Plan Review Details - Permit 15081130
Plan Review Stops For Permit 15081130
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-10-01 Cont ID  
Sent By skennedy Date 2015-10-01 Time 14:42 Rev Time 0.00
Received By skennedy Date 2015-10-01 Time 14:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-22 Cont ID  
Sent By skennedy Date 2015-09-22 Time 08:40 Rev Time 0.00
Received By skennedy Date 2015-09-22 Time 08:39 Sent To  
Notes
2015-09-22 08:41:431ST REVIEW: FBC 2014 5TH ED.
  
 FBC 107.3.5.1.1(8) - PROVIDE ENGINEERED WIND DESIGN
 LOADS/DESIGN PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-10-01 Cont ID  
Sent By skennedy Date 2015-10-01 Time 14:42 Rev Time 0.00
Received By skennedy Date 2015-10-01 Time 14:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-09-22 Cont ID  
Sent By skennedy Date 2015-09-22 Time 08:41 Rev Time 0.00
Received By skennedy Date 2015-09-22 Time 08:41 Sent To  
Notes
2015-09-22 08:43:331ST REVIEW: FBC 2014 5TH ED.
  
 DEMONSTRATE COMPLIANCE WITH THE BELOW.
  
 ELECTRIC SIGNS, SECTION SIGNS, AND OUTLINE LIGHTING,
 FIXED, MOBILE, OR PORTABLE, SHALL BE LISTED AND
 INSTALLED IN CONFORMANCE WITH THAT LISTING, UNLESS
 OTHERWISE APPROVED BY SPECIAL PERMISSION. 600.3
 LISTING.
  
 EACH SIGN AND OUTLINE LIGHTING SYSTEM, OR FEEDER
 CIRCUIT OR BRANCH CIRCUIT SUPPLYING A SIGN OR OUT-LINE
 LIGHTING SYSTEM, SHALL BE CONTROLLED BY AN EXTERNALLY
 OPERABLE SWITCH OR CIRCUIT BREAKER THAT WILL OPEN ALL
 UNGROUNDED CONDUCTORS WITHIN SIGHT OF THE SIGN NEC
 600.6(A)(1)
  
 ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 505.1 SHALL
 HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT OR WHEN
 NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR & TIME
 CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME SWITCHES
 SHALL BE CAPABLE OF RETAINING PROGRAMING DURING A LOSS
 OF POWER FOR A MINIMUM OF 10 HOURS. FBC-E 505.2.4
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-10-01 Cont ID  
Sent By skennedy Date 2015-10-01 Time 14:42 Rev Time 0.00
Received By skennedy Date 2015-09-28 Time 09:14 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-22 Cont ID  
Sent By skennedy Date 2015-09-22 Time 08:41 Rev Time 0.00
Received By skennedy Date 2015-08-28 Time 11:28 Sent To  
Notes
2015-09-17 16:29:179/17 TO SAK DESK
  
  
2015-09-17 15:09:29TO MISC 2 BOX.
2015-08-31 11:28:43ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2015-09-17 Cont ID  
Sent By aaponte Date 2015-09-17 Time 15:08 Rev Time 0.00
Received By aaponte Date 2015-09-17 Time 15:08 Sent To  
Notes
2015-09-17 15:09:06PROVISO: MAX HEIGHT OF SIGN SHALL BE 36" FROM TOP OF
 LOGO TO BOTTOM.