Plan Review Stops For Permit 15081155 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-09-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-22 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-22 |
Time |
08:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-10 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-10 |
Time |
07:32 |
Sent To |
|
|
Notes |
2015-09-10 10:34:57 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THERE WAS NO CROSS SECTION OF THE LONG DIMENSION | | POOL. SPECIFY THE DEPTH BOTH ENDS OF THE POOL. FBC | | 107.2.1 | | | | 2) THE POOL IS REQUIRED TO COMPLY WITH R4501.18 LADDERS | | AND STEPS. | | ALL POOLS WHETHER PUBLIC OR PRIVATE SHALL BE PROVIDED | | WITH A LADDER OR STEPS IN THE SHALLOW END WHERE WATER | | DEPTH EXCEEDS 24 INCHES (610 MM). IN PRIVATE POOLS | | WHERE WATER DEPTH EXCEEDS 5 FEET (1524 MM), THERE SHALL | | BE LADDERS, STAIRS OR UNDERWATER BENCHES/SWIMOUTS IN | | THE DEEP END. WHERE MANUFACTURED DIVING EQUIPMENT IS TO | | BE USED, BENCHES OR SWIMOUTS SHALL BE RECESSED OR | | LOCATED IN A CORNER. | | EXCEPTION: IN PRIVATE POOLS HAVING MORE THAN ONE | | SHALLOW END, ONLY ONE SET OF STEPS ARE REQUIRED. A | | BENCH, SWIM-OUT OR LADDER MAY BE USED AT ALL ADDITIONAL | | SHALLOW ENDS IN LIEU OF AN ADDITIONAL SET OF STEPS. | | | | 3) THE FLORIDA BUILDING CODE 5TH EDITION (2014) | | RESIDENTIAL HAS THE SWIMMING POOL ELECTRICAL PROVISIONS | | IN CHAPTER 42 AND THE PRIVATE SWIMMING POOL PROVISIONS | | ARE NOW IN CHAPTER 45. THE CODE SECTIONS REFERENCED ON | | THE PLAN ARE INCORRECT. | | | | 4) THE VALUE SPECIFIED FOR THE POOL OF $20,000.00 | | APPEARS TO BE LOW. SUBMIT A COPY OF THE SIGNED CONTRACT | | TO VERIFY THE VALUATION. FBC 109.3 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-09-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-22 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-22 |
Time |
08:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-10 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-10 |
Time |
07:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-10 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-10 |
Time |
07:56 |
Sent To |
|
|
Notes |
2015-09-10 08:00:55 | A SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED | | FOR GAS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-09-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-22 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-14 |
Time |
12:04 |
Sent To |
|
|
Notes |
2015-09-15 12:04:49 | RESUB ROUTED TO SGRAHAM |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-10 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-08-31 |
Time |
16:38 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-09-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-21 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-21 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-09-02 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-02 |
Time |
05:40 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-02 |
Time |
05:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2015-09-16 |
Time |
|
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-09-16 |
Time |
11:13 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-09-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-10 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
|
Date |
2015-09-04 |
Time |
|
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-09-01 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-09-01 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-09-01 |
Time |
10:12 |
Sent To |
B |
|
Notes |
2015-09-01 10:14:55 | 9/1/15 ZONING FAILED | | | | 1. SUBMIT CLEAR COPIES OF THE SURVEY, SHOWING THE | | LOCATION OF THE POOL WITH SETBACKS FROM WATER'S EDGE | | CLEARLY DEFINED. |
|
|