Plan Review Details - Permit 15090327
Plan Review Stops For Permit 15090327
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2016-07-21 Cont ID  
Sent By skennedy Date 2016-07-21 Time 11:53 Rev Time 0.00
Received By skennedy Date 2016-07-21 Time 11:26 Sent To B
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2016-07-08 Cont ID  
Sent By jgomez Date 2016-07-08 Time 14:46 Rev Time 0.00
Received By jgomez Date 2016-07-08 Time 14:46 Sent To M
Notes
2016-07-08 14:55:57RESIDENTIAL (R3) ALTERATION FOURTH BUILDING REVIEW
 CHECKLIST.
 CODE: 2014 FBC 5TH EDITION (2014).
  
 ORIGINAL COMMENT:
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
 NOTE: PLANS AND ENERGY CALCULATIONS TO BE COORDINATED
 TO AVOID CONFLICTS OR DELAYS.
 RESPONSE: TALKED TO MECHANICAL ENGINEER (RYAN TODARO)
 WHO PREPARED THE ENERGY CALCULATIONS SUBMITTED. ENERGY
 CALCULATIONS SUBMITTED IS FOR A COMMERCIAL PROJECT.
 NEED TO USE RESIDENTIAL FORM R402 FOR PRESCRIPTIVE
 METHOD OR R405 FOR PERFORMANCE METHOD.
 PERMIT CAN NOT BE ISSUED WITHOUT THE ENERGY
 CALCULATIONS. SEE SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2016-07-06 Cont ID  
Sent By jgomez Date 2016-07-06 Time 08:32 Rev Time 0.00
Received By jgomez Date 2016-07-06 Time 08:22 Sent To  
Notes
2016-07-06 08:34:07RESIDENTIAL (R3) ALTERATION THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: 2014 FBC 5TH EDITION (2014).
  
 ORIGINAL COMMENT:
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
 NOTE: PLANS AND ENERGY CALCULATIONS TO BE COORDINATED
 TO AVOID CONFLICTS OR DELAYS.
 RESPONSE: REPEAT COMMENT. THIRD TIME. NOT ADDRESSED.
 PERMIT CAN NOT BE ISSUED WITHOUT THE ENERGY
 CALCULATIONS. SEE SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 ORIGINAL COMMENT:
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) PRECAST LINTELS AS SPECIFIED ON PLANS.
 RESPONSE: NOA 06-0222.01 SUBMITTED EXPIRED FIVE YEARS
 AGO. 05/21/2011. NEED TO PROVIDE CURRENT NOA. AND,
 PROVIDE COMPLETE NOA NOT JUST THE COVER PAGE.
 NOTE: ARCHITECT REVIEWING THE PRODUCT APPROVAL TO
 PLEASE STAMP THE FRONT PAGE OF THE PRODUCT APPROVAL NOT
 THE BACK OF IT.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-06-06 Cont ID  
Sent By jgomez Date 2016-06-03 Time 18:53 Rev Time 0.00
Received By jgomez Date 2016-06-03 Time 18:39 Sent To  
Notes
2016-06-03 18:54:21RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: 2014 FBC 5TH EDITION (2014).
  
 ORIGINAL COMMENT:
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 ORIGINAL COMMENT:
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
 NOTE: PLANS AND ENERGY CALCULATIONS TO BE COORDINATED
 TO AVOID CONFLICTS OR DELAYS.
 RESPONSE: NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 3-SIZES OF WINDOWS SHOWN ON THE FLOOR PLAN ON SHEET A.2
 DON'T MATCH SIZES SHOWN ON THE EXTERIOR ELEVATIONS.
 WINDOWS SHOWN ON THE EXTERIOR ELEVATIONS DON'T COMPLY
 WITH EGRESS. PROVIDE CLEAR INFORMATION FOR THE EGRESS
 WINDOW OF THE NEW BEDROOM SHOWING COMPLIANCE WITH ALL
 THE REQUIREMENTS OF SEC. R310 OF FBC-RESIDENTIAL, 5TH
 EDITION (2014).
 RESPONSE: 4044 SH EGRESS WINDOW AS SPECIFIED ON SHEET
 A.2 AND SHOWN ON SHEET A.3 DOESN'T COMPLY WITH EGRESS.
 ALSO, IT DOESN'T MATCH PRODUCT APPROVAL SUBMITTED.
 FLORIDA PRODUCT APPROVAL FL16736-R1 SUBMITTED IS FOR
 HORIZONTAL SLIDER WINDOW. REVISE ALL PLANS COORDINATING
 TYPE AND SIZE OF WINDOW WITH PRODUCT APPROVAL
 SUBMITTED.
  
 ORIGINAL COMMENT:
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) PRECAST LINTELS AS SPECIFIED ON PLANS.
 RESPONSE: NOT ADDRESSED.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE
 OLD/VOID DRAWINGS TO RESUBMITTED SET OF DRAWINGS.
 SUBMIT OLD/VOID DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-10-27 Cont ID  
Sent By jgomez Date 2015-10-27 Time 17:28 Rev Time 0.00
Received By jgomez Date 2015-10-27 Time 17:15 Sent To E
Notes
2015-10-27 17:31:58RESIDENTIAL (R3) ALTERATION/CONVERSION BUILDING REVIEW
 COMMENTS.
 CODE: 2014 FBC 5TH EDITION (2014).
  
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
 NOTE: PLANS AND ENERGY CALCULATIONS TO BE COORDINATED
 TO AVOID CONFLICTS OR DELAYS.
  
 3- SIZES OF WINDOWS SHOWN ON THE FLOOR PLAN ON SHEET
 A.2 DON'T MATCH SIZES SHOWN ON THE EXTERIOR ELEVATIONS.
 WINDOWS SHOWN ON THE EXTERIOR ELEVATIONS DON'T COMPLY
 WITH EGRESS. PROVIDE CLEAR INFORMATION FOR THE EGRESS
 WINDOW OF THE NEW BEDROOM SHOWING COMPLIANCE WITH ALL
 THE REQUIREMENTS OF SEC. R310 OF FBC-RESIDENTIAL, 5TH
 EDITION (2014).
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) STORM SHUTTERS. AND, PROVIDE COMPLETE INSTALLATION.
 SEE CITY SAMPLE FOR SHUTTERS INSTALLATION SCHEDULE.
 NOTE: SHUTTERS REQUIRED BECAUSE WINDOWS PRODUCT
 APPROVAL SUBMITTED IS FOR NON-IMPACT WINDOWS.
  
 B) WINDOW MULLIONS. AND, CLEARLY MARK SIZE TO BE
 INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES OF SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION
 (2014).
 NOTE: PROVIDE 2 COPIES. ONLY ONE COPY WAS SUBMITTED
 THIS TIME. AND PROVIDE COMPLETE DRAWINGS. NOA
 11-1213.07 SUBMITTED IS MISSING SHEETS 4 OF 6 TO 6 OF
 6.
  
 C) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 5- DESIGNER OF RECORD TO APPROVE IN WRITING (NOT
 SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE
 OLD/VOID DRAWINGS TO RESUBMITTED SET OF DRAWINGS.
 SUBMIT OLD/VOID DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-10-29 Cont ID  
Sent By ppetty Date 2015-10-29 Time 13:03 Rev Time 0.00
Received By ppetty Date 2015-10-29 Time 12:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-07-21 Cont ID  
Sent By skennedy Date 2016-07-21 Time 11:53 Rev Time 0.00
Received By skennedy Date 2016-07-12 Time 09:19 Sent To  
Notes
2016-07-13 16:34:14RESUB TO J. GOMEZ 7/14/2016
2016-07-13 09:19:22RESUB ROUTED TO JVALIDO

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-07-11 Cont ID  
Sent By cpuell Date 2016-07-11 Time 10:03 Rev Time 0.00
Received By cpuell Date 2016-06-22 Time 11:00 Sent To  
Notes
2016-06-22 11:00:59RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-06-06 Cont ID  
Sent By jgomez Date 2016-06-06 Time 10:38 Rev Time 0.00
Received By jgomez Date 2016-05-19 Time 10:45 Sent To  
Notes
2016-05-20 10:45:42RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-10-29 Cont ID  
Sent By ppetty Date 2015-10-29 Time 13:03 Rev Time 0.00
Received By ppetty Date 2015-09-09 Time 08:59 Sent To  
Notes
2015-09-17 08:15:28R22

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 5 Status P Date 2016-07-26 Cont ID  
Sent By jgomez Date 2016-07-26 Time 18:51 Rev Time 0.00
Received By jgomez Date 2016-07-26 Time 15:48 Sent To  
Notes
2016-07-26 18:52:32NO FEES. MU-2016-18499.
2016-07-26 15:49:06JGOMEZ DESK

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status F Date 2016-07-21 Cont ID  
Sent By skennedy Date 2016-07-21 Time 12:00 Rev Time 0.00
Received By skennedy Date 2016-07-21 Time 12:00 Sent To  
Notes
2016-07-21 12:00:47SEE PRIOR REVIEW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2016-07-06 Cont ID  
Sent By jgomez Date 2016-07-06 Time 09:35 Rev Time 0.00
Received By jgomez Date 2016-07-06 Time 09:35 Sent To  
Notes
2016-07-06 09:36:071- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2016-06-06 Cont ID  
Sent By jgomez Date 2016-06-06 Time 10:38 Rev Time 0.00
Received By jgomez Date 2016-06-06 Time 10:38 Sent To  
Notes
2016-06-06 10:38:261- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-10-27 Cont ID  
Sent By jgomez Date 2015-10-27 Time 17:21 Rev Time 0.00
Received By jgomez Date 2015-10-27 Time 17:21 Sent To  
Notes
2015-10-27 17:27:551- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2016-07-14 Cont ID  
Sent By jvalido Date 2016-07-14 Time 14:31 Rev Time 0.00
Received By jvalido Date 2016-07-14 Time 14:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2016-07-13 Cont ID  
Sent By jvalido Date 2016-07-13 Time 16:29 Rev Time 0.00
Received By jvalido Date 2016-07-13 Time 16:27 Sent To  
Notes
2016-07-13 16:28:48FLORIDA ENERGY CODE FBC 2014
  
 CORRECT BTU AMOUNTS ON FORM R405-2014.
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-07-11 Cont ID  
Sent By jvalido Date 2016-07-11 Time 09:20 Rev Time 0.00
Received By jvalido Date 2016-07-11 Time 08:42 Sent To  
Notes
2016-07-11 09:20:09WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED REPLACED SHEETS DETACHED.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (1) PROVIDE ENERGY CALCULATIONS FORM R402-2014 OR FORM
 R405-2014. CONFIRM BOTH "PREPARED BY" AND "OWNER/AGENT"
 SIGNATURES ARE PRESENT.
 (2) PROVIDE MANUAL J HEAT LOAD CALCULATIONS.
  
 CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (3) PROVIDE A COMPLETE SET OF PLANS. SHOW ALL DUCTWORK
 IN THE RESIDENCE. DIFFERENTIATE NEW AND EXISTING
 DUCTWORK. SHOW ALL CFM FOR ALL AREAS OF HOME. SHOW ALL
 RETURNS FROM BEDROOMS.
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2015-10-27 Cont ID  
Sent By jgomez Date 2015-10-27 Time 19:04 Rev Time 0.00
Received By jgomez Date 2015-10-27 Time 19:04 Sent To  
Notes
2015-10-27 19:05:13NO INFORMATION SUBMITTED. PROVIDE COMPLETE INFORMATION
 UNDER A SEPARATE PERMIT.

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-09-30 Cont ID  
Sent By tklarge Date 2015-09-30 Time 05:43 Rev Time 0.00
Received By tklarge Date 2015-09-30 Time 05:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-05-23 Cont ID  
Sent By njwira Date 2016-05-23 Time 16:15 Rev Time 0.00
Received By njwira Date 2016-05-23 Time 16:15 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-09-25 Cont ID  
Sent By sgraham Date 2015-09-25 Time 11:26 Rev Time 0.00
Received By sgraham Date 2015-09-25 Time 11:26 Sent To  
Notes
2015-09-25 11:26:589/25/15 ZONING FAILED
  
 1. SUBMIT TWO COPIES OF AN UP TO DATE SURVEY.
2015-09-18 11:51:189/18/15