS SUBMITTED REFERS TO A NOTE | | 3 NOT IDENTIFIED ON THE PLANS. | | 13. PROVIDE A FIXTURE SCHEDULE AS REQUIRED ALONG WITH | | THE REQUIRED LIGHT DENSITY CHART TO SHOW COMPLIANCE. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | INSERT CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK | | VOID AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-01-29 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-01-29 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-01-29 |
Time |
10:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2015-11-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-11-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-11-25 |
Time |
10:51 |
Sent To |
|
|
Notes |
2015-11-25 11:24:41 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1. A FIRE SPRINKLER PLAN SCHEMATIC IS NOT PROVIDED, | | SEPARATE SHOP DRAWINGS SHALL BE SUBMITTED | | | | 2. A FIRE ALARM SCHEMATIC IS NOT PROVIDED, SEPARATE | | SHOP DRAWINGS SHALL BE SUBMITTED | | | | 3. A STAIR AND RAILING DETAIL IS NOT PROVIDED FOR | | EITHER STAIR. | | | | 4. ALL EXIT SIGN LOCATIONS ARE NOT PROVIDED. | | | | 5. EMERGENCY LIGHT LOCATIONS ARE NOT PROVIDED. | | | | 6. A DOOR SCHEDULE, INCLUDING HARDWARE, EXIT HARDWARE, | | FRAME TYPE, FIRE RATING, LOCKING MECHANISM, IS NOT | | PROVIDED. | | | | 7. FIRE EXTINGUISHER LOCATIONS ARE NOT PROVIDED. | | | | 8. PROVIDE A NOTE: ALL COOKING EQUIPMENT SHALL COMPLY | | WITH NFPA 96, INCLUDING VENTILATION AND SUPPRESSION | | SYSTEMS, UNDER SEPARATE SHOP DRAWINGS, SHALL BE | | SUBMITTED. | | | | 9. AT THE 1ST FLOOR EXIT CORRIDOR, THE KITCHEN DOOR AND | | THE TWO DOUBLE DOORS OPEN INTO THE CORRIDOR AND | | ENCROUCH INTO THE EXIT CORRIDOR. NO DIMENSIONS ARE | | PROVIDED. | | | | NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT | | MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A | | CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN, | | UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET: | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | EXISTING BUILDING. | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED | | WIDTH OF THE STAIR LANDING WHEN THE DOOR LEAF IS FULLY | | OPEN. | | | | PROVIDE DIMESNIONS INDICATING COMPLIANCE WITH THE CODE | | OR PROVIDE ALTERNATIVE DOOR OPTIONS. | | | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2016-11-02 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-03-12 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-03 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2016-02-29 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-02-29 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-02-29 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2015-12-22 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-12-22 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-12-22 |
Time |
16:19 |
Sent To |
|
|
Notes |
2015-12-22 16:19:55 | NO ELEVATION PROVIDED. FRIEDERIKE MITTNER, 822-1457 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-03-14 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-03-03 |
Time |
12:52 |
Sent To |
|
|
Notes |
2016-03-14 14:23:53 | 3/14/16 PASSED LAST OF ALL REVIEWS, ARCHITECT NOTIFIED | | IN LIEU OF CONTRACTOR, SENT FILE TO LARGE READY BIN | | "W". MA | 2016-03-03 12:52:29 | C09 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-02-29 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-02-29 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-01-26 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-12-30 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-30 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-11-17 |
Time |
10:28 |
Sent To |
|
|
Notes |
2015-12-30 13:57:06 | 12/30/15 FAILED THE LAST OF THE TRADE REVIEWS AND IS | | READY FOR RESUBMITTAL. CONTACTED MEGAN VIA PHONE CALL | | AND SENT FILE TO SMALL DENIED BIN "W". MA | 2015-11-18 10:29:55 | C04 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-09-18 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-18 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-17 |
Time |
11:03 |
Sent To |
|
|
Notes |
2015-09-17 11:03:16 | REVISION ROUTED TO TKLARGE |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-03-10 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-03-10 |
Time |
11:41 |
Sent To |
|
|
Notes |
2016-03-10 11:44:11 | MECHANICAL PROVISO | | 3/10/16 | | | | 1) WIND LOAD ENGINEERING FOR TIE DOWN AND ATTACHMENT OF | | THE CU, RTU'S, CURBS AND STANDS SHALL BE SUBMITTED TO | | THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL PRIOR | | TO 1ST INSPECTION. | | 2) VALUE INCREASE ON PERMIT APPLICATION REQUIRED FOR | | COST OF LARGER 1ST FLOOR AC SYSTEM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-02-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-02-05 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-02-05 |
Time |
17:03 |
Sent To |
|
|
Notes |
2016-02-05 17:21:42 | 2ND REVIEW: FBC 2014 MECHANICAL | | PERMIT #15090732 | | 2/5/16 | | | | 1) THE HEAT LOAD SUMMARY ON SHEET M-1 IS INCOMPLETE AND | | SHALL BE SUBMITTED ON A SEPARATE SIGNED AND SEALED | | SUMMARY SHEET- REFER TO SECTION 503.2.1 FBC-10 ENERGY | | CONSERVATION (EXCEPTION): | | WHERE MECHANICAL SYSTEMS ARE DESIGNED BY A REGISTERED | | ENGINEER, THE ENGINEER HAS THE OPTION OF SUBMITTING A | | SIGNED AND SEALED SUMMARY SHEET TO THE BUILDING | | DEPARTMENT IN LIEU OF THE COMPLETE SIZING | | CALCULATION(S). SUCH SUMMARY SHEET SHALL INCLUDE THE | | FOLLOWING (BY ZONE): | | 1. PROJECT NAME/OWNER | | 2. PROJECT ADDRESS | | 3. AREA IN SQUARE FEET | | 4. SIZING METHOD USED | | 5. OUTDOOR DRY BULB USE | | 6. INDOOR DRY BULB | | 7. OUTDOOR WET BULB USED | | 8. GRAINS WATER (DIFFERENCE) | | 9. TOTAL SENSIBLE GAIN | | 10. TOTAL LATENT GAIN | | 11. RELATIVE HUMIDITY | | 12. TOTAL COOLING REQUIRED WITH OUTSIDE AIR | | 13. TOTAL HEATING REQUIRED WITH OUTSIDE AIR | | 2) UNDER THIS REVISION, PLEASE CLARIFY HOW THE THE HEAT | | LOAD HAS INCREASED FROM 131 MBH TO 230 MBH COOLING , | | AND 35.8 TO 83 MBH HEATING WHEN THERE APPEARS TO BE NO | | APPARENT CHANGE IN THE ZONE, THE OCCUPANT LOAD, OR THE | | OUTSIDE AIR INTAKE. | | 3) DUE TO THE CHANGE IN THE 1ST FLOOR AC SYSTEM, A | | REVISED ENERGY CALCULATION FORM 506-2010 MUST BE | | SUBMITTED. | | 4) PROVIDE AN AIR BALANCE CALCULATION ON THE PLAN. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-11-23 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-11-23 |
Time |
10:43 |
Sent To |
|
|
Notes |
2015-11-23 11:11:39 | 1ST REVIEW 2010 MECHANICAL | | REVISION #15090732 | | MASTER #14030818 | | 11/23/15 | | | | 1) REVISE THE HEAT LOAD AND AIR BALANCE CALCULATIONS TO | | INCLUDE THE NEW GAS-FIRED APPLIANCES AND EXHAUST HOOD | | IN THE NEW 1ST FLOOR KITCHEN. | | 2) PLACE A NOTE ON THE PLAN INDICATING THE KITCHEN | | HOOD, THE KITCHEN HOOD FIRE SUPPRESSION, AND THE | | WALK-IN BOXES WILL BE DONE UNDER SEPARATE PERMIT. | | 3) CLARIFY IF A SHAFT WILL BE CONSTRUCTED TO HOUSE THE | | NEW GREASE DUCT INSTALLATION, AND PROVIDE DETAILS ON | | THE PLAN IF APPLICABLE | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2016-03-12 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-03-12 |
Time |
04:54 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-12 |
Time |
03:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2016-02-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-01-30 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-01-30 |
Time |
10:13 |
Sent To |
|
|
Notes |
2016-01-30 12:04:51 | 1) SHT. P-5 - THE NOTE ON THE PLAN REFERS TO GAS TABLE | | 402.4 (2). THIS TABLE IS FOR A SYSTEM WITH LESS THAN 2 | | PSI BUT THE PLANS ALSO NOTE THAT THE INLET PRESSURE IS | | 2 PSI. WHICH IS IT? I CANNOT DO A THOROUGH REVIEW ON | | THE GAS UNLESS THE CORRECT PRESSURE AND PROPER SIZING | | TABLE ARE ON THE PLANS. | | 2) SHT. P-5 - THE PLANS REFER TO THE 2007 FUEL GAS | | CODE. THE CODE IN EFFECT FOR THIS PROJECT IS THE 2010 | | FBC & FUEL GAS CODE. | | 3) THE GAS PLAN NOTES THE BTU LOAD IS 667K BUT MY | | CALCULATIONS ARE 906K. PLEASE CHECK YOUR CALCULATIONS. | | 4) SUBMIT AN EXPANDED SANITARY RISER FOR THE SECOND | | FLOOR. IT IS EXTREMELY DIFFICULT TO SEE WHERE ONE LINE | | STOPS AND ANOTHER BEGINS.DON'T OVERLAY THE FIRST FLOOR | | RISER FOR THE GREASY WASTE WITH THE 2ND FLOOR RISER. | | SHT. P-5 - THE FIXTURES IN THE FOOD PREP AREA ARE NOT | | ON THE WATER RISER. CLARIFY. | | 5) SHT. P-5- THE 2ND FLOOR WATER RISER REFERS TO THE | | 3RD FLOOR. CLARIFY. WHERE IS THE WATER RISER CONNECTION | | TO THE FIRST FLOOR? | | 6) SHT. P-6 - FIRST FLOOR GREASY WASTE - THE VENT IS | | MISSING FOR THE TWO FLOOR SINKS IN THE FOOD PREP ARREA. | | 7) THE AIR ADMITTTANCE VALVE (STUDOR VENT) IS MISSING | | ON THE FIRST FLOOR GREASY WASTE RISER IN THE BAR AREA. | | 8) IDENTIFY THE AIR ADMITTANCE VALVES ON THE 2ND FLOOR | | GREASY WASTE. | | 9) SHT.P-6 - THE SECOND FLOOR GREASY WASTE STILL SHOWS | | THE ICE BINS DISCHARGING INTO THE GREASY WASTE. WASTES | | THAT DO NOT REQUIRE SEPARATION OR TREATMENT SHALL NOT | | BE DISCHARGED INTO ANY INTERCEPTOR OR SEPARATOR PER THE | | 2010 FBC- PLUMBING SEC.1003.2. 3RD REQUEST. | | 10) THE SPECIFICATIONS FOR THE GAS APPLIANCES HAVE NOT | | BEEN SUBMITTED. SUBMIT MANUF. SPECS FOR THE GAS | | EQUIPMENT.3RD REQUEST. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-11-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-11-21 |
Time |
07:50 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-11-21 |
Time |
06:57 |
Sent To |
|
|
Notes |
2015-11-21 07:49:57 | 1) SUBMIT INTERCEPTOR SIZING CALCULATIONS. THE | | INTERCEPTOR SHALL BE SIZED IN ACCORDANCE WITH ONE OF | | THE METHODS LISTED IN THE 2010 FBC SEC.1003.3.4. 2ND | | REQUEST. | | 2) SUBMIT MANUF. SPECS FOR THE ADDED GAS EQUIPMENT AND | | SUBMIT A COMPLETE GAS DRAWING FOR REVIEW.WPB AMEND. TO | | FBC SEC. 107.2.1. 2ND REQUEST | | 3) SHT.P-4 - SHOWS THE DRAINS FROM ICE BINS DISCHARGING | | INTO THE GREASE INTERCEPTOR.WASTES THAT DO NOT REQUIRE | | TREATMENT OR SEPARATION SHALL NOT BE DISCHARGED INTO | | ANY INTERCEPTOR OR SEPARATOR PER 2010 FBC-PLUMBING | | SEC.1003.2. 2ND REQUEST. | | 4) GREASE INTTERCEPTORS SHALL BE EQUIPPED WITH DEVICES | | TO CONTROL THE RATE OF WATER FLOW SO THAT THE WATER | | FLOW DOES NOT EXCEED THE RATED FLOW PER FBC-PLUMBING | | SEC.1003.3.4.2. 2ND REQUEST. REFER TO THE | | MANUFACTURER'S INSTALLATION INSTRUCTIONS THAT I PRINTED | | OUT SINCE THEY WERE NOT SUBMITTED AS PREVIOUSLY | | REQUESTED.SHOW THE REQUIRED VENT ON THE RISER | | DIAGRAM.THE VENT FOR THE SERVICE SINK WILL NOT SUFFICE | | FOR THE INTERCEPTOR. | | 5) SUBMIT A WATER RISER FOR REVIEW FOR THE CHANGES MADE | | TO THE WATER PIPING SYSTEM. WPB AMEND. TO FBC SEC. | | 107.3.5.1.3.2ND REQUEST. | | 6) SUBMIT AN EXPANDED SANITARY RISER DIAGRAM. IT IS | | DIFFICULT TO SEE WHERE ONE LINE STOPS AND ANOTHER | | BEGINS. WPB AMEND. TO FBC SEC. 107.2.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-09-18 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-18 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-18 |
Time |
04:30 |
Sent To |
|
|
Notes |
2015-09-18 08:48:07 | 1) SUBMIT MANUFACTURER'S SPECIFICATIONS/INSTALL MANUAL | | FOR THE ZURN GREASE INTERCEPTOR FOR REVIEW. WPB AMEND. | | TO FBC SEC.107.2.1, 107.3.5.1.3. | | 2) SUBMIT INTERCEPTOR SIZING CALCULATIONS. THE | | INTERCEPTOR SHALL BE SIZED IN ACCORDANCE WITH ONE OF | | THE METHODS LISTED IN THE 2010 FBC SEC.1003.3.4. | | 3) SUBMIT A REVISED KITCHEN EQUIPMENT SCHEDULE. THE | | PLANS SHOW A NEW GRIDDLE AND FRYER BUT NO INFORMATION | | HAS BEEN SUBMITTED FOR THESE APPLIANCES. | | 4) INDICATE ON THE PLANS IF THE GRIDDLE AND FRYER ARE | | GAS OR ELECTRIC. IF THE APPLIANCES ARE GAS, THEN SUBMIT | | MANUF. SPECS FOR THE EQUIPMENT AND SUBMIT A COMPLETE | | GAS DRAWING FOR REVIEW. IF THE APPLIANCES ARE ELECTRIC, | | SUBMIT COMPLETE ELECTRIC PLANS FOR REVIEW.WPB AMEND. TO | | FBC SEC. 107.2.1. | | 5) THE PLANS FOR THIS PLUMBING REVISION SHOW CHANGES | | FRROM THE ORIGINAL PLANS THAT APPEAR TO AFFECT | | STRUCTURAL, MECHANICAL AND ELECTRICAL DISCIPLINES. | | SUBMIT A COMPLETE SET OF PLANS THAT REFLECTS THE ENTIRE | | SCOPE OF CHANGES THAT HAVE BEEN MADE FROM THE ORIGINAL | | PLANS. WPB AMEND. TO FBC SEC. 107.2.1. | | 6) SHT.P-4 - SHOWS THE DRAINS FROM ICE BINS DISCHARGING | | INTO THE GREASE INTERCEPTOR.WASTES THAT DO NOT REQUIRE | | TREATMENT OR SEPARATION SHALL NOT BE DISCHARGED INTO | | ANY INTERCEPTOR OR SEPARATOR PER 2010 FBC-PLUMBING | | SEC.1003.2. | | 7)THE GREASE INTERCEPTOR SHALL HAVE THE GREASE | | RETENTION CAPACITY INDICATED IN TABLE 1003.3.4.1 OF | | FBC-PLUMBING FOR THE FLOW THROUGH RATES INDICATED. | | 8) GREASE INTTERCEPTORS SHALL BE EQUIPPED WITH DEVICES | | TO CONTROL THE RATE OF WATER FLOW SO THAT THE WATER | | FLOW DOES NOT EXCEED THE RATED FLOW PER FBC-PLUMBING | | SEC.1003.3.4.2. | | 9) INDICATE THE TYPE OF COOKING OPERATIONS THAT WILL BE | | DONE IN THE STRUCTURE.WPB AMEND. TO FBC SEC. 107.2.1. | | 10) SUBMIT A WATER RISER FOR REVIEW. WPB AMEND. TO FBC | | SEC. 107.3.5.1.3. | | | | WHEN A COMPLETE SET OF PLANS ARE SUBMITTED THAT SHOW | | ALL THE CHANGES TO THE BUILDING, ELECTRICAL, MECHANICAL | | AND PLUMBING SYSTEMS THOSE PLANS WILL BE REVIEWED BY | | EACH DISCIPLINE. THE PLANS MUST BE SUBMITTED AS A | | COMPLETE PACKAGE. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-02-29 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-02-29 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-02-29 |
Time |
14:38 |
Sent To |
|
|
Notes |
2016-02-29 14:50:42 | PROVISO: ANY NEW MECHANICAL EQUIPMENT ON THE ROOF SHALL | | BE SCREENED WITH A WALL, LOUVER OR SIMILAR IN THE SAME | | HEIGHT OF THE EQUIPMENT. | | ESTABLISHMENT SHALL FOLLOW THE ALCOHOL REGULATION IN | | CHAPTER VI OF THE CITY CODE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-12-22 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-12-22 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-12-22 |
Time |
16:20 |
Sent To |
E |
|
Notes |
2015-12-22 16:20:38 | ALCOHOL RESTRICTIONS APPLY. |
|
|