Plan Review Stops For Permit 15090130 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2016-06-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-06-03 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-06-02 |
Time |
07:17 |
Sent To |
|
|
Notes |
2016-06-03 10:27:07 | APPROVED WITH EXCEPTIONS | | | | 1) SUBMIT TWO SETS OF PRODUCT APPROVALS THAT HAVE BEEN | | APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE | | CLAY ROOF TILE AND THE ROOF TILE ADHESIVE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2016-04-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-04-20 |
Time |
18:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-04-19 |
Time |
17:52 |
Sent To |
|
|
Notes |
2016-04-20 18:13:14 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) (REPEAT COMMENT) FBC 107.3.4 - PROVIDE TWO SETS OF | | PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE | | REGULATED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE | | TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS | | INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN | | PRESSURES FOR EACH OF THE DIFFERENT ROOFING MATERIALS, | | RIDGE VENT, WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND | | EXTERIOR DOOR TYPES. THE PRODUCT APPROVALS WERE NOT | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD. | | | | 2) THE PRODUCT APPROVALS FOR THE RIDGE SHINGLE EXPIRED | | IN 2006. SUBMIT TWO COPIES OF A CURRENT ONE. FBC | | 107.3.4 | | | | 3) THE PLANS SPECIFY DOUBLE HUNG WINDOWS AND THE | | PRODUCT APPROVALS ARE FOR SINGLE HUNG. FBC 107.2.1 | | | | 4) THE DRAWINGS FOR THE FIXED WINDOWS ARE MISSING | | INFORMATION. THEY WERE NOT SHRUNK DOWN TO FIT ON THE | | SMALLER SIZE COPY PAPER. FBC 107.2.1 | | | | 5) SUBMIT PRODUCT APPROVALS FOR THE ROOF TILE ADHESIVE | | THAT WILL USED TO INSTALL THE MISSION CLAY TILE. FBC | | 107.3.4 | | | | 6) SUBMIT TWO SETS OF SIGNED AND SEALED RAS 117 | | CALCULATIONS FOR ENHANCED FASTENING OF THE INSULATION | | BOARDS AND BASE/ANCHOR SHEET AS REQUIRED BY GENERAL | | LIMITATION #7 OF THE JOHNS MANVILLE MODIFIED BITUMEN | | ROOFING SYSTEM (NOA NO. 13-0529.14). | | | | 7) THE PRODUCT APPROVALS FOR THE GLAZED FRENCH DOORS | | THAT WERE SUBMITTED DO NOT CORRESPOND WITH THE DOOR | | TYPES SHOWN ON SHEET A7.1 OF THE PLANS. FBC 107.2.1 | | | | 8) SUBMIT PRODUCT APPROVALS FOR THE SIDE HINGED OUT | | SWING GARAGE DOORS. FBC 107.3.4 | | | | 9) THE STRUCTURAL REPORT FROM THE ENGINEER IS REQUIRED | | TO HAVE HIS ORIGINAL HANDWRITTEN SIGNATURE ON IT. | | DIGITALLY SIGNED PLANS ARE ONLY FOR ELECTRONICALLY | | SUBMITTED DOCUMENTS. FAC 61G15-23.002 & 61G15-23.003 | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-12-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-30 |
Time |
19:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-28 |
Time |
07:56 |
Sent To |
|
|
Notes |
2015-12-30 13:48:51 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE PLANS HAVE SEVERAL REFERENCES TO THE 2010 FBC. | | THE FBC FIFTH EDITION (2014) WENT INTO EFFECT ON JUNE | | 30, 2015. ALL NEW PERMITS APPLIED FOR ON OR AFTER THAT | | DATE ARE REQUIRED TO COMPLY WITH AND REFERENCE THE FBC | | FIFTH EDITION. | | | | 2) THE PLANS REFERENCE THE 2008 NEC AND THE 2011 NEC IS | | THE EDITION THAT APPLIES TO THIS PROJECT. | | | | 3) THE OCCUPANCY TYPE FOR ONE AND TWO FAMILY DWELLINGS | | IS R-3 PER FBC SECTION 310. | | | | 4) SUBMIT TWO COPIES OF A SURVEY. FBC 107.2.1 | | | | 5) SHOW COMPLIANCE WITH FBC-R807.1 FOR ATTIC ACCESS. | | | | 6) DOUBLE UNDERLAYMENT IS REQUIRED FOR ASPHALT SHINGLE | | ROOFS WITH SLOPES LESS THAN 4/12 PER FBC-R905.2.3 | | | | 7) THE ROOF ZONE PRESSURE DIAGRAM ON S-3 AND STRUCTURAL | | NOTES ON S-2 HAVE -65 PSF FOR ROOF ZONES 2 AND 3. THE | | CORNER (ZONE 3) UPLIFT PRESSURES SHOULD BE MORE. ONE | | END OF THE ROOF IS A NOT A HIP. | | | | 8) THE STRUCTURAL NOTES ON S-2 HAVE THE COMPONENT AND | | CLADDING PRESSURES FOR WALL ZONE 5 AS -50 PSF. THIS IS | | A LITTLE LOW, IT SHOULD BE -54.1 PSF. FBC-R | | | | 9) FBC-R617.2.1 REQUIRES BUCKS TO EXTEND BEYOND THE | | INTERIOR FACE OF THE WINDOW OR DOOR FRAME. THE DRYWALL | | CAN NOT SUPPORT THE FRAME AS SHOWN IN THE DETAILS ON | | S-3. | | | | 10) NOT ALL PRODUCT APPROVALS FOR SECTIONAL GARAGE | | DOORS SPECIFY THE BUCKS TO WALL ATTACHMENT. SPECIFY THE | | REQUIRED BUCK ATTACHMENT TO BE USED WHEN ONE IS NOT | | PROVIDED IN THE PRODUCT APPROVAL. FBC 107.2.1 | | | | 11) SHOW COMPLIANCE WITH FBC-R311.7.8 FOR THE HANDRAILS | | AT THE STAIRS. | | | | 12) SHOW COMPLIANCE WITH FBC-R312.1 FOR THE GUARDS AT | | THE STAIRS. | | | | 13) PROVIDE COMPLETE STRUCTURAL DETAILS FOR THE STAIRS. | | SPECIFY ALL CONNECTIONS, ANCHORS AND CONNECTORS. FBC | | 107.2.1 | | | | 14) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF | | THE DIFFERENT ROOFING MATERIALS, RIDGE VENT, | | WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND EXTERIOR | | DOOR TYPES. | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-09-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-17 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
tmoore |
Date |
2015-09-17 |
Time |
16:24 |
Sent To |
|
|
Notes |
2015-09-17 16:27:15 | MADE SITE VISIT TO 322 MANGO PROMENADE. | | GARAGE PROPOSED TO BE DEMOLISHED IS ATTACHED TO MAIN | | HOUSE. ELECTRIC LIGHTS HANG ON THE EXTERIOR. THIS WILL | | NOT BE A TYPICAL DEMO, BUT WILL REQUIRE STRUCTURAL | | PLANS SHOWING HOW THE END WALL OF THE HOUSE WILL BE | | SECURED AND REBUILT WHEN THE GARAGE IS DEMOLISHED.. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-09-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-11 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
tmoore |
Date |
2015-09-11 |
Time |
16:17 |
Sent To |
ENG |
|
Notes |
2015-09-11 16:25:09 | BEFORE DEMO PERMIT CAN BE ISSUED, | | HISTORIC AND ENGINEERING WILL NEED TO PASS THEIR | | REVIEWS. | | AS LISTED ON PLAN, UTILITIES WILL NEED TO BE CAPPED AND | | UTILITY RELEASES WILL NEED TO BE SUBMITTED, SUCH AS | | ELECTRIC, GAS, AND WATER. | | SEWER LATERAL MUST BE CAPPED WITH A "TURN A ROUND" | | PERMIT AND FINAL #703 MUST BE PASSED. | | MOVING ON TO ENGINEERING'S MAIL BOX. | | TM |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-04-01 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-04-01 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-04-01 |
Time |
08:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-12-30 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2015-12-30 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2015-12-30 |
Time |
09:11 |
Sent To |
|
|
Notes |
2015-12-30 10:09:32 | 12/30/2015 PHIL PETTY | | PLEASE SHOW ALL MAINS,LOCATIONS OF PANEL A,METER. | | NEED LOAD CALC PANEL A,AND TOTAL LOAD. | | R-315.1 CO DETECTORS AND S/D PER 314.3.1 | | 210.52-C-3, 561-644-7305 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
N |
Date |
2016-04-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-04-21 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-04-21 |
Time |
10:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2015-09-16 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-09-16 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-09-16 |
Time |
08:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
P |
Date |
2016-06-03 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2016-06-03 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2016-06-03 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
F |
Date |
2016-04-19 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2016-04-19 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2016-04-19 |
Time |
11:03 |
Sent To |
|
|
Notes |
2016-04-19 11:13:05 | 4-19-2016 - HPB APPROVED DEMO OF GARAGE/NEW ADDITION ON | | JULY 28, 2015 (CASE HPB 15-33) | 2016-04-19 11:11:31 | 4-19-2016 - ALTHOUGH ARCHITECTURAL PLANS DENOTE | | ALUMINUM REPLACEMENT WINDOWS AND DOORS, PRODUCT | | APPROVALS ARE FOR THE INSTALLATION OF VINYL REPLACEMENT | | WINDOWS/DOORS, WHICH PER THE DIRECTION OF OUR HISTORIC | | PRESERVATION BOARD ARE NOT ALLOWED WITHIN THE HISTORIC | | DISTRICT. THIS PROPERTY IS CONSIDERED A CONTRIBUTING | | STRUCTURE TO THE HISTORIC DISTRICT, AND A REVISION OF | | PLANS TO INSTEAD USE ALUMINUM FRAME PRODUCTS WOULD BE | | ACCEPTABLE. - DLE |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2015-12-22 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-12-22 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-12-21 |
Time |
11:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2015-09-09 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-09-09 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-09-09 |
Time |
14:46 |
Sent To |
|
|
Notes |
2015-09-09 14:47:09 | SHALL SUBMIT AND RECEIVE APPROVALS FOR NEW ADDITION | | PRIOR TO ISSUANCE OF DEMO PERMIT FOR GARAGE. FRIEDERIKE | | MITTNER SPOKE TO NAT HEALY 9/9/15 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
P |
Date |
2016-08-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-08-23 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-08-23 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-06-22 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-05-23 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-04-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-04-21 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-03-31 |
Time |
13:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-12-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-31 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-08 |
Time |
15:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-09-16 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-09-16 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-09-16 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
P |
Date |
2016-08-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-08-23 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-08-23 |
Time |
15:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2016-06-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-06-02 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-06-02 |
Time |
15:02 |
Sent To |
|
|
Notes |
2016-06-02 15:02:42 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2016-04-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-04-20 |
Time |
08:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-04-20 |
Time |
08:00 |
Sent To |
|
|
Notes |
2016-04-20 08:00:58 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-28 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-28 |
Time |
07:56 |
Sent To |
|
|
Notes |
2015-12-28 07:57:10 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2016-06-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-06-02 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-06-02 |
Time |
16:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-04-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-04-20 |
Time |
18:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-04-19 |
Time |
17:54 |
Sent To |
|
|
Notes |
2016-04-20 18:43:04 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY MECHANICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE ENERGY FORM CONTAINS NUMEROUS ERRORS. THE DESIGN | | LOCATION IS PALM BEACH COUNTY AND NOT MIAMI OR KEY | | BISCAYNE, THE INSULATION FOR THE FLOOR OVER THE GARAGE | | IS R-22 AND NOT R-11, THE SECOND FLOOR WALLS OF THE | | CONDITIONED SPACE HAVE R-22 INSULATION AND THE CEILING | | HAS R-38 PER THE PLANS. REVIEW AND COORDINATE THE | | ENERGY FORM WITH THE PLANS. THE FORMS ARE REQUIRED TO | | BE SIGNED AND DATED BY THE PREPARER AND THE | | OWNER/AGENT. FBC ENERGY R101.5.1.1.2 | | | | 2) SUBMIT TWO COPIES OF HEATING AND COOLING EQUIPMENT | | SIZING CALCULATIONS AS REQUIRED BY FBCR-M1401.3. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-12-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-31 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-30 |
Time |
17:57 |
Sent To |
|
|
Notes |
2015-12-31 09:57:18 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY MECHANICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE ENERGY EFFICIENCY FORM THAT WAS SUBMITTED IS FOR | | THE 2010 FBC. THE CURRENT ONE IS FORM 405-14. FBC | | ENERGY R101.5.1.1.2 | | | | 2) THE ENERGY FORM CONTAINS NUMEROUS ERRORS. THE DESIGN | | LOCATION IS PALM BEACH COUNTY, THE INSULATION OF THE | | FLOOR OVER THE GARAGE IS NOT R-0, THE SECOND FLOOR | | WALLS OF THE CONDITIONED SPACE ARE WOOD FRAME. THE | | FORMS ARE REQUIRED TO BE SIGNED AND DATED BY THE | | PREPARER AND THE OWNER/AGENT. FBC ENERGY R101.5.1.1.2 | | | | 3) SPECIFY THE DUCT SIZES, GRILL SIZES AND CFMS AT EACH | | OUTLET. FBC 107.2.1 | | | | 4) SHOW THE LOCATION OF THE CONDENSING UNIT ON THE | | MECHANICAL PLANS. FBC 107.2.1 | | | | 5) PROVIDE AN ANCHORING DETAIL FOR THE CONDENSING UNIT | | TO SHOW THAT IT WILL WITHSTAND A 170 MPH WIND SPEED. | | FBCR-M1401.4 & FBC-R301.2.1 | | | | 6) DISCONNECTS ARE REQUIRED FOR BOTH THE AIR HANDLER | | AND THE CONDENSING UNIT. FBCR-E4101.5 | | | | 7) SUBMIT TWO SETS OF THE MANUFACTURER'S SPECIFICATIONS | | AND INSTALLATION INSTRUCTIONS FOR THE AIR HANDLER | | (PLA-A18BA4) TO SHOW THAT IT CAN BE USED WITH SUPPLY | | DUCTS. FBCR-M1401.1 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-05-31 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-05-31 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-05-31 |
Time |
16:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-04-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-04-11 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-04-11 |
Time |
13:57 |
Sent To |
|
|
Notes |
2016-04-11 14:11:59 | 2ND REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. WASHING MACHINE AND OUTDOOR SHOWER SHALL BE VENTED | | INDIVIDUALLY SHALL COMPLY WITH FBC RES. SEC. P3106.1 | | INDIVIDUAL VENT PERMITTED. | | EACH TRAP AND TRAPPED FIXTURE SHALL BE PERMITTED TO BE | | PROVIDED WITH AN INDIVIDUAL VENT. THE INDIVIDUAL VENT | | SHALL CONNECT TO THE FIXTURE DRAIN OF THE TRAP OR | | TRAPPED FIXTURE BEING VENTED. | | | | 2. SECOND FLOOR THE KITCHEN SHALL CONNECT DOWNSTREAM OF | | THE BATHROOM GROUP. SHALL COMPLY WITH FBC RES. SEC. | | P3108.1 HORIZONTAL WET VENT PERMITTED. | | ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS | | LOCATED ON THE SAME FLOOR LEVEL SHALL BE PERMITTED TO | | BE VENTED BY A HORIZONTAL WET VENT. THE WET VENT SHALL | | BE CONSIDERED THE VENT FOR THE FIXTURES AND SHALL | | EXTEND FROM THE CONNECTION OF THE DRY VENT ALONG THE | | DIRECTION OF THE FLOW IN THE DRAIN PIPE TO THE MOST | | DOWNSTREAM FIXTURE DRAIN CONNECTION. EACH FIXTURE DRAIN | | SHALL CONNECT HORIZONTALLY TO THE HORIZONTAL BRANCH | | BEING WET VENTED OR SHALL HAVE A DRY VENT. EACH | | WET-VENTED FIXTURE DRAIN SHALL CONNECT INDEPENDENTLY TO | | THE HORIZONTAL WET VENT. ONLY THE FIXTURES WITHIN THE | | BATHROOM GROUPS SHALL CONNECT TO THE WET-VENTED | | HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL FIXTURES SHALL | | DISCHARGE DOWNSTREAM OF THE HORIZONTAL WET VENT. | | | | 3. THE OUT DOOR SHOWER SHALL BE COVERED TO PREVENT | | STORM WATER FROM DRAINING INTO SANITARY SYSTEM. PER | | CODE OF ORDINANCES CITY OF WEST PALM BEACH, FLORIDA | | SEC.9-126.(5) | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-12-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-12-12 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-12-12 |
Time |
11:04 |
Sent To |
|
|
Notes |
2015-12-12 11:19:33 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1.PLEASE PROVIDE PLUMBING RISER DIAGRAM. PER WPB AMEN. | | TO FBC SEC 107.3.5.3 RESIDENTIAL (ONE AND | | TWO-FAMILY)(11) | | 2.SHOW LOCATION OF WATER HEATER.PER WPB AMEN. TO FBC | | SEC 107.2.1 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2016-08-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-08-23 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-08-23 |
Time |
15:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2016-04-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-04-20 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-04-20 |
Time |
18:52 |
Sent To |
|
|
Notes |
2016-04-20 18:53:57 | ADDITIONAL INFORMATION FOR ROOFING MATERIAL IS | | REQUIRED. SEE BUILDING COMMENTS. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2015-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-12-28 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-12-28 |
Time |
08:38 |
Sent To |
|
|
Notes |
2015-12-28 08:38:40 | NO PRODUCT APPROVALS WERE SUBMITTED FOR THE ASPHALT | | ROOF SHINGLES OR THE RIDGE VENT THAT ARE SPECIFIED ONE | | SHEET A3.1. NO PRODUCT APPROVALS WERE SUBMITTED FOR THE | | BARREL TILE SHED ROOF SHOWN ON A4.1. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-12-22 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-12-22 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-12-22 |
Time |
16:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-09-09 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-09-09 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-09-09 |
Time |
14:47 |
Sent To |
B |
|
Notes |
|
|