Plan Review Stops For Permit 15090611 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2016-05-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-05-06 |
Time |
07:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-05-06 |
Time |
06:25 |
Sent To |
|
|
Notes |
2016-05-06 07:00:33 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15090611 | | ADD: 4912 S DIXIE | | CONT: LEIGHTON MCGINN | | TEL: (561)863-4455 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3. COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 5TH REVIEW | | DATE: FRI. MAY 06/ 2016 | | ACTION: BUILDING PROVISO | | | | | | 1) BUILDING PROVISO: CLIP ENGINEERING TO BE A DEFERRED | | SUBMITTAL: | | SUBMITTED PRODUCT WITH (2) SETS OF PRODUCT APPROVALS | | REVIEWED BY DESIGNER OF RECORD: | | THYBAR TC-5 STEEL ROOF CURB FOR CARRIER ROOFTOP UNITS | | NOA15-0218.11, PLEASE NOTE TECH PAGE 5 OF 5. RESTRAINT | | BRACKET QUANTITY IS DETERMINED BY PROJECT SPECIFIC | | CALCULATIONS, PERFORMED BY A FLORIDA LICENSED PE OR | | FLORIDA REGISTERED ARCHITECT THAT CONSIDER THE UNIQUE | | COMBINATION OF THE UNIT SIZE AND APPLICABLE LATERAL AND | | UPLIFT PRESSURES FOR EACH JOB. PLEASE PROVIDE | | CALCULATION FOR HOW MANY BRACKETS WILL BE NEEDED FOR | | EACH TYPE OF UNIT. | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2) BUILDING PROVISO: SEE SHEET A1.6 NEW ROOF HATCH FOR | | 2ND STORY ROOF, MISSING ON THE STRUCTURAL SHEET S3.0, | | WILL NEED A REVISION SHOWING STRUCTURAL ROOF FRAMING | | FOR THE ROOF HATCH. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2016-02-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-02-27 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-02-27 |
Time |
05:17 |
Sent To |
|
|
Notes |
2016-02-27 08:28:45 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15090611 | | ADD: 4912 S DIXIE | | CONT: LEIGHTON MCGINN | | TEL: (561)863-4455 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3. COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 4TH REVIEW | | DATE: SAT. FEB. 27/ 2016 | | ACTION: DENIED | | | | NOTE: NEW DESIGN. THE RESPONSE COMMENTS INDICATE THE | | PLANNED CONCEPT HAS CHANGED, THE ADDITION OF A | | MEZZANINE LEVEL AND WORK WITHIN THE 2ND FLOOR R3 | | OCCUPANCY. THE CONTRACTOR HAS NOT SHOWN AN INCREASE IN | | SCOPE ON THE APPLICATION NOR HAS THE DOLLAR AMOUNT | | INCREASE FOR THE ADDITIONAL WORK!!!!! | | | | 1-5) COMPLIED | | | | 6) 2ND REQUEST. THE SHEET A5.1 THE CLEAR STORY WINDOWS | | HAVE BEEN REMOVED FROM THE PLANS. ON SHEET A1.1 THE | | NORTH CLEAR STORY WINDOWS STILL SHOW ON THE PLANS AS | | WELL DOES A NOTE FOR THESE WINDOWS ON THE WEST AND | | NORTH FACES OF THE BUILDING. THE STRUCTURAL SHEET S-1 | | HAS NOT BEEN UPDATED AND THE CLEAR STORY WINDOWS | | REMOVED. 2014 FBC-B TABLE 602 & 705.8.4 | | FROM THE PREVIOUS ROUND OF REVIEWS. SHEET LS1 THE CODE | | ANALYSIS WILL NEED TO PROVIDE THE TRIBUTARY AREA OF | | WALL AREA BEING CONSIDERED, FACING THE NORTH ELEVATION. | | IT APPEARS THERE IS APPROXIMATELY 508 SQ. FT. OF WALL | | AREA, (DO NOT INCLUDE PARAPET ABOVE THE ROOF LINE). 10% | | OF THE WALL WOULD ALLOW 50.8 SQ. FT. OF UNPROTECTED | | OPENINGS. FOR ADDITIONAL OPENINGS SEE FBC-B 705.8.4 FOR | | MIXED OPENINGS. | | 2014 FBC-B TABLE 602 FOR 10 FEET OR LESS REQUIRES A 1 | | HOUR FIRE RATED WALL AND PLEASE REVIEW ALLOWABLE | | OPENINGS IN TABLE 705.8 PROVIDE THE PERCENTAGE OF | | OPENINGS INDICATED IN THE NORTH WALL. | | | | 7)COMPLIED. THIS DETAIL MAY ALSO BE USED FOR OTHER THAN | | THE CLEAR STORY WINDOWS UNDER NEW OPENINGS IN EXISTING | | WALLS. | | | | 8-9) COMPLIED. SHEET A11.0 THE ROOF AND WALL PRESSURES | | ARE TAKEN AT 20 FEET PLEASE REVIEW SHEETS A5.0 AND A5.1 | | INDICATE THE ROOF HEIGHT AT 22FEET. | | | | 10) SEMI- COMPLIED. 2010 FBC-B 1609.1.2 PROTECTION OF | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3. | | | | SUBMITTED PRODUCTS WITH (2) SETS OF PRODUCT APPROVALS | | REVIEWED BY DESIGNER OF RECORD: | | TRULITE 3000 REGISTER STOREFRONT L.M.I. NOA 14-0203.01 | | NANA WALL SL-73 OUTSWING FOLDING DOORS L.M.I. NOA | | 15-0226.05 | | SCHAUGE LOCK CO. NOA 13-1217.16 | | OVERHEAD DOOR CORP. NOA 13-1121.06 | | MAXIM INDUSTRIES DCM CURB MOUNT SKYLIGHT NOA 14-0318.01 | | TREMCO MODIFIED BITUMEN NOA 11-0301.02 | | | | SUBMITTED PRODUCT WITH (2) SETS OF PRODUCT APPROVALS | | REVIEWED BY DESIGNER OF RECORD: | | THYBAR TC-5 STEEL ROOF CURB FOR CARRIER ROOFTOP UNITS | | NOA15-0218.11, PLEASE NOTE TECH PAGE 5 OF 5. RESTRAINT | | BRACKET QUANTITY IS DETERMINED BY PROJECT SPECIFIC | | CALCULATIONS, PERFORMED BY A FLORIDA LICENSED PE OR | | FLORIDA REGISTERED ARCHITECT THAT CONSIDER THE UNIQUE | | COMBINATION OF THE UNIT SIZE AND APPLICABLE LATERAL AND | | UPLIFT PRESSURES FOR EACH JOB. PLEASE PROVIDE | | CALCULATION FOR HOW MANY BRACKETS WILL BE NEEDED FOR | | EACH TYPE OF UNIT. | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. | | | | SUBMITTED PRODUCTS WITH (1) SET OF PRODUCT APPROVALS | | REVIEWED BY DESIGNER OF RECORD: | | FL16132-R1 TM WINDOWS/ CASEMENT | | FL16921-R2 PRECESION ALUMINUM PRODUCTS -PRE-ENGINEERED | | A/C STANDS | | FL16554-R3 YKK AP AMERICA SWINGING EXTERIOR DOOR | | ASSEMBLIES | | | | 11) COMPLIED. REQUIREMENT FOR AT LEAST ONE WINDOW IN | | EACH SLEEPING ROOM COMPLY WITH 1029.1 & 1029.2. | | | | 12-16) COMPLIED. | | | | 17-18) COMPLIED. 61G15-23.001 / 61G15-23.002(2) FL. | | ADMINISTRATIVE CODE. | | | | 19) COMPLIED. IMPACT FEES. | | | | 20) NEW COMMENT, THE SHEET S1.0 AND S2.0 DRAWINGS HAVE | | NOT BEEN UPDATED TO THE NEW WINDOW AND DOOR LAYOUT. | | THEY STILL SHOW THE CLEAR STORY OPENINGS, THE OTHER | | ISSUE IS IN THE SOUTHEAST AREA OF THE 2 STORY PORTION | | OF THE BUILDING, THE STRUCTURAL SHEETS HAVE NOT BEEN | | UPDATED TO REFLECT THE NEW WINDOW AND DOOR LAYOUT ON | | THE 1ST AND 2ND FLOOR. DISCREPANCY IN PLANS. 107.2.1.3 | | ADDITIONAL INFORMATION IS REQUIRED. | | | | 21)NEW COMMENT. SHEET A1.6 ROOF TOP PLAN. ON THE NEW | | MEZZANINE LEVEL THE PLANS SHOW AN EXTERIOR DOOR THAT | | CAN BE USED TO GAIN ACCESS FOR SERVICING AND OR | | REPLACEMENT OF ROOF TOP MECHANICAL EQUIPMENT BUT THE | | PLANS DO NOT SHOW HOW ACCESS TO THE 2ND STORY ROOF FOR | | SERVICING OF THE MECHANICAL ROOF TOP EQUIPMENT. | | 2014 FBC-B ? 1509.6.4 EQUIPMENT AND APPLIANCES ON ROOFS | | OR ELEVATED STRUCTURES. | | WHERE EQUIPMENT AND APPLIANCES REQUIRING ACCESS ARE | | INSTALLED ON ROOFS OR ELEVATED STRUCTURES AT A HEIGHT | | EXCEEDING 16 FEET (4877 MM), SUCH ACCESS SHALL BE | | PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS, THE | | EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL TO | | THE EQUIPMENT AND APPLIANCES? LEVEL SERVICE SPACE. SUCH | | ACCESS SHALL NOT REQUIRE CLIMBING OVER OBSTRUCTIONS | | GREATER THAN 30 INCHES (762 MM) HIGH OR WALKING ON | | ROOFS HAVING A SLOPE GREATER THAN 4 UNITS VERTICAL IN | | 12 UNITS HORIZONTAL (33-PERCENT SLOPE). | | PERMANENT LADDERS INSTALLED TO PROVIDE THE REQUIRED | | ACCESS SHALL COMPLY WITH THE FOLLOWING MINIMUM DESIGN | | CRITERIA: | | 1. THE SIDE RAILING SHALL EXTEND ABOVE THE PARAPET OR | | ROOF EDGE NOT LESS THAN 30 INCHES (762 MM). | | 2. LADDERS SHALL HAVE RUNG SPACING NOT TO EXCEED 14 | | INCHES (356 MM) ON CENTER. | | 3. LADDERS SHALL HAVE A TOE SPACING NOT LESS THAN | | 6-INCHES (152 MM) DEEP. | | 4. THERE SHALL BE A MINIMUM OF 18 INCHES (457 MM) | | BETWEEN RAILS. | | 5. RUNGS SHALL HAVE A MINIMUM 0.75-INCH (19 MM) | | DIAMETER AND BE CAPABLE OF WITHSTANDING A 300-POUND | | (136.1 KG) LOAD. | | 6. LADDERS OVER 30 FEET (9144 MM) IN HEIGHT SHALL BE | | PROVIDED WITH OFFSET SECTIONS AND LANDINGS CAPABLE OF | | WITHSTANDING 100 POUNDS PER SQUARE FOOT (488.2 KG/M2). | | 7. LADDERS SHALL BE PROTECTED AGAINST CORROSION BY | | APPROVED MEANS. CATWALKS INSTALLED TO PROVIDE THE | | REQUIRED ACCESS SHALL BE NOT LESS THAN 24-INCHES (610 | | MM) WIDE AND SHALL HAVE RAILINGS AS REQUIRED FOR | | SERVICE PLATFORMS . | | | | 22) NEW COMMENT. SHEET A11.0 SHOWS VARIOUS DETAILS FOR | | ROOF TOP MECHANICAL EQUIPMENT AND SKYLIGHT ATTACHMENTS | | BUT THESE ARE GENERAL DETAILS. THERE ARE NO STRUCTURAL | | DETAILS PROVIDING THE SIZE OF MATERIALS, | | IF CURBS ARE TO BE WELDED TO STRUCTURAL MEMBERS, SCREED | | OR BOLTED. THERE ARE ALSO NO DETAILS OF HOW THE ROOF | | TOP A/C UNITS WILL BE ANCHORED. 2014 FBC-M - 301.15 | | WIND RESISTANCE. MECHANICAL EQUIPMENT, APPLIANCES AND | | SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED AND | | INSTALLED TO RESIST THE WIND PRESSURES DETERMINED IN | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING. | | | | 23) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-01-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-01-13 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-01-13 |
Time |
07:30 |
Sent To |
|
|
Notes |
2016-01-13 12:31:50 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15090611 | | ADD: 4912 S DIXIE | | CONT: LEIGHTON MCGINN | | TEL: (561)863-4455 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3. COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: WED. JAN. 13/ 2016 | | ACTION: DENIED | | | | NOTE: NEW DESIGN. THE RESPONSE COMMENTS INDICATE THE | | PLANNED CONCEPT HAS CHANGED, THE ADDITION OF A | | MEZZANINE LEVEL AND WORK WITHIN THE 2ND FLOOR R3 | | OCCUPANCY. THE CONTRACTOR HAS NOT SHOWN AN INCREASE IN | | SCOPE ON THE APPLICATION NOR HAS THE DOLLAR AMOUNT | | INCREASE FOR THE ADDITIONAL WORK!!!!! | | | | 1-5) COMPLIED | | | | 6) SHEET LS1 THE CODE ANALYSIS WILL NEED TO PROVIDE THE | | TRIBUTARY AREA OF WALL AREA BEING CONSIDERED, FACING | | THE NORTH ELEVATION. IT APPEARS THERE IS APPROXIMATELY | | 508 SQ. FT. OF WALL AREA, (DO NOT INCLUDE PARAPET ABOVE | | THE ROOF LINE). 10% OF THE WALL WOULD ALLOW 50.8 SQ. | | FT. OF UNPROTECTED OPENINGS. FOR ADDITIONAL OPENINGS | | SEE FBC-B 705.8.4 FOR MIXED OPENINGS. | | 2014 FBC-B TABLE 602 FOR 10 FEET OR LESS REQUIRES A 1 | | HOUR FIRE RATED WALL AND PLEASE REVIEW ALLOWABLE | | OPENINGS IN TABLE 705.8 PROVIDE THE PERCENTAGE OF | | OPENINGS INDICATED IN THE NORTH WALL. | | | | 7) SHEET A5.0 & A5.1 SHOW NEW CLEARSTORY WINDOW | | OPENINGS (NOTE # 3) WITHIN THE BLOCK WALL BUT THERE ARE | | NO DETAILS AS TO HOW THE BLOCK ABOVE THE NEW OPENING | | WILL BE HELD IN PLACE. THE STRUCTURAL SHEETS S1 NOR S2 | | DEPICT THESE WINDOWS. NO LINTELS OR BEAMS AND COLUMNS | | FOUND ON THE STRUCTURAL SHEETS, PART OF THE MAIN WIND | | FORCE RESISTING SYSTEM. | | | | SHEET S1.0 IN THE NORTH WALL APPEARS TO HAVE OTHER | | OPENING LOCATIONS IN THE WALL VERSES THE CLEARSTORY | | WINDOW OPENINGS. | | | | 8-9) COMPLIED. SHEET A11.0 THE ROOF AND WALL PRESSURES | | ARE TAKEN AT 20 FEET PLEASE REVIEW SHEETS A5.0 AND A5.1 | | INDICATE THE ROOF HEIGHT AT 22FEET. | | | | 10) SEMI- COMPLIED. 2010 FBC-B 1609.1.2 PROTECTION OF | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS. OVERHEAD DOORS, METAL CLAD OR | | SOLID EXTERIOR WOOD DOORS. | | (B) WINDOWS COMPLIED. | | (C) STOREFRONTS, , WALL LOUVERS, COMPLIED. | | (D) ROOFING PRODUCTS AND ASSEMBLIES SUBMITTED NOT | | REVIEWED, SPACING OF BAR JOIST NOT SUBMITTED. | | SKYLIGHTS: COMPLIED. | | ROOFTOP A/C STANDS. COMPLIED. | | NEW INTAKE & EXHAUST FAN CURBS : NO SUBMITTALS | | ROOF TOP A/C CURBS: NO SUBMITTALS | | | | 11) COMPLIED. REQUIREMENT FOR AT LEAST ONE WINDOW IN | | EACH SLEEPING ROOM COMPLY WITH 1029.1 & 1029.2. | | | | 12) SHEET A6.1 INDICATES NEW EXTERIOR STAIRS BUT THERE | | IS NO DESIGN CRITERIA FOR THE FABRICATOR. 2014 FBC-B | | TABLE 1607.1. SHEET S4.0 DESIGN LOAD SCHEDULE DOES NOT | | SHOW THE LIVE LOADS FOR THE 2ND FLOOR R3 RESIDENTIAL | | UNIT, STORAGE MEZZANINE LIGHT OR HEAVY NOR THE EXTERIOR | | STAIRS. | | | | 14) ENERGY COMPLIANCE FORM: SEE MECHANICAL COMMENTS. | | | | 15) SITE PLAN: THE NEW ACCESSIBLE PARKING ON THE EAST | | SIDE OF THE BUILDING WILL MEET THE WIDTH AND LENGTH | | ELEMENTS FOR BOTH THE PARKING SPACE AND ACCESS AISLE. | | THE MARKING OF SUCH SPACES IS TO COMPLY WITH 2014 | | ACCESSIBILITY CODE 502.3.3. SEE W.P.B. MUNI CODE | | 94-485. | | PROVISO: TO BE A JOBSITE CONDITION: 502.4.SLOPES NOT | | GREATER THAN 1:48 SHALL BE PERMITTED. | | | | 16) NEW COMMENTS: SHEET S.1: | | 16A) VERTICAL REBAR SPACING FOR THE 1ST FLOOR IS | | PROVIDED BY WALL TYPE TAGS SEE S.4 BUT THERE IS NO WALL | | IDENTIFICATION TAGS FOUND ON SHEETS S.2 OR S.3? | | ADDITIONAL INFORMATION IS REQUIRED, 107.2.1.3. PART OF | | THE MWFRS (MAIN WIND FORCE RESISTING SYSTEM). | | | | 16B) SHEET S1 THE STAIRS TO THE MEZZANINE LEVEL SHOW | | HIDDEN LINES AS IF BELOW FOR INSET EXTERIOR DOORS? | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | 17) NOTE ALL NEW STRUCTURAL SHEETS THE SIZE OF THE | | ENGINEERS SEAL IS ANYWHERE FROM 7/8 INCH IN DIAMETER TO | | APPROXIMATELY 1 3/8 INCHES IN DIAMETER. | | 61G15-23.001 ENGINEERS SEALS ACCEPTABLE TO THE BOARD. | | SAID SEAL SHALL BE A MINIMUM OF 1 7/8 INCHES IN | | DIAMETER, TO SAY LICENSE NOT CERTIFICATE. ALL ENGINEERS | | MUST BE UTILIZING SAID SEAL NO LATER THAN JANUARY 1, | | 2006. | | | | 18) ALL NEW STRUCTURAL SHEETS, THE ENGINEERS SIGNATURE, | | IS A COPIED SIGNATURE ON ALL OF THE SHEETS. | | 61G15-23.002(2) FL. ADMIN. CODE. | | | | 19) ADDITIONAL SQUARE FOOTAGE IS BEING ADDED, IMPACT | | FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, | | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE | | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 20) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-11-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-11-25 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-11-25 |
Time |
08:35 |
Sent To |
|
|
Notes |
2015-11-25 09:44:40 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15090611 | | ADD: 4912 S DIXIE | | CONT: LEIGHTON MCGINN | | TEL: (561)863-4455 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3. COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: WED. NOV. 25/ 2015 | | ACTION: DENIED | | | | NONE OF THE COMMENTS ADDRESSED FROM 1ST REVIEW. | | NOTICE!!!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA | | STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A | | FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE | | REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO | | CORRECT A CODE VIOLATION. | | | | NO RESPONSE SHEET TO THE COMMENTS ASKED!!!!!!!!!!!!! | | | | | | 1) THE SHEET LS.1 LIST THE BUILDING TYPE AS A VB- | | UNSPRINKLERED. THE OCCUPANCY TYPES LISTED ARE ASSEMBLY, | | BUSINESS & RESIDENTIAL BUT THE PLANS DO NOT INDICATE | | THE SQUARE FOOTAGE OF EACH OF THE OCCUPANCIES AND | | COMPLIANCE WITH 2014 FBC-B 508.2.1 AREA LIMITATIONS / | | MIXED OCCUPANCIES. | | | | 2)SHEET LS1 DOES NOT LIST IF THE BUILDING WAS DESIGNED | | AS SEPERATED OR NON-SEPARATED OCCUPANCIES BETWEEN THE | | ASSEMBLY AND BUSINESS OCCUPANCIES. 508.4.4 SEPARATE | | OCCUPANCIES OR 508.3.3 NON-SEPARATED. | | | | 3) SHEET LS1 ALSO LIST A RESIDENTIAL R2 OCCUPANCY BUT | | APPEARS TO BE A SINGLE DWELLING UNIT WITH 2 BEDROOMS. | | NOTE WHEN YOU LOOK AT SECTION 310.4 R2 IT IS FOR MORE | | THAN EITHER 2 SLEEPING UNITS OR 2 DWELLING UNITS. THE | | RESIDENTIAL UNIT ON THE 2ND FLOOR IS ACTUALLY A R3, | | PRIMARILY PERMANENT IN NATURE AND NOT CLASSIFIED AS | | GROUP R-1, R-2, R-4 OR I. NOTE THIS IS A MIXED USE | | OCCUPANCY, THE RESIDENTIAL UNIT IS CONSIDERED A R3. | | | | 4) SHEET LS1 LIST TABLE 601 FIRE RESISTANCE RATINGS FOR | | BUILDING ELEMENTS, TYPE 5B UNDER THE FLOOR ELEMENT | | THERE IS NO REQUIREMENT FOR FIRE RATING BUT THERE IS NO | | MENTION IN THE CODE DATE REQUIREMENTS FOR HORIZONTAL | | ASSEMBLIES BETWEEN FIRE AREAS ( OCCUPANCIES) SEE TABLE | | 707.3.10 (2 HR.) BETWEEN BUSINESS AND RESIDENTIAL. | | | | 5) DISCREPANCY IN PLANS, UNDER PERMIT 15070711/ | | REVISION 15080905 SHEET D1.1 NOTE # 23 INDICATED A | | SECTION OF ROOFINGAND ROOF STRUCTUREALONG WITH WOOD | | FRAMING STRUCTURE, INCLUDES PLASTER AND FRAMING. SHEET | | A1.2 THE SECOND FLOOR PLAN & ROOF PLAN NOTE # 4 ROOF TO | | REMAIN. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | SHEET A6.0 DETAIL # 2 DOES NOT INDICATE WHAT TYPE OF | | ROOF FRAMING IS LOCATED IN THE SOUTH PORTION OF THE ONE | | STORY BUILDING. | | | | 6) SHEET LS1 THE CODE ANALYSIS DOES NOT PROVIDE ANY | | INFORMATION FOR THE NORTH WALL OF THE BUILDING OR THE | | REQUIRED FIRE RATING SEE 2014 FBC-B TABLE 602 FOR 10 | | FEET OR LESS REQUIRES A 1 HOUR FIRE RATED WALL AND | | PLEASE REVIEW ALLOWABLE OPENINGS IN TABLE 705.8 PROVIDE | | THE PER CENTAGE OF OPENINGS INDICATED IN THE NORTH | | WALL. | | | | 7) SHEET LS1 THE NORTH & WEST WALLS INDICATES NEW | | WINDOW OPENINGS (NOTE # 3) WITHIN THE BLOCK WALL BUT | | THERE ARE NO DETAILS AS TOHOW THE BLOCK ABOVE THE NEW | | OPENING WILL BE HELD IN PLACE. NO LINTELS OR BEAMS AND | | COLUMNS FOUND ON SHEET A11.0. PART OF THE MAIN WIND | | FORCE RESISTING SYSTEM. | | | | 8) SHEET A11.0 THE ROOF AND WALL PRESSURES ARE TAKEN AT | | 20 FEET PLEASE REVIEW SHEETS A5.0 AND A5.1 INDICATE THE | | ROOF HEIGHT AT 22FEET. THE OTHER ISSUE WITH THE | | PRESSURES ARE IN ZONE 3 THE PRESSURES ARE TAKEN AS IF | | THERE IS A 3'-0" PARAPET AROUND THE BUILDING, WHICH | | THERE IS NOT. PBC PICTOMETY DOES NOT SHOW 3'-0" | | PARAPETS. FBC-B 1609. 6.2 . | | | | 9) SHEET A1.1 SHOWS A DETAIL FOR NEW EXTERIOR METAL | | STAIRS. IN BOTH SHEETS A1.1, AND A5.1 THE PLANS SHOW | | WINDOWS AND DOORS DIRECTLY IN FRONT OF THE EXTERIOR | | STAIRCASE, THIS IS THE ONLY MEANS OF EGRESS FROM THE | | 2ND FLOOR R-3 OCCUPANCY. PLEASE REVIEW 2014 FBC-B | | 1026.6 ALSO REVIEW THE 2012 IBC BASE CODE FIGURE | | 1026.6(1) NOTE OPENINGS SHALL BE LIMITED TO THOSE | | NECESSARY FOR EGRESS FROM NORMALLY OCCUPIED SPACES, NO | | WINDOWS ALLOWED 1ST FLOOR OR 2ND FLOOR. | | | | 10) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS RULE 9N-3 | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS. OVERHEAD DOORS, STOREFRONT | | DOORS, METAL CLAD OR SOLID EXTERIOR WOOD DOORS. | | (B) WINDOWS 2ND FLOOR EGRESS WINDOWS SHEET A5.0 & A5.1 | | NOTE 2 INDICATES NEW STOREFRONT | | (C) STOREFRONTS, CURTAIN WALLS, WALL LOUVERS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES REPAIRS FOR AROUND | | SKYLIGHTS AND NEW INTAKE & EXHAUST FAN CURBS | | | | 11) THE PLANS SHEETS A5.0 & A5.1 BOTH INDICATE WITH | | NOTE # 2 NEW STOREFRONT WINDOWS IN THE R3 RESIDENCE. | | PLEASE REVIEW 2014 FBC-B 1029 THE REQUIREMENT FOR AT | | LEAST ONE WINDOW IN EACH SLEEPING ROOM COMPLY WITH | | 1029.1 & 1029.2. | | | | 12) SHEET A6.1 INDICATES NEW EXTERIOR STAIRS BUT THERE | | IS NO DESIGN CRITERIA FOR THE FABRICATOR. 2014 FBC-B | | TABLE 1607.1. | | | | 14) ENERGY COMPLIANCE FORM: | | 14A) THE ENERGY DATA REPORT HAS NOT BEEN FILED IN, CAN | | NOT VERIFY COMPLIANCE WITH THE PERSCRIPTIVE METHOD. | | | | 14B) SHEETS 7-12 THE MANDATORY REQUIREMENTS HAVE NOT | | BEEN FILED IN YES, N/A OR EX. | | | | 14C) 2014 FBC-ENERGY C101.4.6 WHERE A BUILDING INCLUDES | | BOTH RESIDENTIAL AND COMMERCIAL OCCUPANCIES, EACH | | OCCUPANCY SHALL BE SEPARATELY CONSIDERD AND MEET THE | | APPLICABLE PROVISIONS OF THE COMMERCIAL PROVISONS OR | | RESIDENTIAL PROVISIONS OF THIS CODE. | | | | 15) SITE PLAN: | | 15A) THE SITE PLAN INDICATES THE ACCESSIBLE PARKING | | SPACE ON THE SOUTH SIDE OF THE BUILDING AND BOTH THE | | ACCESSIBLE PARKING SPACE AND ACCESS AISLE CONTINUE PAST | | THE PROPERTY LINE INTO THE RIGHT OF WAY. | | 2014 FBC-ACCESSIBLITY CODE 502.3.2 LENGTH | | | | 15B) THE SECOND ISSUE IS FROM THE ACCESSIBLE PARKING | | SPACE AND ADJACENT ACCESS AISLE THERE IS 4'-0" FROM THE | | CAR STOP TO THE BUILDING. WITH A 2'-0" OVERHANG OF THE | | CAR THERE IS ONLY 2'-0" FRONT OF THE CAR TO THE WALL | | LINE OF THE STRUCTURE. NOT ENOUGH CLEARANCE FOR AN | | ACCESSIBLE PATH TO THE ACCESSIBLE ENTRANCE. 2014 | | FBC-ACC. CODE 206.2.2 WITHIN THE SITE. | | | | 16) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-09-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-09-25 |
Time |
12:27 |
Rev Time |
|
Received By |
jwitmer |
Date |
2015-09-24 |
Time |
07:31 |
Sent To |
|
|
Notes |
2015-09-24 14:07:59 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15090611 | | ADD: 4912 S DIXIE | | CONT: LEIGHTON MCGINN | | TEL: (561)863-4455 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3. COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. SEPT. 24/ 2015 | | ACTION: DENIED | | | | 1) THE SHEET LS.1 LIST THE BUILDING TYPE AS A VB- | | UNSPRINKLERED. THE OCCUPANCY TYPES LISTED ARE ASSEMBLY, | | BUSINESS & RESIDENTIAL BUT THE PLANS DO NOT INDICATE | | THE SQUARE FOOTAGE OF EACH OF THE OCCUPANCIES AND | | COMPLIANCE WITH 2014 FBC-B 508.2.1 AREA LIMITATIONS / | | MIXED OCCUPANCIES. | | | | 2)SHEET LS1 DOES NOT LIST IF THE BUILDING WAS DESIGNED | | AS SEPERATED OR NON-SEPARATED OCCUPANCIES BETWEEN THE | | ASSEMBLY AND BUSINESS OCCUPANCIES. 508.4.4 SEPARATE | | OCCUPANCIES OR 508.3.3 NON-SEPARATED. | | | | 3) SHEET LS1 ALSO LIST A RESIDENTIAL R2 OCCUPANCY BUT | | APPEARS TO BE A SINGLE DWELLING UNIT WITH 2 BEDROOMS. | | NOTE WHEN YOU LOOK AT SECTION 310.4 R2 IT IS FOR MORE | | THAN EITHER 2 SLEEPING UNITS OR 2 DWELLING UNITS. THE | | RESIDENTIAL UNIT ON THE 2ND FLOOR IS ACTUALLY A R3, | | PRIMARILY PERMANENT IN NATURE AND NOT CLASSIFIED AS | | GROUP R-1, R-2, R-4 OR I. NOTE THIS IS A MIXED USE | | OCCUPANCY, THE RESIDENTIAL UNIT IS CONSIDERED A R3. | | | | 4) SHEET LS1 LIST TABLE 601 FIRE RESISTANCE RATINGS FOR | | BUILDING ELEMENTS, TYPE 5B UNDER THE FLOOR ELEMENT | | THERE IS NO REQUIREMENT FOR FIRE RATING BUT THERE IS NO | | MENTION IN THE CODE DATE REQUIREMENTS FOR HORIZONTAL | | ASSEMBLIES BETWEEN FIRE AREAS ( OCCUPANCIES) SEE TABLE | | 707.3.10 (2 HR.) BETWEEN BUSINESS AND RESIDENTIAL. | | | | 5) DISCREPANCY IN PLANS, UNDER PERMIT 15070711/ | | REVISION 15080905 SHEET D1.1 NOTE # 23 INDICATED A | | SECTION OF ROOFINGAND ROOF STRUCTUREALONG WITH WOOD | | FRAMING STRUCTURE, INCLUDES PLASTER AND FRAMING. SHEET | | A1.2 THE SECOND FLOOR PLAN & ROOF PLAN NOTE # 4 ROOF TO | | REMAIN. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | SHEET A6.0 DETAIL # 2 DOES NOT INDICATE WHAT TYPE OF | | ROOF FRAMING IS LOCATED IN THE SOUTH PORTION OF THE ONE | | STORY BUILDING. | | | | 6) SHEET LS1 THE CODE ANALYSIS DOES NOT PROVIDE ANY | | INFORMATION FOR THE NORTH WALL OF THE BUILDING OR THE | | REQUIRED FIRE RATING SEE 2014 FBC-B TABLE 602 FOR 10 | | FEET OR LESS REQUIRES A 1 HOUR FIRE RATED WALL AND | | PLEASE REVIEW ALLOWABLE OPENINGS IN TABLE 705.8 PROVIDE | | THE PER CENTAGE OF OPENINGS INDICATED IN THE NORTH | | WALL. | | | | 7) SHEET LS1 THE NORTH & WEST WALLS INDICATES NEW | | WINDOW OPENINGS (NOTE # 3) WITHIN THE BLOCK WALL BUT | | THERE ARE NO DETAILS AS TOHOW THE BLOCK ABOVE THE NEW | | OPENING WILL BE HELD IN PLACE. NO LINTELS OR BEAMS AND | | COLUMNS FOUND ON SHEET A11.0. PART OF THE MAIN WIND | | FORCE RESISTING SYSTEM. | | | | 8) SHEET A11.0 THE ROOF AND WALL PRESSURES ARE TAKEN AT | | 20 FEET PLEASE REVIEW SHEETS A5.0 AND A5.1 INDICATE THE | | ROOF HEIGHT AT 22FEET. THE OTHER ISSUE WITH THE | | PRESSURES ARE IN ZONE 3 THE PRESSURES ARE TAKEN AS IF | | THERE IS A 3'-0" PARAPET AROUND THE BUILDING, WHICH | | THERE IS NOT. PBC PICTOMETY DOES NOT SHOW 3'-0" | | PARAPETS. FBC-B 1609. 6.2 . | | | | 9) SHEET A1.1 SHOWS A DETAIL FOR NEW EXTERIOR METAL | | STAIRS. IN BOTH SHEETS A1.1, AND A5.1 THE PLANS SHOW | | WINDOWS AND DOORS DIRECTLY IN FRONT OF THE EXTERIOR | | STAIRCASE, THIS IS THE ONLY MEANS OF EGRESS FROM THE | | 2ND FLOOR R-3 OCCUPANCY. PLEASE REVIEW 2014 FBC-B | | 1026.6 ALSO REVIEW THE 2012 IBC BASE CODE FIGURE | | 1026.6(1) NOTE OPENINGS SHALL BE LIMITED TO THOSE | | NECESSARY FOR EGRESS FROM NORMALLY OCCUPIED SPACES, NO | | WINDOWS ALLOWED 1ST FLOOR OR 2ND FLOOR. | | | | 10) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS RULE 9N-3 | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS. OVERHEAD DOORS, STOREFRONT | | DOORS, METAL CLAD OR SOLID EXTERIOR WOOD DOORS. | | (B) WINDOWS 2ND FLOOR EGRESS WINDOWS SHEET A5.0 & A5.1 | | NOTE 2 INDICATES NEW STOREFRONT | | (C) STOREFRONTS, CURTAIN WALLS, WALL LOUVERS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES REPAIRS FOR AROUND | | SKYLIGHTS AND NEW INTAKE & EXHAUST FAN CURBS | | | | 11) THE PLANS SHEETS A5.0 & A5.1 BOTH INDICATE WITH | | NOTE # 2 NEW STOREFRONT WINDOWS IN THE R3 RESIDENCE. | | PLEASE REVIEW 2014 FBC-B 1029 THE REQUIREMENT FOR AT | | LEAST ONE WINDOW IN EACH SLEEPING ROOM COMPLY WITH | | 1029.1 & 1029.2. | | | | 12) SHEET A6.1 INDICATES NEW EXTERIOR STAIRS BUT THERE | | IS NO DESIGN CRITERIA FOR THE FABRICATOR. 2014 FBC-B | | TABLE 1607.1. | | | | 14) ENERGY COMPLIANCE FORM: | | 14A) THE ENERGY DATA REPORT HAS NOT BEEN FILED IN, CAN | | NOT VERIFY COMPLIANCE WITH THE PERSCRIPTIVE METHOD. | | | | 14B) SHEETS 7-12 THE MANDATORY REQUIREMENTS HAVE NOT | | BEEN FILED IN YES, N/A OR EX. | | | | 14C) 2014 FBC-ENERGY C101.4.6 WHERE A BUILDING INCLUDES | | BOTH RESIDENTIAL AND COMMERCIAL OCCUPANCIES, EACH | | OCCUPANCY SHALL BE SEPARATELY CONSIDERD AND MEET THE | | APPLICABLE PROVISIONS OF THE COMMERCIAL PROVISONS OR | | RESIDENTIAL PROVISIONS OF THIS CODE. | | | | 15) SITE PLAN: | | 15A) THE SITE PLAN INDICATES THE ACCESSIBLE PARKING | | SPACE ON THE SOUTH SIDE OF THE BUILDING AND BOTH THE | | ACCESSIBLE PARKING SPACE AND ACCESS AISLE CONTINUE PAST | | THE PROPERTY LINE INTO THE RIGHT OF WAY. | | 2014 FBC-ACCESSIBLITY CODE 502.3.2 LENGTH | | | | 15B) THE SECOND ISSUE IS FROM THE ACCESSIBLE PARKING | | SPACE AND ADJACENT ACCESS AISLE THERE IS 4'-0" FROM THE | | CAR STOP TO THE BUILDING. WITH A 2'-0" OVERHANG OF THE | | CAR THERE IS ONLY 2'-0" FRONT OF THE CAR TO THE WALL | | LINE OF THE STRUCTURE. NOT ENOUGH CLEARANCE FOR AN | | ACCESSIBLE PATH TO THE ACCESSIBLE ENTRANCE. 2014 | | FBC-ACC. CODE 206.2.2 WITHIN THE SITE. | | | | 16) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2016-04-28 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-04-28 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-04-28 |
Time |
14:01 |
Sent To |
|
|
Notes |
2016-04-28 17:37:15 | ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN | | SATISFACTORILY ADDRESSED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2016-02-23 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-02-23 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-02-23 |
Time |
09:32 |
Sent To |
|
|
Notes |
2016-02-23 12:26:01 | 4TH ELECTRICAL REVIEW NOTES FOR PERMIT #: 15090611 | | | | REVIEWED FOR COMPLIANCE WITH: FBC 5TH EDITION 2014 & | | NFPA 70 2011 (NEC) | | | | I FOLLOWED THE SUBMITTED ELECTRICAL RESPONSE LETTER AND | | FOUND THAT THE PREVIOUSLY ADDRESSED COMMENTS HAVE BEEN | | SATISFIED, BUT BY ADDING THE LIGHTING FOR THE SECOND | | FLOOR THE FOLLOWING COMMENTS WERE GENERATED: | | 1. THIS ONE COMMENT APPLIES TO THE ENTIRE JOB. | | FBC-EC405.2.1.2 HAS LIGHT REDUCTION REQUIREMENTS WHICH | | HAVE NOT BEEN ADDRESSED. IN ADDITION TO LIGHT DIMMING, | | THERE ARE DAYLIGHT ZONES WHICH SHALL BE TAKEN INTO | | ACCOUNT AS WELL.. | | 2. YOU ARE INSTALLING CEILING FANS THEREFORE GENERATING | | COMPLIANCE WITH NEC 314.27(A),(B), & (C). | | 3. DEPENDING ON THE INTENDED WIRING METHOD, NEC | | 404.2(C) MAY REQUIRE THAT A GROUNDED CIRCUIT CONDUCTOR | | (NEUTRAL) BE PROVIDED AT THE SWITCH LOCATIONS. | | 4. THOUGH ALL EXTERIOR OUTLETS ARE MARKED AS WP AND | | GFCI NEC 406.9(B) REQUIRES THAT THE RECEPTACLES BE | | LISTED ?WEATHER RESISTANT? AS WELL. | | 5. IF AHU 1 IS INSIDE AN ATTIC, A LIGHT CONTROLLED VIA | | A WALL SWITCH (I SUGGEST IS BE OUTSIDE THE ATTIC IN A | | VISIBLE LOCATION AND HAVE A PILOT LIGHT), A SERVICE | | OUTLET AND A PERMANENT LADDER TO THE ATTIC WILL BE | | REQUIRED. SAME APPLIES FOR AHU 2. | | 6. YOU ARE MISSING EMERGENCY LIGHTS IN STORAGE 207 AND | | IN STAIRWAYS. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2016-01-26 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-01-26 |
Time |
19:00 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-01-26 |
Time |
13:00 |
Sent To |
|
|
Notes |
2016-01-26 19:02:54 | YOUR RESUBMITTAL ADDRESSING THE PREVIOUSLY MENTIONED | | DEFICIENCIES HAS ONCE AGAIN FAILED THE ELECTRICAL | | REVIEW AS INDICATED BELOW. NEW COMMENTS IF ANY PROMPTED | | BY ANOTHER REVIEW, MOST LIKELY DUE TO YOUR FAILURE TO | | SUBMIT A RESPONSE LETTER (NARRATIVE) ADDRESSING THE | | REQUIRED CORRECTIONS WILL BE NUMBERED IN CONTINUATION | | OF ANY PREVIOUS COMMENTS. THESE PLANS HAVE BEEN | | REVIEWED FOR COMPLIANCE WITH THE EDITION OF THE NEC, | | (NATIONAL ELECTRICAL CODE) AND THE FBC, (FLORIDA | | BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH | | AMENDMENTS IN EFFECT AT THE TIME OF SUBMITTAL. | | | | THE ELECTRICAL SHEET INDEX ON PAGE E0.1 INDICATES THAT | | CHANGES WERE ONLY MADE TO SHEETS E2.2 & E3.2. THE | | UNMENTIONED REVISION OF SHEET E2.1 PROMPTED ME TO | | CONDUCT A COMPLETE REVIEW OF THE PLANS TO CHECK FOR | | ADDITIONAL UNANNOUNCED CHANGES TO THE PLANS. BELOW ARE | | MY REMARKS TO YOUR RESPONSES ALONG WITH THE COMMENTS OF | | THIS REVIEW. | | | | 1. CORRECT ELECTRICAL SPECIFICATIONS P & Q TO READ | | FBC-EC405.7.3.2 AND FBC-EC405.7.3.1 RESPECTIVELY. | | 2. CORRECT GENERAL NOTES COMMERCIAL LIGHTING REFERENCE | | TO READ FBC-EC405. | | 3. SEE THE REMARKS TO YOUR RESPONSES: | | | | COMMENT 1: FIXTURE SCHEDULE OR LEGEND SHALL BE REVISED | | TO MATCH THE FLOOR PLANS MARKINGS. IT SHALL CLEARLY | | INDICATE THE EMERGENCY LIGHTING AS REQUIRED. | | | | THE LACK OF LUMINAIRE DATA MAKES IDENTIFICATION | | DIFFICULT, SO AS A NOTE ADHERE TO THE FBC-E C402.4.8 | | RECESSED LIGHTING. RECESSED LIGHTING INSTALLED IN THE | | BUILDING THERMAL ENVELOPE SHALL BE IC RATED AND BE | | SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED & | | UNCONDITIONED SPACES. | | | | COMMENT 2: ALL LIGHTING SHALL COMPLY WITH THE ENERGY | | CONSERVATION REQUIREMENTS FOR THE FBC. | | | | TO COMPLY WITH THE ENERGY CODE YOU SHALL SUBMIT A LIGHT | | DENSITY ALLOWANCE CHART SHOWING COMPLIANCE WITHIN THE | | ALLOWABLE LIGHTING ENERGY. | | | | COMMENT 3: PROVIDE A LIGHTING PLAN FOR THE 2ND FLOOR | | AREA. INCLUDE THE STAIRWAY ILLUMINATION AND SWITCHING | | REQUIREMENTS. | | | | THE SECOND FLOOR IS MISSING THE REQUIRED EXIT LIGHTS TO | | INDICATE THE PATH OF EGRESS. THE SECOND FLOOR IS | | MISSING THE REQUIRED EMERGENCY LIGHTING. THE STAIRWAY | | HAS NO ILLUMINATION AS REQUIRED BY BOTH FBC & NEC. | | | | COMMENT 4: NEC 210.62 HAS SPECIFIC SHOW WINDOW LIGHTING | | REQUIREMENTS NOT ALL OF WHICH HAVE BEEN COMPLIED WITH. | | YOU SHALL PROVIDE A SHOW WINDOW OUTLET FOR EVERY 12 | | LINEAR FOOT OR PORTION THEREFOF. NOT JUST A SELECTED | | SET OF WINDOWS. | | | | COMPLIED | | | | COMMENT 5: NEC 600.5 HAS SPECIFIC REQUIREMENTS FOR SIGN | | OUTLETS. IT CALLS FOR A DEDICATED SIGN OUTLET AT EVERY | | PEDESTRIAN ENTRY TO EVERY COMMERCIAL ESTABLISHMENT. | | THAT DOES NOT MEAN JUST THE FRONT/MAIN DOOR. | | | | YOU ARE TO PROVIDE THE REQUIRED SIGN OUTLETS, BUT FLOOR | | OUTLETS WERE NEVER MENTIONED FOR SIGNAGE. | | | | COMMENT 6: PROVIDE A POWER PLAN FOR THE 2ND FLOOR AREA. | | | | NEC 210.52 HAS SPECIFIC REQUIREMENTS FOR OUTLET | | PLACEMENTS. CHECK THE OUTLETS IN THE KITCHEN COUNTER | | AND BEDROOM 204. YOU INDICATE THE UPSTAIRS AHU AS BEING | | INSIDE THE ATTIC NEC 110.33(B) REQUIRES THAT THERE BE A | | PERMANENT LADDER TO ACCESS THE UNIT. FURTHERMORE, YOU | | ARE REQUIRED TO HAVE A SERVICE OUTLET AND PROPER | | LIGHTING. ALL RECEPTACLES IN THE SECOND FLOOR DWELLING | | SHALL BE TAMPER-RESISTANT AND BE AFCI PROTECTED AS | | INDICATED BY NEC 210.12 | | | | COMMENT 7: SHOW ON THE FLOOR PLAN THE ELECTRICAL | | OUTLETS OR POWER SOURCE FOR ALL THE WORK TABLES OR | | STATIONS. | | | | COMPLIED | | | | COMMENT 8: THE ADDITIONAL OUTLET WILL AFFECT THE | | ELECTRICAL LOAD CALCS AND MAYBE THE RISER DIAGRAM. | | CORRECT THOSE ACCORDINGLY. | | | | COMPLIED | | | | 4. IN ADDITION TO THE ABOVE, THERE DOES NOT APPEAR TO | | BE AMPLE LIGHTING ABOUT THE ELECTRICAL PANELS. NEC | | 110.26(D) REQUIRES THAT THERE BE AMPLE LIGHTING. | | 5. THERE ARE STILL MISSING EXIT SIGNS TO INDICATE THE | | PATHS OF EGRESS. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE | | NUMBER WHERE THE CORRECTIONS APPEAR ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | INSERT CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK | | VOID AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-12-30 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-30 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-12-30 |
Time |
14:45 |
Sent To |
I |
|
Notes |
2015-12-30 15:14:37 | 12/30/15 SEE ELECTRICAL REVIEW COMMENTS DATED 10/27/15, | | NONE OF WHICH HAVE BEEN ADDRESSED. PLEASE REVISE YOUR | | DRAWINGS TO REFLECT THE MENTIONED DEFICIENCIES. | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS MARKED VOID FOR COMPARISON. | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-10-27 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-10-27 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-10-27 |
Time |
09:48 |
Sent To |
I |
|
Notes |
2015-10-27 10:41:44 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE2011 EDITION | | OF THE NEC, (NATIONAL ELECTRICAL CODE); THE 5TH EDITION | | OF THE FBC, (FLORIDA BUILDING CODE) AS APPLICABLE AND | | BELOW ARE THE DEFICIENCIES NOTED. | | 1. FIXTURE SCHEDULE OR LEGEND SHALL BE REVISED TO MATCH | | THE FLOOR PLANS MARKINGS. IT SHALL CLEARLY INDICATE THE | | EMERGENCY LIGHTING AS REQUIRED. | | 2. ALL LIGHTING SHALL COMPLY WITH THE ENERGY | | CONSERVATION REQUIREMENTS FOR THE FBC. | | 3. PROVIDE A LIGHTING PLAN FOR THE 2ND FLOOR AREA. | | INCLUDE THE STAIRWAY ILLUMINATION AND SWITCHING | | REQUIREMENTS. | | 4. NEC 210.62 HAS SPECIFIC SHOW WINDOW LIGHTING | | REQUIREMENTS NOT ALL OF WHICH HAVE BEEN COMPLIED WITH. | | YOU SHALL PROVIDE A SHOW WINDOW OUTLET FOR EVERY 12 | | LINEAR FOOT OR PORTION THEREFOF. NOT JUST A SELECTED | | SET OF WINDOWS. | | 5. NEC 600.5 HAS SPECIFIC REQUIREMENTS FOR SIGN | | OUTLETS. IT CALLS FOR A DEDICATED SIGN OUTLET AT EVERY | | PEDESTRIAN ENTRY TO EVERY COMMERCIAL ESTABLISHMENT. | | THAT DOES NOT MEAN JUST THE FRONT/MAIN DOOR. | | 6. PROVIDE A POWER PLAN FOR THE 2ND FLOOR AREA. | | 7. SHOW ON THE FLOOR PLAN THE ELECTRICAL OUTLETS OR | | POWER SOURCE FOR ALL THE WORK TABLES OR STATIONS. | | 8. THE ADDITIONAL OUTLET WILL AFFECT THE ELECTRICAL | | LOAD CALCS AND MAYBE THE RISER DIAGRAM. CORRECT THOSE | | ACCORDINGLY. | | THE PLANS SHALL BE REVISED TO ADDRESS THE HEREIN | | MENTIONED ITEMS; ONCE CORRECTED SHALL BE RESUBMITTED | | FOR ANOTHER REVIEW. WHEN RESUBMITTING, YOU ARE REQUIRED | | TO PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM ALONG | | WITH THE STANDARD CITY RE-SUBMITTAL FORM. PLEASE, | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE SUBMITTAL | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARISON. CLOUDING THE CHANGES WILL BE GREATLY | | APPRECIATED. | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2016-04-13 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-04-13 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-04-13 |
Time |
12:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2016-03-02 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-03-02 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-02-29 |
Time |
16:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2016-01-15 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-01-15 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-01-15 |
Time |
11:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2015-12-02 |
|
|
Cont ID |
|
Sent By |
rlindow |
Date |
2015-12-02 |
Time |
|
Rev Time |
0.00 |
Received By |
rlindow |
Date |
2015-12-02 |
Time |
|
Sent To |
|
|
Notes |
2015-12-02 10:43:07 | PREVIOUS COMMENTS HAVE NOT BEEN ADDRESSED. | | IN ADDITON INCLUDE EXHAUST FAN DRAWINGS ON MASTER | | BUILDING SET OF PLANS. | | PLANS SHOW NO WORK IN RESIDENTIAL SPACE ON FLOOR 2, | | THIS IS CONTRADICTED BY DEMO PLANS. | | WINDOWS BY NEW STAIR LOCATION WILL REQUIRE FIRE RATING. | | 12/2/2015, LINDOW | | | | PREVIOUS COMMENTS FOR REFERENCE. | | DEFINE INTENDED USE OFCSTUDIO 102 | | PROVIDE FIRE RATING DETAIL FOR SECOND FLOOR | | RESIDENTIAL. | | PROVIDE DEMOLITION PLANS. | | SEPARATE DRAWINGS AND PERMIT REQUIRED FOR EXHAUST HOOD | | AND FIRE SUPPRESSION SYSTEM. | | 9/17/15 LINDOW |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2015-09-17 |
|
|
Cont ID |
|
Sent By |
Lindow |
Date |
2015-09-17 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2015-09-17 |
Time |
|
Sent To |
|
|
Notes |
2015-09-17 17:24:35 | DEFINE INTENDED USE OFCSTUDIO 102 | | PROVIDE FIRE RATING DETAIL FOR SECOND FLOOR | | RESIDENTIAL. | | PROVIDE DEMOLITION PLANS. | | SEPARATE DRAWINGS AND PERMIT REQUIRED FOR EXHAUST HOOD | | AND FIRE SUPPRESSION SYSTEM. | | 9/17/15 LINDOW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2016-05-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-05-24 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-04-11 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-03-09 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2016-03-09 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2016-02-19 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-02-19 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2016-02-19 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2016-01-04 |
Time |
08:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-12-30 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-30 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-11-18 |
Time |
13:42 |
Sent To |
|
|
Notes |
2015-12-30 15:18:36 | 12/30/15 FAILED THE LAST OF THE TRADE REVIEWS AS NOTED. | | NONE OF THE ELECTRICAL COMMENTS OF THE PRIOR REVIEW | | WERE ADDRESSED. CONTRACTOR NOTIFIED VIA PHONE CALL FOR | | LACK OF EMAIL ADDRESS AND SENT FILE TO LARGE DENIED BIN | | "L". MA | 2015-11-18 13:42:57 | C38 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-10-27 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-10-27 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-09-15 |
Time |
15:07 |
Sent To |
|
|
Notes |
2015-10-27 10:49:32 | 10/27/15 FAILED ELECTRICAL REVIEW AS NOTED. CUSTOMER | | NOTIFIED VIA EMAIL. SENT TO LARGE DENIED BIN "L". MA | 2015-09-15 15:08:09 | C39 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
N |
Date |
2016-05-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-05-06 |
Time |
06:25 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-05-06 |
Time |
06:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
N |
Date |
2016-02-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-02-27 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-02-27 |
Time |
08:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2015-11-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-11-25 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-11-25 |
Time |
08:35 |
Sent To |
|
|
Notes |
2015-11-25 09:45:11 | IMPACT FEES | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-09-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-09-25 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-09-25 |
Time |
11:27 |
Sent To |
|
|
Notes |
2015-09-25 11:27:56 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2016-05-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-05-24 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-04-28 |
Time |
07:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2016-02-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-02-29 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-02-29 |
Time |
09:41 |
Sent To |
|
|
Notes |
2016-02-29 10:01:38 | 4TH REVIEW: FBC 2014 MECHANICAL | | PERMIT #1509-0611 | | 2/29/16 | | | | 1) THE PREVIOUS ENERGY EFFICIENCY FORM WAS MISSING DATA | | FOR THE RTU AND AC-1. THE REVISED SUBMITTAL IS NOW | | MISSING COMPLIANCE DATA FOR AC- 2 & 3. PLEASE PROVIDE A | | COMPLETE SUBMITTAL. | | 2) M2.1: THE PLAN INDICATES A RETURN GRILL IN THE PAPER | | MAKING ROOM, HOWEVER NON-RECIRCULATED EXHAUST MAY BE | | REQUIRED IN THE ROOM PER TABLE 403.3 AND SECTIONS 510 | | AND 511 IF THE PROCESSES TAKING PLACE THERE PRODUCE | | FUMES OR DUSTS. PLEASE SUBMIT MANUFACTURER'S | | SPECIFICATIONS FOR THE PAPER MAKING EQUIPMENT. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2016-01-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-01-11 |
Time |
07:25 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-01-11 |
Time |
07:24 |
Sent To |
|
|
Notes |
2016-01-11 08:14:18 | 3RD REVIEW: FBC 2014 MECHANICAL | | PERMIT #15090611 | | 01/11/16 | | | | 1) SHEET M6.1: THE AIR BALANCE SCHEDULE DOES NOT | | INCLUDE THE MAKE-UP AIR AND EXHAUST CFM'S FOR THE | | KITCHEN HOOD. | | 2) M6.1: AN ENERGY RECOVERY VENTILATION SYSTEM IS | | REQUIRED FOR THE OARTU-1 SERVING THE STUDIO/KITCHEN | | AREA- SEE TABLE C403.2.6 FBC-14 ENERGY CONSERVATION AND | | REVISE THE PLANS TO SHOW COMPLIANCE. | | 3) M2.1: PLACE A DUCT SMOKE DETECTOR SYMBOL IN THE | | RETURN AIR SYSTEM OF RTU-1 IN ACCORDANCE WITH SECTION | | 606.2.1 FBC-14 MECHANICAL. | | 4) THE REVISED ENERGY CALCULATION FORM 506-2014 DOES | | NOT INCLUDE COMPLIANCE DATA FOR THE RTU'S OR AHU-1. | | 5) CLARIFY IF EXHAUST SYSTEMS WILL BE PROVIDED FOR ANY | | OF THE PAPER MAKING EQUIPMENT AND PROVIDE DETAILS ON | | THE PLAN. | | 6) M2.1 & M2.2: SHOW ACCESS PANEL LOCATIONS AND | | DIMENSIONS FOR AHU'S- 1 & 2: SEE SECTION 306.1. | | 7) M2.3: PLEASE LABEL ON ROOF TOP EQUIPMENT SHOWN ON | | THE PLAN. | | 8) PROVIDE A SUBMITTAL FOR THE RTU AND OARTU CURBS | | REVIEWED AND APPROVED BY THE ENGINEER OF RECORD, AND | | REVISE SHEET S7.0 TO SHOW DETAILS FOR ATTACHING THE | | UNITS TO THE CURBS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-11-23 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-11-23 |
Time |
15:48 |
Sent To |
|
|
Notes |
2015-11-23 15:52:04 | 2ND REVIEW 2014 MECHANICAL | | PERMIT #15090611 | | 11/23/15 | | | | THE MECHANICAL COMMENTS FROM THE 1ST REVIEW STILL | | EXIST. NO CORRECTED OR REVISED PLANS HAVE BEEN | | SUBMITTED. I HAVE REPRINTED MY COMMENTS FROM THE 1ST | | REVIEW BELOW. PLEASE PROVIDE A RESPONSE NARRATIVE | | ADDRESSING EACH OF THE COMMENTS, ALONG WITH CORRECTED | | PLANS AND SUBMITTALS. | | | | 1ST REVIEW FBC 2014 MECHANICAL | | PERMIT #15090611 | | 9/25/15 | | | | 1) SHEET M6.1: THE O/A CALCULATIONS AND THE AIR BALANCE | | SCHEDULE NEED TO BE CORRECTED TO BE IN COMPLIANCE WITH | | TABLE 403.3 FBC-14 MECHANICAL: A) OARTU-1 IS SUPPLYING | | AIR FOR BOTH THE STUDIO AND THE KITCHEN. BASED ON THE | | ARTISTIC RENDITION OF THIS AREA SHOWN ON THE COVER | | SHEET OF THE PLANS, THE STUDIO AREA APPEARS TO BE USED | | FOR EITHER DOING ART WORK OR VIEWING ART WORK. | | THEREFORE, USING TABLE 403.3, PROVIDE CALCULATIONS FOR | | EITHER ART STUDIO OR MUSEUMS/GALLERIES. THE KITCHEN | | AREA PER TABLE 403.3 MUST BE CALCULATED USING .7 PER | | SQ. FT. EXHAUST RATE. IF AIR IS TO BE PROVIDED FOR | | KITCHEN OCCUPANTS PLEASE SHOW THAT CALCULATION, AND | | RE-CONFIGURE THE PLANS AND AIR BALANCE SCHEDULE PER THE | | REVISED CALCULATIONS. PLEASE NOTE THAT THE1190 CFMS FOR | | 15 OCCUPANTS SHOWN IN THE SCHEDULE AMOUNTS TO | | APPROXIMATELY 80 CFM PER OCCUPANT, HOWEVER YOUR | | CALCULATIONS ARE BASED ON 5 CFM PER OCCUPANT. B) REVISE | | THE O/A CALCULATIONS IN THE SAME MANNER FOR RTU-1 | | SERVING THE GALLERY, AND AHU-1 WHICH IS ALSO SERVING A | | GALLERY AREA. | | 2) BASED ON THE REVISED O/A CALCULATIONS REFER TO TABLE | | C403.2.6 FBC-14 ENERGY CONSERVATION AND REVIEW FOR | | APPLICABILITY TO THE PROPOSED OARTU-1 INSTALLATION. | | 3) M6.1: PROVIDE AN EQUIPMENT SCHEDULE FOR DHMF-1. | | INDICATE HOW THIS UNIT WAS SIZED AND PROVIDE CONTROLS | | OPERATION DETAILS. | | 4) PROVIDE INSTALLATION DETAILS FOR DHMF-1 AND AHU-1 | | 5) DUCT SMOKE DETECTORS ARE REQUIRED TO BE INSTALLED IN | | THE RETURN AIR SYSTEMS OF OARTU-1 AND RTU-1. | | 6) ENERGY FORM 506-2014: PLEASE ADD THE COMPLIANCE DATA | | FOR THE NEW FENESTRATION, AND COMPLETE THE MANDATORY | | REQUIREMENTS CHECKLIST BEGINNING ON PAGE 7. | | 7) PLEASE PLACE A NOTE ON THE KITCHEN HOOD WILL BE DONE | | UNDER A SEPARATE PERMIT AS REQUIRED BY THE WPB | | CONSTRUCTION SERVICES DEPT. | | 8) SHEET A1.2: SHOW THE LOCATION OF CU-1. | | 9) PROVIDE CONDENSATE DISPOSAL PLANS AND DETAILS FOR | | THE NEW AC SYSTEMS- SECTION 307. | | 10) PROVIDE STRUCTURAL DETAILS FOR THE NEW RTU ROOF | | OPENINGS, AND WINDLOAD TIE DOWN ENGINEERING FOR ALL | | ROOF TOP HVAC APPLIANCES AND EQUIPMENT- SECTION 301.15 | | FBC-4 MECHANICAL. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-09-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-09-25 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-09-25 |
Time |
14:53 |
Sent To |
|
|
Notes |
2015-09-25 16:29:33 | 1ST REVIEW FBC 2014 MECHANICAL | | PERMIT #15090611 | | 9/25/15 | | | | 1) SHEET M6.1: THE O/A CALCULATIONS AND THE AIR BALANCE | | SCHEDULE NEED TO BE CORRECTED TO BE IN COMPLIANCE WITH | | TABLE 403.3 FBC-14 MECHANICAL: A) OARTU-1 IS SUPPLYING | | AIR FOR BOTH THE STUDIO AND THE KITCHEN. BASED ON THE | | ARTISTIC RENDITION OF THIS AREA SHOWN ON THE COVER | | SHEET OF THE PLANS, THE STUDIO AREA APPEARS TO BE USED | | FOR EITHER DOING ART WORK OR VIEWING ART WORK. | | THEREFORE, USING TABLE 403.3, PROVIDE CALCULATIONS FOR | | EITHER ART STUDIO OR MUSEUMS/GALLERIES. THE KITCHEN | | AREA PER TABLE 403.3 MUST BE CALCULATED USING .7 PER | | SQ. FT. EXHAUST RATE. IF AIR IS TO BE PROVIDED FOR | | KITCHEN OCCUPANTS PLEASE SHOW THAT CALCULATION, AND | | RE-CONFIGURE THE PLANS AND AIR BALANCE SCHEDULE PER THE | | REVISED CALCULATIONS. PLEASE NOTE THAT THE1190 CFMS FOR | | 15 OCCUPANTS SHOWN IN THE SCHEDULE AMOUNTS TO | | APPROXIMATELY 80 CFM PER OCCUPANT, HOWEVER YOUR | | CALCULATIONS ARE BASED ON 5 CFM PER OCCUPANT. B) REVISE | | THE O/A CALCULATIONS IN THE SAME MANNER FOR RTU-1 | | SERVING THE GALLERY, AND AHU-1 WHICH IS ALSO SERVING A | | GALLERY AREA. | | 2) BASED ON THE REVISED O/A CALCULATIONS REFER TO TABLE | | C403.2.6 FBC-14 ENERGY CONSERVATION AND REVIEW FOR | | APPLICABILITY TO THE PROPOSED OARTU-1 INSTALLATION. | | 3) M6.1: PROVIDE AN EQUIPMENT SCHEDULE FOR DHMF-1. | | INDICATE HOW THIS UNIT WAS SIZED AND PROVIDE CONTROLS | | OPERATION DETAILS. | | 4) PROVIDE INSTALLATION DETAILS FOR DHMF-1 AND AHU-1 | | 5) DUCT SMOKE DETECTORS ARE REQUIRED TO BE INSTALLED IN | | THE RETURN AIR SYSTEMS OF OARTU-1 AND RTU-1. | | 6) ENERGY FORM 506-2014: PLEASE ADD THE COMPLIANCE DATA | | FOR THE NEW FENESTRATION, AND COMPLETE THE MANDATORY | | REQUIREMENTS CHECKLIST BEGINNING ON PAGE 7. | | 7) PLEASE PLACE A NOTE ON THE KITCHEN HOOD WILL BE DONE | | UNDER A SEPARATE PERMIT AS REQUIRED BY THE WPB | | CONSTRUCTION SERVICES DEPT. | | 8) SHEET A1.2: SHOW THE LOCATION OF CU-1. | | 9) PROVIDE CONDENSATE DISPOSAL PLANS AND DETAILS FOR | | THE NEW AC SYSTEMS- SECTION 307. | | 10) PROVIDE STRUCTURAL DETAILS FOR THE NEW RTU ROOF | | OPENINGS, AND WINDLOAD TIE DOWN ENGINEERING FOR ALL | | ROOF TOP HVAC APPLIANCES AND EQUIPMENT- SECTION 301.15 | | FBC-4 MECHANICAL. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2016-02-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-02-24 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-02-24 |
Time |
09:03 |
Sent To |
|
|
Notes |
2016-02-24 09:12:34 | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING PROVISO: | | | | PLEASE PROVIDE TWO COPY'S OF A DETAILED LETTER ON THE | | USE OF THE KITCHEN ON THE FIRST FLOOR REFERENCING A | | PHONE CONVERSATION IS NOT ADEQUATE SHALL BE SIGNED AND | | SEALED BY ARCHITECT. | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2016-01-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-01-15 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-01-15 |
Time |
14:03 |
Sent To |
|
|
Notes |
2016-01-15 15:49:49 | 3RD REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. (A) THE LETTER PROVIDED FROM THE ARCHITECT | | ADDRESSING THE NEED FOR A GREASE TRAP DOES NOT GIVE | | ENOUGH DETAIL OF WHAT THE KITCHEN IS BEING USED FOR. | | (B)SHT. E3.1 SHOWS DINNING TABLE COOKING TOP AND DOUBLE | | OVEN THIS INDICATES FOOD COOKING PLEASE CLARIFY. | | (C) I AM NOT SATISFIED THERE IS NO COOKING GOING ON | | HERE PLEASE CONTACT ME. | | 2. THE ENLARGED MOP SINK IN RM 107 REQUIRES HOT AND | | COLD WATER SUPPLY NONE IS SHOWN PLEASE PROVIDE. | | PER WPB AMEND TO FBC SEC107.2.1 | | 3. THE FLOOR DRAIN IN RM 110 IS NOT SHOWN ON SANITARY | | RISER. | | PER WPB AMEND TO FBC SEC107.2.1 | | 4 PLEASE PROVIDE TRAP PRIMERS TO ALL FLOOR DRAINS. | | PER FBC PL SEC 1002.4 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-11-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-11-21 |
Time |
06:32 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-11-21 |
Time |
05:34 |
Sent To |
|
|
Notes |
2015-11-21 06:20:05 | 1) SHT. A6.0 - DETAIL #4 REFERS TO OUTDOOR SEATING.THE | | OCCUPANT LOAD SHALL BE INCLUDED IN THE TOTAL OCCUPANT | | LOAD.SHOW THE MAXIMUM HEIGHT OF THE COUNTER. | | 2) THE WASHING MACHINE SHALL BE INSTALLED ON A MINIMUM | | 3 INCH WASTE STACK PER 2014 FBC-PLUMBING SEC.406. | | 3) AS DRAWN, A DRINKING FOUNTAIN IS INSTALLED ON A | | HORIZONTAL WET VENT WHICH IS PROHIBITED PER SEC.912.1 | | OF FBCP. THE DRINKING FOUNTAIN MUST CCONNECT TO THE | | BUILDING DRAIN DOWNSTREAM OF THE WATER CLOSET IN | | T.R.#105. | | 4) THE BRANCH DRAIN FOR THE SINKS, FLOOR DRAINS AND | | WASHING MACHINE CANNOT BE ON A WET VENT PER FBCP SEC. | | 912.1.THE BRANCH DRAIN SHALL CONNECT TO THE BUILDING | | DRAIN DOWNSTREAM OF THE WATER CLOSET IN T.R.#105. | | 5) A SERVICE SINK IS REQUIRED PER 2014 FBCP TABLE | | 403.1. | | 6) A GREASE TRAP IS REQUIRED PER 2014 FBCP SEC. | | 1003.3.1. | | 7) SUBMIT A DETAIL OF THE CONDENSATE DRYWELL AND | | PIPING. WPB AMEND. TO FBC SEC. 107.2.1. | | 8) HOT WATER SHALL BE SUPPLIED TO ALL FIXTURES USED FOR | | CULINARY,CLEANINSING, LAUNDRY, OR BUILDING MAINTENANCE | | PURPOSES PER FBCP SEC.607.1. SEE SK-2 AND IT SHALL BE | | SUPPLIED TO THE SERVICE SINK. | | 9) SIZE THE WATER SUPPLY LINES TO ALL FIXTURES ON THE | | WATER RISER. ( WASHER, SK-3, EWH, TOILRT ROOMS, SK-2) | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-09-21 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-09-21 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-09-21 |
Time |
15:45 |
Sent To |
|
|
Notes |
2015-09-21 16:01:14 | | | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | 1.A GREASE TRAP IS REQUIRED PER. FBCP 1003.3.1 | | 2.A SERVICE SINK IS REQUIRED PER FBCP TABLE 403.1 | | 3. TOILET IN BATHROOM 105 IS NOT VENTED IT SHALL COMPLY | | WITH FBCP SEC 910.1 OR 912.1 | | 4.MAIN TRUNK LINE SHALL TIE IN DOWNSTREAM OF BATHROOM | | GROUP OR BRACH OFF OF MAIN TRUNK LINE PER FBCP SEC | | 912.1 | | 5.FLOOR DRAINS NOT VENTED SHALL COMPLY WITH 910.1.OR | | 914.1 | | 6. WASHING MACHINE SHALL BE ACCESSIBILITY PER FBC ACC | | SEC 611 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
P |
Date |
2016-05-25 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2016-05-25 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2016-05-25 |
Time |
13:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
F |
Date |
2016-05-06 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2016-05-06 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2016-05-06 |
Time |
12:09 |
Sent To |
|
|
Notes |
2016-05-06 17:32:15 | PLANNING AND ZONNG COMMENTS: ***FAILED*** | | | | 5/6/16 | | | | THE FOLLOWING COMMENTS FROM THE LAST REVIEW HAVE NOT | | BEEN ADDRESSED: | | | | 1. [ PREVIOUS COMMENT #2.] THE AMOUNT OF NEW SQUARE | | FOOTAGE BEING RECONSTRUCTED WILL TRIGGER AN INFORMAL | | SITE PLAN REVIEW (ISPR) THROUGH THE PLANNING DIVISION. | | PLEASE SUBMIT AN APPLICATION FOR REVIEW. | | | | 2. [PREVIOUS COMMENT #3.] FOR NEW VERTICAL CONTRUCTION | | TO OCCUR WITHIN THE EXISTING NORTH-SOUTH UTILITY | | EASEMENT DOWN THE CENTER OF THE PROPERTY, THE EASEMENT | | WILL NEED TO BE VACATED PRIOR TO WORK COMMENCING IN THE | | LOCATION OF THE EASEMENT. IF THERE IS NO NEW VERTICAL | | STRUCTURE BEING PROPOSED IN THE EASEMENT, THEN ONLY | | EASEMENT CONSENT FORMS NEED TO BE SUBMITTED FOR OTHER | | SITE WORK OCCURING WITHIN THE EASEMENT AREA. | | | | GENERAL COMMENT: | | | | 3. A SEPARATE PERMIT IS REQUIRED FOR LANDSCAPING. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2016-03-09 |
Time |
|
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2016-03-03 |
Time |
15:55 |
Sent To |
|
|
Notes |
2016-03-09 11:53:38 | PLANNING AND ZONNG COMMENTS: ***FAILED*** | | | | 3/9/16 | | | | 1. A SIGNFICANT PORTION OF THE EXISTING BUILDING HAS | | BEEN DEMOLISHED. SITE PLAN DOES NOT INDICATE WHAT IS | | THE EXISTING BUILDING AND WHAT IS THE NEW BUILDING. | | ADDITIONALLY, THE BUILDING ELEVATIONS REFLECT THE USE | | OF EXISTING WALLS WHICH NO LONGER EXISTS. PLEASE UPDATE | | THE SITE PLAN AND ELEVATIONS TO REFLECT NEW VERSUS | | EXISTING. | | | | 2. THE AMOUNT OF NEW SQUARE FOOTAGE BEING RECONSTRUCTED | | WILL TRIGGER AN INFORMAL SITE PLAN REVIEW (ISPR) | | THROUGH THE PLANNING DIVISION. PLEASE SUBMIT AN | | APPLICATION FOR REVIEW. | | | | 3. FOR NEW VERTICAL CONTRUCTION TO OCCUR WITHIN THE | | EXISTING NORTH-SOUTH UTILITY EASEMENT DOWN THE CENTER | | OF THE PROPERTY, THE EASEMENT WILL NEED TO BE VACATED | | PRIOR TO WORK COMMENCING IN THE LOCATION OF THE | | EASEMENT. IF THERE IS NO NEW VERTICAL STRUCTURE BEING | | PROPOSED IN THE EASEMENT, THEN ONLY EASEMENT CONSENT | | FORMS NEED TO BE SUBMITTED FOR OTHER SITE WORK OCCURING | | WITHIN THE EASEMENT AREA. | | | | GENERAL COMMENT: | | | | 4. A SEPARATE PERMIT IS REQUIRED FOR LANDSCAPING. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2016-01-08 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2016-01-08 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2016-01-06 |
Time |
11:52 |
Sent To |
|
|
Notes |
2016-01-08 13:08:23 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | 1/8/16 | | | | 1. THE SUBJECT PROPERTY IS LOCATED IN THE NEIGHBORHOOD | | COMMERCIAL (NC) ZONING DISTRICT. SETBACKS SHOWN ON THE | | SITE PLAN WILL NEED TO BE THOSE FOR THE NC ZONING | | DISTRICT (ZLDR SEC. 94-144(2)). PLEASE DEMONSTRATE | | COMPLIANCE. | | | | 2. REVISED BUILDING PLANS INDICATE ADDITIONAL SQUARE | | FOOTAGE IS BEING ADDED TO THE BUILDING. PLEASE PROVIDE | | DATA REGARDING THE CHANGE IN BUILDING SQUARE FOOTAGE | | AND INDICATE COMPLIANCE WITH THE MAXIMUM ALLOWABLE FAR | | FOR THE NC ZONING DISTRICT (0.75) - [ZLDR SEC. | | 94-144(8)(C)]. PLEASE NOTE THE ADDITION OF 1,001 SQUARE | | FEET OR GREATER WILL REQUIRE A INFORMAL -LEVEL I SITE | | PLAN SUBMITTAL FOR REVIEW AND APPROVAL THROUGH THE | | PLANNING DIVISION PRIOR TO APPROVAL OF THE BUILDING | | PERMIT. | | | | 3. THE ADDITION OF SQUARE FOOTAGE REQUIRES THE ADDITION | | OF PARKING SPACES PROPORTIONAL TO THE USE AND SIZE OF | | THE ADDITIONAL SQUARE FOOTAGE. PLEASE CLEARLY INDICATE | | ON THE PLANS THE EXISTING PARKING WHICH SERVICES THE | | BUILDING AND ADDITIONAL REQUIRED PARKING FOR THE NEW | | SQUARE FOOTAGE. | | | | 4. THE PLANS PROPOSE AN EXPANSION OF THE BUILDING | | PARAPET. IT APPEARS THE MAXIMUM BUILDING HEIGHT WILL BE | | 29 FEET. THE NC ZONING DISTRICT HAS A MAXIMUM BUILDING | | HEIGHT OF 30 FEET [ZLDR SEC. 94-144(6)]. PLEASE | | DEMONSTRATE COMPLIANCE. | | | | 5. MECHANICAL EQUIPMENT ON THE EAST SIDE OF THE | | ONE-STORY PORTION OF THE BUILDING IS NOT SCREENED. | | PLEASE PROVIDE SCREENING. | | | | 6. PLEASE PROVIDE BICYCLE PARKING DETAIL FOR THE RACK | | AND SPACING. PLEASE CONTACT ME FOR MINIMUM | | SPACING/DIMENSIONAL REQUIREMENTS IF NEEDED. | | | | 7. ADA STRIPING IS NOT CORRECT WITH DOUBLE STRIPING | | SPACING. PLEASE CONTACT ME FOR STRIPING DIAGRAM/DETAIL | | IF NEEDED. | | | | 8. RESPONSE COMMENTS INDICATE THAT THE DUMPSTER FOR THE | | PROPERTY WILL BE LOCATED ON THE EAST SIDE OF THE | | BUILDING. IF DUMPSTER WILL BE LOCATED OUTSIDE, A | | DUMPSTER ENCLOSURE WILL BE REQUIRED IN ACCORDANCE WITH | | ZLDR SEC. 94-444 AND THE LOCATION WILL NEED TO BE SHOWN | | ON A SITE PLAN FOR REVIEW. | | | | 9. SEPARATE LANDSCAPE PERMIT IS REQUIRED. LANDSCAPE | | PLANS WILL NEED TO BE SIGNED AND SEALED BY A LANDSCAPE | | ARCHITECT AND TREE ALTERATION PERMIT THROUGH THE | | PLANNING DIVISION IS REQUIRED FOR REMOVAL OR RELOCATION | | OF ANY TREES. THE LANDSCAPE PLAN WILL ALSO NEED TO BE | | REVIEWED FOR COMPLIANCE WITH VISIBILITY TRIANGLE | | REQUIREMENTS [ZLDR SEC. 94-305]. | | | | 10. EASEMENT CONSENT FORM IS REQUIRED FOR WORK IN THE 5 | | FOOT UTILITY EASEMENT RUNNING ALONG THE NORTH SIDE OF | | THE PROPERTY. THE CENTRALLY LOCATED UTILITY EASEMENT | | RUNNING NORTH-SOUTH ON THE PROPERTY WILL REQUIRE | | APPROVAL OF THE UTILITY EASEMENT VACATION PRIOR TO WORK | | COMMENCING IN THE LOCATION OF THE EASEMENT. | | | | GENERAL COMMENTS: | | | | A. WHEN SEPARATE PERMIT IS SUBMITTED FOR PROPOSED | | BUILDING AWNING, PLEASE PROVIDE SITE PLAN INDICATING | | COMPLIANCE WITH SETBACKS [ZLDR SEC. 94-144 AND 94-305]. | | PLEASE NOTE THAT ANY ENCROACHMENT INTO FDOT | | RIGHT-OF-WAY (S. DIXIE HWY.) WILL REQUIRE ADDITIONAL | | APPROVAL FROM FDOT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2015-12-03 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2015-12-03 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2015-12-03 |
Time |
11:09 |
Sent To |
E |
|
Notes |
2015-12-03 15:59:03 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | 12/3/15 | | | | 1. REPONSE LETTER AND REVISED PLANS DID NOT ADDRESS | | ZONING'S PREVIOUS COMMENTS. PREVIOUS COMMENTS HAVE BEEN | | RE-LISTED BELOW. | | | | 2. IN ADDITION TO THE PREVIOUS COMMENTS, REVISED SHEETS | | SHOW A CHANGE IN THE BUILDING FOOTPRINT ALONG S. DIXIE | | HWY. THIS CHANGE NEEDS TO BE REFECTED ON THE SITE PLAN | | AS WELL AS CONSISTENTLY DEPICTED ON ALL BUILDING | | SHEETS. | | | | [PREVIOUS COMMENT #1] PROVIDE TWO COPIES OF PROPERTY | | SURVEY WITH RESUBMITTAL. | | | | [PREVIOUS COMMENT #2] PROPOSED LANDSCAPE ISLANDS ALONG | | THE SOUTH SIDE OF THE BUILDING EXTEND INTO THE | | RIGHT-OF-WAY. ANY WORK IN THE RIGHT-OF-WAY WILL REQUIRE | | A SEPARATE RIGHT-OF-WAY PERMIT BE SECURED. IT IS | | RECOMMENDED THE LANDSCAPE ISLANDS BE REDESIGNED AND | | LOCATED COMPLETELY WITHIN THE PROPERTY LINE AND | | ADDITIONAL STRIPING PROVIDED WHERE THE LANDSCAPE ISLAND | | WOULD HAVE EXTENDED TO FOR TRAFFIC MANAGEMENT PURPOSES. | | | | [PREVIOUS COMMENT #3] THE VALUE OF THE CONSTRUCTION | | ($300,000) EXCEEDS 50% OF THE STRUCTURE'S VALUE | | ($425,631) ACCORDING TO THE P.B.C. PROPERTY APPRAISER'S | | OFFICE; THEREFORE, PURSUANT TO SECTION 94-441(C)(2) OF | | THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), THE | | LANDSCAPE ON THE SITE SHALL BE IN COMPLIANCE WITH ALL | | APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF THE | | ZLDR. IF THE SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) | | COPIES OF A LANDSCAPE PLAN DEMONSTRATING COMPLIANCE | | SHALL BE INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE | | SITE DOES NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE | | ZONING APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE | | PERMIT AND IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING | | MATERIAL TO BRING THE SITE INTO CONFORMITY. | | | | [PREVIOUS COMMENT #4] SEPARATE PERMIT REQUIRED FOR | | LANDSCAPING. | | | | [PREVIOUS COMMENT #5] SEPARATE PERMIT REQUIRED FOR | | PARKING AREA STRIPING. | | | | [PREVIOUS COMMENT #6] CORRECT STRIPING DETAIL TO SHOW | | DOUBLE STRIPED LINE ON BOTH SIDES OF THE HANDICAP | | PARKING SPACE. ALL STRIPING TO BE WHITE EXCEPT FOR | | INSIDE DOUBLE STRIPED LINE FOR THE HANDICAP SPACE SHALL | | BE BLUE. PLEASE CONTACT ME FOR A COPY OF THE DETAIL IF | | NEEDED. | | | | [PREVIOUS COMMENT #7] INDICATE LOCATION OF MINIMUM 10 | | FEET BY 25 FEET LOADING ZONE LOCATION [ZLDR SEC. | | 94-485(P)]. PROPOSED OVERHEAD DOOR ON REAR OF BUILDING | | INDICATES A LOADING AREA WILL BE IN THE REAR. TO | | FACILITATE THE INGRESS/EGRESS AT THE REAR OF THE | | PROPERTY, THE DRIVE AISLE TO THE REAR OF THE BUILDING | | SHOULD BE WIDENED TO A MINIMUM OF 24 FEET. | | | | [PREVIOUS COMMENT #8] FOR PROPOSED WORK WITHIN UTILITY | | EASEMENT AREAS, PLEASE PROVIDE COMPLETE UTILITY | | EASEMENT CONSENT FORMS FROM UTILITY PROVIDERS: | | HTTP://WPB.ORG/DEVELOPMENT/WP-C | | ONTENT/UPLOADS/SITES/33/2013/09/EASEMENT-CONSENT-FORM. | | PDF | | | | [PREVIOUS COMMENT #9] INDICATE SETBACKS OF NEW PAVERS | | ALONG THE NORTH SIDE OF THE BUILDING. PAVERS MUST BE A | | MINIMUM OF 2 FEET FROM THE PROPERTY LINE [ZLDR SEC. | | 94-305(B)(7)]. | | | | [PREVIOUS COMMENT #10] HOW IS TRASH COLLECTION BEING | | HANDLED FOR THE SITE? | | | | [PREVIOUS COMMENT #11] PROVIDE ONE BICYCLE PARKING | | SPACE [ZLDR SEC. 94-485(Q)]. | | | | [PREVIOUS COMMENT #12] PLAN INDICATES INSTALLATION OF | | NEW ROOFTOP EQUIPMENT. PLEASE INDICATE HOW THE NEW | | MECHANICAL EQUIPMENT WILL BE SCREENED FROM VIEW. | | | | | | RECOMMENDATION(S): | | | | [PREVIOUS COMMENT #A] STAFF HAS CONCERN REGARDING THE | | LOSS OF WINDOWS AND OPENING ALONG THE S. DIXIE HWY. | | FACADE. CONSIDER ANY CHANGES THAT MAY ENHANCE THE | | APPEARANCE OF MAINTAINING A STOREFRONT CHARACTER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-10-01 |
|
|
Cont ID |
|
Sent By |
dkittrid |
Date |
2015-10-01 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2015-09-28 |
Time |
10:36 |
Sent To |
|
|
Notes |
2015-10-01 11:56:34 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | 10/01/15 | | | | 1. PROVIDE TWO COPIES OF PROPERTY SURVEY WITH | | RESUBMITTAL. | | | | 2. PROPOSED LANDSCAPE ISLANDS ALONG THE SOUTH SIDE OF | | THE BUILDING EXTEND INTO THE RIGHT-OF-WAY. ANY WORK IN | | THE RIGHT-OF-WAY WILL REQUIRE A SEPARATE RIGHT-OF-WAY | | PERMIT BE SECURED. IT IS RECOMMENDED THE LANDSCAPE | | ISLANDS BE REDESIGNED AND LOCATED COMPLETELY WITHIN THE | | PROPERTY LINE AND ADDITIONAL STRIPING PROVIDED WHERE | | THE LANDSCAPE ISLAND WOULD HAVE EXTENDED TO FOR TRAFFIC | | MANAGEMENT PURPOSES. | | | | 3. THE VALUE OF THE CONSTRUCTION ($300,000) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($425,631) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | 4. SEPARATE PERMIT REQUIRED FOR LANDSCAPING. | | | | 5. SEPARATE PERMIT REQUIRED FOR PARKING AREA STRIPING. | | | | 6. CORRECT STRIPING DETAIL TO SHOW DOUBLE STRIPED LINE | | ON BOTH SIDES OF THE HANDICAP PARKING SPACE. ALL | | STRIPING TO BE WHITE EXCEPT FOR INSIDE DOUBLE STRIPED | | LINE FOR THE HANDICAP SPACE SHALL BE BLUE. PLEASE | | CONTACT ME FOR A COPY OF THE DETAIL IF NEEDED. | | | | 7. INDICATE LOCATION OF MINIMUM 10 FEET BY 25 FEET | | LOADING ZONE LOCATION [ZLDR SEC. 94-485(P)]. PROPOSED | | OVERHEAD DOOR ON REAR OF BUILDING INDICATES A LOADING | | AREA WILL BE IN THE REAR. TO FACILITATE THE | | INGRESS/EGRESS AT THE REAR OF THE PROPERTY, THE DRIVE | | AISLE TO THE REAR OF THE BUILDING SHOULD BE WIDENED TO | | A MINIMUM OF 24 FEET. | | | | 8. FOR PROPOSED WORK WITHIN UTILITY EASEMENT AREAS, | | PLEASE PROVIDE COMPLETE UTILITY EASEMENT CONSENT FORMS | | FROM UTILITY PROVIDERS: HTTP://WPB.ORG/DEVELOPMENT/WP-C | | ONTENT/UPLOADS/SITES/33/2013/09/EASEMENT-CONSENT-FORM. | | PDF | | | | 9. INDICATE SETBACKS OF NEW PAVERS ALONG THE NORTH SIDE | | OF THE BUILDING. PAVERS MUST BE A MINIMUM OF 2 FEET | | FROM THE PROPERTY LINE [ZLDR SEC. 94-305(B)(7)]. | | | | 10. HOW IS TRASH COLLECTION BEING HANDLED FOR THE SITE? | | | | 11. PROVIDE ONE BICYCLE PARKING SPACE [ZLDR SEC. | | 94-485(Q)]. | | | | 12. PLAN INDICATES INSTALLATION OF NEW ROOFTOP | | EQUIPMENT. PLEASE INDICATE HOW THE NEW MECHANICAL | | EQUIPMENT WILL BE SCREENED FROM VIEW. | | | | | | RECOMMENDATION(S): | | | | A. STAFF HAS CONCERN REGARDING THE LOSS OF WINDOWS AND | | OPENING ALONG THE S. DIXIE HWY. FACADE. CONSIDER ANY | | CHANGES THAT MAY ENHANCE THE APPEARANCE OF MAINTAINING | | A STOREFRONT CHARACTER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | | | | 2015-09-18 11:34:00 | 9/18/15 |
|
|