Plan Review Details - Permit 15081167
Plan Review Stops For Permit 15081167
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-01-25 Cont ID  
Sent By rmcdouga Date 2016-01-25 Time 16:50 Rev Time 0.00
Received By rmcdouga Date 2016-01-25 Time 16:20 Sent To  
Notes
2016-01-25 17:12:30COMPLY WITH FBC R4501.17 FOR RESIDENTIAL POOL BARRIER
 REQUIREMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-02 Cont ID  
Sent By rmcdouga Date 2015-09-02 Time 18:45 Rev Time 0.00
Received By rmcdouga Date 2015-09-02 Time 17:48 Sent To  
Notes
2015-09-02 18:52:26PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SHOW COMPLIANCE WITH FBCR 4501.17 FOR REQUIRED
 SWIMMING POOL BARRIER. SPECIFY THE METHOD OR
 COMBINATION OF METHODS THAT WILL BE USED.
  
 2) SECTION R403.9.2 OF THE 2014 ENERGY CONSERVATION
 CODE REQUIRES TIME SWITCHES FOR PUMPS AND HEATERS.
  
 3) SECTION R403.9.3 OF THE 2014 ENERGY CONSERVATION
 CODE REQUIRES HEATED POOLS TO HAVE COVERS TO REDUCE
 HEAT LOSS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-01-25 Cont ID  
Sent By rmcdouga Date 2016-01-25 Time 16:50 Rev Time 0.00
Received By rmcdouga Date 2016-01-25 Time 16:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-09-02 Cont ID  
Sent By rmcdouga Date 2015-09-02 Time 18:07 Rev Time 0.00
Received By rmcdouga Date 2015-09-02 Time 18:07 Sent To  
Notes
2015-09-02 18:09:13PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE POOL PERMIT WILL NOT BE ISSUED UNTIL A POOL
 ELECTRICAL SUB-PERMIT IS SUBMITTED. FBC 105.1
  
 2) SHOW COMPLIANCE WITH FBCR - E 4204.2 FOR
 EQUIPOTENTIAL BONDING.
  
 3) SHOW COMPLIANCE WITH FBCR - E 4204.3 FOR REQUIRED
 BONDING OF POOL WATER.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2015-09-02 Cont ID  
Sent By tklarge Date 2015-09-02 Time 04:45 Rev Time 0.00
Received By tklarge Date 2015-09-02 Time 04:45 Sent To  
Notes
2015-09-02 04:46:41THE HEATER IS AN ELECTRIC HEAT PUMP. THERE IS NO GAS ON
 THIS POOL.TKL.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-01-25 Cont ID  
Sent By rmcdouga Date 2016-01-25 Time 16:50 Rev Time 0.00
Received By rmcdouga Date 2016-01-15 Time 15:33 Sent To  
Notes
2016-01-19 15:33:48RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-02 Cont ID  
Sent By rmcdouga Date 2015-09-02 Time 18:52 Rev Time 0.00
Received By rmcdouga Date 2015-08-31 Time 13:56 Sent To  
Notes
2015-08-31 13:56:40ROUTED TO ZONING

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-01-20 Cont ID  
Sent By tklarge Date 2016-01-20 Time 12:36 Rev Time 0.00
Received By tklarge Date 2016-01-20 Time 11:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-09-02 Cont ID  
Sent By tklarge Date 2015-09-02 Time 05:06 Rev Time 0.00
Received By tklarge Date 2015-09-02 Time 04:27 Sent To  
Notes
2015-09-02 05:04:311) POOL SPECS BOX: THE TURNOVER RATE FOR THE POOL IS
 NOTED AS 6 HR. ? MIN. FOR 21,542 GALS. I HAVE
 CALCULATED A TURNOVER RATE OF 11.58 HOURS. CLARIFY.
 2) SUBMIT 2 COPIES OF THE MANUFACTURER'S SPECIFICATIONS
 FOR THE HEAT PUMP. THE INFORMATION SHALL CLEARLY SHOW
 COMPLIANCE WITH THE 2014 FL. ENERGY CODE SEC.R403.9.1 &
 R403.9.1.2. HEAT PUMPS SHALL HAVE A MINIMUM COP OF 4.0
 AND SHALL BE TESTED IN ACCORDANCE WITH AHRI 1160, TABLE
 2.A TEST REPORT FROM AN INDEPENDENT LABORATORY IS
 REQUIRED TO VERIFY PROCEDURE COMPLIANCE.
 3) 2014 FBC- ENERGY CODE SEC. R 403.9.2 - TIME SWITCHES
 OR OTHER CONTROL METHODS THAT CAN AUTOMATICALLY TURN
 OFF AND ON HEATERS AND PUMPS ACCORDING TO A PRESET
 SCHEDULE SHALL BE INSTALLED ON ALL HEATERS AND PUMPS.
 HEATERS, PUMPS AND MOTORS THAT HAVE BUILT IN TIMERS
 SHALL BE DEEMED IN COMPLIANCE WITH THIS REQUIREMENT.
 4) SUBMIT A COPY OF THE PUMP CURVE FOR THE POOL/SPA
 PUMP AND IDENTIFY THE TOTAL DYNAMIC HEAD CALCULATIONS
 PER FOR THIS POOL PER ANSI/APSP-7 SEC. 4.4.1.
 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR BOTH
 CHANNEL DRAINS TO ENSURE COMPLIANCE WITH ANSI/APSP-7
 SEC.5.5.1
  
  
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-09-01 Cont ID  
Sent By sgraham Date 2015-09-01 Time 10:08 Rev Time 0.00
Received By sgraham Date 2015-09-01 Time 10:08 Sent To B
Notes
***NONE***