Plan Review Stops For Permit 15081122 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2016-01-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-01-07 |
Time |
17:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-01-07 |
Time |
17:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2016-01-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-01-06 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-01-06 |
Time |
08:38 |
Sent To |
|
|
Notes |
2016-01-06 08:41:44 | RESIDENTIAL (R3) RE-ROOF 4TH BUILDING REVIEW CHECKLIST. | | CODE: FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 1- NEW CLAY TILE FLORIDA PRODUCT APPROVAL FL17152-R1 | | WAS SUBMITTED. LIMITATION #3 ON THIS PRODUCT APPROVAL | | SPECIFIES THAT TILES SHALL BE MECHANICALLY ATTACHED FOR | | WIND LOAD RESISTANCE. PRODUCT APPROVAL SUBMITTED | | DOESN'T SPECIFY THE TILE ATTACHMENT RESISTANCE. NEED | | THIS INFORMATION TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION | | (2014). PROVIDE COMPLETE CALCULATIONS SHOWING HOW THE | | PROPOSED MECHANICAL ATTACHMENT IS GOING TO MEET THE | | DESIGN PRESSURES OF SEC. R301. | | NOTE: NOA 14-0107.02 PREVIOUSLY SUBMITTED HAD ALL THIS | | INFORMATION. THE ONLY THING THAT WAS MISSING WAS THE | | PRODUCT APPROVAL FOR THE ADHESIVE TO BE USED. | | | | RESPONSE TO MR. MUNROE'S E-MAIL: | | GOOD MORNING MR. MUNROE, | | THE NOA 14-0529.02 SUBMITTED FOR THE FLAT ROOF IS OK. I | | ALREADY PRINTED THE PAGES WE NEED INCLUDING PAGE 37 | | WITH THE SELECTED ASSEMBLY TO BE INSTALLED. | | REGARDING THE CLAY ROOF TILE ENGINEER CALCULATIONS, YOU | | CAN E-MAIL THEM TO ME FOR REVIEW. ASK THE ENGINEER TO | | INCLUDE THE DESIGN CRITERIA FBC-RESIDENTIAL, 5TH | | EDITION (2014), DESIGN PRESSURES, WIND SPEED, BUILDING | | HEIGHT AND THE BUILDING EXPOSURE IS "C". | | WE WILL NEED THE ENGINEER'S CALCULATIONS WITH ORIGINAL | | SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471 FLORIDA | | STATUTE WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS. | | THANK YOU, | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2015-12-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-12-29 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-12-29 |
Time |
17:13 |
Sent To |
HIST |
|
Notes |
2015-12-29 17:13:58 | RESIDENTIAL (R3) RE-ROOF THIRD BUILDING REVIEW | | CHECKLIST. | | CODE: FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 1- NEW CLAY TILE FLORIDA PRODUCT APPROVAL FL17152-R1 | | WAS SUBMITTED. LIMITATION #3 ON THIS PRODUCT APPROVAL | | SPECIFIES THAT TILES SHALL BE MECHANICALLY ATTACHED FOR | | WIND LOAD RESISTANCE. PRODUCT APPROVAL SUBMITTED | | DOESN'T SPECIFY THE TILE ATTACHMENT RESISTANCE. NEED | | THIS INFORMATION TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION | | (2014). PROVIDE COMPLETE CALCULATIONS SHOWING HOW THE | | PROPOSED MECHANICAL ATTACHMENT IS GOING TO MEET THE | | DESIGN PRESSURES OF SEC. R301. | | NOTE: NOA 14-0107.02 PREVIOUSLY SUBMITTED HAD ALL THIS | | INFORMATION. THE ONLY THING THAT WAS MISSING WAS THE | | PRODUCT APPROVAL FOR THE ADHESIVE TO BE USED. | | | | 2- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R15 | | SUBMITTED: CLEARLY MARK WHICH APPROVED ASSEMBLY IS | | GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301. THIS BUILDING IS LOCATED | | IN EXPOSURE "C". IF THE SELECTED ASSEMBLY DOESN'T MEET | | THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN SIGNED | | AND SEALED RAS 117 CALCULATIONS WOULD BE REQUIRED. SEE | | NOTE #8 ON PAGE 2 OF 76. | | (REPEAT COMMENT. NOT ADDRESSED AT ALL. THIRD TIME). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-12-11 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-12-11 |
Time |
16:42 |
Sent To |
|
|
Notes |
2015-12-11 16:43:42 | 12/11/15 TALKED TO MONICA CORTEZ. (954)802-3726. I TOLD | | HER, I HAVE NOT SEEN ANY NEW ENGINEERING FOR THIS | | HOUSE. MY LAST REVIEW WAS DONE ON 10/16/15. THERE ARE | | NO RE-SUBMITTALS FOR THIS PROJECT AFTER THAT DATE. JG. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-10-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-10-16 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-10-16 |
Time |
17:19 |
Sent To |
|
|
Notes |
2015-10-16 18:14:10 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 1- ORIGINALLY THIS HOUSE WAS DESIGNED TO HAVE SHINGLES | | ROOFING. PROPOSAL TO INSTALL CLAY TILES REQUIRES | | ENGINEERING ANALYSIS TO VERIFY IF THE STRUCTURE IS | | ADEQUATE TO RECEIVE THE ADDITIONAL LOAD. SEC. 107.2.1.3 | | CITY AMENDMENTS. | | | | RESPONSE: | | ENGINEER LETTER SUBMITTED: | | (1) IT APPEARS THAT WRONG HOUSE WAS INSPECTED BY THE | | ENGINEER. IT LOOKS LIKE THE ENGINEER INSPECTED THE | | HOUSE LOCATED AT 505 38TH STREET AS STATED ON THE | | LETTER. THE HOUSE FOR THIS PERMIT IS 502 38TH STREET, | | WHICH IS LOCATED ACROSS THE STREET. THE BUILDING | | FRAMING SYSTEM IS DIFFERENT FOR BOTH HOUSES. ONE HOUSE | | WAS BUILT IN 1954 AND THE OTHER ONE WAS BUILT IN 1925. | | THERE MAY NOT BE A TRUSS SYSTEM ON THE HOUSE BUILT IN | | THE 1925'S. ENGINEER TO REVISE ADDRESS AND PROVIDE | | COMPLETE ROOF FRAMING AND SUPPORTING WALLS INFORMATION | | FOR THE CORRECT HOUSE. SEC. 107.2.1.3 CITY AMENDMENTS. | | | | (2) THE ORIGINAL ROOF COVERING OF THIS HOUSE WAS | | SHINGLES NOT CLAY TILES. REVISE AS REQUIRED. SEC. | | 107.2.1 CITY AMENDMENTS. | | | | (3) ENGINEER TO PROVIDE ALL HIS INFORMATION AND THE | | FIRM CERTIFICATE OF AUTHORIZATION NUMBER AS REQUIRED BY | | SEC. 61G15-23.002 AND CHAPTER 471 FLORIDA STATUTE. | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR THE TILE ADHESIVE LISTED ON THE | | CLAY TILE NOA. | | (REPEAT COMMENT. NOT ADDRESSED AT ALL). | | | | 3- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R15 | | SUBMITTED: CLEARLY MARK WHICH APPROVED ASSEMBLY IS | | GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301. THIS BUILDING IS LOCATED | | IN EXPOSURE "C". IF THE SELECTED ASSEMBLY DOESN'T MEET | | THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN SIGNED | | AND SEALED RAS 117 CALCULATIONS WOULD BE REQUIRED. SEE | | NOTE #8 ON PAGE 2 OF 76. | | (REPEAT COMMENT. NOT ADDRESSED AT ALL). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-08-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-08-31 |
Time |
19:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-08-31 |
Time |
18:38 |
Sent To |
|
|
Notes |
2015-08-31 19:18:52 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 1- ORIGINALLY THIS HOUSE WAS DESIGNED TO HAVE SHINGLES | | ROOFING. PROPOSAL TO INSTALL CLAY TILES REQUIRES | | ENGINEERING ANALYSIS TO VERIFY IF THE STRUCTURE IS | | ADEQUATE TO RECEIVE THE ADDITIONAL LOAD. SEC. 107.2.1.3 | | CITY AMENDMENTS. | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR THE TILE ADHESIVE LISTED ON THE | | CLAY TILE NOA. | | | | 3- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R15 | | SUBMITTED: CLEARLY MARK WHICH APPROVED ASSEMBLY IS | | GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301. THIS BUILDING IS LOCATED | | IN EXPOSURE "C". IF THE SELECTED ASSEMBLY DOESN'T MEET | | THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN SIGNED | | AND SEALED RAS 117 CALCULATIONS WOULD BE REQUIRED. SEE | | NOTE #8 ON PAGE 2 OF 76. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2015-08-31 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2015-08-31 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2015-08-28 |
Time |
13:53 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2016-01-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-01-07 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-01-07 |
Time |
17:43 |
Sent To |
|
|
Notes |
2016-01-07 17:44:21 | HI MR. GOMEZ, | | I'M JUST GOING TO FOAM THE TILES DOWN TO MAKE IT | | SIMPLE. I'M HAVING A HARD TIME WITH THE ENGINEER | | GETTING THEM TO RESPOND, THEY WANT TO CHARGE FOR THE | | LETTER, ETC. SO LET'S JUST GO WITH THE MIAMI DADE | | APPROVAL OF FOAMING IF YOU NEED ME TO CIRCLE THAT OR IF | | YOU CAN JUST CIRCLE THE ORIGINAL ONE I SUBMITTED THAT | | WOULD BE GREAT. | | | | THANKS | | | | SENT FROM MY IPHONE | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-01-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-01-06 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-01-06 |
Time |
08:37 |
Sent To |
|
|
Notes |
2016-01-06 08:37:50 | RECEIVED E-MAIL FROM TONY MUNROE. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-12-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-12-29 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-12-23 |
Time |
15:16 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-10-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-10-16 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-10-15 |
Time |
16:10 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-08-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-08-31 |
Time |
18:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-08-28 |
Time |
15:00 |
Sent To |
|
|
Notes |
2015-08-31 15:00:47 | JGOMEZ |
|
|